40 kva generator sets Motor brand : ricardo Alternator brand : gentech Cylinder numbers : 40 kva ( 4 cylinders ) Rpm : 1500 Working systems : automatic The brand of control modules : datakom Fuel systems : diesel Delivery terms :exw, fca, fob istanbul or cif Warranty : international 1 year spare part warranty Quality standard certificates : ce / iso 9001 / ohsas 18001 / iso 14001 / gost-r / tse All products tha Gentech alternators have been entirely manufacturing with turkish property products in gucbir factory in turkey Datakom control panels have been entirely manufacturing with turkish property products in turkey datakom facilities. We have productions of automatic, manuel, portable generators as optional Please contact us for our competitive export prices. L:225 cm W:95 cm H:160 cm Q:1150 kgs.
3 kVA Generator Sets Motor Brand : Perkins Alternator Brand : Mecc Alte Stand by :33 kVA Prime :30 kVA Cylinder Numbers : 33 kVA ( 3 Cylinders ) Rpm : 1500 rpm. ENGINE FEATURES •Diesel engine types suitable for heavy duty •4 stroke engine,water cooled •Mechanic/Electronic governor systems •Direct injection fuel system •Replacable cylinder jackets •12/24 Volt DC •Replacable oil filter,fuel filter and dry type air filter •Cooling radiator and fan •Flexible fuel hoses and oil outlet valve •Industrial muffler and flexible expansion compensator •Starter battery (lead acid) including wire and mount •Jacket water heater (for automatic models) ALTERNATOR FEATURES •Gentech brand,made in Turkey •Brushless,mono bearing,4 polar •Isolation class H •Protection class IP 21/22/23 •Self-alarm and regulated •Electronic automatic voltage regulator •2/3 stator windings to prevent harmonic failures •Windings are imprengiated with tropic epoxy resin against oil and acid CONTROL PANEL FEATURES •The control panel of monitoring,operation and safety is mounted on generator chassis •The features of automatic control panel : •Components on the panel •DKG 307 control module to monitor complete system •Static battery charger •Emergency stop button a) The features of generator control module DKG 307/DKG 309 •Automatic generator protection and control functions •Remote control function •Analaog displays for temperature and oil pressure •CosØ and KW displays for Generator •Engine operation time-clock •Maintenance time-clock •165 programmable parameters •Battery operated real-time clock •Weekly operating timer •Daily,weekly,monthly test •Fault recorder (with date and time info) •Statistical counters •Monitoring and recording at pc via RS-232 serial data port b) Displays on LCD monitor •Generator Volt (F-N) •Generator Ampere (L1,L2,L3) •Generator Frequency (Hz) •Generator CosØ •Generator Active Power (KW) •Oil Pressure (bar) •Cooling Water Temperature (0C) •Maintenance Timer •Network Volt (F-F/F-N) •Operating time display •Battery Voltage c) Alarms on LCD monitor •Overload/Over voltage •Over speed •Low/High network voltage •Low/High Generator Frequency •Cooling Water Level •Battery Alternator or Belt Breakage •Engine Low Oil Pressure •High Engine Temperature •Low Battery Voltage •Charge Failure L:220 cm W:95 cm H:180cm Q:1550 kgs.
55 kVA Generator Sets Motor Brand : Ricardo Alternator Brand : Gentech Cylinder Numbers : 55 kVA ( 4 Cylinders ) Rpm : 1500 Working Systems : Automatic The brand of Control Modules : Datakom Fuel Systems : Diesel Delivery Terms : FOB Istanbul or CIF Warranty : International 1 year spare part warranty Quality Standard Certificates : CE / ISO 9001 / OHSAS 18001 / ISO 14001 / Gost-R / TS All products that we manufacture are in the A class quality Gentech Alternators have been entirely manufacturing with Turkish property products in Gucbir factory in Turkey Datakom Control Panels have been entirely manufacturing with Turkish property products in Turkey Datakom facilities. We have productions of Automatic,Manuel,Portable Generators as optional Please contact us for our competitive export prices We can send the goods to all world countries as CIF delivery L:225cm W:95cm H:160cm Q:1150 kgs.
75 kva generator sets Motor brand : ricardo Alternator brand : gentech Cylinder numbers : 75 kva ( 4 cylinders ) Rpm : 1500 Working systems : automatic The brand of control modules : datakom Fuel systems : diesel Delivery terms : fob istanbul or cif Warranty : international 1 year spare part warranty Quality standard certificates : ce / iso 9001 / ohsas 18001 / iso 14001 / gost-r / tse All products that we manufacture are in the a class quality Gentech alternators have been entirely manufacturing with turkish property products in gucbir factory in turkey Datakom control panels have been entirely manufacturing with turkish property products in turkey datakom facilities. We have productions of automatic, manuel, portable generators as optional Please contact us for our competitive export prices. We can send the goods to all world countries as cif delivery L:225 cm W:95 cm H:160 cm Q:1150 kgs.
90 kVA Generator Sets Motor Brand : Ricardo Alternator Brand : Gentech Cylinder Numbers : 75 kVA ( 4 Cylinders ) Rpm : 1500 rpm. ENGINE FEATURES •Diesel engine types suitable for heavy duty •4 stroke engine,water cooled •Mechanic/Electronic governor systems •Direct injection fuel system •Replacable cylinder jackets •12/24 Volt DC •Replacable oil filter,fuel filter and dry type air filter •Cooling radiator and fan •Flexible fuel hoses and oil outlet valve •Industrial muffler and flexible expansion compensator •Starter battery (lead acid) including wire and mount •Jacket water heater (for automatic models) ALTERNATOR FEATURES •Gentech brand,made in Turkey •Brushless,mono bearing,4 polar •Isolation class H •Protection class IP 21/22/23 •Self-alarm and regulated •Electronic automatic voltage regulator •2/3 stator windings to prevent harmonic failures •Windings are imprengiated with tropic epoxy resin against oil and acid CONTROL PANEL FEATURES •The control panel of monitoring,operation and safety is mounted on generator chassis •The features of automatic control panel : •Components on the panel •DKG 307 control module to monitor complete system •Static battery charger •Emergency stop button a) The features of generator control module DKG 307/DKG 309 •Automatic generator protection and control functions •Remote control function •Analaog displays for temperature and oil pressure •CosØ and KW displays for Generator •Engine operation time-clock •Maintenance time-clock •165 programmable parameters •Battery operated real-time clock •Weekly operating timer •Daily,weekly,monthly test •Fault recorder (with date and time info) •Statistical counters •Monitoring and recording at pc via RS-232 serial data port b) Displays on LCD monitor •Generator Volt (F-N) •Generator Ampere (L1,L2,L3) •Generator Frequency (Hz) •Generator CosØ •Generator Active Power (KW) •Oil Pressure (bar) •Cooling Water Temperature (0C) •Maintenance Timer •Network Volt (F-F/F-N) •Operating time display •Battery Voltage c) Alarms on LCD monitor •Overload/Over voltage •Over speed •Low/High network voltage •Low/High Generator Frequency •Cooling Water Level •Battery Alternator or Belt Breakage •Engine Low Oil Pressure •High Engine Temperature •Low Battery Voltage •Charge Failure L:260 cm W:95 cm H:165 cm Q:1400 kgs.
Standby 40 kVA Prime 36 kVA Rpm. 1500 Engine Model : R4105D Number of Cylinders: 4 Dimensions without Canopy ( WxHxL ) cm : 95 x 170 x 140 Dimensions including Canopy ( WxHxL ) cm: 95 x 245 x 160 Weight without Canopy kg. : 650 Maximum Fuel Consumption at Full Power: 6,6 Lt./Sa Fuel Tank Capacity: 130 Lt. Intake System: Natural Engine oil capacity Lt.. : 6 Engine water capacity Lt. : 12.
Standby 50 kVA Prime 45 kVA Rpm. 1500 Engine Model : R4105D Number of Cylinders: 4 Dimensions without Canopy ( WxHxL ) cm : 95 x 180 x 145 Dimensions including Canopy ( WxHxL ) cm: 95 x 245 x 160 Weight without Canopy kg. : 900 Maximum Fuel Consumption at Full Power: 8,1 Lt./Sa Fuel Tank Capacity: 140 Lt. Intake System: Turbo Charge Engine oil capacity Lt.. : 13 Engine water capacity Lt. : 16.
Standby 75 kVA Prime 68 kVA Rpm. 1500 Engine Model : R4105ZD Number of Cylinders: 4 Dimensions without Canopy ( WxHxL ) cm : 95 x 190 x 145 Dimensions including Canopy ( WxHxL ) cm: 95 x 245 x 160 Weight without Canopy kg. : 1200 Maximum Fuel Consumption at Full Power: 12,4 Lt./Sa Fuel Tank Capacity: 150 Lt. Intake System: Turbo Charge Engine oil capacity Lt.. : 13 Engine water capacity Lt. : 16.
Standby 90 kVA Prime 81 kVA Rpm. 1500 Engine Model : R4105IZLD Number of Cylinders: 4 Dimensions without Canopy ( WxHxL ) cm : 95 x 190 x 145 Dimensions including Canopy ( WxHxL ) cm: 95 x 245 x 160 Weight without Canopy kg. : 1400 Maximum Fuel Consumption at Full Power: 15,6 Lt./Sa Fuel Tank Capacity: 150 Lt. Intake System: Turbo Charge, Intercooler, Aftercooler Engine oil capacity Lt.. : 16 Engine water capacity Lt. : 25.
