Product Description
Our NH3 sensor uses the electrochemical principle to detect the concentration of ammonia (NH3). The reaction is rapid, sensitive, low-power, high-precision, anti-interference, and has excellent repeatability and stability. This product is widely used in the detection of ammonia in industrial, mining and environmental protection. Analog signal output, 4~20mA, 0~5V, 0~10V optional, equipment 10~30V wide voltage supply. The enclosure rating is high and can be adapted to different environmental monitoring.
Power supply
10~30V DC
output signal
4~20mA0~5V0~10V
Power consumption
0~50ppm accuracy (high precision) 0.25W
0~100ppm accuracy (high precision) 0.25W
0~500ppm 1W
Operating temperature
-20~+50
Working humidity
15%RH~90%RH
Pressure range
Standard atmospheric pressure ±10%
Stability (months)
ï¼?10%
Response time
150S
Zero drift (-20~40C)
-3~10ppm (0~100ppm products)
Repeatability
10%output value
Service life
24 months
Precision
0~50ppm accuracy (high precision) ±10%FS
0~100ppm accuracy (high precision) ±10%FS
0~500ppm ±20%FS±10ppm Oxygen content: 18%
Resolution
0~50ppm model: 0.01ppm
0~100ppm model: 1ppm
0~500ppmmodel1ppm
Detailed Images
1. High-sensitivity gas detection probe, stable signal, accurate measurement of NH3 concentration
(PPM), high accuracy.
2.Avariety of measurement ranges, 0~50PPM, 0~100PPM, 0~500PPM.
3.Avariety of analog signal output options: 4~20mA, 0~5V, 0~10V.
4. The product adopts wall-mounted waterproof shell, which is easy to install and has high
protection level. .
Installation Instructions
No output or output error
possible reason:
1) The range corresponding error causes the PLC to calculate an error.
2) The wiring method is incorrect or the wiring sequence is wrong.
3) The power supply voltage is incorrect (24V power supply for 0~10V models).
4) The distance between the transmitter and the collector is too long, causing signal disturbance.
5) The PLC collection port is damaged.
6) Equipment damage.
Notes
1) The aging test before use is not less than 48 hours;
2) Electrolyte leakage will cause injury, please do not disassemble the sensor at will;
3) The sensor should avoid contact with organic solvents, paints, chemicals, oils and high-concentration gases;
4) The sensor should not be immersed in an oxygen-free environment for a long time,
otherwise it will damage the performance of the sensor;
5) It should not be used for a long time in an environment containing corrosive gases,
corrosive gases will damage the sensor;
6) It is forbidden to store and use in high concentration alkaline gas for a long time;
7) The air inlet holes must not be blocked or contaminated.
Our Services & Strength
1.OEM servie, we can design as your requirements.
2.2 years warranty for our sensors
3.We have CE,FCC,ISO,ROHS certificates.
4.We have sensor in stock, can delivery immediately.
Input: AC 0.5A-5A; Output: DC 0-5V; Accuracy: 0.2%; Power supply: DC 9-36V.
Input: DC 10mV-1000V; Output: DC 4-20mA; Accuracy: 0.2%; Power supply: DC 12V, 24V.
Input: DC 10mV-1000V; Output: DC 4-20mA; Accuracy: 0.2%; Power supply: DC 12V, 24V.
Cheap Price Greenhouse Oem Analog co2 Carbon Dioxide Sensor with 0-10v output Product Description Our co2 sensor uses high sensitivity gas detection probe, signal stability, high precision. With a wide measuring range, good linearity, easy to use, easy to install, transmission distance and so on. Detailed Images Products keywords co2 sensor Supply power: 10~30V DC Signal output 4~20ma/0~5V/0~10V/RS485(Modbus-RTU) Protection level IP65, can be used for snow and rain environment Working environment 0 ~ 70 â??, 0 ~ 95% RH (no condensation) Temperature effects comes with temperature compensation CO2 Measurement range 0 ~ 5000ppm (can be customized) CO2 Accuracy �± (40ppm + 3% F �· S) (25 â??) Maximum power consumption RS485 0.4W 4-20ma/0-5v/0-10v 1.2W American brand chip, warranty 2years, communication distance 2000m. RS485 or 4-20ma,0-5v,0-10v for optional The transmitter adopts the new infrared verification technology to measure the CO2 concentration, and the reaction is quick and sensitive, avoiding the life of the traditional electrochemical sensor and the long-term drift problem. It is widely used in agricultural greenhouses, flower cultivation, edible fungi planting, etc., requiring CO2, temperature and humidity. The occasion of monitoring.Having Analog or 485 communication, standard ModBus-RTU communication protocol, communication address and baud rate can be set, the farthest communication distance is 2000 meters. The equipment is 10-30V wide-voltage power supply, and the enclosure has a high degree of protection, which can adapt to various harsh conditions on site. Electrical Wiring RS485 OUTPUT Line color Description power brown Power supply(10 ~ 30V DC) black Power supply negative Communication yellow 485-A blue 485-B Range 10V-30V of wide voltage is available in power input, the A wire and B wire can not be connected contrary when connecting to 485 signal, and the address among several devices on the total wire can not be conflicted. 4-20ma, 0-5v, 0-10v OUTPUT Line color Description Power brown Power supply black Power supply negative Output blue CO2 signal positive green CO2 signal negative NOTE: Two types wire methods 1.Four-wire connection diagram 2.Three-wire connection diagram
Input: AC/DC 20-100A; Output: DC 0-5V; Accuracy: 1.0%; Power supply: DC 12V, 15V, 24V.
Type Universal USB charger socket Charging Port 2 Ports Connection Universal USB charger socket Warranty 1 Year Combination Charger Socket Outlet Voltage 12-24v Model Number DS2014 Design Style New China-Chic Product name 4.2A Car Cigarette Lighter Socket Splitter Dual USB Charger Material ABS Input Voltage 12V-24V USB output 4.2A Size 3.7*5.4*2.9cm/1.5*2.12*1.14inch LED Blue LED Waterproof grade IP65 Working temperature Min.-20 Celsius Degree, Max. 80 Celsius Degree
PE coil pipes and tubes for water and wire cable conduit PL231 The PE coil pipes and tubes can be used: water pipe 4 â?? 6 â?? 1-inch black coil with pressure 1.6mpa, OD 20-75mm, WT 2.3-6.8mm pe conduit cable embedded wire cable and optical cable, OD 20-200mm, WT 1.8-3.5mm weak current protection tube and communication tube, OD 20-200mm, WT 1.8-3.5mm We use new 100% pure raw PE material WHY NEW MATERIAL HDPE PIPES? 1. Health performance PE pipe processing without adding heavy metal salt stabilizer, no scaling layer, and no bacteria. 2. Corrosion resistance It can resist various chemical media erosion, with no electrochemical corrosion. 3. Service life Under rated temperature and pressure conditions, PE pipes can be used for more than 50 years. 4. Impact resistance PE pipe toughness, high impact strength, heavy objects directly pressed through the pipeline will not break. 5. Connection performance The strength of the hot melt or electric melt interface of the polyethylene HDPE pipe is higher than that of the pipe body, and the joint will not be broken due to soil movement or live load. 6. Construction performance It has a lightweight pipe weight, a simple welding process, convenient construction, and a low overall project cost.
NH3 3E 100 Ammonia Sensor (NH3 Sensor) FEATURES * Amperometric 3 electrode sensor cell * Fixed organic gel electrolyte * No CO2 interference * 0 volt bias operation NH3 3E 100 Ammonia Sensor (NH3 Sensor) TYPICAL APPLICATIONS * TLV-monitoring, leakage detection * Fixed point applications in cold storages & refrigeration plants only * For other applications please use NH3 3E SE versions * No background concentrations of ammonia & alcohols NH3 3E 100 Ammonia Sensor (NH3 Sensor) TECHNICAL SPECIFICATIONS * Measuring Range: 0-100 ppm * Sensitivity Range: 90 nA/ppm ± 40 nA/ppm * Zero Current at 20 deg C: < ± 150 nA * Resolution at 20 deg C: < 2 ppm * Bias Potential: 0 mV * Linearity:
NH3-A1 Ammonia Sensor NH3 Sensor Description Alphasense is expanding its line of electrochemical toxic gas sensors to address industry-specific requirements, including emissions monitoring, process safety, environmental monitoring and VOCs. Ammonia (NH3) Our first family of Ammonia sensors. This sensor is designed for higher concentrations of Ammonia. Sensors for lower level detection are in development. NH3-A1 Ammonia Sensor NH3 Sensor Specifications * Range: 200 ppm NH3 limit of performance warranty * Sensitivity: 17 to 27 nA/ppm in 50ppm NH3 * Response time t90: