Do1200 and do1200tc dissolved oxygen sensors
Item no.: do1200/h, do1200/t, do1200tc/h, do1200tc/t, 971598, 971598tc
Reliable galvanic sensing technology
Compact 12mm design
For portable, laboratory or on-line use
Optional integral atc element
Easy to use pre-membraned replacement caps
The do1200 and do1200tc feature dependable galvanic technology. No warm up period is required. Sensors are supplied with fast responding hdpe membrane caps for portable or lab use. Optional ptfe membrane caps are available for on-line or heavy uv exposure applications. Fill solution is replaceable when required.
The do1200 is supplied without internal temperature compensation. The do1200tc can be supplied with a variety of user defined atc elements. Standard cable length is 2.5 feet with a tinned lead termination. Longer cable lengths and connectors are available for an additional charge. For on-line use, our fc75p 3/4 inch in-line fitting may be ordered to provide for mounting into 3/4 inch fnpt threaded tees.
Do1200 laboratory dissolved oxygen sensor specifications
Range: 0-20 mg/l
Body material: epoxy and noryl
Max temperature: 50 degrees c
Saturation output:
Hdpe = 47mv +/- 9mv,
Ptfe = 33mv+/-9mv
Pressure: 0-100 psig (7.5 bar)
Calibration: single point in air
Response time: after equilibration, hdpe 1 minute for 2mv, ptfe 2 minutes for 2mv
Do1200 and do1200tc dissolved oxygen sensors Item no.: do1200/h, do1200/t, do1200tc/h, do1200tc/t, 971598, 971598tc Do1200 dissolved oxygen sensor features * reliable galvanic sensing technology * compact 12mm design * for portable, laboratory or on-line use * optional integral atc element * easy to use pre-membraned replacement caps Do1200 dissolved oxygen sensor description The do1200 and do1200tc feature dependable galvanic technology. No warm up period is required. Sensors are supplied with fast responding hdpe membrane caps for portable or lab use. Optional ptfe membrane caps are available for on-line or heavy uv exposure applications. Fill solution is replaceable when required. The do1200 is supplied without internal temperature compensation. The do1200tc can be supplied with a variety of user defined atc elements. Standard cable length is 2.5 feet with a tinned lead termination. Longer cable lengths and connectors are available for an additional charge. For on-line use, our fc75p 3/4 inch in-line fitting may be ordered to provide for mounting into 3/4 inch fnpt threaded tees. Do1200 dissolved oxygen sensor specifications * range: 0-20 mg/l * body material: epoxy and noryl * max temperature: 50 degrees c * saturation output: hdpe = 47mv +/- 9mv, ptfe = 33mv+/-9mv * pressure: 0-100 psig (7.5 bar) * calibration: single point in air * response time: after equilibration, hdpe 1 minute for 2mv, ptfe 2 minutes for 2mv
LED light.
For the Mosquito killer Led Bulb Light, is a 900 lumen bulb that doubles as an insect killer. The light features a blue UV LED which attracts insects into a Mosquito Killer grid.And the Mosquito Killer grid uses only 1W of electricity, while the light itself uses a meager 9W – and both can be used independently.They are used at home and outdoor. A brush is provided to clean off insects once the bulb switched-off.Compare to other traditional mosquito killer, this bulb has no chemicals, no sprays and hence no fumes to our life. • 2nd generation 2-in-1 LED LIGHT Bulb Plus LED Mosquito Killer Bulb • Wattage: 10W • Blue UV light • Lumen: 900-1000lm • Color Temperature (CCT): 6500K • Input Voltage: AC 90-130V & 220v-240V • With CE and ROHS Operation: Step1: Switch it on,both lighting +killing are on. Step2: Switch on again,light off,only killing on. Step3: Switch on again,killing off,only light on. Step4: Switch off, both off.
Powerï¼? 900W LED Qtyï¼? 72pcs 5W LED & 6pcs 90W COB Voltage ï¼? AC85-265V Work frequencyï¼? 50/60Hz Lumen ï¼? >15400Lm Dimmensionï¼? 660X385X118mm N.W ï¼? 11.4kg Coverage ï¼? 1.0Ã?1.2 m Warranty ï¼? 50000 hours
Power 900W LED Qty 72pcs 5W LED & 6pcs 90W COB Voltage AC85-265V Work frequency 50/60Hz Lumen >15400Lm Dimmension 660X385X118mm N.W 11.4kg Coverage 1.0 1.2 m Warranty 50000 hours
Power 1200W LED Qty 96pcs 5W LED & 8pcs 90W COB Voltage AC85-265V Work frequency 50/60Hz Lumen 21050Lm Dimmension 848X385 X118mm N.W 14.8kg Coverage 1.5 X1.0 m Warranty 50000 hours
Supplier: Wireless charger, batteries power bank, dust sensor, optical disc drive, tof, lidar, ar glass
Our most advanced intelligent spot detectors, multi-criteria/multi-sensor devices use multiple sensors to detect various conditions in an environment sensing a wider range of fires with greater accuracy. Features & Benefits: Multi-Criteria/Multi-Sensor smoke detection Unique ability to detect major elements of a fire Highest nuisance alarm immunity Advanced algorithms interpret and respond to multiple inputs
Do sensor dissolved oxygen sensor water quality control sensor kds-25b Model number: kds-25b Description The gs yuasa dissolved oxygen sensor kds-25b is a unique Galvanic cell type sensor which was developed for water quality Control. Its most notable features are long life expectancy and it Is not influenced by co2. Features: * long life * virtually no influence from co2 * no external power supply required for sensor Operation * no warmup time is required Applications: * water quality control