Place of Origin - Turkey and Germany Brand Name - LOTUS Model Number - LOTUS-GEN LOTUS-GAS Usage - SVC Phase - Three Phase Protection - IP20 / IP55 / IP65 Frequency - 50Hz/60Hz Power factor - 0.8/0.9/1/Customized Color - Black or RAL7035 or Customized Rated power - 10KVA - 4000KVA
Diesel and Gasoline Generator Systems from 13 kVA to 2200 kVA Get contact for more details
JCBENERGY engine  JCBENERGY alternator Soundproof  50 / 60 HZ 127 / 220V, 230 / 400V, 277 /480V jcbenergy GENERATOR MANUFACTURER
EAP 88 Engine: PERKINS Engine Model : 1104A-44TG2 Stand By kVA: 88 Stand By kW : 70,4 Prime kVA: 80 Prime kW : 64 Rated Current : 115,2 Engine - PERK�°NS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat�¶r - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine PERK�°NS Engine Model 1104A-44TG2 Number of Cylinders 4 Inline Injection System Direct Compression Ratio 17.25 : 1 Bore 105 Strok 127 Displacement Lt 4,4 Air Intake Turbocharged - Air to Air Cooled Speed (RPM) 1500 Oil Capacity Lt 8 Standby Power kw / Hp 88 / 120 Prime Power Hp 80 / 110 Fuel Type Euro Diesel Governor System Mechanical Cooling System Water Cooling Coolant Capacity Lt 13 Fuel Consumption (lt / h) Lt Full Load 18,5 Lt %75 LOAD 14,2 Lt %50 LOAD 9,8 Frequency Hz Power kVA 93 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation �±1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 1350 Weight (Open) Kg 1160 Width (Silent) Mm 1000 Length (Silent) Mm 2800 Height (Silent) Mm 1500 Fuel Tank Capacity Lt 210 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAP 70 Engine: PERKINS Engine Model : 1104A-44TG1 Stand By kVA: 70 Stand By kW : 56 Prime kVA: 64 Prime kW : 51 Rated Current : 92 Engine - PERKINS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat�¶r - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine PERK�°NS Engine Model 1104A-44TG1 Number of Cylinders 4 Inline Injection System Direct Compression Ratio 17.25 : 1 Bore 105 Strok 127 Displacement Lt 4,4 Air Intake Turbocharged - Air to Air Cooled Speed (RPM) 1500 Oil Capacity Lt 8 Standby Power kw / Hp 65,6 / 88,5 Prime Power Hp 59,6 / 80,5 Fuel Type Euro Diesel Governor System Mechanical Cooling System Water Cooling Coolant Capacity Lt 13 Fuel Consumption (lt / h) Lt Full Load 14,6 Lt %75 LOAD 11 Lt %50 LOAD 8 Frequency Hz Power kVA 79 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation �±1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 1280 Weight (Open) Kg 1100 Width (Silent) Mm 1000 Length (Silent) Mm 2400 Height (Silent) Mm 1500 Fuel Tank Capacity Lt 180 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAP 66 Engine: PERKINS Engine Model : 1103A-33TG2 Stand By kVA: 66 Stand By kW : 52,8 Prime kVA: 60 Prime kW : 48 Rated Current : 86,4 Engine - PERKINS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat�¶r - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine PERK�°NS Engine Model 1103A-33TG2 Number of Cylinders 3 Inline Injection System Direct Compression Ratio 17.25 : 1 Bore 105 Strok 127 Displacement Lt 3,3 Air Intake Turbocharged - Air to Air Cooled Speed (RPM) 1500 Oil Capacity Lt 8 Standby Power kw / Hp 60,5 / 82 Prime Power Hp 55 / 74 Fuel Type Euro Diesel Governor System Mechanical Cooling System Water Cooling Coolant Capacity Lt 10,2 Fuel Consumption (lt / h) Lt Full Load 14 Lt %75 LOAD 10,4 Lt %50 LOAD 7,2 Frequency Hz Power kVA 66 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation �±1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 1200 Weight (Open) Kg 1030 Width (Silent) Mm 1000 Length (Silent) Mm 2400 Height (Silent) Mm 1500 Fuel Tank Capacity Lt 180 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAP 22 Engine: PERKINS Engine Model : 404A-22G1 Stand By kVA: 22 Stand By kW : 17,6 Prime kVA: 20 Prime kW : 16 Rated Current : 28,8 Engine - PERK�°NS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat�¶r - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine PERKINS Engine Model 404A-22G1 Number of Cylinders 4 Inline Injection System Direct Compression Ratio 23.3:1 Bore 84 Strok 100 Displacement Lt 2,21 Air Intake Naturally Aspirated Speed (RPM) 1500 Oil Capacity Lt 10,6 Standby Power kw / Hp 20,6 / 27,8 Prime Power Hp 18,7 / 25,2 Fuel Type Euro Diesel Governor System Mechanical Cooling System Water Cooling Coolant Capacity Lt 14 Fuel Consumption (lt / h) Lt Full Load 5,3 Lt %75 LOAD 4 Lt %50 LOAD 2,9 Frequency Hz Power kVA 22 