The on-load tap changer is the only moving part connected with the transformer circuit so more and more attention has been paid to the detection of the on-load tap changer.In the electrical equipment handover and preventive test regulations it is required to check the action sequence of on-load tap changer measure switching time etc.This device is mainly used for measuring the transition waveform transition time transient resistance of transformer on-load tap changer three-phase synchronism etc. product names On - load tap - changer tester transformer on - load tap - changer tester transformer on - load switch tester
product Characteristics 1 Instrument output current light weight 2 Two current output wider test range higher stability 3 It can calculate the transition resistance value and transition time value automatically 4 Has the perfect protection circuit the reliability is strong 5 5.7 "large LCD display easy to operate on site 6 With usb flash disk storage function you can store more data waveform 7 The keyboard and the one-key flying shuttle operate independently making the instrument operate more quickly and conveniently
Introduction: The tester can record switch operation waveform in overall process. The longest time is 6.4s.It can test various parameters such as transition waveform, transition time, transition resistance and three phase synchronization one time and analyze results automatically. It has power-off protection, over-voltage protection, perpetual clock and high-speed printing. Functions: 1. Test transformers of type Y0 Y and display resistance value directly; 2. Automatically analyze waveform fault and mark the fault. 3. Automatically adjust resistance value and time range according to sampling data 4. Transformer type is able to display to synchronization status of three phase; 5. Be able to test with winding or without winding; 6. Four terminal connection mode and provide high accuracy of resistance measurement. 7. Continuous test to save time of power off 8. Make word report 9. 800Ã?480 colorized LCD with touch screen and high speed printer 10. Store 1000 groups of data and also can be saved by USB flash disk Technical Index: 1. Three phase constant current source charge,charge current: 3A/1A; 0.6A/0.2A 2. Maximum voltage of the port: 24V 3. Maximum range of transition resistance: 100 4. Measuring range: 1A:0.4~20 0.2A:10~100 5. Record time of waveform:300ms 6. Sample rate: 30k 7. Resolution of time:0.1ms 8. Resolution of resistance: 0.1 9. Accuracy of transition resistance: ±5% Reading±0.1 10. Accuracy of transient time: ±0.5% Reading±0.2mS 11. Temperature: -10-40°C Humidity:
The on-load tap changer is the only moving part connected with the transformer circuit so more and more attention has been paid to the detection of the on-load tap changer.In the electrical equipment handover and preventive test regulations it is required to check the action sequence of on-load tap changer measure switching time etc.This device is mainly used for measuring the transition waveform transition time transient resistance of transformer on-load tap changer three-phase synchronism etc.
GDKF Transformer Load and No Load Tester Introduction: It's used to Measure the transformer load and no load current, load and no load loss, short-circuit voltage, short circuit (load) losses and capacity. Test items: RMS phase voltage Average value of three-phase AC voltage Three-phase current RMS Percentage of no-load loss and no-load current Load loss, impedance voltage, and the percentage of short-circuit impedance Any given temperature, load loss, the percentage impedance voltage and short circuit impedance Voltage waveform in the percentage of each harmonic component Current waveform in the percentage of each harmonic component Technical index: Current measurement range: 100mA ~ 5A, accuracy class 0.2; Voltage Range: 10V ~ 650V, accuracy class 0.2; External transformer can broaden the scope of measurement instruments; Frequency Range: 40 ~ 65Hz, accuracy class 0.2; Power Input: AC220V ± 10% Company Information Our company has become one of the leading manufacturer of petroleum testing instrument and electrical testing instrument since 2009sâ??. We have developed sales channels in many countries such as Malaysia,India,Germany,USA,Mexico,Saudi Arabia,South Africa and other countries worldwide. and we have gained great advantage and high reputation in international market. We are making effort to develop together with customers from both domestic and abroad on the basis of reciprocity.Client,quality and service are our supreme target. Our Services Pre-sale Service: Inquiry will be replied within 24 hours. Welcome to visit our factory. Technical datas and operation manual sent for evaluation. After-sale Service: Training how to instal the machine, training how to use the machine at our factory; Engineers available to service machinery overseas at customers' cost;GDKF Transformer Load And No Load Capacity Characteristic Tester
