Grape (Blue-Black)_ is well known for its taste. It contains proanthocyanidins and anthocyanins which help in reducing the risk of cancer. Grapes are an excellent source of potassium and antioxidants. They are also high in the content of vitamins and minerals. The therapeutic value of grapes is closely linked with its richness in pure glucose. Studies have indicated that the production of energy essential for the proper functioning of the heart and organs of high physiological importance depends on the metabolism of glucose. Grapes, therefore, have a restorative effect by virtue of their easy assimilation. They are thus highly valuable in case of weak digestion, general debility and fever. Viticulture or grape culture is as old as mankind. In India the grape in grown from 1000 AD. And it is one of the most important cash crops grown the in southern and north-western parts of the country. The tropical climate of India makes it suitable to grow, which requires around 25 deg – 30 deg C. The bangalore Blue is one of the most popular varieties grown in southern parts of India. Nutritive value per 100g of fruit Energy (kcal) 58-71 Calcium (mg) 20-20 Phosphorous (mg) 23-30 Iron (mg) 0.5-0.5 Carotene (ug) 3-0 Vitamin C (mg) 1-1 Fibre (g) 2.8-2.9 Grape (Blue-Black) Pulp T.S.S (Brix) Min- 9 Acidity (%C/A) Min- 0.4 Composition per 100 gm Edible Portion (%)- 65.00 Moisture (gm)- 00.60 Protein (gm)- 00.60 Fat(gm)- 00.40 Minerals (gm)- 00.98 Fibre (gm)- 02.18 Carbohydrates (gm)- 13.10 Energy (K.cal)- 58.00 Calcim (mg)- 23.00 Phosphorus (mg)- 23.00 Iron(mg)- 01.30 Vitamin c (mg)- 1.00 Vitamin B (mg)- 00.15
Every house needs this sanitizing rubber mats that can trap dirt and mud from footwear before a person enters the room. Its UV-resistant rubber bristles also ensure a longer lifespan than most other mats. Hirange is your one-stop destination to buy the best sanitizing rubber mats at best price Size : 35*60cm, 40*60cm, 45*75cm, 60*80cm, 80*100cm, 90*150cm, 90*180cm About this item Sanitizing Rubber Mats : This is a mat with raised edges that are used to clean and sterilise the shoe sole. The Black Carpet Mat : This mat will be inserted into the designer mat with a mix of water and surface disinfectant. Grey Carpet Mat: It will be placed on the trays front line to clean and dry the shoe sole before travelling to any specific spot. Disinfectant : It is a surface sanitizer that should be used at a rate of 10 mL per liter of water. (This is not included.) Uses Sanitizing rubber mats can be used by varieties of industries like Apartments, Housing Societies, Condominiums, Government and private offices, Factories, Banks, Financial Firms, ATMs, Hospitals and Nursing Homes Sports Complexes, Gymnasiums, Pools, Car Dealer Showrooms, Hotels, Restaurants and Cafes, Religious Places, Bus Stands, Railway Stations, Airports, Subway Stations, Schools, Universities, Colleges, Guesthouses, Coaching Centre, Cinema halls, Movie Theaters, Auditoriums, Marriage Halls Sanitizing Rubber Mats A DISINFECTANT FLOOR MAT: A Sanitizing rubber mat is designed to keep dirt, grime, water, snow, and debris from being tracked into your home. It can be filled with disinfection liquid to keep shoes clean and sanitary before entering the premises. MADE TO LAST A LIFETIME: It is comprised of superior quality polymer bristles and ultra-absorbent fabric, and it does an excellent job of keeping feet clean. Furthermore, the surface of the Sanitizing rubber mats will not degrade with repeated additions of disinfectant for cleaning and disinfection. ANTI-SLIP BACKING: The supplied disinfecting floor mat has a safe and non-slip double-slip design that may be firmly anchored to the ground to prevent slipping stability and provide extra safety for the elderly and children. EASY TO CLEAN: Not only does this shoe sanitising floor mat maintain your interior sanitary and your flooring clean, but it is also simple to clean. Simply shake, vacuum, hose down, or toss in the washing machine, and it will be as good as new after each wash. EFFECTIVE LOW PROFILE DESIGN: The floor mat features a low profile design that lays flat on the floor and stays in place at all times. Its low clearance prevents it from catching under doors, while the looped material catches and traps infection-causing debris and mud.
