Ventilator YH-830 bi-level PAP device CE certification and FDA certificate FOB Price USD 6.100/ Set Stock 300 units in stock today Payment term: T/T in advance. Delivery immediately after payment Technical parameters of YH-830 bi-level PAP device 1. Scope of application: For adult patients with ARDS, hypoventilation syndrome, for bi-level non-invasive ventilation in a hospital or home. 2. the main function: 1. Different treatment options can be provided according to patients' needs, from CPAP to S, T, S / T, VGPS five modes 2. Adjustable trigger sensitivity. 3. Real-time monitoring and recording of blood oxygen saturation. 4. alarm function. 5. Record function (SD card). 6. Maximum leak compensation function. 60L/min 7. With trolley, easy to move in the hospital 3. the key technical parameters: 1. Working mode: CPAP, S, T, ST, VGPS. 2. Ventilation parameters: 2.1 Inspiratory pressure: 4-30 cmH2O (0.5 cmH2O interval) 2.2 Expiratory pressure: 4-30 cmH2O (0.5 cmH2O interval) 2.3 Treatment pressure: 4-20 cmH2O (in CPAP mode, 0.5 cmH2O interval) 2.4 Delayed boost: 0-45 minutes (interval of 5 minutes) 2.5 Breathing frequency: 5-50 times / minute (interval 1 time / minute) 2.6 Breathing ratio: 10-70% (interval of 1%) 2.7 Rise time: 1-5 steps (1 step interval, 1 step rises fastest, 5 steps rises most slowly) 2.8 Inhalation sensitivity: 1-5 steps (1 step interval, 1st step triggers fastest, 5th step 1st step triggers slowest) 2.9 Exhalation sensitivity: 1-5 (1 interval, the 1st trigger is the fastest, 5th and 1st the slowest) 2.10 Tidal volume: 50-1500ml (effective in VGPS mode, interval 50ml) 3.VGPSï¼?same with AVAPS, can set Target tidal volumeï¼? 3.1 Maximum IPAP value adjustable range: 4-30 cmH2O 3.2 Adjustable range of minimum IPAP value: 4-30 cmH2O 3.3 EPAP value adjustable range: 4-30 cmH2O 3.4 Target Tidal Volume: 50-1500ml 4. Display range of monitoring setting parameters: 4.1 Respiratory waveform can be displayed; 4.2 Current mode: CPAP, S, T, ST, VGPS 4.3 Inspiratory pressure: 4-30 cmH2O 4.4 Expiratory pressure: 4-30 cmH2O 4.5 Breathing frequency: 5-50 times / minute 4.6 Breathing ratio: 10-70% 4.7 Air leakage: 20-99.9lpm 4.8 Tidal volume: 50-1500ml 4.9 minute ventilation: 0-50lpm 4.10 Blood oxygen saturation: 70-100% 4.11 Pulse rate: 25-250bpm 4.12 Delay boost: 0-45 minutes 6.Specifications 6.1 Weight: about 20kg including the trolley and the device 6.2 Operating temperature: 5-35 C 6.3 Relative humidity: 10% -90% 6.4 Power supply: input is AC 100-240V, 50-60Hz, 1.8A Max; output: DC 24V, 3.33A.