Smoke detector ms-as-02-4
Smoke detector
Product information
The product is a new type of photoelectric smoke detector, when it detects smoke, it will output signal immediately and trigger connected unit to work, which tell you in advance that fire will occurs and avoid unwanted loss, and take you safety and convenience.
Specifications
Power supply:dc12v~dc33v
Work temperature:-10~+40
Static current:17-20a(24v) 17-23a(33v)
Working humidity:
RP-2001 is a UL listed six-zone fire alarm control panel for single and dual hazard deluge and preaction applications, providing fire detection, signaling and protection for commercial, industrial and institutional buildings requiring water-based releasing.! Features & Benefits: 1. Designed for sprinkler standards NFPA 13, 15 and 16. 2. Dual hazard operation. 3. Cross-zone (double-interlock) capability. 4. Six programmable Style B (Class B) IDCs (Initiating Device Circuit). 5. Optional Digital Alarm Communicators
RP-2002 is a UL listed six-zone fire alarm control panel for single and dual hazard agent releasing applications, providing fire detection, signaling and protection for commercial, industrial and institutional buildings requiring agent-based releasing. Features & Benefits: Disable/Enable control per input zone and output zone. Extensive transient protection. Dual hazard operation Meets International Building Code (IBC) seismic requirements
Model No. SR-812DC-4 Operating voltage DC9~35V Alarm temperature 57 Static current 13mA(NC);4mA(NO) Alarm current 9mA(NC);19mA(NO) Alarm output Relay output Installation Ceiling mounted Sensitivity 2.06%ft±1.3%ft Working environment -10~+50(â?¤95%RH No congelation) Dimension 100*46mm
HS-DG812 Battery Powered Photoelectric Smoke Alarm with excellent stability and high-sensitivity. Our standard battery is 6F22, lithium battery is optional. Key Specifications/Special Features Power Source: 9V Battery (included). Audio Alarm: 85dB/3m Temperature Range: 0 to 40 Humidity Range: 5%-95% relative humidity(RH) Sensor: Photoelectric Size: diameter 106mm in diameter x32mm depth Interconnects: No Easy to install with mounting base included Suitable for any room Low battery signal Test button for simple testing
2 or 4 wire models * Dual LEDs for 360�‹visibility * Advanced detection and discrimination algorithms * Easy installation and maintenance * Sleek low-profile housing design * Durable sensor head, no need for replacement * SMD circuit board design-satisfactory quality and reliability guaranteed * Integrated heat detector for NB326-H-2 and NB326-H-4 models * N/C (normal/close)-N/O (normal/open)selectable relay output * AR (Auto Reset) function for security systems (optional for 4 wire models) * Sensor base option: standard and Shottky Diode.
Smoke detector ox-8 Remote control 12 metres Operation voltage-10ÿ30 v Economy mode consumption current-0, 1 ma Normal mode consumption current-0, 25 ma Alarm mode consumption current up to-20 ma Smoke sensitive range-0, 05ÿ0, 2 db/m Models with possibility setting by user (ir transmitter) Sensibility value-0, 05;0, 10;0, 15 db/m Visual check-out of function ability for smoke channel The response time of temperature canal depends on speed of temperature alternation and meets with en-54-7 Operation temperature range-minus 25up to+70 Dimensionns 100x54 mm Weight & 0, 17 kg
Main Feature: reset after power disconnection infrared photoelectric sensor network output / LED indicator stainless steel shield for anti-EMI SMT adopted Strong adaptability to circumstance Dustproof, mothproof, anti-white light Technology parameter: Operating voltage: DC12V Standby current: 2mA Alarm current: 10mA Operating temp.: -10-50 Working humidity: 95%RH Alarm mode: network output / LED indicator Detecting area: 20 square meter Sensitivity: class I Alarm output: relay output (N.C.)
Conventional Reflective Optical Beam Smoke detector Beam Detector Beam Alarm Sensor with Relay Output Introduction The Conventional Reflective Beam Detector has built in Laser beam pointing and Digital guide display for real user friendly alignment method. The Laser beam pointing accurately point the exact location where to mount mirror and with additional digital guide display allows to monitor and guide on the actual light intensity between the mirror and detector which cannot be seen by our naked eye making it more easy and convenient in alignment commissioning. The beam detector has four adjustable operational range of between 8 to 20, 40, 70 and 100 meters beside with three adjustable sensitivity setting ranges from 2.6dB to 4.8dB to meet the specific environmental requirement. The detector works on the principle of reflective infrared beam obscuration. Used in conjunction with a reflectors, it will notify the fire alarm panel when the infrared beam is obscured by smoke. Secure and quick communication through the onboard processor enables the detector to make its own decision and drift compensation resulting in greater automation. The detector is ideal for use high ceiling and wide areas such as warehouses, large storages, shopping malls, leisure centres, exhibition halls, hotel lobbies, printing houses, garment factories, museums and prisons, as well as places where slight smoke particles or corrosive gas exist. Feature and Benefits 1. Manufacture in compliance with EN54-12 2. Hassle free alignment, built with digital guide display and laser beam pointing 3. Employ single-ended design through reflective mirror. 4. Four ranges wide monitoring from 8-100 meters via encoder 5. Three users programing sensitivity adjustment 6. Built-in microprocessor 7. Self-diagnosis function can monitor for internal faults 8. Automatic compensation for factors weakening received signals, such as dust contamination, positional movement and ageing of the transmitter 9. Fire and Fault interfacing relays 10. Attractive and pleasing appearance 11. Real User friendly alignment method