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation ±1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 720 Weight (Open) Kg 590 Width (Silent) Mm 950 Length (Silent) Mm 2000 Height (Silent) Mm 1200 Fuel Tank Capacity Lt 125 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 1000 Engine: CUMMINS Engine Model : KTA38-G2A Stand By kVA: 1000 Stand By kW : 800 Prime kVA: 909 Prime kW : 727 Rated Current : 1308 Engine - CUMMINS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat�¶r - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine CUMM�°NS Engine Model KTA38-G2A Number of Cylinders 12 - V TYPE Injection System Direct Compression Ratio 14.5:1 Bore 159 Strok 159 Displacement Lt 38 Air Intake Turbocharged, Aftercooled Speed (RPM) 1500 Oil Capacity Lt 135 Standby Power kw / Hp 895 / 1199 Prime Power Hp 813 / 1089 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity Lt 350 Fuel Consumption (lt / h) Lt Full Load 202,3 Lt %75 LOAD 153,7 Lt %50 LOAD 103,1 Frequency Hz Power kVA 825 Voltage V 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation �±1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 9350 Weight (Open) Kg 8200 Width (Silent) Mm 2200 Length (Silent) Mm 6200 Height (Silent) Mm 2800 Fuel Tank Capacity Lt 1750 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 890 Engine: CUMMINS Engine Model : KTA38-G2B Stand By kVA: 890 Stand By kW : 712 Prime kVA: 809 Prime kW : 647 Rated Current : 1165 Engine - CUMMINS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternator - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine CUMM�°NS Engine Model KTA38-G2B Number of Cylinders 12 - V TYPE Injection System Direct Compression Ratio 14.5:1 Bore 159 Strok 159 Displacement Lt 38 Air Intake Turbocharged, Aftercooled Speed (RPM) 1500 Oil Capacity Lt 135 Standby Power kw / Hp 789 / 1057 Prime Power Hp 711 / 953 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity Lt 350 Fuel Consumption (lt / h) Lt Full Load 176,9 Lt %75 LOAD 133,3 Lt %50 LOAD 91,3 Frequency Hz Power kVA 825 Voltage V 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation ±1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 9300 Weight (Open) Kg 8150 Width (Silent) Mm 2200 Length (Silent) Mm 6200 Height (Silent) Mm 2800 Fuel Tank Capacity Lt 1750 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 825 Engine: CUMM�°NS Engine Model : KTA38-G2 Stand By kVA: 825 Stand By kW : 660 Prime kVA: 750 Prime kW : 600 Rated Current : 1080 Engine - CUMMINS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat�¶r - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine CUMM�°NS Engine Model KTA38-G2 Number of Cylinders 12 - V TYPE Injection System Direct Compression Ratio 14.5:1 Bore 159 Strok 159 Displacement Lt 38 Air Intake Turbocharged, Aftercooled Speed (RPM) 1500 Oil Capacity Lt 135 Standby Power kw / Hp 731 / 980 Prime Power Hp 664 / 890 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity Lt 350 Fuel Consumption (lt / h) Lt Full Load 167 Lt %75 LOAD 128 Lt %50 LOAD 90 Frequency Hz Power kVA 825 Voltage V 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation ±1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 9250 Weight (Open) Kg 8100 Width (Silent) Mm 2200 Length (Silent) Mm 6200 Height (Silent) Mm 2800 Fuel Tank Capacity Lt 1750 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnot permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 790 Engine: CUMMINS Engine Model : KTA38-G1 Stand By kVA: 790 Stand By kW : 632 Prime kVA: 718 Prime kW : 574 Rated Current : 1033 Engine - CUMM�°NS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat�¶r - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine CUMM�°NS Engine Model KTA38-G1 Number of Cylinders 12 - V TYPE Injection System Direct Compression Ratio 14.5:1 Bore 159 Strok 159 Displacement Lt 19 Air Intake Turbocharged, Aftercooled Speed (RPM) 1500 Oil Capacity Lt 135 Standby Power kw / Hp 701 / 953 Prime Power Hp 634 / 862 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity Lt 350 Fuel Consumption (lt / h) Lt Full Load 158 Lt %75 LOAD 122 Lt %50 LOAD 86 Frequency Hz Power kVA 550 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation �±1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 9200 Weight (Open) Kg 8050 Width (Silent) Mm 2200 Length (Silent) Mm 6200 Height (Silent) Mm 2800 Fuel Tank Capacity Lt 1750 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.