1. General VS1 12KV vacuum circuit breaker VCB HVD1-12(VS1-12) type indoor AC HV vacuum circuit breaker VCB (hereinafter referred to as circuit breaker) are suitable for 12kV air-insulated indoor switchgears, used as protection and control unit of power equipment of industrial& mining enterprise. Due to the super excellence, it is especially for location where requires the frequent operation of rated working current or multi breaking short circuit current. The circuit breaker adopts the integrated design of operating mechanism and circuit breaker body, servers as not only fixed installation, but also the handcart unit through equipping with a special propelling mechanism. 2. Service conditions 3.1 Environment temperature:-15degree~+40degree; 3.2 Environment humidity: Daily average relative humidity:
1. General HVD32 ZW32 This vacuum circuit breaker VCB is three-phase AC 50Hz, rated voltage 12 kV outdoor high voltage switch equipment. It is mainly used to opening(closing) load current, overload current and short-circuit current. It is suitable to protect or control the city or village electrical power distribution system. 2 . Main technical parameter Rated voltage: 12 kv 1 minute rated power frequency withstand voltage: Phase to Phase, to Ground 42 kv / Fracture 48 kv Rated current: 630A / 1250A Rated short circuit breaking current: 12.5KA, 16KA, 20KA / 25KA Rated short-circuit current (peak): 31.5KA, 40KA, 50KA / 63KA Rated peak withstand current: 31.5KA, 40KA, 50KA / 63KA 4s rated short time withstand current: 12.5KA, 16KA, 20KA / 25KA Rated operating sequence: O-0.3s-CO-180s-CO(Electric operation) Closing time: 30-60 ms Opening time: 20-40 ms Rated short circuit breaking current breaking times: 30 times Mechanical life: 10,000 times Secondary circuit 1 minute power frequency withstand voltage: 2000 v Energy storage motor rated power: 40 w Energy storage motor rated voltage V: DC220/110 Rated closing operation voltage v: DC220/110, AC220/110 Rated switching operation voltage v: DC220/110, AC220/110 Electric energy storage time: =8 s
VS1-12 type indoor high voltage vacuum circuit breaker is the indoor switch device for three-phase AC 50Hz, rated voltage 12kA power system, can be used for electrical equipment control and protection in power plant, substation and industrial and mining enterprises, and is suitable for frequent operation place, can be installed in the KYN28-12 type and other armored cabinet, can also be installed on the fixed cabinet or gas insulated cabinet. Design feature VS1-12kV indoor medium voltage sealed vacuum circuit breaker (12kV, .4000A, .50kA) VS1 indoor medium voltage sealed vacuum circuit breaker with maintenance free sealed vacuum pole, can equipped with modular spring assembling actuator and permanent magnetic actuator; has the features of reliable performance, long mechanical life, maintenance free, small mechanical movement, has the advantages of simple structure, good process performance, but also can be applied to all kinds of bad working environment. VS1 circuit breaker pole adapts the solid insulation sealing technology, seal the vacuum interrupter and primary main galvanic circle and other parts into strong insulation, high mechanical strength pole with epoxy resin, avoid the influence of adverse operating environment on the primary circuit external insulation, realizes completely maintenance free. VS1 circuit breaker adapt ultra low resistance type vacuum interrupter, meet the VCP circuit breaker requirements on the temperature rise at big current operation situation and reduces the power losses. VS1 circuit breaker adapt optimization and modular spring operating mechanism, simple structure, stable performance, convenient maintenance; modular production process is good, easy standardization production, short delivery cycle.
HVD1-12(VS1-12) type indoor AC HV vacuum circuit breaker VCB (hereinafter referred to as circuit breaker) are suitable for 12kV air-insulated indoor switchgears, used as protection and control unit of power equipment of industrial& mining enterprise. Due to the super excellence, it is especially for location where requires the frequent operation of rated working current or multi breaking short circuit current. The circuit breaker adopts the integrated design of operating mechanism and circuit breaker body, servers as not only fixed installation, but also the handcart unit through equipping with a special propelling mechanism.
