Do1200 and do1200tc dissolved oxygen sensors
Item no.: do1200/h, do1200/t, do1200tc/h, do1200tc/t, 971598, 971598tc
Do1200 dissolved oxygen sensor features
* reliable galvanic sensing technology
* compact 12mm design
* for portable, laboratory or on-line use
* optional integral atc element
* easy to use pre-membraned replacement caps
Do1200 dissolved oxygen sensor description
The do1200 and do1200tc feature dependable galvanic technology. No warm up period is required. Sensors are supplied with fast responding hdpe membrane caps for portable or lab use. Optional ptfe membrane caps are available for on-line or heavy uv exposure applications. Fill solution is replaceable when required.
The do1200 is supplied without internal temperature compensation. The do1200tc can be supplied with a variety of user defined atc elements. Standard cable length is 2.5 feet with a tinned lead termination. Longer cable lengths and connectors are available for an additional charge. For on-line use, our fc75p 3/4 inch in-line fitting may be ordered to provide for mounting into 3/4 inch fnpt threaded tees.
Do1200 dissolved oxygen sensor specifications
* range: 0-20 mg/l
* body material: epoxy and noryl
* max temperature: 50 degrees c
* saturation output: hdpe = 47mv +/- 9mv, ptfe = 33mv+/-9mv
* pressure: 0-100 psig (7.5 bar)
* calibration: single point in air
* response time: after equilibration, hdpe 1 minute for 2mv, ptfe 2 minutes for 2mv
Do1200 and do1200tc dissolved oxygen sensors Item no.: do1200/h, do1200/t, do1200tc/h, do1200tc/t, 971598, 971598tc Reliable galvanic sensing technology Compact 12mm design For portable, laboratory or on-line use Optional integral atc element Easy to use pre-membraned replacement caps The do1200 and do1200tc feature dependable galvanic technology. No warm up period is required. Sensors are supplied with fast responding hdpe membrane caps for portable or lab use. Optional ptfe membrane caps are available for on-line or heavy uv exposure applications. Fill solution is replaceable when required. The do1200 is supplied without internal temperature compensation. The do1200tc can be supplied with a variety of user defined atc elements. Standard cable length is 2.5 feet with a tinned lead termination. Longer cable lengths and connectors are available for an additional charge. For on-line use, our fc75p 3/4 inch in-line fitting may be ordered to provide for mounting into 3/4 inch fnpt threaded tees. Do1200 laboratory dissolved oxygen sensor specifications Range: 0-20 mg/l Body material: epoxy and noryl Max temperature: 50 degrees c Saturation output: Hdpe = 47mv +/- 9mv, Ptfe = 33mv+/-9mv Pressure: 0-100 psig (7.5 bar) Calibration: single point in air Response time: after equilibration, hdpe 1 minute for 2mv, ptfe 2 minutes for 2mv
Supplier: Led bulb, tube light, panel light, decoration light, wall light, steel wires, steel plate, stainless steel plate, twisted wire rods, galvanized wires, wire mesh, site fencing, mosquito mesh, thread rods, rebar, twisted rods, t bar, nuts and bolts, hardware, pvc pipes, upvc pipes, api pipes, melamine, mdf board, plywood, film faced, shuttering, packing, core veneer, face veneer, hdf molded door skin, door filler, tubular particle boards, pvc boards, wpc boards, doors, block board, hard board, gypsum board, canopy, carpet, flooring wooden, bamboo, laminated engineering, tiles, granite tiles, granite blocks, black galaxy, wash basin, water closets, washbasins, ss sinks, faucets, furniture, pvc edge bending, crew, locks, pvc seals, silicone cartridges, shower enclosures, shower door hinges, handles, knobs, brackets, slides, nails, solar panels, flexible solar panels, solar power station, battery, inverters, rechargeable fans, lights, spring, 3ply disposable face mask, oxygen concentrator ,
Services: Buying office, oem, components sourcing, value added services
Buyer: In shell pecan nut, macadamia nut
For the Mosquito killer Led Bulb Light, is a 900 lumen bulb that doubles as an insect killer. The light features a blue UV LED which attracts insects into a Mosquito Killer grid.And the Mosquito Killer grid uses only 1W of electricity, while the light itself uses a meager 9W – and both can be used independently.They are used at home and outdoor. A brush is provided to clean off insects once the bulb switched-off.Compare to other traditional mosquito killer, this bulb has no chemicals, no sprays and hence no fumes to our life. 2nd generation 2-in-1 LED LIGHT Bulb Plus LED Mosquito Killer Bulb Wattage: 10W Blue UV light Lumen: 900-1000lm Color Temperature (CCT): 6500K Input Voltage: AC 90-130V & 220v-240V With CE and ROHS Operation: Step1: Switch it on,both lighting +killing are on. Step2: Switch on again,light off,only killing on. Step3: Switch on again,killing off,only light on. Step4: Switch off, both off.
Supplier: Wireless charger, batteries power bank, dust sensor, optical disc drive, tof, lidar, ar glass
Do sensor dissolved oxygen sensor water quality control sensor kds-25b Model number: kds-25b Description The gs yuasa dissolved oxygen sensor kds-25b is a unique Galvanic cell type sensor which was developed for water quality Control. Its most notable features are long life expectancy and it Is not influenced by co2. Features: * long life * virtually no influence from co2 * no external power supply required for sensor Operation * no warmup time is required Applications: * water quality control