Transformer Capacity and Loss Tester
Transformer Oil Tester
I Introduction
Transformer Capacity Testing Instrument is specialized in bad power users evading basic electricity secretly adds capacity problems and is a high precision instrument specially used for the measurement of the transformer capacity and parameters. This product uses color LCD monitor, English display, simple and quick menu operation, man-machine interface is friendly. The internal of the instrument has a rechargeable battery and it can work without external power source. A fully charged battery can be continuously measured more than 100 sets. In addition, the instrument can provide three-phase precise 50Hz sine wave AC test power without the external three-phase test power, the pressure regulator, up flow reactor and other auxiliary equipment in measuring the capacity and transformer load loss, thus greatly improving the efficiency of the work.
This is a multi-functional measuring instrument, which is equivalent to two common devices: activity transformer capacity tester and transformer parameter tester. It can be used for test transformer capacity, model, no-load current, no-load loss, load loss, impendence voltage and so on.
This product has many advantages such as small, light , high accuracy, stability, simple operation and so on. It can replace the multi-meter method to measure the transformer loss and capacity with simple wiring and convenient testing so that the work efficiency can be greatly improved.
Function
1. We can measure a variety of distribution transformer, power transformer capacity instead of the additional power. It is more convenient and efficient.
2.Combined with the power, voltage, boost up flow and other equipment, it measures various transformer no-load current, no-load loss, impedance voltage, load loss and so on.
3.All results are automatically carried out relevant correction. You only need to input the related parameters (such as temperature, load adjustment coefficients), then the instrument can automatically correct such as waveform deformity correction, temperature correction, correction of non rated voltage, rated current correction.
4.The maximum voltage is up to 750V and the maximum current is up to 100A. It is equipped with protection circuit.
5.The voltage and current range can be very flexible and easy to expand.
6.It has large screen, high brightness LCD display, English menu and operation tips, friendly man-machine interface and wide temperature, brightness adjustable type LCD screen, which can adapt to the different temperature.
Product description Current transformer field tester was developed with high-end testing technology, large-scale electronic circuit design and accord with national related protocol . It has solved the problem of big working intensity,trival operation while on-site test of current transformer, voltage transformer. Meanwhile the product has a reliable performance,and the function is strong. Technical index Test range: 5A5A~25000A5A or 5A1A~5000A1A Tested current transformer work scope: 1% 120% Second load 2.5 VA 300VA, COS 0.8 1.0 Be tested current transformer accuracy range 1.0, 0.5, 0.5 S, 0.2 and 0.2 S Resistance, admittance measurement errors 5.0% Measurement range R 0.00 ~20.0 Y 0.000mS~100.0 mS Power consumption 20 VA Accuracy level 0.05 S level Shape dimension mm 460 L 375 W 183H Weight kg 10 Feature HCCT-H Current Transformer Field Tester with recursive method to measure current transformer error, as well as potential difference method to measure voltage transformer error function, convenient for carrying out calibration work of field metering device. HCCT-H Current Transformer Field Tester without using Standard Current Transformer, Current Source, Load Box, Double Adjustable Control Box and Primary cable, using extremely simple test connection and operation to realize the current transformer test, greatly reduce work intensity and improve the work efficiency, convenient to carry out current transformer field test work.
Product description The current booster is used on checking current transformer,to be the power source supply once current for current transformer or to be other 50Hz single phase current source device. Technical index Temperature Humidit Capacity: 20kVA Specification Weight: 75Kg Allow long-term work on the rated current Allowable overload 1.5 times,30 minutes of continuous work. Feature This PSLLQ is make up of input Winding(220V), output winding below 100A and CXRZ. Output current indicated on the nameplate is defined the rated current that through winding allow to pass.When CX many circles, the rated current its permitted to pass through will inversely decline. The value which ouput capcity divided by product of output current and each circle voltage was the biggest circle number allowing. The current booster is designed to provide the primary current power supply for the current transformer when verifying the current transformer or as other 50HZ single-phase power equipment. The current booster for transformer verification is suitable for power departments such as power testing, power measurement, and power maintenance. The current booster is developed and produced according to the industry standard of transformer error testing, and is used as a current transformer to verify the primary current of the current transformer. The output current can be customized according to customer requirements. The lifter is equipped with casters for easy on-site movement.