Product description Current transformer field tester was developed with high-end testing technology, large-scale electronic circuit design and accord with national related protocol . It has solved the problem of big working intensity,trival operation while on-site test of current transformer, voltage transformer. Meanwhile the product has a reliable performance,and the function is strong. Technical index Test range: 5A5A~25000A5A or 5A1A~5000A1A Tested current transformer work scope: 1% 120% Second load 2.5 VA 300VA, COS 0.8 1.0 Be tested current transformer accuracy range 1.0, 0.5, 0.5 S, 0.2 and 0.2 S Resistance, admittance measurement errors 5.0% Measurement range R 0.00 ~20.0 Y 0.000mS~100.0 mS Power consumption 20 VA Accuracy level 0.05 S level Shape dimension mm 460 L 375 W 183H Weight kg 10 Feature HCCT-H Current Transformer Field Tester with recursive method to measure current transformer error, as well as potential difference method to measure voltage transformer error function, convenient for carrying out calibration work of field metering device. HCCT-H Current Transformer Field Tester without using Standard Current Transformer, Current Source, Load Box, Double Adjustable Control Box and Primary cable, using extremely simple test connection and operation to realize the current transformer test, greatly reduce work intensity and improve the work efficiency, convenient to carry out current transformer field test work.
Introduction 3 phase transformer on-load tap changer testeris mainly used to test three-phase transient time, transition waveform, transition resistance, synchronization state, etc. The transformer on-load switch tester is a comprehensive transformer on-load switch measurement and tester, which is used to measure and analyze the electrical performance indicators of power transformers and special transformers on-load tap-changers. The transformer on-load switch tester can automatically capture and display the transition resistance during the transition process. There is also a process of time jumping. Technical parameters Three phase constant current source charge,charge current: 3A/1A; 0.6A/0.2A Maximum voltage of the port: 24V Maximum range of transition resistance: 100 Measuring range: 1A 0.4 20 0.2A 10 100 Record time of waveform:300ms Sample rate: 30k Resolution of time:0.1ms Resolution of resistance: 0.1 Accuracy of transition resistance: ±5% Reading±0.1 Accuracy of transient time: ±0.5% Reading±0.2mS Temperature: -10-40 Humidity:
Product Name : Dehydrated Garlic Powder (A/ B/ C Grade) HS Code : 07129020 Packaging Options : 20/25 Kgs PP Bag/Cartoon Box or Customized Loading Option : 14 MTS (20 FT), 25 MTS (40FT) Aroma : Strong Spicy Size : 100 to 120 Mesh Product Expiry ; 2 Years in 5C - 12C Storage at Dry Place Source / Origin : India Garlic (Allium sativum) is a strong-smelling, pungent-tasting herb noted by early civilizations for its multiple health benefits. Because of these benefits, garlic is also used as a staple food item and used in our daily meals. However, fresh garlic can be consumed as raw with vegetable and fruit salads, sandwiches, and burgers or can be fried and use in curries or the gravy for better taste. Garlic adds an aromatic pungency and strong nutty savor of spice to any dish. This not only improves the taste and odor of any cuisine but also has many other benefits like the guaranteed transformation of any bland food/meal into a bold, spicy, aromatic, and healthy culinary experience with refreshed feelings. The dehydrated garlic flakes are prepared or obtained by processing the fresh garlic lumps. The dry products are hustle free to use and less pungent lighter aroma than fresh garlic. Although these garlic flakes are better substitutes for fast cooked meals as it brings equal taste and aroma to the food. In some dishes, the large dimensioned or bigger sized dried garlic flakes are not suitable, i.e., does not give the best look or does not get mixed completely with the food. Therefore, a finer and smooth product, i.e., the garlic