Brief introduction:
Microprocessor based servo controlled temperature system.
The microprocessor-controlled unit allows for three settings, pre-warm, manual or automatic.
Alarms functions for safety includes:
Power failure temperature deviation
Temperature probe failure over temperature
Convenient x-ray cassette under infant bed.
Three variable mattress tilts.
Separate white lamp allows convenient observation.
Adopts anti-explosion micro crystal quartz infrared radiation tube for its radiation source . Having quick heating and long life span.
Digital display to indicate temperature.
Have independent the second heat cuts off , the system is more safe.
Protection when temperature probe in over temperature.
Technical specification:
Electrical requirement : 220v+10%/50+2%
Power supply : _1500va
Temperature control range: 32~38.5
Temperature probe accuracy: _0.3
Mattress temperature uniformity: _2.0
Warm-up time: _45min
Adjustable horizon angle of radiator: +90
Operation condition:
Environment temperature: 18~30
Environment relative humidity: 30%~75%rh
Environment air velocity of flow: <0.3m/s
Package·ª
Gross weight : 100kg net weight: 70kg
Measurement: 1100*700*960mm
Microprocessor based servo controlled temperature system. The microprocessor-controlled unit allows for three settings, pre-warm, manual or automatic. Alarms functions for safety includes: Power failure temperature deviation Temperature probe failure over temperature Convenient x-ray cassette under infant bed. Three variable mattress tilts. Separate white lamp allows convenient observation. Adopts anti-explosion micro crystal quartz infrared radiation tube for its radiation source . Having quick heating and long life span. Digital display to indicate temperature. Have independent the second heat cuts off , the system is more safe. Protection when temperature probe in over temperature. Gross weight : 100kg net weight: 70kg Measurement: 1100*700*960mm
Infant Radiant Warmer
Easy to Use Focused Heating Air Control Mode Manual Mode Servo Controlled Mode Skin temperature displayed in 1 bright LED display Two modes of warming i.e. Skin, Air & Manual Heater o/p in 10 equal steps in percentage Programmable Heater power & time in Manual Mode Individual LED for selection for mode (Skin, Air & Manual) Made In India
Brief introduction: Equal light distribution High intensity Quiet, no noise of a fan 5 tube fluorescent lights Stand, : for the functional placement we offer a stand on castors Integral timer attached to count total hours of usage Height adjustable Technical specification: Electrical requirement : 220v+10%/50+2% Power supply : 120va Wave length (blue light): 425nm~ 275nm Light output: 500µ w/cm² Scope of light tube: 200mm Angle of light tube: 0º~90º Time accuracy: 2h+1min Integral time range: 0h~999h 59min Operation condition: Environment temperature: 18¦~30¦ Environment relative humidity: 10%~85%rh Atmosphere pressure: 700~1060hpa Package Gross weight : 45kg net weight: 25kg Measurement920*740*350mm
Brief introduction: Simultaneously air temperature and set temperature display. Alarm functions for safety includes Power failure fan failure Over temperature temperature deviation Temperature probe failure >37 pc temperature setting. A keypad locks helps to prevent inadvertent changes to settings. Trough for pulling and pushing add the water and wash is convenient. Heater is electrically cut off if air /skin temperature inside incubator exceed 40fpc. Humidity is adjustable. The infant bed inclination angle is adjustable. Gross weight : Control cabinet: 120kg hood cabinet: 30kg Net weight: Control cabinet: 90kg hood cabinet: 10kg Measurement 1200*700*960mm
Brief introduction: Equal light distribution. High intensity. Quiet, no noise of a fan. 5 tube fluorescent lights. Stand, : for the functional placement we offer a stand on castors. Integral timer attached to count total hours of usage. Height adjustable. Gross weight : 45kg net weight: 25kg Measurement·ª920*740*350mm
Brief introduction: Simultaneously air temperature and set temperature display. Alarm functions for safety includes Power failure fan failure Over temperature temperature deviation Temperature probe failure >37pc temperature setting. A keypad locks helps to prevent inadvertent changes to settings. Trough for pulling and pushing add the water and wash is convenient. Heater is electrically cut off if air /skin temperature inside incubator exceed 40pc. Humidity is adjustable. The infant bed inclination angle is adjustable. Technical specification: Electrical requirement : 220v+10%/50+2% Power supply : _420va Air temperature control range 2538 Temperature fluctuation: _0.5 Uniformity of mattress temperature: _0.8 Warm-up time: _45min Internal noise level: _55db Operation condition: Environment temperature: 2538 Environment relative humidity: 30%~75%rh Environment air velocity of flow:
Supplier: Infant incubator, infant warmer, photo-therapy unit
Supplier: Medical instrument and equipment like infant warmers