Specifications: 1- Pressure range: 0 ¡V 100kg/cm2„XNumber of stations: Three. (All for Long And Short Term) 2- Pressure Accuracy: Electromagnetic, hydro pneumatic pump(mercury make) keeps the accumulator charged at desired pressure, which in turn will ensure the smooth flow of static pressure. 3- Pressure input: Compressed air up to 7 kg/cm2 4- Pressure out put: Through hydro pneumatic pump. Ratio 1:25 5- Pressure control & Time Control: Three nos. of Digital pressure Controller Range 0.00 to 99.99 Bar. & Timer Range up to 999.9/9999 hours. 6- Failure detection: Through three nos. of Time totalizes. 7- Power requirement: 230 Volts 50HZ. 8- Paints: Powder coating. 9- RS 232 interface with WINDOW based software to conduct test and keep record of data with graph in PC. Standard.
Specifications: 1- Microprocessor based Controller with range up to 1000 deg C and Accuracy of ± 1 deg C. 2- Silica quartz combustion tube and boat. 3- Heating load of 2kv. 4- Ceramic furnace with nichrome heating element. 5- Paint: Powder Coated. 6- Power: 230V AC. Standard.
Tetracycline residue rapid test device. 40 pcs/kit.
Detection of e. Coli o157 article qualitative detection of colloidal gold feces, food, water and other samples of e. Coli o157. The degree of color is proportional to the sample bacteria. Enrichment effect well. Can be used to treat samples in rapid screening, positive samples can be isolated bacteria, reduce the workload. Steps: 1. Will be placed on the detection of clean, dry working platform. 2. Provided with the kit with clean straw or from the pipette to take samples or enrichment sample 2 drops, drops added to the test sample by adding end section (detection section white side), start timing; 3. 2-15 minutes of observation, 15 minutes after the results do not count. [Results judge] negative: a red line appears, which appears in the control line position of a red line; positive: two red lines appear, that in the test line and control line positions are there red line; invalid: no red line appears that the test line and control line in the position not appear red. [Treatment of samples to be tested] 1. Direct detection: direct detection of water will be. 2. By bacteria detection (1) stool samples: the samples of the inoculated immediately take 1 gram of 9ml of mec broth, 37 constant temperature shaking culture 6h. (2) food samples: the 25 g samples of ground, and immediately inoculated in 225ml of mec broth, 37 constant temperature shaking culture 9h. (3) water samples: water samples will be 400ml immediately inoculated in 5 times concentrated mec 100ml in broth, 37 constant temperature shaking culture 16-20h. 3. Proposed use of enrichment broth was added 20mg / l novobiocin the ec modified broth. [Interpretation of the results] 1. Enrichment after negative results may be judged as negative. 2. Or by direct detection of bacteria have positive results, the pathogen can be isolated. 3. Negative result does not have a precise meaning. [storage] 4-30 , cool dark dry place.
Intended use: Toxoplasma igg/igm rapid test is a rapid immunochromatographic test for the simultaneous detection of igm and igg antibodies to toxoplasma gondii in human serum/plasma. The test can be used as a screening test for toxoplasma infection and as an aid for differential diagnosis of the self limiting primary toxoplasma infections and the potentially fatal secondary toxoplasma infections in conjunction with other criteria. Test principle: The toxoplasma igg/igm rapid test is a lateral flow chromatographic immunoassay. The test cassette consists of: 1) a burgundy colored conjugate pad containing toxoplasma recombinant envelope antigens conjugated with colloid gold (toxoplasma conjugates) and rabbit igg-gold conjugates, 2) a nitrocellulose membrane strip containing two test bands (t1 and t2 bands) and a control band (c band). The t1 band is pre-coated with the antibody for the detection of igm anti-toxoplasma, t2 band is coated with antibody for the detection of igg anti-toxoplasma, and the c band is pre-coated with goat anti rabbit igg. Absence of any t bands (t1 and t2) suggests a negative result. The test contains an internal control (c band) which should exhibit a burgundy colored band of the immunocomplex of goat anti rabbit igg/rabbit igg-gold conjugate regardless of the color development on any of the t bands. Otherwise, the test result is invalid and the specimen must be retested with another device. Reagents and materials supplied: 1. Test cassette individually foil pouched with a desiccant. 2. Plastic dropper 3. Buffer 4. Package insert. Storage and stability: The kit must be stored at 2-30 c. Warning and precautions: 1. For in vitro diagnostic use only. Not for medicinal use. 2. Do not use beyond expiry date. 3. Read the instructions careful y before performing the test. 4. Handle all specimen as potential y infectious. 5. Follow standard biosafety guidelines for handling and disposal of potential y infective material.
