Lichtquelle: QS Nd: YAG solid-state laser Wellenlängen: 1064nm, 532nm Pulsenergie: von 200 bis 1000j (einstellbar) Pulsweite: bis 10ns Wiederholungsrate: wahlweise 1, 2, 3, 4, 5 ,6Hz Kühlung: Internes Wasser- und LuftKühlungsystem Größe: 48cm x 24cm x 24cm Nettogewicht: 10kg Leistungsanforderung: AC 220V±10% , 3A , 50Hz .
The goal of developing CM series laser equipments is to fully exert the machine's motion control capability and to further improve the processing quality. The ternet of serving for the field processing is emphasized on every aspects, whatever the software designing, mechanical structure,electrical performance or the selection of accessories. Quality management system has been fully executed in the prduction.Three major indicators of stability, precision and speed can represent the first class in the world. We keep improving CM series,and it has become the best carrier of laser processing--a new method in the industrial field. Laser power:30-150W Cutting thickness:0ú¡25mm(determined by materials) Engraving speed:0-64000(mm/min) Cutting speed:0-36000(mm/min) Winimum shaping character:Chinese character 2x2mm,Letter 1x1mm Resolution ration:í_ 4000 dpi Power supply:AC220Ví+ 10% ,50Hz Location procision:
Wavelength 980 nm Laser Output Power Up To 150~200 Watts Output Modes Continuous And Pulsed Length Of Pulses/Intervals 0.01-60s Transmission System 600ª¦m/800ª¦m/1000ª¦m Side-fire Fiber With SMA 905 Connector Avaliable,No Limit Aiming Beam 635nm ¿C 2mW Control Mode True Color Touch Screen Voltage/Current Rating 110V/220V, 50/60 Hz Dimensions 562(W)*420(L)* 267(H)mm Weight
It is 2 channel device which is useful for all behavioural and concentration related issues 1 unit, 700gms, 9 inch by 5 inch
1.Min order: one set 2.Certification: EN ISO 13485:2003 and MDD 93/42 EEC certificated by MEDCERT in Germany. 3. Competitive Price The prices of them are only 2/3 compared with the wholesale prices of the similar products. 4. After Sale Service Policy Would the products be broken in under warranty (not artificially), round-trip fare of the freight charge and insurance and all other costs of the defective goods are borne by our company. 5. Main Markets Europe and Middle East countries. 6. Main Markets Europe and Middle East countries. 7. Application - Endovenous Laser Treatment (EVLT) - ENT - Hemorrhoidectomy - Vaginal Rejuvenation - PLDD - Neurosurgery - Urology - Neoplasm. 8.Contact: Belinda Song. Dimensions 410(W)*330(L)*205(H) mm. Weight
Major indications: 1.Herniated disk, arthritis, chronic soft tissue pain 2.Cerebral thrombosis, cerebral infarction, stroke in rehabilitation period, coronary heart disease (chd), peripheral arterial occlusive disease (paod) 3.Infectious disease, varicella and herpes zoster, recurrent female genital herpes, bacterial vaginosis / mycotic vaginitis, trichomonas vaginitis, dermatosis with mycotic infection 4.Such peripheral chronic ulcers as burns, post radiation treatment wound, diabetic gangrene, bedsores 5.Assistant in tumor radiation treatment or chemo-treatment 6.Others: neurodermitis, hyperlipemia í=technical advantages 1.Ozone generated by corona-discharge with non-glass media 2.Wide range of ozone concentration selection, totally reaching the international demand of safety and efficiency for clinical application (3 - 80 µg/ml) 3.Built-in concentration correction ensuring a deviation ín 5%, 21ípc, which guarantees both safety and efficiency in clinical application 4.Remaining o3 converts back into o2 (done within 10s) by a built-in decontamination system, avoiding environment pollution 5.Power on self-check finished in 2s, complete sound/light alarm with operation guide, auto-power off protection program 6.No warm-up, only 6s after power-on for ozone generation of the default concentration 7.Simple icon-driven penal design for easy operation Mobile therapy center with integrated infusion stand and oxygen bottle, dimensions: 350 x 280 x 730 mm, weight 25 kg - ozone concentration: 0 - 99 µg/ml automatic calibrated - electrical data: 220 - 240v, 50 - 60 cycles, 250 va, protection class i, type b - ce certified: ce0368
We make equipment for hydrotherapy (whirl pool water massage tubs, jet shower cabins, hydromassage units), heat therapy (mud and fango paraffin heaters/warmers), kinesitherapy (massage couches, tables etc, body-sculpting powered exercise beds), medical furniture (diagnostic couches, screens, trolleys, gynaecology and urology chairs, commode chairs), ICU relative equipment (meden 2000) and many others. Palletised, boxed
Model: GREENLASER-04 Material: hard aluminum exterior surface treatment: black anode sclerosis switch: a rat tail + tactical point touch a switch battery: CR123 wavelengths: 532 nm Power :20-25 mW range:> 1,500 m start-up time: í_ 3seconds voltage: DC3.7V best temperature: 0 íµ ~ +35 íµ spot diameter: 6 M í_ ª¦10 mm 350g
Detail: Model:3-9í-32E Magnify ication:3-9í- OBJ LENSDIA(MM): 32 FIELD OF VIEW:7.5-2.5 WEIGHT(G):312 LENGTH (MM):300 EXT PUPIL(MM):90-67 EXT PUPIL DIA(MM):10.7-3.6 CLICK VALUE(MM):7 In bulk
