Product Details: Brand : Boditech Med Incorporated Size : 25 T Samples : Human serum/plasma/ control Specimen volume : 75 Microliter stored at ; 4 - 30 DegreeC Cat No ; CFPC-44 T3 Assessing to diagnosis & to monitor thyroid diseases(T3) This test assesses the level of T3 in the blood to diagnose thyroid dysfunction, help to receive appropriate treatment, and help to confirm the treatment effect through periodic measurement. INTENDED USE : ichroma T3 is a fluorescence Immunoassay (FIA) for the quantitative determination of triiodothyronine (total T3) in human serum/plasma. It is useful as an aid in management and monitoring of determination of thyroid disorders. For in vitro diagnostic use only. PRINCIPLE : The test uses a competitive immunodetection method. In this method, the analyte in the sample binds to the fluorescence labeled (FL) detection antibody in detection buffer, to form the complex as sample mixture. This complex is loaded to migrate onto the nitrocellulose matrix, where the covalent couple of T3 and bovine serum albumin (BSA) is immobilized and interferes with the binding of analyte and fluorescence labeled (FL) antibody. If more analytes exist in the sample, less detection antibodies are accumulated, resulting in less fluorescence signal. MATERIALS SUPPLIED : REF CFPC-44 Components of ichroma T3 Cartridge Box: - Cartridge 25 - Detector tube 25 - Detector diluent 2 - ID chip 1 - Instruction for Use 1
Product Details: Number of Reactions(Preps)/Kit : 96 Wells Brand : CTK BioTech Sample Material : Serum Storage : 2-8 C Cat. No : E1015 Total T3 ELISA CE The Total Triiodothyronine (T3) ELISA is a solid-phase enzyme-linked immunosorbent assay based on the principle of the competitive ELISA technique for quantitative determination of Triiodothyronine in human serum. The three main kit components are: 1) Solid microwells pre-coated with anti-T3 2) T3 Calibrators 3) Liquid T3 Enzyme Conjugate Mixture comprised of T3 labelled with horseradish peroxidase (T3-HRP) Product Features: Analytical Sensitivity: 173 ng/mL at 2-SD Specificity: No cross-reactivity or interference with d-Thyroxine 10 aµg/mL d-Triiodothyronine 100 aµg/mL Iodotyrosine 100 aµg/mL Diiodotyrosine 100 aµg/mL TBG 50 aµg/mL Human Albumin 50 aµg/mL Phenylbutazone 25 aµg/mL Phenytoin 50 aµg/mL ASA 500 aµg/mL Acetaminophen 500 aµg/mL Accuracy: correlation coefficient 0.99 with a reference method Intra Assay Precision: CV a?¤ 7.5% Inter Assay Precision: CV a?¤ 10.76% Product Specification : Anti-T3 Ab Coated Microwells Total T3 Calibrators: C1 (0 ng/mL) C2 (0.5 ng/mL) C3 (1.0 ng/mL) C4 (2.0 ng/mL) C5 (4.0 ng/mL) C6 (8.0 ng/mL) Total T3 Assay Control Total T3 Enzyme Concentrate Enzyme Buffer Wash Buffer Concentrate TMB Substrate Stop Solution Product Insert
Product Name Triiodothyronine (T3) Test Kit (Immunofluorescence Chromatography) Purpose To detect the content of T3 in human plasma/serum/whole blood in vitro quantitatively.For Professional Use only. Principles of Detection The T3 Test is a fluorescent lateral flow immunoassay. The test consists of: 1) a conjugate pad containing T3 antibody conjugated with fluorescent microspheres and a control antibody (goat anti-chicken IgY antibody) conjugated with fluorescence microspheres, 2) a nitrocellulose membrane strip containing a test line (T line) and a control line (C line). The T line is pre-coated with another T3 antigen, and the C line is pre-coated with a control line antibody (chicken IgY antibody). T3 concentration in specimen is positively correlated with the fluorescent density of the microspheres, after the measure and calculation of the quantitative fluorescence immunoassay analyzer, then the analyzer would calculate the concentration of T3 according to the preset calibration curve in the machine and display the result, detection unit is nmol/mL. C line should appear in any cases, which indicates the reaction system is effective. Storage conditions and shelf life Store in a sealed aluminum foil bag at 2~30�°C. After unpacking the aluminum foil bag under temperature 20~30 �ºC , humidity 35~65%, please use it immediately. Shelf life 18 months. Reference range Reference value:The 95% concentrations of T3 in 239 non-stationary subjects without any obvious thyroid dysfunction ranged from 1.34 to 2.73nmol/L, with a median of 1.81nmol/L;The reference value has been verified with reference to similar products already on the market. Each laboratory can build own reference range according to actual situation.