1.With the voltage of 40.5kV is three-phase AC, 50/60 Hz indoor power distribution equipment. 2.It is used for switchgear KYN61-40.5(Z) 3.It is accordance with GB1984 AC HV vacuum circuit breaker standard. 4.It effectively reduces the dimensions of VCB, the overall arrangement is reasonable and simple,with aesthetic appearance. 5.It has high reliable with characteristics of long life and easy maintenance and free-maintenance for operating mechanism. 6.Meet the Five Preventions function.
1.Use spring energy storage. 2.Operating by two ways: manual or electric operation 3.The characteristics is accordance with GB1984-2003 AC High Voltage Circuit Breakers, JB3855-96 3.6~40.5kV indoor AC HV vacuum circuit breaker, relevant regulations of IEC62271-100 standard and the technical requirements of this product. 4.Use modular type operating mechanism and embedded pole The mechanical life is M2 and electrical life is E2
Vacuum Circuit Breaker HVD1-12KV 1250A 25KA VCB with copper parts 210mm phase distance HVD1-12(VS1-12) type indoor AC HV vacuum circuit breaker (hereinafter referred to as circuit breaker) are suitable for 12kV air-insulated indoor switchgears, used as protection and control unit of power equipment of industrial& mining enterprise. Due to the super excellence, it is especially for location where requires the frequent operation of rated working current or multi breaking short circuit current. The circuit breaker adopts the integrated design of operating mechanism and circuit breaker body, servers as not only fixed installation, but also the handcart unit through equipping with a special propelling mechanism. 2. Service conditions 3.1 Environment temperature:-15®C~+40®C; 3.2 Environment humidity: Daily average relative humidity:95%, monthly average relative humidity:90%; Daily average saturated vapor pressure:2.210-3Mpa,monthly average saturated vapor pressure:1.810-3Mpa; 3.3 Altitude: Not exceed 1000m; 3.4 Earthquake intensity: Not exceed°ree; 3.5 Service location: No water, flammable or explosive matter, chemical corrosive gas or drastic vibration. 1.Main specifications and technical parameters Rated voltage: 12 kv Rated lightning impulse withstand voltage(1min): 75 kv Rated short-time power frequency withstand voltage (1min): 42 kv Rated short-circuit breaking current: 25KA Rated current: 1250A Rated peak withstand current: 63KA Rated shorted-time withstand current: 25KA Rated shorted-time making current(peak): 63KA Power frequency withstand voltage of secondary circuit(1min): 2000 v Opening time(rated voltage): 20~50 ms Closing time(rated voltage): 30~70 ms Rated short-circuit current breaking times: 50(40kA 30) times Mechanical life: 30,000 times
Industrial electrical wires and cables, ups systems and ancillary, junction boxes, mccb, relays and various other electrical products and equipment..We believe in quality, cost effectiveness and timely service. we try to understand and do the best as per the client requirements.
1.General HVD85 ZN85 33kv 36KV indoor vacuum circuit breaker VCB is suitable for three-phase AC power system of 50Hz and 36kV, used to make and break the load current, overload current and fault current in industrial and mining enterprises, power plants and transformer substations, meanwhile, it is suitable for the occasion where the frequent operation is required. 2. Service conditions 2.1The ambient air temperature should be -15?~40?, the daily average temperature should not exceed 35?. 2.2 Daily mean relative humidity should not exceed 95%, and the daily mean vapor pressure should not exceed 2.2kPa; the monthly mean relative humidity should not be higher than 90%, and the monthly mean vapor pressure should not exceed 1.8kPa. 2.3 Altitude: Not exceed 1,000m. 2.4 The ambient air should be free from the dust, smoke, corrosive and flammable gas, steam, salt fog, et… Main specifications and technical parameters Rated voltage: 33KV 36kv Power frequency withstand voltage: 95 kv Lighting impulse withstand voltage: 185 kv Rated current: 1250A, 1600A, 2000A Rated short-time withstand current: 25KA, 31.5KA Rated peak value withstand current: 63KA, 80KA Rated short-circuit duration: 4 s Rated short-circuit breaking current: 25KA, 31.5KA Rated short-circuit making current: 63KA, 80KA Rated operation sequence: O-0.3s-CO-180s-CO Breaking time:
