OPTOD Optical Dissolved Oxygen & Temperature Sensor Optical technology: The OPTOD sensor is based on luminescent optical technology and is approved by the ASTM International Standard Method D888-05. Without calibration requirements, and thanks to an ultra low power technology, the OPTOD sensor is suitable for field work as well as long and short term monitoring. With no oxygen consumption, this technology gives an accurate measure in all situations, even in very low oxygen concentrations. Digital Technology: The "smart" OPTOD sensor stores calibration and history data within the sensor. This allows you a "plug and play" system without re-calibration. Digitally optimised measurement technology * Optical luminescence technology requires minimal maintenance * Digital sensor: Modbus RS-485 * No calibration required and therefore little to no drift occurs * Robust and Watertight OPTOD Optical Dissolved Oxygen & Temperature Sensor Applications * Industrial effluent treatment * Urban waste water treatment * Surface water monitoring * Drinking water OPTOD Optical Dissolved Oxygen & Temperature Sensor Specifications * Measurement ranges: 0.00 to 20.00 mg/L * Resolution: 0,01 * Accuracy: +/- 0.1mg/L, +/- 0.1 ppm, +/- 1 % * Response time: 90% of the value in less than 60 seconds * Temperature compensation: Via CTN * Operating temperature: -10°C to +60'C * Signal interface: Modbus RS-485 (standard) and SDI-12 (option) * Sensor power-supply: 5 to 12 volts
1. Current overload or line surge shutdown 2. High temperature compressor shutdown. 3. High pressure alarm shutdown. 4. Low pressure alarm shutdown. 5. Low oxygen cocentrator alarm. Oxygen concentrator: 0.5-5L/min Purity: 95%+_3% Working system Continuous Power Supply AC230V.50Hz/AC220V.60HZ AC120V.60Hz Power: 390VA Net Weight: 16kg( Gross weight: 18.5kgs) Warranty: Long-life compressor designed for 1000 hours of maintenance-free use. Size: 33*26*54cm
Technique Parameter Oxygen flow rate .. 1L-5L Oxygen concentration .. 93% + 3% Rated voltage / Power .. AC220+V 22V ,50Hz + 1Hz Material .. Plastic Oxygen concentration .. 0.5-3L/min + 90% Flow fluctuation .. 0.7L/min Atomization amount .. + 0.2ml/min environment temperature .. 5-40 humidity range .. 80% Atmospheric pressure range .86kpa -- 106kpa Size .. L448*W245*H492 Weight .. 14.5g 1. Headset type components (optional) 2. Nasal tube assembly (optional) 3. Atomizer assembly
Technique Parameter Oxygen flow rate .. 1L-5L Oxygen concentration .. 93% + 3% Rated voltage / Power .. AC220V + 22V ,50Hz + 1Hz Material .. Plastic Oxygen concentration .. 0.5-3L/min 90% Flow fluctuation .. 0.7L/min Atomization amount .. 0.2ml/min environment temperature .. 5-40 humidity range .. 80% Atmospheric pressure range .. 86kpa -- 106kpa Size .. L448*W245*H492 Weight .. 14.5g 1. Headset type components (optional) 2. Nasal tube assembly (optional) 3. Atomizer assembly
1.Name: Sodium nitrate Chemical formula: NaNO3 Formula weght:84.99 2.Property: (1) ordinary sodium nitrate: white little crystals or light yellow (2) dry powder sodium nitrate: non-caking, showing loose status. Density:2.257. It is liable to deliquesce, dissolved in water, soluble in liquid ammonia, slightly soluble in ethanol and glycerin, Melting Point:308. While being heated up to about 380 it will decompose and release oxygen and turn into sodium nitrite,as the heating goes on, it will decompose into oxygen, nitrogen and nitrogen oxide. It has strong oxidability and can cause combustion explosion if being mixed with organic substance, sulfur, sodium nitrate etc. 3. Usage:Â it has been wildly used in the glass industry, dye, dynamite, metallurgy, machinery, ceramic etc. 4. Specification: (Technical Standards:GB/T4553-2002) Item Unit High G. First G. Qualified G. Dry powder G. Assay % 99.7 99.3 98.5 99.3 Sodium nitrite % 0.01 0.02 0.15 0.02 Chlorides % 0.25 0.30 -- 0.25 Water insolubles % 0.03 0.06 -- 0.03 Moisture % 1.0 1.5 2.00 0.2 Carbonates % 0.05 0.10 -- 0.1 Iron % 0.005 -- -- 0.005 Loose degree -- -- -- 95 5.Package: net 25kg/50kg net each in plasic woven inner plasic bag,or 500kg net each in flexible container.
