inflammation series 3.0-4000.0 pg/mL Serum/Plasma/Whole blood SerumPlasma100ul Wholeblood120ul 15Min
Stroke 0.08-10ng/ml Serum/Plasma/Whole blood SerumPlasma100ul Wholeblood120ul 15Min.
Diabetes 3%-15% Whole Blood Dilute and add specimen100ul 15Min
Automatic 3ply medical mask machine one to two for outer earloop Foil and Wooden carton 1x40GP
Renal Function 10-1500 ng/ml Serum/Plasma/Whole blood SerumPlasma100ul Wholeblood120ul 15Min.
Bone calcium 5-120ng/ml Serum/Plasma/Whole blood Pre-treatment and add specimen100ul 15Min
Gastric Function 1.0-40.0 pmol/L Serum/Plasma/Whole blood SerumPlasma100ul Wholeblood120ul 15Min
Gastric Function PGI 1.0-200 ng/ml PGII 1.0-100ng/ml Serum/Plasma/Whole blood SerumPlasma100ul Wholeblood120ul 15Min.
Thyroid Function 0.15-12 ng/ml Serum/Plasm 15Min.
Thyroid Function 10-320 ng/ml Serum/Plasm 15Min.
Thyroid Function 0.05-80IU/ml Serum/Plasma/Whole blood 15Min.
Vaginal Speculum, Small , 20 X 70mm
Ventilator YH-830 bi-level PAP device CE certification and FDA certificate FOB Price USD 6.100/ Set Stock 300 units in stock today Payment term: T/T in advance. Delivery immediately after payment Technical parameters of YH-830 bi-level PAP device 1. Scope of application: For adult patients with ARDS, hypoventilation syndrome, for bi-level non-invasive ventilation in a hospital or home. 2. the main function: 1. Different treatment options can be provided according to patients' needs, from CPAP to S, T, S / T, VGPS five modes 2. Adjustable trigger sensitivity. 3. Real-time monitoring and recording of blood oxygen saturation. 4. alarm function. 5. Record function (SD card). 6. Maximum leak compensation function. 60L/min 7. With trolley, easy to move in the hospital 3. the key technical parameters: 1. Working mode: CPAP, S, T, ST, VGPS. 2. Ventilation parameters: 2.1 Inspiratory pressure: 4-30 cmH2O (0.5 cmH2O interval) 2.2 Expiratory pressure: 4-30 cmH2O (0.5 cmH2O interval) 2.3 Treatment pressure: 4-20 cmH2O (in CPAP mode, 0.5 cmH2O interval) 2.4 Delayed boost: 0-45 minutes (interval of 5 minutes) 2.5 Breathing frequency: 5-50 times / minute (interval 1 time / minute) 2.6 Breathing ratio: 10-70% (interval of 1%) 2.7 Rise time: 1-5 steps (1 step interval, 1 step rises fastest, 5 steps rises most slowly) 2.8 Inhalation sensitivity: 1-5 steps (1 step interval, 1st step triggers fastest, 5th step 1st step triggers slowest) 2.9 Exhalation sensitivity: 1-5 (1 interval, the 1st trigger is the fastest, 5th and 1st the slowest) 2.10 Tidal volume: 50-1500ml (effective in VGPS mode, interval 50ml) 3.VGPSï¼?same with AVAPS, can set Target tidal volumeï¼? 3.1 Maximum IPAP value adjustable range: 4-30 cmH2O 3.2 Adjustable range of minimum IPAP value: 4-30 cmH2O 3.3 EPAP value adjustable range: 4-30 cmH2O 3.4 Target Tidal Volume: 50-1500ml 4. Display range of monitoring setting parameters: 4.1 Respiratory waveform can be displayed; 4.2 Current mode: CPAP, S, T, ST, VGPS 4.3 Inspiratory pressure: 4-30 cmH2O 4.4 Expiratory pressure: 4-30 cmH2O 4.5 Breathing frequency: 5-50 times / minute 4.6 Breathing ratio: 10-70% 4.7 Air leakage: 20-99.9lpm 4.8 Tidal volume: 50-1500ml 4.9 minute ventilation: 0-50lpm 4.10 Blood oxygen saturation: 70-100% 4.11 Pulse rate: 25-250bpm 4.12 Delay boost: 0-45 minutes 6.Specifications 6.1 Weight: about 20kg including the trolley and the device 6.2 Operating temperature: 5-35 C 6.3 Relative humidity: 10% -90% 6.4 Power supply: input is AC 100-240V, 50-60Hz, 1.8A Max; output: DC 24V, 3.33A.
Innovative pvc free elastomeric pump, realized to satisfy all the need of the infusion of drugs not compatible with pvc. It is light, resistant, transparent, ergonomic an easy to use. It is indicated for intravenous, subcutaneous and epidural administration of antibiotics, chemotherapeutic agents and other medications or fluids requiring continuous delivery at controlled infusion rates. The silicone medical grade balloon in the pump assures the highest grade of non inter-action with most drugs. It is avalaible in different capacities of 60 ml, 100 ml, 200 ml and 275 ml - continuous and bolus type. Our pump is easy to set up and use. No special training or filling equipment is required. Our product is the best guarantee we can give you.
Suitable for anaesthesia-single analgesia within he sub-arachnoid space and in particular in the lumbar region. All needles have a mandrin assuring a perfect needle lumen closure. The smallest needles, may be supplied with mounted introducer compensating the needle fexibility and consequentely favouring its introduction and positioning. Pencil point-whitacre special conical tip ensures an higher penetrability and the position of lateral lumen allows the ligaments, nerves, vessels crossing in absolute safety and also minimizing the incidence of post dural puncture headaches.
Catheter in radiopaque fep or pu , coded coloured sizes, luer lock connectors, maximus safety with horizontal silicon valve, aisi stainless tell specially shaped, optimised tapered tip profile for easy catheter introduction.
Infusion set-pvc free-dehp free
Medical devices indicated for extension and/or additional infusion set connection for administration of parenteral and Pyrogen free single use only. Ethylene oxide gas sterilization according validate method (uni en 11135). Store the product in close boxes far from direct light, in dry environments at temperature less then 40°c. Shelf life: 5 years.
Nitrile gloves.
Nitrile gloves.