powder, is considered. The dehydrated garlic powder is prepared or manufactured from the dried garlic flakes, outsize remaining materials or byproducts produced during the processing of Garlic Minced, Chopped, and Granule varieties. At first, it is processed through a grinding machine, and then, it is passed through the Vibro table fitted with the net size of below 100 orv120 mesh. This obtained garlic powder is also known as Dehydrated Garlic Powder. The commonly used dried powdered garlic is creamy- yellow colored and plentily produced by the Sky Agri Export. This dried garlic powder is highly demanded by many Asian and European countries, middle-east Africa, Russia, and North America. PHYSICAL ANALYSIS Appearance : Yellowish to brownish Size : 100 to 120 Mesh Texture : Powder Taste/Flavour : Characteristic aroma, fragrant and pungent CHEMICAL ANALYSIS Moisture Content : 8.0 % Max Total Ash on dry basis : 5.0 % Max Ash Insoluble in dil HCL : 0.5 % Max Peroxide : Negative MICROBIOLOGICAL ANALYSIS Total Viable Count (CFU/g) :
Product description The current booster is used on checking current transformer,to be the power source supply once current for current transformer or to be other 50Hz single phase current source device. Technical index Temperature Humidit Capacity: 20kVA Specification Weight: 75Kg Allow long-term work on the rated current Allowable overload 1.5 times,30 minutes of continuous work. Feature This PSLLQ is make up of input Winding(220V), output winding below 100A and CXRZ. Output current indicated on the nameplate is defined the rated current that through winding allow to pass.When CX many circles, the rated current its permitted to pass through will inversely decline. The value which ouput capcity divided by product of output current and each circle voltage was the biggest circle number allowing. The current booster is designed to provide the primary current power supply for the current transformer when verifying the current transformer or as other 50HZ single-phase power equipment. The current booster for transformer verification is suitable for power departments such as power testing, power measurement, and power maintenance. The current booster is developed and produced according to the industry standard of transformer error testing, and is used as a current transformer to verify the primary current of the current transformer. The output current can be customized according to customer requirements. The lifter is equipped with casters for easy on-site movement.
The on-load tap changer is the only moving part connected with the transformer circuit so more and more attention has been paid to the detection of the on-load tap changer.In the electrical equipment handover and preventive test regulations it is required to check the action sequence of on-load tap changer measure switching time etc.This device is mainly used for measuring the transition waveform transition time transient resistance of transformer on-load tap changer three-phase synchronism etc.
Product description Current transformer field tester was developed with high-end testing technology, large-scale electronic circuit design and accord with national related protocol . It has solved the problem of big working intensity,trival operation while on-site test of current transformer, voltage transformer. Meanwhile the product has a reliable performance,and the function is strong. Technical index
Product Introduction This product is specially used for measuring the capacity of distribution power transformer measuring the no-load and short-circuit loss of transformer and has the function of harmonic analysis which is convenient for analyzing the quality of on-site power network. The device can automatically check whether the wiring is correct and display the vector diagram of the three-phase current and voltage when testing the three-phase transformer. At the same time necessary correction (such as waveform correction temperature correction unrated voltage correction calibration unrated current correction) is introduced to make the test results more accurate. Product name Transformer capacity test instrument transformer capacity load tester
Manufacturer of off-load tapping switch, transformer tapping switch, 11 KV / 22 KV / 33 KV, 30 Amps / 60 Amps / 100 Amps / 150 Amps / 250 Amps / 400 Amps, 5 Positions / 7 Positions / 9 Positions / 11 Positions, Bridge Type, Tie Road Type, Suitable for Different Mounting Positions, With Universal Coupling Type Handle or Bevel Gear Type.