Supplier: masks, surgical masks, gowns, covid 19 rapid test kits (ce, fda, and hrma approved), goggles, thermometer guns, 3 ply disposable masks, face shields, kn95 masks and t3, t4 and t5 suits
Buyer: masks, surgical masks, gowns, covid 19 rapid test kits (ce, fda, and hrma approved), goggles, thermometer guns, 3 ply disposable masks, face shields, kn95 masks and t3, t4 and t5 suits
Supplier: Elisa kits, clia kits, microplate, rapid test Hbsag elisa kit, HCV elisa, HIV 1+2 elisa, HTLV 1+2 elisa, T3 elisa, T4 elisa, TSH elisa, FT3 ELISA, FT4 elisa
Items Parameters Model : XXG-2005 Max. Penetration A3 Steel : 30mm Exposure Time : 5 minutes Film Type : T3 Input Voltage : AC198-240V/50Hz (60Hz) Capacity : 2.0kVA Ambient Temperature :-30~40 Ambient Humidity 85% X-ray Tube material : ceramic Emission : Directional Focal Size : 2 2.0mm Radiation Angle : 40 ° Output Voltage : 100-200kV Output Current : 5mA X-ray Generator Cooling : Fan Insulation : SF6 Pressure Gauge : 0.34MPa0.45MPa x ray generator Dimension : D285*H615mm x ray generator Weight : 24Kg Controller Dimension : 300300140mm Controller Weight : 8Kg
Items Parameters Model : XXQ-3505 Max. Penetration A3 Steel : 60 mm Exposure Time : 5 minutes Film Type : T3 Developing Time : 5 minutes Blackening : 1.5 Sensitivity : 1.8% Input Voltage : AC198-240V/50Hz (60Hz) Capacity : 3.5 kVA Ambient Temperature : -30~40 Ambient Humidity :85% X-ray Tube material : glass X-ray Tube Emission : Directional Focal Size : 2.52.5mm Radiation Angle : 40 ° Output Voltage : 180-350kV Output Current : 5mA X-ray Generator Cooling : Fan Insulation : SF6 Pressure Gauge : 0.34Mpa 0.45MPa X-ray Generator Dimension D345*H830 mm X-ray Generator Weight 48 Kg Controller Dimension 350290150mm Controller Weight 10Kg
Items Parameters Model :XXGH-3005 Max. Penetration A3 Steel : 47 mm Focal Length : 600 mm Exposure Time :5 minutes Film Type : T3 Operation Temperature in Darkroom : 20 Developing Time :5 minutes Blackening : 1.5 Sensitivity : 1.8% Input Voltage :AC198-240V/50Hz (60Hz) Capacity :3.5 kVA Ambient Temperature :-30~40 Ambient Humidity : 85% X-ray Tube material :ceramic X-ray Tube Emission :Panoramic Focal Size :1.02.5mm Radiation Angle : 360 ° * 25° Output Voltage :170-300kV Output Current : 5mA X-ray Generator Cooling : Fan Insulation : SF6 Pressure Gauge : 0.34MPa0.45MPa X-ray Generator Dimension : D320*H630 mm X-ray Generator Weight : 34 Kg Controller Dimension : 350290150mm Controller Weight :10Kg
Items Parameters Model : XXH-2505 Max. Penetration A3 Steel : 37 mm Exposure Time : 5 minutes Film Type : T3 Operation Temperature in Darkroom :20 Developing Time : 5 minutes Blackening : 1.5 Sensitivity : 1.8% Input Voltage : AC198-240V/50Hz (60Hz) Capacity : 2.5 kVA Ambient Temperature : -30~40 Ambient Humidity : 85% X-ray Tube material : glass X-ray Tube Emission : Panoramic Focal Size : 2.02.0mm Radiation Angle : 360 °x 30° Output Voltage : 150-250kV Output Current : 5mA x-ray Generator Cooling : Fan Insulation : SF6 Pressure Gauge : 0.34MPa0.45MPa X-ray Generator Dimension : D320*H730 mm X-ray Generator Weight : 35 Kg Controller Dimension : 350290150mm Controller Weight : 10Kg