Detail: The diameter: íí40mm Dot size: íí8 m.O.A* Length: íí5.8 inches Weight: íí6.8ounces Magnification: íínone(1x) Eye reliefú¦ ííunlimited Fielg of view: íí70 feet at 100 yards(optimum) Click adjustment: íí0.75 m.O.A* Power: íí2032 3v lithium *m.O.A. Stands for minute of angle 1m.O.A. Covers 1 inch at 100 yards In bulk
Parameters: Model: ML-LB2 Laser type: Q-Switched Nd: YAG Laser Laser wavelength: 1064&532nm Pulse energy: 0-800mj 0-300mj Width of Pulse(pulse duration): 0-10ns Repetition rate (pulse rate): 1, 2, 3, 4, 5, 6 (adjustable 0.5-3)Hz Light spot: 1-7mm Power supply: 220V, 6A or 110V, 12A With indicator laser light Net Weight: 9kgs; Size: 35cm*25cm*22cm Gross Weight: 16kgs Size: 50cm*35cm*30cm 1SET
Brief introduction: Equal light distribution High intensity Quiet, no noise of a fan 5 tube fluorescent lights Stand, : for the functional placement we offer a stand on castors Integral timer attached to count total hours of usage Height adjustable Technical specification: Electrical requirement : 220v+10%/50+2% Power supply : 120va Wave length (blue light): 425nm~ 275nm Light output: 500µ w/cm² Scope of light tube: 200mm Angle of light tube: 0º~90º Time accuracy: 2h+1min Integral time range: 0h~999h 59min Operation condition: Environment temperature: 18¦~30¦ Environment relative humidity: 10%~85%rh Atmosphere pressure: 700~1060hpa Package Gross weight : 45kg net weight: 25kg Measurement920*740*350mm
Brief introduction: Simultaneously air temperature and set temperature display. Alarm functions for safety includes Power failure fan failure Over temperature temperature deviation Temperature probe failure >37 pc temperature setting. A keypad locks helps to prevent inadvertent changes to settings. Trough for pulling and pushing add the water and wash is convenient. Heater is electrically cut off if air /skin temperature inside incubator exceed 40fpc. Humidity is adjustable. The infant bed inclination angle is adjustable. Gross weight : Control cabinet: 120kg hood cabinet: 30kg Net weight: Control cabinet: 90kg hood cabinet: 10kg Measurement 1200*700*960mm
Microprocessor based servo controlled temperature system. The microprocessor-controlled unit allows for three settings, pre-warm, manual or automatic. Alarms functions for safety includes: Power failure temperature deviation Temperature probe failure over temperature Convenient x-ray cassette under infant bed. Three variable mattress tilts. Separate white lamp allows convenient observation. Adopts anti-explosion micro crystal quartz infrared radiation tube for its radiation source . Having quick heating and long life span. Digital display to indicate temperature. Have independent the second heat cuts off , the system is more safe. Protection when temperature probe in over temperature. Gross weight : 100kg net weight: 70kg Measurement: 1100*700*960mm
Brief introduction: Equal light distribution. High intensity. Quiet, no noise of a fan. 5 tube fluorescent lights. Stand, : for the functional placement we offer a stand on castors. Integral timer attached to count total hours of usage. Height adjustable. Gross weight : 45kg net weight: 25kg Measurement·ª920*740*350mm
Brief introduction: Simultaneously air temperature and set temperature display. Alarm functions for safety includes Power failure fan failure Over temperature temperature deviation Temperature probe failure >37pc temperature setting. A keypad locks helps to prevent inadvertent changes to settings. Trough for pulling and pushing add the water and wash is convenient. Heater is electrically cut off if air /skin temperature inside incubator exceed 40pc. Humidity is adjustable. The infant bed inclination angle is adjustable. Technical specification: Electrical requirement : 220v+10%/50+2% Power supply : _420va Air temperature control range 2538 Temperature fluctuation: _0.5 Uniformity of mattress temperature: _0.8 Warm-up time: _45min Internal noise level: _55db Operation condition: Environment temperature: 2538 Environment relative humidity: 30%~75%rh Environment air velocity of flow:
Brief introduction: Microprocessor based servo controlled temperature system. The microprocessor-controlled unit allows for three settings, pre-warm, manual or automatic. Alarms functions for safety includes: Power failure temperature deviation Temperature probe failure over temperature Convenient x-ray cassette under infant bed. Three variable mattress tilts. Separate white lamp allows convenient observation. Adopts anti-explosion micro crystal quartz infrared radiation tube for its radiation source . Having quick heating and long life span. Digital display to indicate temperature. Have independent the second heat cuts off , the system is more safe. Protection when temperature probe in over temperature. Technical specification: Electrical requirement : 220v+10%/50+2% Power supply : _1500va Temperature control range: 32~38.5 Temperature probe accuracy: _0.3 Mattress temperature uniformity: _2.0 Warm-up time: _45min Adjustable horizon angle of radiator: +90 Operation condition: Environment temperature: 18~30 Environment relative humidity: 30%~75%rh Environment air velocity of flow:
This system is IPL(intense pulse light) +RF(Radio Frequency), which is the best technology in the market. For this system, you can use IPL only or RF only, or IPL+RF together. System Characteristic: 1.handle cooling system: User may adjust the cooling system to improve the treatment result affected by the constant cooling temperature. 2.the handpiece has fast plug in-out. Water and electricity body cut, automatic diagnosis system insetted. Easy and fast to use. 3.built-in expert system: join the clinical experience we accumulated for several years into the expert system to make sure the system is safe and simple to use. 4.you can upgrade this system through computer. 5.customer design Certification Received: CE Mark Treatment range Almost all the skin problem, such as speck, age spot, pigmentation, wrinkle removal, skin rejuvenation, hair removal, sunburn, rough pores and acne removal. Special features 1. Effective shallower hair removal 2. Independent of skin types 3. A more effective technique for skin rejuvenation as the technology allows for sufficient thermal damage of the target area without overheating surrounding tissue structures. Treatment theory The objective of effective permanent hair reduction and skin rejuvenation is to heat up and injure the target, be it a hair follicle or a vascular or pigmented lesion. The job of the intense pulsed light is to heat up the target to the required temperature and thereby lowering the impedance of the target. The RF current then travels along the path of least impedance (preheated path of the intense light) and gently heats up everything in its pathway. This results in further injury to the target and completes the heating (injury) that is necessary for the desired biologic effect, for example to stop hair growing, or for vascular and pigmented lesions to fade. RF f½s effect is pertaining to the electric density which depends on the impedance. And it is not absorbed by melanin and thus independent of skin types. So it is an optimum resolution for the patient of darker skin or of the shallower hair. Specifications: Light source: intense pulse light IPL Energy Out: 0-40J/cm2 IPL Pulse Repetition Rate 0.5Hz RF Energy Out: 0-100J/cm3 Dimensions: 460mmf-500mmf-900mm Weight: 65kg, portable is 38kg around Input Voltage: 230Vf+, 50Hz Operating Panel: 8.4f+f+ TFT Color touch Screen Cooling: 0-5 centigrade Handpieces: SR, HR, VR, AR
System Characteristic: 1.handle cooling system: User may adjust the cooling system to improve the treatment result affected by the constant cooling temperature. 2.the handpiece has fast plug in-out. Water and electricity body cut, automatic diagnosis system insetted. Easy and fast to use. 3.built-in expert system: join the clinical experience we accumulated for several years into the expert system to make sure the system is safe and simple to use. 4.you can upgrade this system through computer. 5.customer design Certification Received: CE Mark Treatment range Almost all the skin problem, such as speck, age spot, pigmentation, wrinkle removal, skin rejuvenation, hair removal, sunburn, rough pores and acne removal. Special features 1. Effective shallower hair removal 2. Independent of skin types 3. A more effective technique for skin rejuvenation as the technology allows for sufficient thermal damage of the target area without overheating surrounding tissue structures. Treatment theory The objective of effective permanent hair reduction and skin rejuvenation is to heat up and injure the target, be it a hair follicle or a vascular or pigmented lesion. The job of the intense pulsed light is to heat up the target to the required temperature and thereby lowering the impedance of the target. The RF current then travels along the path of least impedance (preheated path of the intense light) and gently heats up everything in its pathway. This results in further injury to the target and completes the heating (injury) that is necessary for the desired biologic effect, for example to stop hair growing, or for vascular and pigmented lesions to fade. RF is effect is pertaining to the electric density which depends on the impedance. And it is not absorbed by melanin and thus independent of skin types. So it is an optimum resolution for the patient of darker skin or of the shallower hair. Specifications: Light source: intense pulse light IPL Energy Out: 0-35J/cm2 IPL Pulse Repetition Rate 0.5Hz RF Energy Out: 0-100J/cm3 Weight: 8kg around Input Voltage: 230Vf+, 50Hz Operating Panel:TFT Color touch Screen Cooling: 0-5 centigrade Handpieces: SR, HR, VR, AR
B. Braun offers a holistic infusion therapy concept which combines high-quality products with intelligent technologies and services