Product description Current transformer field tester was developed with high-end testing technology, large-scale electronic circuit design and accord with national related protocol . It has solved the problem of big working intensity,trival operation while on-site test of current transformer, voltage transformer. Meanwhile the product has a reliable performance,and the function is strong. Technical index
Product Introduction This product is specially used for measuring the capacity of distribution power transformer measuring the no-load and short-circuit loss of transformer and has the function of harmonic analysis which is convenient for analyzing the quality of on-site power network. The device can automatically check whether the wiring is correct and display the vector diagram of the three-phase current and voltage when testing the three-phase transformer. At the same time necessary correction (such as waveform correction temperature correction unrated voltage correction calibration unrated current correction) is introduced to make the test results more accurate. Product name Transformer capacity test instrument transformer capacity load tester
Modulating Capacity Transformer Special Transformer Modulating capacity transformer is one kind of distribution transformers, which has two capacities ( one is small , another one is large) and can adjust according to the load size. The changing of high voltage winding connection mode, the conversion of low voltage winding parallel series and the adjustment of every connection are finished by special no excitation modulating capacity switch. Meanwhile, when large capacity is adjusted to small capacity, no-load loss and no-load current will be reduced because the increasing of low voltage turns and the decrease of coreâ??s magnetic flux density reduce unit loss of silicon steel, thus reaches the purpose of lowing loss and energy-saving. Double voltage distribution transformer has one small and one large voltage, and can adjust according to electric grids voltage. The conversion of high voltage winding parallel series and the adjustment of every connection are finished by special no excitation modulating capacity switch.  General introduction SZ11-T load modulating capacity transformer is one kind of distribution transformers with new technology and energy-saving. It has two kinds rated capacity, one is small and another one is large, and the operation mode of these two capacity can be automatically converted which solves the problem of transformersâ?? large loss caused by relatively large changes of 10 kV distribution grids seasonable magnitude, and also solve the operational maintain problem because capacity must be adjusted by hand after the outage of no-load modulating capacity transformer power . Modulating capacity transformer not only suits rural electric grids which seasonable magnitude changes are relatively large, but also suits downtown, development zones, industrial zones and other distribution work area where circadian load changes are obvious.  Working principle Load modulating capacity transformer is adjusted by the intelligent controller externally modulating- switches, thus completing the convert process of high capacity and low capacity, more details as below: intelligent controller determines the current load size by detecting transformers voltage and current of low voltage side; determines related constraints based on the capacity setting value; if meet the setting conditions, intelligent controller will issue the corresponding control commands to load modulating capacity switch, then modulating capacity switch can finish the star ,angle change and the parallel series convert of transformer s inner high voltage winding, low voltage winding; completes the process of capacity adjustment under conditions with power.
Product introduction This product conforms to the national standard gb1094.1-2013 power transformer and GB / t6451-2015 three phase oil immersed power transformer technical parameters and requirements.� This product has adopted a series of major reforms in material, technology and structure, so that the electrical performance of the product can reach the advanced level of similar products. With the characteristics of high efficiency and low consumption, it can save a lot of power consumption and operation costs, and has remarkable social benefits. It is a new product promoted by the state. It is also one of the more popular products for users.
Product Introduction TKBB-S Transformer Ratio Tester is specially designed for three- phase transformer in power system especially for transformer of type Z winding and other transformers whose zero-load current is relatively high.Transformer turns ratio test is very important in order to find out the transformer has the right ratio corresponding on its rated voltage in primary and secondary. TKBB-S is single phase, automatically test set specially designed for turns ratio, phase shift and excitation current measurements of power, distribution and instrument transformer. The tester has wide testing range fast testing speed favorable repeatability flexible data processing convenient connection complete protection easy learning and convenient operation
Single Phase, Double Wound Transformer Capacity - BRAND - VIJAYANTA, INDIA 1. Single Phase, Double Wound Transformer Capacity : 1 KVA, 2 KVA.
GF1061PT is the first portable device (4.8 kg) which offers highly accurate voltage transformer tests. This allows to use GF1061PT not only for electrical performance checks, but also for class verification and calibration. It performs quick tests of all kinds of inductive voltage transformers (VTs or PTs) and capacitive voltage transformers (CVTs) for both protection and metering purposes. Its lightweight design makes it ideal for on-site tests and calibration tasks in power system grids. Accuracy 0.02% Power supply AC 220V±10% or AC 120V±10%, 50/60Hz or Battery Output voltage 0-100Vrms Output current 0-5Arms (20A peak-value) Output power 0-400 VA (1500 VApeak) Automatic frequency variation range 0.1-60Hz Equivalent excitation voltage â?¤5000V/50KV Accuracy â?¤0.5% Secondary winding DC resistance measurement Range 0.1-1000�© Accuracy â?¤0.05% Secondary actual load measurement Range 5VA-1000VA Accuracy â?¤0.5%�±0.1VA PT phase error measurement Accuracy ±1min (typical) / 3 min (guaranteed) Resolution 0.1min PT ratio error measurement Range 1-15000 Accuracy 0.05% LCD display 7' inch TFT touch color LCD Communication port USB port Printer Yes, Thermal printer