Nominal Current(RMS):200/400/800/1000/1200/2000A Vout@Ipn:+_4.000V Measuring Range:0~+_4000A Supply Voltage DC:+-12-15V Accurancy@Ipn,+25degree Celsius:less than +_1.0% Mounting(mm):40.5 in diameter * Open- loop * Supply voltage: DC +-12~15V * Capable measurement of currents: DC, AC,pulse with galvanic isolation between primary circuit and secondary circuit.
Nominal Current(RMS):200/400/800/1000/1200/2000A Vout@Ipn:+_4.000V Measuring Range:0~+_3000A Supply Voltage DC:+-12-15V Accurancy@Ipn,+25degree Celsius:less than +_0.5% Mounting(mm):12.5*41.0
Nominal Current(RMS):25/50/75/100A Vout@Ipn:+_25/50V Measuring Range:0~+_150A Supply Voltage DC:+-12-15V Accurancy@Ipn,+25degree Celsius:less than +_0.5% Mounting(mm):7.0*12.7  * Closed- loop                                        * Supply voltage: DC +-12~15V  * Capable measurement of currents: DC, AC,pulse with galvanic isolation between primary circuit and secondary circuit.
Input: AC/DC 20-100A; Output: DC 4-20mA; Accuracy: 1.0%; Power supply: DC 12V, 15V, 24V.
Input: AC/DC 20-100A; Output: DC 0-5V; Accuracy: 1.0%; Power supply: DC 12V, 15V, 24V.
Nominal Current(RMS):30/300A Vout@Ipn:2.500+_2.000V Measuring Range:+_30/+_300A Supply VoltaIpn,+25
Type : RTCS100B,RTCS200B,RTCS300B,RTCS400B,RTCS500B,RTCS600B, IPN Primary nominal input current : 100, 200, 300, 400, 500, 600 A IP Measuring range of primary current : 0~300, 0~600, 0~900, 0~900, 0~900, 0~900 A VOUT Nominal output voltage : 41%V VC Supply voltage : 15(5%) V IC Current consumption : VC=15V
Type : RTCS050EK1, RTCS100EK1, RTCS200EK1, RTCS300EK1, RTCS400EK1, RTCS500EK1 IPN : Primary nominal input current : 50, 100, 200, 300, 400, 500A IP Measuring range of primary current : 0~¡À100, 0~¡À200, 0~¡À400, 0 ~¡À600, 0~¡À800, 0~¡À1000 A VOUT Nominal output voltage : 4¡À1%V VC Supply voltage : ¡À12~¡À15(¡À5%)V 20 pcs/inner,200 pcs/CTN,14.5 KGS,40x25x30CM.
Input: AC 0.5A-5A; Output: DC 0-5V; Accuracy: 0.2%; Power supply: DC 9-36V.
Input: DC 10mV-1000V; Output: DC 4-20mA; Accuracy: 0.2%; Power supply: DC 9-36V.
Input: AC 0.5A-5A; Output: DC 4-20mA; Accuracy: 0.2%; Power supply: DC 9-36V.
Input: DC 10mV-1000V; Output: DC 4-20mA; Accuracy: 0.2%; Power supply: DC 12V, 24V.
Input: DC 10mV-1000V; Output: DC 4-20mA; Accuracy: 0.2%; Power supply: DC 12V, 24V.
Current sensors, hall effect sensors, voltage sensors and frequency sensors.
PPTC, transistors, hall effect sensors, Ics.
Hall components have many advantages, they are strong construction, small volume, light weight, long service life , easy installation, wide bandwidth ( can reach 1 MHZ);vibration resistance, Not afraid of pollution or corrosion of dust ,oil, greasy dirt, moisture , salt mist and so on. • Hall linear elements are excellent accuracy, good linearity. Hall switch elements are no contactless, no in-gage, clear output waveforms, no instant jitter, high-precision positional repeatability. In recent years, with the development of China aerospace industry .Our hall-effect product is widely used in new rocket ,new generation communication satellite, new navigation satellite, new recoverable satellites, chang-e satellites, Shenzhou spacecraft and so on . Its related products is also can widely used in automotive matching, environmental protection, medical equipments, instrument, power protection, office automation and many other civil fields. It is wildly used in frequency driver, contravariant devices, UPS, contravariant welding machine, converting station, electrolyze & electroplating, CNC machine, PC monitoring, grid monitoring, insulated current & voltage testing, Etc. Working Principle 1.Direct measurement principle 2.Magnetic compensation principle Packed in box ,can be customized
Rated input current AC 50A, 100A, 400A AC/DC Accuracy 1.0 Input Impedance (R) approximate zero Linear measuring range 0 - 1.2 times of rated input current Over Load Capacity 30 times of rated input current, 5s Frequency range 25Hzï½?5kHz Isolation Voltage(Input/Output) â?¥2500Vdc, for 1 minute Thermal drift 600ppm/°C Ambient Temperature -25ï½?+70 Mounting DIN Rail 35mm Mounting or screw mounting
Rated input current AC 50A, 100A, 400A AC/DC Accuracy 1.0 Input Impedance (R) approximate zero Linear measuring range 0 - 1.2 times of rated input current Over Load Capacity 30 times of rated input current, 5s Frequency range 25Hz~5kHz Isolation Voltage(Input/Output) 2500Vdc, for 1 minute Thermal drift 600ppm/ Ambient Temperature -25~+70 Mounting DIN Rail 35mm Mounting or screw mounting
electronic components, PPTC, transistors, hall effect sensors, Ics.
I221LY05-25 I222LY05-25 I224LY05-25 Output signals 0-5V AC/DC 0-5V DC 4-20mA Responding time 50us 100ms 150ms Power supply ±12V, ±15V DC ±12V, ±15V, +12V, +24V DC