1. Intended use: The salbutamol residue rapid test card is a rapid, one step test for the qualitative detection of salbutamol in meat samples. The whole time of assay is only approx. 15~25min. 2. Summary: Salbutamol belongs to the group of G-agonists. It can promote animalí»s fat metabollism, and accelerate the growth of animal. However, this is prohibitted. Except for its lipolytic and anabolic effect, salbutamol is used as antiasthmatic and tocolytic agent which has a slacken effect on non-striated musculature. It can remain in animalí»s body and may lead to strong effect to human. If for worse, it may threaten peopleí»s life. Salbutamol is prohibitted for using in most countries. The salbutamol residue rapid test card is a rapid test to qualitatively detect the presence of salbutamol in specimen at the sensitivity of 58g/kg. The major advantage of the one step test device is that the result can be observed easily . 3. Principle: The principle is the antigen-antibody reaction. The one step test device is a competitive immunoassay of which the detector reagent consists colloidal gold particles that is coated with affinity purified anti-salbutamol antibodies. The capture reagent in the assay is salbutamol-protein conjugate, which is immobilised on the membrane of the test device. The specimen migrates over the membrane. The more analyte in the sample, the more effectively it will compete with the salbutamol immobilised on the membrane for binding to the limited amount of antibodies of the detector reagent.. If salbutamol in the specimen is above 58g/kg, it will prevent the binding of the detector reagent with the salbutamol immobilised on the membrane, resulting in positive.
Uses: It is used when liquid heating is needed in industry, agriculture, health and medicine, scientific research and college labs etc. Characteristics: 1. Enclosed big size Ceramic Hot Plate with characteristics of flame protection and durability. 2. Heating and stirring can proceed simultaneously. 3. Heating power and stirring speed is stepless adjusted. The Digital type has the more function as follows: a.Can control the srirring clockwise and anticlockwise b.With two sensors can show different setting number c.Can show the setting temperature,hot plate surface temperature,setting speed and actual speed at the same time. d.Can show the setting temperature,tested liquid temperature,setting speed and actual speed at the same time 300, 190, 126 400, 240, 220.
Tensile testing machine.
PC-controlled and Windows-based operation interface Easily connected to a printer or other exterior devices via USB port 7'' touch screen display, full-color alphanumeric-capable graphical user interface(GUI) Visualized real time speed graphic display A virtually unlimited number of user-defined recipe programs Stainless steel coating bowl (optional polyethylene coating bowl) Optional auto-dispensing and nitrogen purge Rigid mechanical design protects the coating solutions from contact of drive system Leading resolution and repeatability standard of this industry Free technical support for the life of product via phone, e-mail, and fax. Technical specifications: Size: 19 inch X 14 inch X 11 inch Machine Weight: 19.0Kg Power: 110/220 VAC, 50/60 Hz, 1 Amp Vacuum: More than 2.1 CFM 40 process recipe programs on board Spin speed: 0 to 5, 000 RPM Spin resolution: 1RPM Spin repeatability: 1RPM 1s resolution for step time(Max. Step time 9, 999s) Spin speed acceleration: 0 to 30, 000 RPM/s unloaded Substrate sizes: 10 mm to 200 mm round.
DipMaster 50 DIP Coater is a specially designed tool for performing the feasibility study of research & development in thin films and coatings from the experts in the DIP coating technology. It is compact and light for easy setup in the laboratory: Fume hoods, glove boxes, magnetic stirrer, laminar airflow benches, etc. To be convenient to conduct experiment. The maintenance-free feature comes from its ruggedness and simple design. The coater can be easily configured into a system to do a single solution coating or multiple solution coatings by the combination of the coater with the solution management modules. Programmable microcomputer controlled: Immersion speed, submersion period, withdrawal speed Touch screen interface Multi-mode dipping Vibration free immersion and withdrawal Easy to use, affordable, desk-top Compact: Easily configured with a glove box Equipped with a magnetic substrate holder Customized substrate holder for irregular substrates. Least maintenance CE certified Voltage: 110V/8A, 220V/4A Dimension: 15 cm x 30 cm x 35 cm Net Weight: 5Kg Withdrawal Speed: 8mm-200mm/minute Withdrawal Distance: Up to 75mm Substrate size: Up to 50mm X 50mm Four different dipping modes Dipping time: 0-999s.
The class II Biological Safety Cabinet is an opean front,ventilated cabinet.The Class II biological safety cabinet will provide personnel,environment and product protection. Front Window: Front window consists two-layer toughened glass>5mm,Motorized control. Work Zone: Work zone interior is made of 304 stainless steel. Front Panel: Superstructure is constructed from expoxy coated cold rolled steel for long life. VFD Display: Compared with LED,LCD,it demonstrates various colors with high bright,even in the evening.It shall work no less than 30,000 hours continually. UV Lamp: Interlocked and activated to work when blower and fluerescent lamp are offf and front window is closed. Foot Switch: Use foot switch to adjust the height of the front window. Front airflow intake grid: Aerodynamically designed front airflow intake gird; Eliminates potential turbulence and contamination. Waterproof Socket: 2 waterproof sockets are located in the side panel,for optimum convenience of using small devices inside the cabinet. Advantage: 1. Remote control. The operator need not to contact the biological safety cabinet directly,it¡¯s favorable for preventing cross contamination. It also makes the control operation much easier and convenient. 2. Foot Switch. Within the range of the activity, we could use foot switch to adjust the height of the front window. It is our unique design. 3. Work area surrounded by negative pressure. 4. Timer function 5. VFD display 6. Filter & UV life inquiry 7. Safety power lock Model: Parameter : 603588 Internal size(mm): 600,400,580 External size(mm) :700,500,1200 Tested Opening :200 mm Working Opening :400 mm Inflow Velocity :0.53 m/s DownFlow Velocity :0.33 m/s Filter : Two HEPA filter 99.999% efficient(0.3 microns) Blower : 1 Front Window : Two-layer toughened glass >5mm Noise: 65 dB UV lamp : 15W,1 Fluorescent Lamp : 40W,1 Lighting (Lux) : 680 Power(W) : 800 Water and Gas Tap : 0 Waterproof Socket : 2 Display : LED display Control System: Microprocessor Airflow System : 70% air recirculation,30% air exhaust Material: Work zone interior is made of 304 stainless steel, Body: Epoxy coated cold rolled steel Base (optional) Height: 635mm Caster Wheel: Universal Wheel Clean Level : 100 Electrical Parameter : 110~240V/50~60Hz (optional) Net weight(kg) : 80 Gross weight(kg) : 110 Package (mm): 950,850,1430 Standard Configuration: Body, Remote control, Foot switch, UV lamp and Fluorescent Lamp Optional Accessory : Armrest, Air curtain tester, Formalin fumigation sterilizer, Ammonium hydrogen carbonate neutralizer.
Advantages: Due to lock piece does not leak, Breakage less due to furnace Culture tube is machine made and proper heat is given. Rota flow is available in all sizes and in all types of packing. Culture tube is available in 100 pc packing.