1.Features: firm structure. low power consumption. small size. easy installation. vibration resistance. water vapor proof and dust proof 2.Application: It applies hall effect principle, can measure direct current, alternating current, pulse and current of various irregular wave forms in electrical isolation conditions. 3.Specification: Measuring frequency: 0-100KHz Accuracy: 0.2%-1% Responding time:
Nominal Current(RMS):200/400/800/1000/1200/2000A Vout@Ipn:+_4.000V Measuring Range:0~+_3000A Supply Voltage DC:+-12-15V Accurancy@Ipn,+25degree Celsius:less than +_0.5% Mounting(mm):12.5*41.0
Nominal Current(RMS):25/50/75/100A Vout@Ipn:+_25/50V Measuring Range:0~+_150A Supply Voltage DC:+-12-15V Accurancy@Ipn,+25degree Celsius:less than +_0.5% Mounting(mm):7.0*12.7  * Closed- loop                                        * Supply voltage: DC +-12~15V  * Capable measurement of currents: DC, AC,pulse with galvanic isolation between primary circuit and secondary circuit.
Input: AC 0.5A-5A; Output: DC 0-5V; Accuracy: 0.2%; Power supply: DC 9-36V.
Input: DC 10mV-1000V; Output: DC 4-20mA; Accuracy: 0.2%; Power supply: DC 12V, 24V.
Input: DC 10mV-1000V; Output: DC 4-20mA; Accuracy: 0.2%; Power supply: DC 12V, 24V.
Input: AC/DC 20-100A; Output: DC 4-20mA; Accuracy: 1.0%; Power supply: DC 12V, 15V, 24V.
Removing dead skin cells is very important for healthy looking skin, and the process is to reveal the newer smoother skin underneath. The spatula can effectively removes dead skin cells and clean the pores, so its good for all skin types, imperatively for oily to combination skin; and it is suitable for sensitive and rosacea skin. The spatula could be beneficial to acne skin as it will push everything to the surface, be sure to use distilled water while treating acne with the spatula. (spray the distilled water to the treated area, then run Ultrasound Skin Spatula over it). Another great thing about our Ultrasonic Facial Skin Spatula is that it can help water-soluble skincare products (gels, serum, ampoules) to penetrate to the skin. Keeping our skin hydrated is essential, especially for those of you who travel a lot, from one climate to another sometimes can confuse our skin. People who live in a dry climate might be easier to adapt the changes. But for someone lives in humid climate and switch to a dry environment can really challenge his/her skin. By using Ultrasonic Facial Skin Spatula, we can easily keep our skin hydrated while on the go. Remarkable Features Skin cleaning and dispel dead skin and skin dregs. Able to remove dirt within pores and aging cuticle. Improve skin quality for better lift-up, whitening and health. Nutrition penetration, Toxins and wrinkle removal. Repair body cells, speed up absorption of skin-care products. Painless, cleanliness, and deep skin cleansing. Decompose melanin, disinfect pimples and various skin problems. Shrinking skin pores to give glossy, shiny, white and healthy skin. Take away wrinkles and loosen skin. Skin Massage with ion penetration to keep smooth and ageless skin. Intelligent time control for each ten minutes treatment. Compact and portable design with low power consumption. A cordless device for convenient use. Specifications INPUT VOLTAGE : AC 90 !V 240V OUTPUT VOLTAGE : DC 5V 500mA Li-ion 3.7V 560 mAh MAXIMUM OPERATING CURRENT : 600mA OUTRASONIC OUTPUT FREQUENCY : 25KHz NET WEIGHT : 140g SIZE : 220 X 84 X 30 mm (8.65 X 3.3 X 1.1 inch)
3-phase4-wire AC Digital Transducer Product: 3-phase 4-wire ac multi-parameter digital transducer 1. Series: Ce-aj42-1----- 3-phase 4-wire, rs-485 interface, treble isolated (n case style only). Ce-aj42-2----- 3-phase 4-wire, rs-232c interface, treble isolated (n case style only). 2.Specifications: Input (measuring range)------ ac 45-65hz, voltage: 110v, 220v, 380v and 500v(or specially supply to meet user's other special requirement), current: 1a, 5a, 15a, 25a (or specially supply to meet user's other special requirement) Data output------rms of voltage ua, ub and uc; rms of current ia, ib and ic. Real value of frequency f. Other five parameters including active power p, reactive power q, power factor cosf, active energy and reactive energy are shown in the form of a percentage of the maximum value of its measurable range. Output interface------rs-485: two-wire connection, communication distance:1200m, +/- 15kv esd protection. Rs-232c: n case style connects directly through its terminals. Accuracy grade------ frequency: 0.05 hz. Voltage, current, power factor, active power, reactive power, active energy, reactive energy: 0.5%. (accuracy and linearity are ignored when the voltage is below 5%.) Baud rate------ 1200, 2400, 4800, 9600, 19.2k bps Refreshing period------ 250ms Isolation voltage------ 1000 v dc or 2500v dc Power consumption------
Series: ce-ij03 Ce-ij03a(true rms) Input range: 0.5a~300a Output: 5v or 4-20 ma Accuracy: 0.2% or 0.5% Response time: 300 ms Power source: +12v or +15v or +24v Load capability: voltage outputú5ma Current outputú300w Quiescent power consumption: 200 mw L*w*h=83mm*36mm*56mm
The CE-IJ03 1 element AC current transducer is designed to measure and monitor average RMS AC current, then produce a standard signal such as 4-20mADC, 0-5VDC and so on. Rated input: 0-500AAC(average RMS current ; TRMS current optional) Output signal: 0-5V;0-20mA;4-20mA;1-5V;4-20mA loop powered;0-10V; oc frequency(0-5kHZ,0-10KHZ) Power supply: +12VDC;+15VDC;+24VDC, self power optional Accuracy: 0.5% optional Output ripple: 15mV Isolation: 2500V DC Load resistance: Voltage Output >2kohm; Current Output=250ohm Overload capacity: 20 times or
Transducers, hall effect current transducer, true rms transducer, self-powered transducer, multi-parameter digital transducer.
The one element DC multi-parameter digital transducer is used for measuring DC current, voltage and power parameters.Its inputs are DC current (output of mating transducer) and DC voltage, and its outputs are digital data of the DC current, voltage and power through RS-485 interface. It can be applied to various measuring and controlling systems such as communication, power grid and electrization railway etc. Parameters Part numbers: CE-AD11-34MS3-0.5/0~500V 0~5A Description:Input: 0-500VDC,0-5ADC,Output interface: RS-485.MODBUS protocol,Power supply:24VDC(21~27V),Accuracy:0.5%,Window:none,Case style:S3 Part numbers: CE-AD11B-37MS5-0.5/0~1000V 0~5A Description:Input: 0-1000VDC,0-5ADC,Output interface: RS-485.MODBUS protocol,Power supply:+9~55V,Accuracy:0.5%,Window:none,Case style:S5 Specifications Voltage input: 0~25mA~500V DC (MS3) 0~25mA~1000V DC (MS5) Current input: 0~10mA~5A DC (Output of mating Hall Effect analog current transducer) Output data: DC Voltage, DC Current, DC Power (product of the voltage and current) Accuracy: 0.2% Baud rate: 1200, 2400, 4800, 9600 and 19.2K bps Refresh period: 100 mS Input overload: 2 times of full span (1 second, 10 times) Power supply: +24VDC(MS3) +9~55V(MS5) Static power consumption: £500 mW Operating temperature: 0~50°C Storage temperature: -55~+85°C Isolation voltage: >2500V DC Application: Digital data acquisition Automation system integrator Electrical distribution system Industrial automation engineering Process automation system
This is a DC voltage and current transducer. The operating principle is Photoelectric Isolation/Treble isolation. It can measure DC voltage and DC current at the same time, and has two channels of standard signal. The input, output and power supply are isolated from each other. It's featured in high accuracy, high isolation, low drift and so on. This product can be used in railway, industry control, and other fields. Rated input: 0~1-500V; 0~0.5-5A Output signal: 0~5V DC (Vz); 0~20mA (Iz); 4~20mA (Iy);0~10V DC (Vd);OC frequency output:(0-5KHz/0-10KHz) optional Power supply: 12V;15V; 24V; optional Accuracy: 0.5% optional Output ripple: 10mV Isolation: 2500V DC Humidity: â?¤95%(no dew) Load resistance: Voltage Output >2kohm; Current Outputâ?¤250ohm Temperature drift: 500/ppm Response time: â?¤200ms Operating temperature:: -10~+60 Quiescent power consumptio:
4-20 mA/0-5v/0-10v Output NH3 ammonia sensor Product Description Our NH3 sensor uses the electrochemical principle to detect the concentration of ammonia (NH3). The reaction is rapid, sensitive, low-power, high-precision, anti-interference, and has excellent repeatability and stability. This product is widely used in the detection of ammonia in industrial, mining and environmental protection. Analog signal output, 4~20mA, 0~5V, 0~10V optional, equipment 10~30V wide voltage supply. The enclosure rating is high and can be adapted to different environmental monitoring. Power supply 10~30V DC output signal 4~20mA0~5V0~10V Power consumption 0~50ppm accuracy (high precision) 0.25W 0~100ppm accuracy (high precision) 0.25W 0~500ppm 1W Operating temperature -20~+50 Working humidity 15%RH~90%RH Pressure range Standard atmospheric pressure ±10% Stability (months) ï¼?10% Response time 150S Zero drift (-20~40C) -3~10ppm (0~100ppm products) Repeatability 10%output value Service life 24 months Precision 0~50ppm accuracy (high precision) ±10%FS 0~100ppm accuracy (high precision) ±10%FS 0~500ppm ±20%FS±10ppm Oxygen content: 18% Resolution 0~50ppm model: 0.01ppm 0~100ppm model: 1ppm 0~500ppmmodel1ppm Detailed Images 1. High-sensitivity gas detection probe, stable signal, accurate measurement of NH3 concentration (PPM), high accuracy. 2.Avariety of measurement ranges, 0~50PPM, 0~100PPM, 0~500PPM. 3.Avariety of analog signal output options: 4~20mA, 0~5V, 0~10V. 4. The product adopts wall-mounted waterproof shell, which is easy to install and has high protection level. . Installation Instructions No output or output error possible reason: 1) The range corresponding error causes the PLC to calculate an error. 2) The wiring method is incorrect or the wiring sequence is wrong. 3) The power supply voltage is incorrect (24V power supply for 0~10V models). 4) The distance between the transmitter and the collector is too long, causing signal disturbance. 5) The PLC collection port is damaged. 6) Equipment damage. Notes 1) The aging test before use is not less than 48 hours; 2) Electrolyte leakage will cause injury, please do not disassemble the sensor at will; 3) The sensor should avoid contact with organic solvents, paints, chemicals, oils and high-concentration gases; 4) The sensor should not be immersed in an oxygen-free environment for a long time, otherwise it will damage the performance of the sensor; 5) It should not be used for a long time in an environment containing corrosive gases, corrosive gases will damage the sensor; 6) It is forbidden to store and use in high concentration alkaline gas for a long time; 7) The air inlet holes must not be blocked or contaminated. Our Services & Strength 1.OEM servie, we can design as your requirements. 2.2 years warranty for our sensors 3.We have CE,FCC,ISO,ROHS certificates. 4.We have sensor in stock, can delivery immediately.
Ip/ep converter Ip/ep transducer Electropneumatic transducer Input electrical current:4-20ma, 0-10v Output pressure:20-100kpa Et-500 is electropneumatic transducer equipment, it can decrease supply pressure to produce output pressre which is effectively proportional to input electric signal. Supply pressure range:125kpaí½1000kpa.With bulk augmenter supply big flow (20.4 m3/h). Features: Flow rate: 7.6m3/h when supply pressure is 175kpa 20.0m3/h when supply pressure is 700kpa Min/max. Supply pressure: Minimum-3psig(21kpa) above maximum output Maximum-100psig(700kpa) Sensitivity:
This device is designed to monitor AC leakage current, then produce a standard signal such as 4- 20mADC, 0-5VDC and so on. It can be applied to arrester state detection, insulation of some electrical equipments and leakage current detection. High overload capacity: This device can accept heavy current input which is up to 2000A and work in high voltage environment; High stability: This device can effectively suppress the interference; High safety: Great surge protection capacity and 35KV isolation. Rated input: 0~0.5-100mA AC optional Output signal: 0-5V;0-20mA;4-20mA optional Power supply: +12VDC;+15VDC;+24VDC optional Accuracy: 1% Output ripple: 2kohm; Current Outputâ?¤250ohm Temperature drift: â?¤400/ppm Response time: â?¤300ms Operating temperature: -20~+70 Quiescent power consumption: 360mW(with +12VDC power) Window size :Ã?20mm
Electropneumatic transducer Input electrical current:4-20ma, 0-10v Output pressure:20-100kpa Et-500 is electropneumatic transducer equipment, it can decrease supply pressure to produce output pressre which is effectively proportional to input electric signal. Supply pressure range:125kpaí½1000kpa.With bulk augmenter supply big flow (20.4 m3/h). Features: Flow rate: 7.6m3/h when supply pressure is 175kpa 20.0m3/h when supply pressure is 700kpa Min/max. Supply pressure: Minimum-3psig(21kpa) above maximum output Maximum-100psig(700kpa) Sensitivity: