Product Introduction
This product is specially used for measuring the capacity of distribution power transformer measuring the no-load and short-circuit loss of transformer and has the function of harmonic analysis which is convenient for analyzing the quality of on-site power network. The device can automatically check whether the wiring is correct and display the vector diagram of the three-phase current and voltage when testing the three-phase transformer. At the same time necessary correction (such as waveform correction temperature correction unrated voltage correction calibration unrated current correction) is introduced to make the test results more accurate.
Product name Transformer capacity test instrument transformer capacity load tester
GDKF Transformer Load and No Load Tester Introduction: It's used to Measure the transformer load and no load current, load and no load loss, short-circuit voltage, short circuit (load) losses and capacity. Test items: RMS phase voltage Average value of three-phase AC voltage Three-phase current RMS Percentage of no-load loss and no-load current Load loss, impedance voltage, and the percentage of short-circuit impedance Any given temperature, load loss, the percentage impedance voltage and short circuit impedance Voltage waveform in the percentage of each harmonic component Current waveform in the percentage of each harmonic component Technical index: Current measurement range: 100mA ~ 5A, accuracy class 0.2; Voltage Range: 10V ~ 650V, accuracy class 0.2; External transformer can broaden the scope of measurement instruments; Frequency Range: 40 ~ 65Hz, accuracy class 0.2; Power Input: AC220V ± 10% Company Information Our company has become one of the leading manufacturer of petroleum testing instrument and electrical testing instrument since 2009sâ??. We have developed sales channels in many countries such as Malaysia,India,Germany,USA,Mexico,Saudi Arabia,South Africa and other countries worldwide. and we have gained great advantage and high reputation in international market. We are making effort to develop together with customers from both domestic and abroad on the basis of reciprocity.Client,quality and service are our supreme target. Our Services Pre-sale Service: Inquiry will be replied within 24 hours. Welcome to visit our factory. Technical datas and operation manual sent for evaluation. After-sale Service: Training how to instal the machine, training how to use the machine at our factory; Engineers available to service machinery overseas at customers' cost;GDKF Transformer Load And No Load Capacity Characteristic Tester
The on-load tap changer is the only moving part connected with the transformer circuit so more and more attention has been paid to the detection of the on-load tap changer.In the electrical equipment handover and preventive test regulations it is required to check the action sequence of on-load tap changer measure switching time etc.This device is mainly used for measuring the transition waveform transition time transient resistance of transformer on-load tap changer three-phase synchronism etc.
FYSeries current and voltage Transformer Load Box is specially provided for various payloads when testing current and voltage transformers and it is an ideal matching product for various transformer verification devices.The Transformer Load Box is in strict accordance with the national standard jjg313-94 JJG314-94 design for.Its Transformer Load Box output capacity is large Full range of loads in light weight good-looking appearance Stability and other advantages. Product nickname Transformer Load Box Voltage Transformer Load Box Current Transformer Load Box Voltage load box Current load box Voltage load box Current load box
Product brief introduction Product Introduction FYSeries current and voltage Transformer Load Box is specially provided for various payloads when testing current and voltage transformers and it is an ideal matching product for various transformer verification devices.The Transformer Load Box is in strict accordance with the national standard jjg313-94 JJG314-94 design for.Its Transformer Load Box output capacity is large Full range of loads in light weight-looking appearance Stability and other advantages.
The on-load tap changer is the only moving part connected with the transformer circuit so more and more attention has been paid to the detection of the on-load tap changer.In the electrical equipment handover and preventive test regulations it is required to check the action sequence of on-load tap changer measure switching time etc.This device is mainly used for measuring the transition waveform transition time transient resistance of transformer on-load tap changer three-phase synchronism etc.
The on-load tap changer is the only moving part connected with the transformer circuit so more and more attention has been paid to the detection of the on-load tap changer.In the electrical equipment handover and preventive test regulations it is required to check the action sequence of on-load tap changer measure switching time etc.This device is mainly used for measuring the transition waveform transition time transient resistance of transformer on-load tap changer three-phase synchronism etc. product names On - load tap - changer tester transformer on - load tap - changer tester transformer on - load switch tester
Transformer Capacity and Loss Tester Transformer Oil Tester I Introduction Transformer Capacity Testing Instrument is specialized in bad power users evading basic electricity secretly adds capacity problems and is a high precision instrument specially used for the measurement of the transformer capacity and parameters. This product uses color LCD monitor, English display, simple and quick menu operation, man-machine interface is friendly. The internal of the instrument has a rechargeable battery and it can work without external power source. A fully charged battery can be continuously measured more than 100 sets. In addition, the instrument can provide three-phase precise 50Hz sine wave AC test power without the external three-phase test power, the pressure regulator, up flow reactor and other auxiliary equipment in measuring the capacity and transformer load loss, thus greatly improving the efficiency of the work. This is a multi-functional measuring instrument, which is equivalent to two common devices: activity transformer capacity tester and transformer parameter tester. It can be used for test transformer capacity, model, no-load current, no-load loss, load loss, impendence voltage and so on. This product has many advantages such as small, light , high accuracy, stability, simple operation and so on. It can replace the multi-meter method to measure the transformer loss and capacity with simple wiring and convenient testing so that the work efficiency can be greatly improved. Function 1. We can measure a variety of distribution transformer, power transformer capacity instead of the additional power. It is more convenient and efficient. 2.Combined with the power, voltage, boost up flow and other equipment, it measures various transformer no-load current, no-load loss, impedance voltage, load loss and so on. 3.All results are automatically carried out relevant correction. You only need to input the related parameters (such as temperature, load adjustment coefficients), then the instrument can automatically correct such as waveform deformity correction, temperature correction, correction of non rated voltage, rated current correction. 4.The maximum voltage is up to 750V and the maximum current is up to 100A. It is equipped with protection circuit. 5.The voltage and current range can be very flexible and easy to expand. 6.It has large screen, high brightness LCD display, English menu and operation tips, friendly man-machine interface and wide temperature, brightness adjustable type LCD screen, which can adapt to the different temperature.
Modulating Capacity Transformer Special Transformer Modulating capacity transformer is one kind of distribution transformers, which has two capacities ( one is small , another one is large) and can adjust according to the load size. The changing of high voltage winding connection mode, the conversion of low voltage winding parallel series and the adjustment of every connection are finished by special no excitation modulating capacity switch. Meanwhile, when large capacity is adjusted to small capacity, no-load loss and no-load current will be reduced because the increasing of low voltage turns and the decrease of coreâ??s magnetic flux density reduce unit loss of silicon steel, thus reaches the purpose of lowing loss and energy-saving. Double voltage distribution transformer has one small and one large voltage, and can adjust according to electric grids voltage. The conversion of high voltage winding parallel series and the adjustment of every connection are finished by special no excitation modulating capacity switch.  General introduction SZ11-T load modulating capacity transformer is one kind of distribution transformers with new technology and energy-saving. It has two kinds rated capacity, one is small and another one is large, and the operation mode of these two capacity can be automatically converted which solves the problem of transformersâ?? large loss caused by relatively large changes of 10 kV distribution grids seasonable magnitude, and also solve the operational maintain problem because capacity must be adjusted by hand after the outage of no-load modulating capacity transformer power . Modulating capacity transformer not only suits rural electric grids which seasonable magnitude changes are relatively large, but also suits downtown, development zones, industrial zones and other distribution work area where circadian load changes are obvious.  Working principle Load modulating capacity transformer is adjusted by the intelligent controller externally modulating- switches, thus completing the convert process of high capacity and low capacity, more details as below: intelligent controller determines the current load size by detecting transformers voltage and current of low voltage side; determines related constraints based on the capacity setting value; if meet the setting conditions, intelligent controller will issue the corresponding control commands to load modulating capacity switch, then modulating capacity switch can finish the star ,angle change and the parallel series convert of transformer s inner high voltage winding, low voltage winding; completes the process of capacity adjustment under conditions with power.
Single Phase, Double Wound Transformer Capacity - BRAND - VIJAYANTA, INDIA 1. Single Phase, Double Wound Transformer Capacity : 1 KVA, 2 KVA.