Brief introduction:
Equal light distribution.
High intensity.
Quiet, no noise of a fan.
5 tube fluorescent lights.
Stand, : for the functional placement we offer a stand on castors.
Integral timer attached to count total hours of usage.
Height adjustable.
Gross weight : 45kg net weight: 25kg
Measurement·ª920*740*350mm
Brief introduction: Equal light distribution High intensity Quiet, no noise of a fan 5 tube fluorescent lights Stand, : for the functional placement we offer a stand on castors Integral timer attached to count total hours of usage Height adjustable Technical specification: Electrical requirement : 220v+10%/50+2% Power supply : 120va Wave length (blue light): 425nm~ 275nm Light output: 500µ w/cm² Scope of light tube: 200mm Angle of light tube: 0º~90º Time accuracy: 2h+1min Integral time range: 0h~999h 59min Operation condition: Environment temperature: 18¦~30¦ Environment relative humidity: 10%~85%rh Atmosphere pressure: 700~1060hpa Package Gross weight : 45kg net weight: 25kg Measurement920*740*350mm
LED based Phototherapy Unit for infants. Cure for Jaundice in newborn babies.
Brief introduction: Simultaneously air temperature and set temperature display. Alarm functions for safety includes Power failure fan failure Over temperature temperature deviation Temperature probe failure >37 pc temperature setting. A keypad locks helps to prevent inadvertent changes to settings. Trough for pulling and pushing add the water and wash is convenient. Heater is electrically cut off if air /skin temperature inside incubator exceed 40fpc. Humidity is adjustable. The infant bed inclination angle is adjustable. Gross weight : Control cabinet: 120kg hood cabinet: 30kg Net weight: Control cabinet: 90kg hood cabinet: 10kg Measurement 1200*700*960mm
Microprocessor based servo controlled temperature system. The microprocessor-controlled unit allows for three settings, pre-warm, manual or automatic. Alarms functions for safety includes: Power failure temperature deviation Temperature probe failure over temperature Convenient x-ray cassette under infant bed. Three variable mattress tilts. Separate white lamp allows convenient observation. Adopts anti-explosion micro crystal quartz infrared radiation tube for its radiation source . Having quick heating and long life span. Digital display to indicate temperature. Have independent the second heat cuts off , the system is more safe. Protection when temperature probe in over temperature. Gross weight : 100kg net weight: 70kg Measurement: 1100*700*960mm
Brief introduction: Simultaneously air temperature and set temperature display. Alarm functions for safety includes Power failure fan failure Over temperature temperature deviation Temperature probe failure >37pc temperature setting. A keypad locks helps to prevent inadvertent changes to settings. Trough for pulling and pushing add the water and wash is convenient. Heater is electrically cut off if air /skin temperature inside incubator exceed 40pc. Humidity is adjustable. The infant bed inclination angle is adjustable. Technical specification: Electrical requirement : 220v+10%/50+2% Power supply : _420va Air temperature control range 2538 Temperature fluctuation: _0.5 Uniformity of mattress temperature: _0.8 Warm-up time: _45min Internal noise level: _55db Operation condition: Environment temperature: 2538 Environment relative humidity: 30%~75%rh Environment air velocity of flow:
Brief introduction: Microprocessor based servo controlled temperature system. The microprocessor-controlled unit allows for three settings, pre-warm, manual or automatic. Alarms functions for safety includes: Power failure temperature deviation Temperature probe failure over temperature Convenient x-ray cassette under infant bed. Three variable mattress tilts. Separate white lamp allows convenient observation. Adopts anti-explosion micro crystal quartz infrared radiation tube for its radiation source . Having quick heating and long life span. Digital display to indicate temperature. Have independent the second heat cuts off , the system is more safe. Protection when temperature probe in over temperature. Technical specification: Electrical requirement : 220v+10%/50+2% Power supply : _1500va Temperature control range: 32~38.5 Temperature probe accuracy: _0.3 Mattress temperature uniformity: _2.0 Warm-up time: _45min Adjustable horizon angle of radiator: +90 Operation condition: Environment temperature: 18~30 Environment relative humidity: 30%~75%rh Environment air velocity of flow:
Supplier: Infant incubator, infant warmer, photo-therapy unit
Ultrasound therapy unit Description Ultrasound therapy 1 and 3 Mhz clinical use Digital with LCD Deluxe Model Metallic Body Manarti 1 and 3mhz frequency Pulsed and continuous therapy operation 10%, 20%, 50% and 100%veriable duty cycle output of 16hz, 48hz, or 100hz. Clinical protocols, the most appropriate application and parameter set for the patientâ??s condition. light weight designs for clinic, hospital and home visits. auto detection of ultrasound applicator. micro controller-based design for optimum accuracy. Soft touch buttons. timer 0-30 minute put power is up to 2. 5 watts / cm2, which is controlled digitally back light LCD display
It is 2 channel device which is useful for all behavioural and concentration related issues 1 unit, 700gms, 9 inch by 5 inch