1. Introduction HVD7 33KV 36kv outdoor HV AC vacuum circuit breaker VCB has many visual advantages like reasonable design, fashionable appearance, high safety and reliability, simple maintenance, long electric life. It is the ideal upgraded products of 35KV outdoor oil circuit breakers. HVD7-40.5 vacuum circuit breaker is applicable for three-phase power system of AC 50HZ.It is used to make and break the load current ,overload current and short-circuit current. 2. Applicable environment 3.1The ambient temperature should be -30degree~ +40degree(-40degree in the frosty area); 3.2Altitude should not exceed 2000m(over 2000m is plateau type); 3.3The wind pressure should not exceed 700Pa(equal to wind speed 34m/s); 3.4Air pollution degree: 3,that of antifouling type:4; 3.5The installation site should be free from the fire, explosion, chemical corrosion and serious vibration. 1. Main technical parameters Rated voltage: 33kv 36KV 1 minute power frequency withstand voltage, dry test: 95 kv 1 minute power frequency withstand voltage, wet test: 80 kv Lightning impulse withstand voltage(peak value): 185 kv Rated current: 1600A / 2000A Rated short-circuit breaking current: 20KA, 25KA, 31.5KA Rated short-circuit making current(peak): 50KA, 63KA, 80KA Rated operating sequence: O-0.3s-CO-180s-CO Rated short-time withstand current: 20KA, 25KA, 31.5KA Rated peak withstand current: 50KA, 63KA, 80KA Rated short-circuit duration: 4 s Rated control voltage: AC220,110;DC220,110 Rated short-circuit breaking current break times: 20 times Full-break time:
Vacuum circuit breaker serves in the power system of 10kv and three-phase ac 50hz to function as switching different kinds of loads needing frequent operation, and can protect and control electric equipment in the industrial & mineral enterprise, power plant and substation as well. It can coordinate with the kyn28a-12(gzs1) middle-arranged manual-driven switchgear or xgn- stantionary switchger as well. Main technical parameter: Rated voltage 12kv Rated current 630~3150a Rated short-circuit breaking current 20~40ka Rated peak withstand current 50~100ka Rated short-time withstand current 20~40ka Rated duration short-time 4s Machanical endurance 20000 times Carton package
VN3-12E indoor medium-voltage AC vacuum circuit breaker is a newest product designed by our company which is applicable to 3-phases AC50Hz, 12kV indoor switch systems. The product is with characteristics of smaller volume, reliable insulation, no pollution, long time free maintenance and so on. It is produced with standardized circuit breaker assembly line and has good performance and perfect quality. 1. Equipped with modularized operating mechanism which make the maintenance and the replacing are more convenient. The replace of module do not affect the dynamic capability and also shorten the power-off duration. 2. The interrupter and primary circuit are sealed in the epoxy resin, which makes the circuit breaker is more reliable 3. The pole using convected and ventilated technique and lower resistance vacuum circuit breaker limit the temperature rising because of circuit breaker working for a long time and also reduce the power loss. 4. The operating mechanism is designed uniquely and avoids the moving contact over-rebounding when the circuit breaker is opened and prolong the vacuum interrupter mechanical life. 5. Past the type test according to the national standards such as GB, DL, international standards of IEC, CEI, DIN, VDE and other major industrialized countries.
VN2-24 indoor high voltage AC vacuum circuit breaker is a new designed our which is applicable to air-insulated indoor switch system. The whole structure is assembled with the switch body and operating mechanism. It is produced with standardized circuit breaker assembly line and has good performance and perfect quality. 1. Have a wide range with rated current from 630a to 3150a and rated short-circuit breaking current from 20ka to 31.5ka. The mechanical life can be up to 20000 cycles. 2. Be intended for indoor installation in air-insulated switchgear and have fixed version or withdraw able version. 3. Have perfect switching-capacity which can handle any condition arising from switching of equipments and components under normal operating or fault conditions particularly short-circuit and over-load. 4. Adopt coopers vacuum interrupter which is smaller volume, lower resistance, longer lifetime, better atmosphered technique, more perfect insulation and higher breaking capacity. 5. Be with more perfect external insulation because of the vacuum interrupter and main circuit being cast in epoxy resin poles. 6. Comply with stipulations defined in standards of gb, gl, iec, cei, din, vde and other major industrialized countries.
Vacuum circuit breaker Our products are inexpensive and have super quality. All products have passed the iso9001 international quality certification, some model passed europe certificate for e-mark.. We can provide all sorts of products with advantage in technology, quality and cost.
