Product Details: Brand : Boditech Med Incorporated Size : 25 Test Samples : Whole blood Sample volume : 75 Microliter Cat No : CFPC-38 Storage Temperature ; 4 - 30 DegreeC HbA1c Assessing the level of glycated hemoglobin in the blood This test is certified by NGSP (National Glycohemoglobin Standardization Program). It helps diabetic diagnosis, treatment, and prognosis by measuring the glycated hemoglobin concentration (%) in a small amount of blood over the past 3 months. INTENDED USE ichroma HbA1c is a fluorescence Immunoassay (FIA) for the quantitative determination of HbA1c(Hemoglobin A1c) in human whole blood. It is useful as an aid in management and monitoring of the longterm glycemic status in patients with diabetes mellitus. For in vitro diagnostic use only. PRINCIPLE: The test uses a sandwich immunodetection method; the detector antibody in buffer binds to antigen in sample, forming antigen-antibody complexes, and migrates onto nitrocellulose matrix to be captured by the other immobilized-antibody on test strip. The more antigen in sample forms the more antigen-antibody complex and leads to stronger intensity of fluorescence signal on detector antibody. Instrument for ichromaâ?¢ tests displays the content of glycated hemoglobin in terms of percent of the total hemoglobin in blood.
Product Details: Brand arkray Model Name/Number A1c Sample Mode Whole Blood Measuring Principle Boronate affinity Power Supply AC100 V-240 V +-10 % 50/60 Hz Weight Instrument: 0.7 kg Printer: 0.5 kg Dimensions (W x D x H) W 205 x D 135 x H95 mm Detection method Fluorescence quenching Specifications: Samples Whole blood (capillary and venous blood) Measured items HbA1c Measurement principle Boronate affinity Detection method Fluorescence quenching Measurement range NGSP : 4-15 Throughput 4 minutes per sample Sample volume 4 L(whole blood) Imprecision CV < 3 % at 7 % A1c (NGSP) Measurement conditions 18-30 , 20-80 relative humidity Memory capacity 7000 test results Printer Thermal printer, 58mm thermal paper (Optional) External output USB Port Power supply AC100 V-240 V ±10 % 50/60 Hz External dimensions W 205 x D 135 x H95 mm Weight Instrument: 0.7 kg Printer: 0.5 kg Warm up time 5-20 mins dependent upon external temp conditions
Product Details: Sample Volume 4 Micro L Measuring Time In 5 minutes Model No HbA1c 501 Dimensions (W x D x H) 198 x 217 x 136 mm Power 9 V DC / 1.5 A HemoCue HbA1c 501 System is a fast, easy and reliable point-of-care system for hemoglobin A1c tests. It is a fully automated HbA1c POC test that provides reliable results straight away for efficient diabetes care. Stop sending samples to labs and waiting for results Having to send blood samples to the lab and wait for the results to come back can be very frustrating. Not only is it time-consuming, it also delays the treatment of the diabetes patients. As a medical professional, you should be able to carry out tests fast and easy at the point of care, and provide your patients with reliable result straight away. An automated system for testing HbA1c HemoCue HbA1c 501 System is a fully automated point-of-care system for testing HbA1c. Hemoglobin A1c (HbA1c) is a glycated form of Hb that is tested primarily to identify the average amount of glucose (sugar) present in patients blood over the past three months. Blood sugar testing is an important part of the diabetes care and necessary for millions of diabetics. Advantages of using our point-of-care system Our HemoCue HbA1c 501 System brings many advantages into your work process. It provides a safe workflow for excellent patient care. Every step of the test is simplified to minimize human errors. Every element from size to the storing and handling of test cartridges is designed to be ideally suited for how you work. The system is easy to use, the tests are carried out quickly, and the results are exceptionally reliable. With our system, you will never have to doubt an answer at the point of care. Onscreen instructions simplify every step of the process Testing HbA1c with our system includes only a few simple steps. But to make it as easy as possible for you to carry out the tests, we provide you with clear online instructions animated on the screen. They describe exactly how you should do so that you never have to feel insecure about performing the tests. Certified according to IFCC and NGSP to ensure quality The HemoCue HbA1c 501 system is certified according to the International Federation of Clinical Chemistry & Laboratory Medicine (IFCC) and the National Glycohemoglobin Standardization Program (NGSP). It ensures that our system has a measuring range of 20-130 mmol/mol (IFCC) or 4.0-14.0% (NGSP) to ensure the quality of the tests. Get the right answers at the right time every time In the end, the result of the test is what decides the treatment of your patient. The test must not vary from time-to-time, on the contrary, it needs to be accurate every single time.
Product Name Glycosylated Hemoglobin(HbA1c)Test Kit (Immunofluorescence Chromatography) Purpose To detect the content of HbA1c in human whole blood in vitro quantitatively.For Professional Use only. Principles of Detection The HbA1c Test is a fluorescent lateral flow immunoassay. The test consists of: 1) a conjugate pad containing HbA1c antibody conjugated with fluorescent microspheres and a control antibody (goat anti-chicken IgY antibody) conjugated with fluorescence microspheres, 2) a nitrocellulose membrane strip containing a test line (T line) and a control line (C line). The T line is pre-coated with another HbA1c antibody, and the C line is pre-coated with a control line antibody (chicken IgY antibody). HbA1c concentration in specimen is positively correlated with the fluorescent density of the microspheres, after the measure and calculation of the quantitative fluorescence immunoassay analyzer, then the analyzer would calculate the concentration of HbA1c according to the preset calibration curve in the machine and display the result, detection unit is %units. C line should appear in any cases, which indicates the reaction system is effective. Storage conditions and shelf life Store in a sealed aluminum foil bag at 2~30�°C. After unpacking the aluminum foil bag under temperature 20~30 �ºC , humidity 35~65%, please use it immediately. Shelf life 18 months. Applicable instrument Avid fluorescent immunoanalyzer model: AI-IF 600 Manufacturer& After-Sales Company: Shenzhen Aivd Biotechnology Co., LTD. Address:C501,Building B5,China Merchants Guangming Science Park, #3009 Guanguang Road, Guangming District, Shenzhen,Guangdong Province, China Tel: 0755-26165742 Fax:0755-26401805 Specimen collection and preparation 1. Human whole blood samples can be used for this test. 2. Specimen collection:Collect blood specimen into a collection tube containing EDTA , evenly mixed before use. Do not use hemolyzed blood for testing. Whole blood specimens should be stored at 2-8�°C for no more than 4 hours if not test immediately. 3. Do not test patients' samples with severe hemolysis, lipemia and jaundice, all specimens should be treated as infectant. 4. Restore the specimen to 20-30�°C before the detection, cryopreserved specimen should be completely thawed, rewarmed and evenly mixed before use. Reference range Positive: reading value â?¥6%, a positive result. Negative: reading value 8%, poorly controlled blood glucose. The reference value is verified with reference to similar products that have been marketed. Due to ethnic and geographical differences, each laboratory can establish its own reference interval according to the actual situation.
Supplier: Blood glucose meter, blood glucose monitoring system, HBA1C analyzer
Supplier: Automatic chemistry analyzer, blood glucose monitor and strip, HBA1C
Supplier: Glucose meter, cholesterol meter, HBA1C, disinfectant wipes, auto tube labeler
Supplier: Covid 19 antigen rapid test kit, antibody test, antigen test, poct, point of care testing, hba1c, bgms for human and pets, blood glucose monitoring system, diagnostic reagents, diagnostic instruments, medical devices, glucose, lipid(tc, tg, hdl, cal ldl) monitoring system, hemoglobin measuring system
Handheld Glucose, Lipid(TC, TG, HDL, Cal-LDL) Monitoring System The GREENCARE LIPID is an in vitro diagnostic medical device for measurements of total cholesterol, triglycerides, HDL cholesterol in whole blood by colorimetric assay with enzyme reaction. And the GREENCARE LIPID is an in vitro diagnostic medical device that can diagnose diabetes by measuring blood glucose through electrochemical reactions.