AC powered gas alarm
1.Semiconductor sensor
2.Power Supply: AC110/220
3.Comply EN50194
4.Fault signal, low battery warning,
Stand-alone GAS Alarm from PEASAWY.COM
1.Sensor Type: semiconductor sensor
2.Power Supply: 12-24VDC
3.Standby Current: 10uA
4.Alarm Current: 23mA
5.Operation Temperature: 0¡ã- 50¡ã
6.Low battery warning
7.Self-Test Button to verify operation
8.Silence function with dual led indicator
9.Sensitivity meets EN50194
10.Alarm Sound Level: >85dB at 10 feet (3m)
11.Easy to install, move and maintain.
Supplier: Gas lighter, led screen protector ( not even in domestic ), refill paper cups, table runner, earing brass clamp, auto brass electric parts, cashew nuts, wire mesh, petha sweet, niwar, mohini powder, vermicompost, dry bath incubator, test tube plastic, sordium citrate tube, health care product, ornamental freshwater fish, safed musli, used polymer bag, cotton linter, auto hood cover, areca plate, rice
1.GK Combined CH4&CO Alarm Description The GK Combined CH4&CO Alarm is used to test both natural gas and carbon monoxide in home. Its a two in one detector so it shall save more home space with much economic price. 2.GK Combined CH4&CO Alarm Features Available to test both CH4 and CO Best selling model Optional valve and relay output. 3.GK Combined CH4&CO Alarm Application The GK combined alarm is used to test both natural gas and carbon monoxide in home. Itâ??s a two in one detector so it shall save more home space with much economic price. 4.GK Combined CH4&CO Alarm Specifications Measuring gas Natural gas and carbon monoxide Working voltage AC220V±15%/AC110V±15% 50Hz~60Hz DC12V Sensor life >3 years Alarming level CH4: 10%LEL;CO: Follow EN50291 Working Environment Temperature: -10 - 50 Humidity:
"Semiconductor sensor Operating voltage: 85-265V AC; Alarm output: Sound& LED Flash alarm; Alarm level: 10% ±5% LEL. adopted SCM from USA to ensure the stability, Dimension: 118.5*82*43mm . Execute criterion:GB15322;EN50194;UL1484 Can make 9V chargable back up battery "
Home gas detector alarm description: High stability sensor Circuit for normally closed relay contacts (optional) Circuit for normally opened relay contacts (optional) Operating frequency: 433 or 315mhz (optional) Size: 110 x 70 x 40mm Weight: 228g/pieces . Size:110mm*70mm*40mm; 228g/pc.
AK-200FC/D2 Product Description: 1. Model: AK-200FC/D/D2 2. Embeded type 3. working environment: Humidity: ¿Q97%RH Temperature: 0íµ-60íµ 4. Dimensions: 86mm*86mm*60mm 5. Working voltage: 220VAC /110VAC, 12VDC-20VDC 6. Additional function: can work with solenoid valve or manipulator or exhaust fan (optional) 7. Networking: wired networking (NO, NC) 8. Wireless networking mode: 315MHZ/433MHZ (2262 OR 1527) 9. Alarm concentration: coal gas: 0.1%~0.5% natural gas: 0.1%~1% LPG: 0.1%~0.5% 10. Automatic error-detecting function (The red and green lights shine alternatively). 100pcs/CTN.
AK-200FC/L Product Description: 1. Model: AK-200FC/L 2. Back-up battery: Rechargeable battery, ordinary battery 3. working environment: Humidity: ¿Q97%RH Temperature: 0íµ-60íµ 4. Dimensions: 163mm*87mm*40mm 5. Working voltage: 220VAC /110VAC, 12VDC-20VDC 6. Additional function: can work with solenoid valve or manipulator or exhaust fan (optional) 7. Networking: wired networking (NO, NC) 8. Wireless networking mode: 315MHZ/433MHZ (2262 OR 1527) 9. Alarm concentration: coal gas: 0.1%~0.5% natural gas: 0.1%~1% LPG: 0.1%~0.5% 10. Automatic error-detecting function (The red and green lights shine alternatively). 100pcs/CTN.
Smoke & co detectorHeat detector ntc thermal sensor tamper resistant pins for battery4 digits temperature led display shockproof design, suitable for vehicle usecan set maximum or minimum alarm temperature simultaneously test and hush button, auto resetreal ambient temperature correctable on-top battery compartment, easy for battery replacementauto reset /power off reset optional Execute criterion: en54-4, ul539, en14604, ul217 dustproof, mothproof and anti-white light ElectrovalveManipulator gas species: natural gas, lpg, man-made coal gas and other noncorrosive gaspower supply: 8vdc-16vdc 12vdc-26vdc valve body material: brass alloyoperation press: 1.6mpa material for sealing: nbr rubbervalve specification: 4 fen (1fen=1/3centimeter), 6fen, 1 inch, 1.25 inch, 1.5 inch test operating pressure: 25kpa torque: 10kg.Cm~30kg.Cm~40kg.Cm~50kg.Cm11069.540mm Anti-electromagnetic interference, no-spark design Alarm bellBreak glass manual call point size: 2", 3", 4", 6", 8", 9", 10", 12"rated voltage :12vdc or 24vdc / 220vac optional volume: over 105db/mconsumption: 10w working voltage : 12vdc/24vdc With waterproof cover manual call pointSiren with strobe
Gas detector with different color options and voice broadcast function.
"AV voltage: AC 90V-240V 50-60Hz Battery voltage: 9V rechargeable battery (optional) Working temperature: 0°C-50°C Warm-up time: about 180S Environmental humility: 10%-95% Sound level: 85dB / m Alarm density: 2500PPM (±1500PPM) Alarm: vocals and LCD Size: 112 Ã? 73 Ã? 42MM"