Commodity: Calcium chloride Molecular formula CaCl2 H.S code 28272000 Product feature Calcium chloride is an inorganic salt, which exists as solid or liquid. Solid calcium chloride is a white, crystal substance in the form of flake, granule, pellet or powder. With different crystallized water contents, it can be dihydrate or anhydrous. Liquid calcium chloride is a colorless, clear solution. As calcium chloride has such properties as quick dissolving, exothermic ability, attracting moisture from the air and surroundings, dissolving at very low temperature, Specifications: Analysis Item Standard Calcium chloride (CaCl2) 74%min,77% min,94%min Total Chlorinated Alkali: (NaCl) 5.0%max Magnesium Chloride(MgCl2) 0.5%max Insoluble matter in water 0.25%max Calcium Sulfate (CaSO4): 0.2%max Ferric Oxide (Fe2O3) 0.025%max Heavy Metal as Cu., Pb., Cd., Cr., Hg., As 0.005%max Application Mainly used in drying, melting snow for airport express and street, concrete desiccant and concreting fast, removing dust and oil industry. Exporting Packing :Plastic woven bag with PE ,25kg/50kg/1000kgs net weight or 25kg x 40 bags into one big bag or 40 bags on a pallet with shrink-wrapped Means of transportation :in containers or by bulk vessel with large quantity
1,Name: Sodium nitrite Molecular formula: NaNO2 Formula weght:69.00 2Property: (1) ordinary sodium nitrite: white little crystals or light yellow  (2) dry powder sodium nitrate: white crystal,non-caking, showing loose status. Density:2.168. No odor, slightly salty. It is liable to deliquesce, dissolved in water,soluble in liquid ammonia,slightly soluble in ethanol and glycerin,Melting Point:271. Decomposition temperature is 320. It has oxidability and also has reducibility. It will slowly be oxidized into sodium nitrate in atmosphere, it can form nitrogen compound with nitrilo at low temperatures. 3Usage:It has been widely used in making nitro-compound and azo dye, mordant of textile dyeing, bleaching agent, metal heat finishing agent, cement early strength agent, and deicing agent etc. Note: The product should be stored in a cool, dry place to prevent it from moisture, heat and sunlight. This product can not be mixed with strong reductant, inflammable and explosive materials, food, feed and additives. â?¢ This product is toxic and should be properly kept and can not be eaten. 4 Specification: (Technical Standards:GB2367-2006) Item Unit Molten salt G High G First G Qualified G Dry powder G Assay % 99.3 99.0 98.5 98.0 98.5 Sodium nitrate % 0.6 0.80 1.00 1.90 0.80 Chlorides % 0.03 0.10 0.17 -- 0.1 Water insolubles % 0.02 0.05 0.06 0.10 0.06 Moisture % 1.0 1.4 2.0 2.5 0.2 Loose degree -- -- -- -- 95 5,Package: net 50kg net each in plasic woven inner plasic bag, or according to customers requirement.
Product Brief Introduction: with the largest consumption for construction and building materials. It is mainly used as enamel fluxing agent, glass opalizing agent, acid-proof clay, acid-proof concrete coagulator and wood preservative. It can also be used for insecticide. Product Hazard or Harmful Ingredients:It does not combust or explode but has corrosivity and certain toxicity. Product Physical Properties:The product is white powder crystals and basically neutral. It is difficult to dissolve in water and acid and the density is 2.37g/cm3. Product Chemical Properties:It is stable under normal temperature. It does not combust nor explode when it is heated or contacts with redox materials. Spillage Treatment Method:Simple cleaning and burying Protection Measures for Product Transport & Storage:To prevent from caking and going bad, it should be kept indoor or be covered with protection materials like canvas and free from the blazing sun. Packing :Knitted bags lined polyethylene plastic bags double packaging, Weighing 25Kg/50KG/1000Kg/1200kg. Other Information: Anti-caking agent can be added at the request of customers. Technical Specifications Analysis items Standard Na2SiF6 99% min Loss of weight on drying at 105â?? 0.3% max Free acid (as HCl) 0.1% max Chloride (as Cl) 0.1% max Sulphate (SO4) 0.3% max Iron(Fe) 0.02% max Water-insoluble matter 0.5% max Particle size distribution Passing through 40 mesh sieve 98% min Passing through 60 mesh sieve 90% min Passing through 325 mesh sieve 25% max
Commodity: Sodium Lauryl Ether Sulfate Synonyms: Sodium Laury Ethyle Sulfate 70% aqueous solution; Sodium Alkyl Ethoxy Sulfate 70% aqueous solution; Sodium C10-16 Alkyl Ethoxy Sulphate (Predominantly C12-C14) 70% aqueous solution; SLES 70% aqueous solution Molecular formula: CH3-(CH2) n-(O-CH2-CH2) p -OSO3Na, where n=9~15, p=2 Mean molecular weight: 388 Description: It has excellent detergency, emulsification ,and foamability, it is easy to dissolve in water. As well as favorable hard-water resistant and high-biodegradation. Specifications: ITEM SLES - 70 SLES - 28 Appearance Transparent or white viscous paste light yellow transparent liquid Odor No strange odors No strange odors Active Matter% 70�±2 28�±2 PH value 7.0-9.5 7.0-9.5 Unsulfated matter% Max. 2.0 Max. 1.0 Sodium sulfate % Max. 1.0 Max. 0.5 Microbiological(CFU/g) Max. 100 Max. 100 Dioxane(ppm) Max. 50 Max. 50 Heavy metal(ppm) Max. 10 Max. 10 Peroxide% Max. 0.1 Max. 0.1 Color Max. 10 Max. 10 Usage: 1. Used to prepare the shampoo, bath foam, soap,hand cleaner , liquid detergent and detergent. 2. Used in hard surface cleaner, such as the glass cleaner, car cleaner, they always used with the K12ã??LAS-Naã??6501. 3.Used in the textile, paper making, leather, machinery, petroleum. Industry. Packing: plastic drum, per 160kg/170kg/200kg/220kg net weight Loading weight in 1x20fcl: 18.24mt for 160kg drum 19.38mt for 170kg drum 17.6mt for 220kg drum Storage: sealed and stored at the room temperature, the shelf life is two years.
Commodity:Sodium persulfate Molecular Formula : Na2S2O8 Molecular weight : 238.13 Description Sodium persulfate is a white,crystalline,odourless salt.It is used as initiator for the Polymerization of monomers and as a strong oxidizing agent in many applications.It has the particular advantage of being almost non - hygroscopic,of having a particularly good storage stability as a result of its extremely high purity and of being easy and safe to handle. Transportation Road/Rail transport : GGVS,GGVE,ADR,RID/CLASS 5.1 Sea transport : GGV Sea/IMDG code : CLASS 5.1 Page 5185,UN no.1505 Water hazards class 1(slight water hazard) All information is given in good faith,but without warranty,since the conditions of use are outside our control. Verification by the user is recommended.Freedom from patent restriction cannot be assumed. Package (1) In 25kgs net multiple paper bags with one PE bag inner (2) In 25kgs net PE bags (3) In 25kgs net woven bags with two PE bags inner (4) In 1000kgs net big woven bags with one PE bag inner The above package is also with a pallet 1000kgs each. Storage NPS(SPS) is not combustible but assists combustion materials due to release of oxygen.Provided it is stored under appropriate condition.It must be stored dry in closed containers and protected from direct sunlight,heat and humidity.Impurities such as dirt,rust or traces of metal and reductants may cause catalytic decomposition.The product as supplied or in solution needs to be handled with appropriate care.The eye,skin and clothes must be protected when working with NPS(SPS) as damp powder or aqueous solution has a bleaching and slightly corroding effect. Application Polymerization : Initiator for the emulsion or solution Polymerization of acrylic monomers,vinyl acetate,vinyl chloride etc.and for the emulsion co-polymerization of styrene,acrylonitrile,butadiene etc. Metal treatment : Treatment of metal surfaces(e.g. in the manufacture of semiconductors; cleaning and etching of printed circuits),activation of copper and aluminium surfaces. Cosmetics : Essential component of bleaching formulations. Paper : modification of starch,repulping of wet - strength paper. Textile : Desizing agent and bleach activator - particularly for cold bleaching.(i.e.bleaching of Jeans). Others : - Chemical synthesis - Water treatment(decontamination) - Waste gas treatment,oxidative degradation of harmful substances(e.g.Hg) - Disinfectant ITEMS SPECIFICATIONS Appearance white crystalline salt Assay 99.0% w/w min Active oxygen 6.65% w/w min Chloride and chlorate(as CL) 0.005% w/w max Ammonia (NH4) 0.05% w/w max Manganese(Mn) 0.0001% w/w max Iron(Fe) 0.001% w/w max Heavy metals(as Pb) 0.001% w/w max Moisture 0.05% w/w max Decomposition of the product as supplied at above 65C Recommended storage temperature Normal Temperature Storage stability as from date of delivery 12 months
2-Naphthol Basic information Chemical Properties Application Preparation Product Name: 2-Naphthol Synonyms: c.i.37500;c.i.azoiccouplingcomponent1;c.i.developer5;Developer A;Developer AMS;Developer BN;developera;developerams CAS: 135-19-3 MF: C10H8O MW: 144.17 EINECS: 205-182-7 Product Categories: Fluorescent;Naphthalene;pigments;alcohol;MICROCIDIN;Color Former & Related Compounds;Developer;Functional Materials;Intermediates;Aromatic Compounds;Alphabetical;Bioactive Small Molecules;Biochemicals and Reagents;Building Blocks;C9 to C20+;Cell Biology;Chemical Synthesis;Fluorescent Indicators and Probes;Fluorescent Probes;Labels;N;Organic Building Blocks;Oxygen Compounds;Particles and Stains;pH Sensitive Probes and Indicators;Phenols;Dyestuff Intermediates;Aromatics Mol File: 135-19-3.mol 2-Naphthol Chemical Properties Melting point 120-122 C(lit.) Boiling point 285-286 C(lit.) density 1,28 g/cm3 vapor density 4.97 (vs air) vapor pressure 10 mm Hg ( 145.5 C) refractive index 1.5762 (estimate) Fp 153 C storage temp. Refrigerator solubility methanol: soluble1g/10 mL, clear, colorless to light yellow pka 9.51(at 25C) form Powder, Crystals or Granules color White PH Range Non& uorescence (8.5) to blue & uorescence (9.5) Water Solubility 1 g/L (20 C) �»max 226nm, 265nm, 275nm, 286nm, 320nm, 331nm Merck 14,6384 BRN 742134 Stability: Stable. Combustible. Dust may form explosive mixture with air. Incompatible with strong oxidizing agents, phenol. Major Application Display device, semiconductors, photoimaging materials, inks, toner, chalk, security paper, molding materials, tin plating method, rubber, adhesive, leather, detergent, hair dyes, antimitotic drug, anticancer agent, antiinflammatory agent, treatment of acne vulgaris (pimples) and other dermal ailments (rashes, scratches, blemishes, hair loss), disorders InChIKey JWAZRIHNYRIHIV-UHFFFAOYSA-N CAS DataBase Reference 135-19-3(CAS DataBase Reference) NIST Chemistry Reference 2-Naphthalenol(135-19-3) EPA Substance Registry System 2-Naphthalenol (135-19-3) Safety Information Hazard Codes Xn,N Risk Statements 20/22-50 Safety Statements 24/25-61 RIDADR UN 3077 9/PG 3 WGK Germany 2 RTECS QL2975000 F 8 Autoignition Temperature 430 C TSCA Yes HazardClass 9 PackingGroup III HS Code 29071590 Hazardous Substances Data 135-19-3(Hazardous Substances Data) Toxicity LD50 orally in Rabbit: 1960 mg/kg LD50 dermal Rabbit > 10000 mg/kg 2-Naphthol Usage And Synthesis 2-Naphthol Preparation Products And Raw materials
Do1200 and do1200tc dissolved oxygen sensors Item no.: do1200/h, do1200/t, do1200tc/h, do1200tc/t, 971598, 971598tc Reliable galvanic sensing technology Compact 12mm design For portable, laboratory or on-line use Optional integral atc element Easy to use pre-membraned replacement caps The do1200 and do1200tc feature dependable galvanic technology. No warm up period is required. Sensors are supplied with fast responding hdpe membrane caps for portable or lab use. Optional ptfe membrane caps are available for on-line or heavy uv exposure applications. Fill solution is replaceable when required. The do1200 is supplied without internal temperature compensation. The do1200tc can be supplied with a variety of user defined atc elements. Standard cable length is 2.5 feet with a tinned lead termination. Longer cable lengths and connectors are available for an additional charge. For on-line use, our fc75p 3/4 inch in-line fitting may be ordered to provide for mounting into 3/4 inch fnpt threaded tees. Do1200 laboratory dissolved oxygen sensor specifications Range: 0-20 mg/l Body material: epoxy and noryl Max temperature: 50 degrees c Saturation output: Hdpe = 47mv +/- 9mv, Ptfe = 33mv+/-9mv Pressure: 0-100 psig (7.5 bar) Calibration: single point in air Response time: after equilibration, hdpe 1 minute for 2mv, ptfe 2 minutes for 2mv
WQ401 Dissolved Oxygen Sensor Description WQ401 Dissolved Oxygen Sensor is a rugged and reliable water oxygen measuring device. The WQ401's sensor is attached to 25 ft of marine grade cable, with lengths up to 500 ft available upon request. The sensor's output is 4-20 mA with a three wire configuration. The sensor's electronics are completely encapsulated in marine grade epoxy within a stainless steel housing. The unit uses a removable shield and dissolved oxygen element for easy maintenance. WQ401 Dissolved Oxygen Sensor Features * Measure dissolved oxygen in situ * Fully encapsulated electronics * 4-20 mA output * Marine grade cable with strain relief * Stainless steel housing * Replaceable dissolved oxygen element WQ401 Dissolved Oxygen Sensor Applications Ideal for stream and lake monitoring, aquaculture studies, baseline analyses, mitigation monitoring, and other environmental applications. WQ401 Dissolved Oxygen Sensor Specifications * Output: 4-20 mA * Range: 0 to 100% saturation, 0 to 8 ppm, temperature compensated to 77'F (25'C) * Accuracy: ±0.5% full scale * Maximum Pressure: 40 psi * Operating Voltage: 10 to 36 VDC * Current Draw: 15.5 mA plus sensor output * Warm-up Time: 10 seconds minimum * Operating Temperature: -40 to +131'F (-40 to +55'C)
Do1200 and do1200tc dissolved oxygen sensors Item no.: do1200/h, do1200/t, do1200tc/h, do1200tc/t, 971598, 971598tc Do1200 dissolved oxygen sensor features * reliable galvanic sensing technology * compact 12mm design * for portable, laboratory or on-line use * optional integral atc element * easy to use pre-membraned replacement caps Do1200 dissolved oxygen sensor description The do1200 and do1200tc feature dependable galvanic technology. No warm up period is required. Sensors are supplied with fast responding hdpe membrane caps for portable or lab use. Optional ptfe membrane caps are available for on-line or heavy uv exposure applications. Fill solution is replaceable when required. The do1200 is supplied without internal temperature compensation. The do1200tc can be supplied with a variety of user defined atc elements. Standard cable length is 2.5 feet with a tinned lead termination. Longer cable lengths and connectors are available for an additional charge. For on-line use, our fc75p 3/4 inch in-line fitting may be ordered to provide for mounting into 3/4 inch fnpt threaded tees. Do1200 dissolved oxygen sensor specifications * range: 0-20 mg/l * body material: epoxy and noryl * max temperature: 50 degrees c * saturation output: hdpe = 47mv +/- 9mv, ptfe = 33mv+/-9mv * pressure: 0-100 psig (7.5 bar) * calibration: single point in air * response time: after equilibration, hdpe 1 minute for 2mv, ptfe 2 minutes for 2mv
Do sensor dissolved oxygen sensor water quality control sensor kds-25b Model number: kds-25b Description The gs yuasa dissolved oxygen sensor kds-25b is a unique Galvanic cell type sensor which was developed for water quality Control. Its most notable features are long life expectancy and it Is not influenced by co2. Features: * long life * virtually no influence from co2 * no external power supply required for sensor Operation * no warmup time is required Applications: * water quality control
Magnesia Bricks Description Magnesia Bricks are alkaline refractory materials. These products have over 90% magnesium oxide content and adopt periclase as the principal crystalline phase. Magnesia Bricks can be divided into two categories of Burnt Magnesia Bricks and Chemical Bonded Magnesite Brick. They have excellent performance of superior high temperature mechanical strength and volume stability. Magnesia Bricks can service in the high temperature of 1750.. They are ideal products for glass furnace application. Magnesia Bricks Features: It is a kind of alkaline refractory product with periclase as main phase magnesite-alumina spinel clinker as basic material. the product has such characteristics as good temperature vibration, good strength and volume stability in high temperature. Magnesia Bricks Application Basic open-hearth furnace for steelmaking Electric furnace bottom and wall Permanent lining of oxygen converter Non-ferrous metal metallurgy furnace Hyperthermia tunnel kiln Lining of rotary cement kiln Heating furnace bottom and wall Regenerative chamber of glass furnace Magnesia Bricks Properties High Refractoriness Good alkaline slag erosion resistance High apparent initial softening temperature Good thermal conductivity High thermal expansion Magnesia Bricks Manufacturing Process Burnt Magnesia Bricks are manufactured with magnesite clinker as the raw material and fired in the high temperature of 1550~1600 after smashing, burdening, mulling and molding. High-purity products can be fired in the temperature that over 1750. Chemical bonded magnesite brick is produced with certain chemical bonding through mixing, molding and drying.
Wq-fdo optical dissolved oxygen sensor description The wq-fdo optical dissolved oxygen transmitter is an instrument designed for measuring dissolved oxygen concentrations in liquids. The wq-fdo optical dissolved oxygen transmitters were developed to meet different requirements ranging from surface water monitoring programs to harsh waste water applications. The optical dissolved oxygen transmitter has been specifically designed to meet the demanding requirements of the environmental monitoring and scientific research sectors, providing long term, accurate and reliable dissolved oxygen measurement. The wq-fdo optical dissolved oxygen transmitter has extremely low power requirements and a 4-20 ma output making it ideal for incorporation into remote environmental monitoring installations. Wq-fdo optical dissolved oxygen sensor features * extremely fast and precise optical do sensor - outstanding for field and lab applications * proven green light technology for long operation life of sensor * beveled membrane repells interference that can be caused by air bubbles * universal protective armoring available * low power consumption and low maintenance * simple to integrate and operate * one year sensor life Wq-fdo optical dissolved oxygen sensor applications Long and short term monitoring for streams, rivers, lakes, aquaculture, thermocline profiling, industrial outfalls, wastewater, scientific research, homeland security, the food and wine industry, and more. Wq-fdo optical dissolved oxygen sensor specifications * dissolved oxygen accuracy: â± 0.5 % of value * dissolved oxygen repeatability: 0.01 ppmâ?? * temperatureâ?? accuracy: â±0.2'f (â±0.1'c)â?? * temperatureâ?? resolution:â?? 0.02'f (0.01'c)â?? * temperatureâ?? range: 32 to 122'f (0 to 50'câ?? * max pressure: 35 psi (25m/82ft water depth)â?? * operating voltage: 10-30 vdcâ?? * warm up time: 6 sec. Min, 8 recommendedâ??
Y504-a dissolved oxygen sensor description The sensor is based on optical fluorescence lifetime quenching technique. Its technical procedure meets astm d888-09 standard for optical sensing of dissolved oxygen. This online sensor is developed to integrate with yosemite wireless monitoring system. Its rugged design and large measurement range make it ideal for sampling, flow cell, ground water and waste water measurements. Y504-a dissolved oxygen sensor applications Fish farmer, waste water plant, river, stream, and ocean monitoring Y504-a dissolved oxygen sensor feature , 0-20mg/l or 0-200% saturation , 0~50'c; ip68 rating , membraneless, no electrodes design , no oxygen consumption , flow independent , automatic temperature compensation , no h2s interference , low drift, fast response, and more accurate , low maintenance, low operating cost , easy sensor cap replacement , rs-485; modbus protocol compatible Y504-a dissolved oxygen sensor technical specifications , range, : 0-20mg/l or 0-200% saturation, , response time: 10 sec , housing ip rating: ip68, , accuracy: 1%, , drift:
Rdo-200 fluorescence dissolved oxygen sensor application Widely used in online dissolved oxygen monitoring for power plant, chemical, industrial wastewater, pharmaceutical, biochemical and water treatment industry. Rdo-200 fluorescence dissolved oxygen sensor feature * 0-20mg/l or 0-200% saturation * 0 ~ 50'c; ip68 protection rating * no film, no electrolyte, not polarization * no consumption of oxygen, the flow rate is not affected * built-in temperature sensor, automatic temperature compensation * chemical interference from sulfide * in drift, fast response, more accurate measurements * maintenance-free longer applicable period, lower cost * fluorescent cap replacement is simple * supports rs-485, modbus protocol Technical instructions Do range: -20mg/l 0-20 mg/l or 0-200% saturation Reaction time: 10 sec Degree of protection: ip68 Do accuracy±1% Sensor drift:
Submersible galvanic dissolved oxygen sensors Item no.: do6400/h, do6400/t, do6400tc/h, do6400tc/t, do6441/t, do6442/t, Do7400/h, do7400/t, do7400tc/h, do7400tc/t, do7441/t, do7442/t Large solution capacity for long term deployment Models with and without temperature sensor Easy installation and maintenance Mv or 4-20ma output models available The do6400 & 7400 series dissolved oxygen sensors feature a large capacity electrolyte holder, positive fit, easy to replace membrane and dependable galvanic cell technology for long term deployment. The body design ensures a good grip when wet. Ideal for aquaculture and wastewater monitoring applications, these sensors require minimal maintenance. Ptfe or high-density polyethylene (hdpe) membranes are available. 2 replacement membranes, installation tool and electrolyte are included. Additonal maintennace parts are in convenient kits (see ordering information). Sensors with mv output as well as built-in 4-20ma output in 0-100% and 0-200% saturation range are available. Dissolved oxygen sensors specifications O2 measuring range: Do6400, do6400tc (0.5-20ppm), do6441(0-100%), do6442(0-200%) Do7400, do7400tc (0.03-20ppm), do7441(0-100%), do7442(0-200%) Body: material noryl Cathode: silver Anode: zinc (do6400 series), lead (do7400 series) Maximum temperature: 50 degrees c Power requirement: 12-36v dc (for models do6441, do6442, do7441 and do7442 only )