FYSeries current and voltage Transformer Load Box is specially provided for various payloads when testing current and voltage transformers and it is an ideal matching product for various transformer verification devices.The Transformer Load Box is in strict accordance with the national standard jjg313-94 JJG314-94 design for.Its Transformer Load Box output capacity is large Full range of loads in light weight good-looking appearance Stability and other advantages. Product nickname Transformer Load Box Voltage Transformer Load Box Current Transformer Load Box Voltage load box Current load box Voltage load box Current load box
Product brief introduction Product Introduction FYSeries current and voltage Transformer Load Box is specially provided for various payloads when testing current and voltage transformers and it is an ideal matching product for various transformer verification devices.The Transformer Load Box is in strict accordance with the national standard jjg313-94 JJG314-94 design for.Its Transformer Load Box output capacity is large Full range of loads in light weight-looking appearance Stability and other advantages.
On Load Tap-changer,
On-load Tap-changer,
Off Load Tap-changer,Tap Changer
Transformer Capacity and Loss Tester Transformer Oil Tester I Introduction Transformer Capacity Testing Instrument is specialized in bad power users evading basic electricity secretly adds capacity problems and is a high precision instrument specially used for the measurement of the transformer capacity and parameters. This product uses color LCD monitor, English display, simple and quick menu operation, man-machine interface is friendly. The internal of the instrument has a rechargeable battery and it can work without external power source. A fully charged battery can be continuously measured more than 100 sets. In addition, the instrument can provide three-phase precise 50Hz sine wave AC test power without the external three-phase test power, the pressure regulator, up flow reactor and other auxiliary equipment in measuring the capacity and transformer load loss, thus greatly improving the efficiency of the work. This is a multi-functional measuring instrument, which is equivalent to two common devices: activity transformer capacity tester and transformer parameter tester. It can be used for test transformer capacity, model, no-load current, no-load loss, load loss, impendence voltage and so on. This product has many advantages such as small, light , high accuracy, stability, simple operation and so on. It can replace the multi-meter method to measure the transformer loss and capacity with simple wiring and convenient testing so that the work efficiency can be greatly improved. Function 1. We can measure a variety of distribution transformer, power transformer capacity instead of the additional power. It is more convenient and efficient. 2.Combined with the power, voltage, boost up flow and other equipment, it measures various transformer no-load current, no-load loss, impedance voltage, load loss and so on. 3.All results are automatically carried out relevant correction. You only need to input the related parameters (such as temperature, load adjustment coefficients), then the instrument can automatically correct such as waveform deformity correction, temperature correction, correction of non rated voltage, rated current correction. 4.The maximum voltage is up to 750V and the maximum current is up to 100A. It is equipped with protection circuit. 5.The voltage and current range can be very flexible and easy to expand. 6.It has large screen, high brightness LCD display, English menu and operation tips, friendly man-machine interface and wide temperature, brightness adjustable type LCD screen, which can adapt to the different temperature.
BTLT-1 Glass Bottle Top Load Tester --- Maximum Top Load Resistance Tester for Glass Bottles The BTLT-1 is an instrument for testing the resistance to Top load effort on glass containers. It has been widely used by the glass container manufacturers and users. As a standard testing instrument for the glass container industry, it offers an important technical reference to the manufacturers for maintaining or improving the product quality and performance. Designed for easy operation and maintenance, comply with the testing standard of ISO 8113:2004. The top load test of containers is made up to a predefined pressure point (trial test) or until destruction. Characteristics: • User defined test cycle (up to 4 steps of pressure and holding time) satisfies different test request • PLC integrated & Touch screen control • Easy operation • Can store 10 operators and 30 products • User define the product lot number and sequence number • Reviews the real-time testing curve • Custom-made inserts for different types of samples, easier for sample installation and more accurate on pressure point. • Lifting platform height adjustable accordingly to samples • Lifting platform speed adjustable • AT2E Patented trash bin design, more safety for operating and easier for scrap cleaning • Maximum top load pressure up to 2200 Kgf / 22000 N • Stainless steel frame and aluminum parts, more sturdy and durable. • Overload protection • Advanced safe door design ensures the safety of operator during a test. • RS232 output interface, can be connected to printer or data acquisition software