VIB-24 Indoor High Voltage Vacuum Circuit Breaker is a new generation vacuum circuit breaker for Shaanxi Shaankai-Longxiang Electrical Ltd. It is independently designed and developed by our-selves on the basic of absorbing the merit of same type for the products at home and abroad. The Product conforms to national standard GB1984-2003 , JB3855-1996 , DL/T403-2000 and some stipulation of IEC, the capability reach requirement of M2-E2-C2 grade. VIB-24 Indoor High Voltage Vacuum Circuit Breaker adopt the incorporate design with operating mechanism and reality of VCB, it can be used for fixed installation unit and also can be used for withdrawable by equipped with mainstream Switchgear.
Appearance White or Light Yellow Emulsion pH 6.5-8.5 Emulsion Lonic Weak Anionic Appropriate Thinner 10-30 â?? Water Thickening Standard GB/T 26527-2011 Organic Silicon Defoamer 1. The defoamer is composed of polysiloxane, modified polysiloxane, silicone resin, white carbon black, dispersing agent and stabilizer, etc. 2. At low concentrations, it can maintain good elimination bubble suppression effect. 3. Foam suppression performance is prominent 4. Easily dispersed in water 5. The compatibility of low and foaming medium 6. To prevent the growth of microorganisms Advantage It is composed of dispersant and stabilizer, low dosage, good acid and alkali resistance, stable chemical properties, easy to disperse in water, effectively prevent bacterial growth. The properties are stable during storage. Application 1. Papermaking chemical pulping high temperature vacuum or pressure in the defoaming in pulp washing machine 2. When the alkali refining agent of textile industry, inhibit elimination of treatment before 3. Circuit board cleaning 4. Oil mud defoaming in the process of mining 5. Textile printing and dyeing processing 6. Agricultural chemicals
TERASAKI TEMPOWER ACB TYPES: AT06, AT16, AT12, AT20, AT25, AT32, AT40. TERASAKI TEMPOWER ACB Type AGR-11B,21B,22B,31B Overcurrent Protective Device) Types: AR208S, AR212S, AR216S, AR220S, AR325S, AR332S, AR440S, AR440SB, AR212H AR216H, AR220H, AR316H, AR320H, AR325H, AR332H, AR420H, AR440H.
VACCUM CIRCUIT BREAKER ALL TYPE OF ABB VACCUM CIRCUIT BREAKER VD4 12.12.25 , VD4 12.12.40, VD4 07.12.25.... MANY MORE 11 KV , 33KV . VD4Medium voltage vacuum circuit-breaker12 kV - 1250...4000 A - 63 kA36/40.5 kV - 630...3150 A - 16...40 kAMedium Voltage Products The VD4 are a synthesis of the renownedtechnology in designing and constructing vacuuminterrupters embedded in resin poles, and ofexcellency in design, engineering and productionof medium voltage circuit-breakers.Embedding the interrupter in resin makes thecircuit-breaker poles particularly sturdy andprotects the interrupter against shocks, accumula-tion of dust and humidity.The vacuum interrupter houses the contacts andmakes up the interrupting chamber.
Yangzhou new concept electric co., ltd. Has independently developed 72.5kv intelligent phase selection (synchronous) hv permanent-magnetic vacuum circuit breaker (hereinafter referred to as "intelligent circuit breaker") at world advanced level by integrating domestic and foreign advanced technologies, adopting the new design concept and applying hi-tech means. With permanent-magnetic mechanism, vacuum arc extinction, integrated sensor and arm+dsp processor, this intelligent circuit breaker self-adapts to own parameters and the impact of environment, thus being the first choice for the realization of power grid intelligentization. This product conforms to iec60298, gb3906-2006, gb/t 11022-1999, dl/t 593-2006, gb 1984-2003 standards, etc. major technical parameters are shown below: Rated voltage 72.5kv Rated current 1600/2000/2500a Rated frequency 50hz Rated short-duration (1 min) power frequency withstand voltage 160kv Rated short-circuit breaking current 31.5ka Thermal stability current(4s) 31.5ka Rated lightning impluse withstand voltage(to earth/break) 350kv Dynamic stability current(peak value) 80ka Rated short-circuit current breaking times 20 times Operating time 40-60ms Operating voltage Ac/dc220v Mechanical service life >10000 times Main circuit resistance