Series: ce-ij03
Ce-ij03a(true rms)
Input range: 0.5a~300a
Output: 5v or 4-20 ma
Accuracy: 0.2% or 0.5%
Response time: 300 ms
Power source: +12v or +15v or +24v
Load capability: voltage outputú5ma
Current outputú300w
Quiescent power consumption: 200 mw
L*w*h=83mm*36mm*56mm
Attribute: Rated input current AC 30A, 50A, 100A, 150A, 200A, 250A, 300A, 350A, 400A AC Output signals 4-20mA DC Accuracy 0.5% Input Impedance (R) approximate zero Responding Time 300ms Linear measuring range 0 - 1.2 times of rated input current Over Load Capacity 30 times of rated input current, 5s Frequency range 25Hzï½?5kHz Output impedance 6V Static current 3.3mA(0mA-20mA) 6.8mA(4mA-20mA) Power supply +12V/+24V DC Isolation Voltage(Input/Output) â?¥2500Vdc, for 1 minute Output Ripple ï¼?6mV Thermal drift 350ppm/°C Ambient Temperature -10ï½?+50 Mounting DIN Rail 35mm Mounting or screw mounting Material of shell ABS (According to UL94V-0) Protection of shell IP20 Shell type with aperture Ф20mm MTBF >50000h Weight 120g
Supplier: Japanese quality switchgear components, breakers, magnetic contactors, switches, pilot lights, pushbuttons, panel instrumentations, power management meter, protection relays, transformers, inverters, ups.
Function & Feature 1. Have microcontroller technology as the core, using the latest algorithms, to achieve precise measurement. 2. Current transducer converts an ac current input into a load independent output signal. 3. Excellent temperature characteristic and good working stability. 4. The output signal is based on the a root mean square(rms) measurement of the input signal and hence the transducer can be used with distorted waveforms. 5. The unit conforms to IEC 60688. In an addition it meets the insulation requirements of IEC 60255-5, clauses 5, 6 and 8 as well as the high frequency disturbance test of IEC 60255-22 for Class III test voltage. Specifications Inputs: System current 1A, 5A, 10A, 30A Absorbed power 0.3VA Frequency range 50Hz, 60Hz Output: Standard nominal outputs 4~20mA, 0-5V, (others on request) 0-20mA, 5-10V 0-10V Ripple
This device is designed to monitor AC leakage current, then produce a standard signal such as 4- 20mADC, 0-5VDC and so on. It can be applied to arrester state detection, insulation of some electrical equipments and leakage current detection. High overload capacity: This device can accept heavy current input which is up to 2000A and work in high voltage environment; High stability: This device can effectively suppress the interference; High safety: Great surge protection capacity and 35KV isolation. Rated input: 0~0.5-100mA AC optional Output signal: 0-5V;0-20mA;4-20mA optional Power supply: +12VDC;+15VDC;+24VDC optional Accuracy: 1% Output ripple: 2kohm; Current Outputâ?¤250ohm Temperature drift: â?¤400/ppm Response time: â?¤300ms Operating temperature: -20~+70 Quiescent power consumption: 360mW(with +12VDC power) Window size :Ã?20mm
The CE-IJ03 1 element AC current transducer is designed to measure and monitor average RMS AC current, then produce a standard signal such as 4-20mADC, 0-5VDC and so on. Rated input: 0-500AAC(average RMS current ; TRMS current optional) Output signal: 0-5V;0-20mA;4-20mA;1-5V;4-20mA loop powered;0-10V; oc frequency(0-5kHZ,0-10KHZ) Power supply: +12VDC;+15VDC;+24VDC, self power optional Accuracy: 0.5% optional Output ripple: 15mV Isolation: 2500V DC Load resistance: Voltage Output >2kohm; Current Output=250ohm Overload capacity: 20 times or