Nominal Current(RMS):200/400/800/1000/1200/2000A
Vout@Ipn:+_4.000V
Measuring Range:0~+_3000A
Supply Voltage DC:+-12-15V
Accurancy@Ipn,+25degree Celsius:less than +_0.5%
Mounting(mm):12.5*41.0
Nominal Current(RMS):25/50/75/100A Vout@Ipn:+_25/50V Measuring Range:0~+_150A Supply Voltage DC:+-12-15V Accurancy@Ipn,+25degree Celsius:less than +_0.5% Mounting(mm):7.0*12.7  * Closed- loop                                        * Supply voltage: DC +-12~15V  * Capable measurement of currents: DC, AC,pulse with galvanic isolation between primary circuit and secondary circuit.
Nominal Current(RMS):30/300A Vout@Ipn:2.500+_2.000V Measuring Range:+_30/+_300A Supply VoltaIpn,+25
Nominal Current(RMS):10/25/50/75A Vout@Ipn:2.500+_0.625V Measuring Range:0~+_150A Supply Voltage DC:+5V Accurancy@Ipn,+25degree Celsius:less than +_0.5% Mounting(mm):8.2 in diameter
Nominal current(rms):50/100/200/300/400/600a Voutipn:+4.000v Measuring range:0~+900a Supply voltage dc:+15v Accurancyipn, +25degree Celsiusless than1.0% Mounting(mm):10.5*20.5 * open- loop supply voltage: dc +15.0v * capable measurement of currents: dc, ac, pulse with galvanic isolation between primary circuit and secondary circuit.
Nominal Current(RMS):50/100/200/300/400/600A Vout@Ipn:+_4.000V Measuring Range:0~+_900A Supply Voltage DC:+_12-15 Accurancy@Ipn,+25degree Celsius:less than +_1.0% Mounting(mm):10.5*20.5
Type : RTCS100B,RTCS200B,RTCS300B,RTCS400B,RTCS500B,RTCS600B, IPN Primary nominal input current : 100, 200, 300, 400, 500, 600 A IP Measuring range of primary current : 0~300, 0~600, 0~900, 0~900, 0~900, 0~900 A VOUT Nominal output voltage : 41%V VC Supply voltage : 15(5%) V IC Current consumption : VC=15V
Nominal Current(RMS):200/400/800/1000/1200/2000A Vout@Ipn:+_4.000V Measuring Range:0~+_4000A Supply Voltage DC:+-12-15V Accurancy@Ipn,+25degree Celsius:less than +_1.0% Mounting(mm):40.5 in diameter * Open- loop * Supply voltage: DC +-12~15V * Capable measurement of currents: DC, AC,pulse with galvanic isolation between primary circuit and secondary circuit.
Rated input current AC 50A, 100A, 400A AC/DC Accuracy 1.0 Input Impedance (R) approximate zero Linear measuring range 0 - 1.2 times of rated input current Over Load Capacity 30 times of rated input current, 5s Frequency range 25Hzï½?5kHz Isolation Voltage(Input/Output) â?¥2500Vdc, for 1 minute Thermal drift 600ppm/°C Ambient Temperature -25ï½?+70 Mounting DIN Rail 35mm Mounting or screw mounting
Rated input current AC 50A, 100A, 400A AC/DC Accuracy 1.0 Input Impedance (R) approximate zero Linear measuring range 0 - 1.2 times of rated input current Over Load Capacity 30 times of rated input current, 5s Frequency range 25Hz~5kHz Isolation Voltage(Input/Output) 2500Vdc, for 1 minute Thermal drift 600ppm/ Ambient Temperature -25~+70 Mounting DIN Rail 35mm Mounting or screw mounting