Do1200 and do1200tc dissolved oxygen sensors
Item no.: do1200/h, do1200/t, do1200tc/h, do1200tc/t, 971598, 971598tc
Do1200 dissolved oxygen sensor features
* reliable galvanic sensing technology
* compact 12mm design
* for portable, laboratory or on-line use
* optional integral atc element
* easy to use pre-membraned replacement caps
Do1200 dissolved oxygen sensor description
The do1200 and do1200tc feature dependable galvanic technology. No warm up period is required. Sensors are supplied with fast responding hdpe membrane caps for portable or lab use. Optional ptfe membrane caps are available for on-line or heavy uv exposure applications. Fill solution is replaceable when required.
The do1200 is supplied without internal temperature compensation. The do1200tc can be supplied with a variety of user defined atc elements. Standard cable length is 2.5 feet with a tinned lead termination. Longer cable lengths and connectors are available for an additional charge. For on-line use, our fc75p 3/4 inch in-line fitting may be ordered to provide for mounting into 3/4 inch fnpt threaded tees.
Do1200 dissolved oxygen sensor specifications
* range: 0-20 mg/l
* body material: epoxy and noryl
* max temperature: 50 degrees c
* saturation output: hdpe = 47mv +/- 9mv, ptfe = 33mv+/-9mv
* pressure: 0-100 psig (7.5 bar)
* calibration: single point in air
* response time: after equilibration, hdpe 1 minute for 2mv, ptfe 2 minutes for 2mv
Do1200 and do1200tc dissolved oxygen sensors Item no.: do1200/h, do1200/t, do1200tc/h, do1200tc/t, 971598, 971598tc Reliable galvanic sensing technology Compact 12mm design For portable, laboratory or on-line use Optional integral atc element Easy to use pre-membraned replacement caps The do1200 and do1200tc feature dependable galvanic technology. No warm up period is required. Sensors are supplied with fast responding hdpe membrane caps for portable or lab use. Optional ptfe membrane caps are available for on-line or heavy uv exposure applications. Fill solution is replaceable when required. The do1200 is supplied without internal temperature compensation. The do1200tc can be supplied with a variety of user defined atc elements. Standard cable length is 2.5 feet with a tinned lead termination. Longer cable lengths and connectors are available for an additional charge. For on-line use, our fc75p 3/4 inch in-line fitting may be ordered to provide for mounting into 3/4 inch fnpt threaded tees. Do1200 laboratory dissolved oxygen sensor specifications Range: 0-20 mg/l Body material: epoxy and noryl Max temperature: 50 degrees c Saturation output: Hdpe = 47mv +/- 9mv, Ptfe = 33mv+/-9mv Pressure: 0-100 psig (7.5 bar) Calibration: single point in air Response time: after equilibration, hdpe 1 minute for 2mv, ptfe 2 minutes for 2mv
LED light.
For the Mosquito killer Led Bulb Light, is a 900 lumen bulb that doubles as an insect killer. The light features a blue UV LED which attracts insects into a Mosquito Killer grid.And the Mosquito Killer grid uses only 1W of electricity, while the light itself uses a meager 9W – and both can be used independently.They are used at home and outdoor. A brush is provided to clean off insects once the bulb switched-off.Compare to other traditional mosquito killer, this bulb has no chemicals, no sprays and hence no fumes to our life. • 2nd generation 2-in-1 LED LIGHT Bulb Plus LED Mosquito Killer Bulb • Wattage: 10W • Blue UV light • Lumen: 900-1000lm • Color Temperature (CCT): 6500K • Input Voltage: AC 90-130V & 220v-240V • With CE and ROHS Operation: Step1: Switch it on,both lighting +killing are on. Step2: Switch on again,light off,only killing on. Step3: Switch on again,killing off,only light on. Step4: Switch off, both off.
Powerï¼? 900W LED Qtyï¼? 72pcs 5W LED & 6pcs 90W COB Voltage ï¼? AC85-265V Work frequencyï¼? 50/60Hz Lumen ï¼? >15400Lm Dimmensionï¼? 660X385X118mm N.W ï¼? 11.4kg Coverage ï¼? 1.0Ã?1.2 m Warranty ï¼? 50000 hours
Power 900W LED Qty 72pcs 5W LED & 6pcs 90W COB Voltage AC85-265V Work frequency 50/60Hz Lumen >15400Lm Dimmension 660X385X118mm N.W 11.4kg Coverage 1.0 1.2 m Warranty 50000 hours
Power 1200W LED Qty 96pcs 5W LED & 8pcs 90W COB Voltage AC85-265V Work frequency 50/60Hz Lumen 21050Lm Dimmension 848X385 X118mm N.W 14.8kg Coverage 1.5 X1.0 m Warranty 50000 hours
Supplier: Wireless charger, batteries power bank, dust sensor, optical disc drive, tof, lidar, ar glass
Do sensor dissolved oxygen sensor water quality control sensor kds-25b Model number: kds-25b Description The gs yuasa dissolved oxygen sensor kds-25b is a unique Galvanic cell type sensor which was developed for water quality Control. Its most notable features are long life expectancy and it Is not influenced by co2. Features: * long life * virtually no influence from co2 * no external power supply required for sensor Operation * no warmup time is required Applications: * water quality control
Wq-fdo optical dissolved oxygen sensor description The wq-fdo optical dissolved oxygen transmitter is an instrument designed for measuring dissolved oxygen concentrations in liquids. The wq-fdo optical dissolved oxygen transmitters were developed to meet different requirements ranging from surface water monitoring programs to harsh waste water applications. The optical dissolved oxygen transmitter has been specifically designed to meet the demanding requirements of the environmental monitoring and scientific research sectors, providing long term, accurate and reliable dissolved oxygen measurement. The wq-fdo optical dissolved oxygen transmitter has extremely low power requirements and a 4-20 ma output making it ideal for incorporation into remote environmental monitoring installations. Wq-fdo optical dissolved oxygen sensor features * extremely fast and precise optical do sensor - outstanding for field and lab applications * proven green light technology for long operation life of sensor * beveled membrane repells interference that can be caused by air bubbles * universal protective armoring available * low power consumption and low maintenance * simple to integrate and operate * one year sensor life Wq-fdo optical dissolved oxygen sensor applications Long and short term monitoring for streams, rivers, lakes, aquaculture, thermocline profiling, industrial outfalls, wastewater, scientific research, homeland security, the food and wine industry, and more. Wq-fdo optical dissolved oxygen sensor specifications * dissolved oxygen accuracy: â± 0.5 % of value * dissolved oxygen repeatability: 0.01 ppmâ?? * temperatureâ?? accuracy: â±0.2'f (â±0.1'c)â?? * temperatureâ?? resolution:â?? 0.02'f (0.01'c)â?? * temperatureâ?? range: 32 to 122'f (0 to 50'câ?? * max pressure: 35 psi (25m/82ft water depth)â?? * operating voltage: 10-30 vdcâ?? * warm up time: 6 sec. Min, 8 recommendedâ??