number,Name ,Quantity,instructions 1,Double layer reactor 20L,one,GG17Borosilicate glass 2,Stirring motor,one,Speed 0-780rpm 3,Frequency control,one,No classless ajustable speed £¬digital speed display(digital display temp) 4,Five mouth kettle,one,Euipped with the reactor body£¬condensor(backflow and condensor)¡¢feeding funnel, Thermometer tube,valve for lower the temp,stirring mouth;and can equip the solid charging port according to the customer needs 5,PTFE sealing,One set,Supply high vacuum environment 6,Frame of the reactor,one,Support the reactor,304 7,condensor,one,Condensation and distillation(backflow) 8,PTFE discharging valve,one,Can be discharged 9,Thermometer tube,one,For contain the thermometer 10,Feeding funnel,one,For dropping of the liquid 11,PTFE stirring rod,one,PTFE,with the liner stainless steel 12,Distillation and condensation pipe,one,Use to connect the kettle cover and condensor,separation,concentration 13,Release valve,one,Use to release air and fill the nitrogen 14,Vacuum table,one,Measuring the vacuum degree of the reactor 15,Bracket of the reaction body and cover,one,Aluminum alloy 16,Tray of the kettle body,one,Aluminum alloy 17,Hex wrench ,one,Adjust the frame 18,Universal joint,one,one. wooden cases or carton
CHEMAT Technology, Inc. Has designed and manufactured a compact and easy-to-use spin-coater, Model KW-4A, for precise and uniform deposition of thin films and coatings. Its rugged, vibration-free and portable design makes it a versatile tool for your research facility. A two-stage spin process allows dispensing at low speeds and homogenizing the coating at high speed. The KW-4A spin coater can be used to deposit metal oxide thin films, polymer coating and organic thin films. 2-Stage Spinning Stage 1: 500-2, 500 rpm 2-18 Seconds Stage 2: 1, 000-8, 000 rpm 3-60 Seconds. Power 115 VAC, 60 Hz, 1 Amp 220 VAC, 50 Hz, 1 Amp Vacuum: > 2.1 CFM Speed Stability:
CHEMAT TECHNOLOGY, INC. Has designed and manufactured a compact and easy-to-use hotplate, Model KW-4AH, for baking and curing thin films and coatings. Its rugged, portable design, and temperature uniformity make it a versatile tool for research facilities. In conjunction with KW-4A spin coater, KW-4AH hotplate can be used to fabricate metal oxide thin films, polymer coatings and metal organic thin films. Operation: Manual Load Process Control: Program (For details see OMRAN operation manual) Temperature fluctuation: 1C Temperature uniformity: 3% Temperature Range: ¡ª30C - 350C (KW-4AH-350) ¡ª30C - 600C (KW-4AH-600) Substrate Size: ¡ª7.5 inch X 7.5 inch(KW-4AH-350) ¡ª5.8 inch X 5.8 inch(KW-4AH-600) Inert gas purge (KW-4AH-600 only).
UV curing is a photochemical process by which monomers undergo curing (polymerization or cross inking) upon exposure to ultraviolet radiation. A specially formulated monomer will polymerize when exposed to ultraviolet radiation. This UV "curable" monomer includes a sensitizer which absorbs UV energy and initiates a polymerizing reaction in the monomer. KW-4AUV is specially designed for curing photosensitive coatings and thin films. It equips two UV light sources with radiations at 365 nm and 245 nm. The coated substrates up to 6?in diameter will be rotated at 6 rpm to ensure uniform curing. The built-in interlock door to prevent the exposure of UV radiation gives safe operation. In conjunction with the KW-4A spin coater, the system can be used to make various coatings and thin films via the photochemical process.
Specifications : Wavelength range : 190-1100nm Spectral Bandwidth : 2nm (5nm, 4nm, 1nm Optional) Wavelength Accuracy : ± 0.3 nm Wavelength Reproducibility : 0.15 nm Photometric System : Double beam, auto scan , Dual detectors Photometric Accuracy : ± 0.3% T (0-100%T), ± 0.002A(0~1A) Photometric Reproducibility : 0.15%T Working mode : T, A, C, E Photometric Range : -0.3, -3.5A Stray Light : 0.1%T (Nal, 220nm, NaNO2 340 nm) Baseline Flatness : ±0.002A Stability : 0.001A/h (at 500nm, after warming up) Noise : ±0.001A (at 500nm, after warming up ) Display : 6 inches high light blue LCD Detector : Silicon photodiode Power : AC:220V/50Hz, 110V/60Hz, 180W Dimensions : 630X470X210mm Weight : 26Kg.
SPECIFICATIONS: Wavelength Range: 190-900nm Wavelength Accuracy: ±0.25nm Resolution: Two Spectral lines of Mn at 279.5nm and 279.8nm can be separated with the spectral bandwidth of 0.2nm and valley-peak energy ratio less than 30% Baseline Stability: Background correction: The D2 lamp background correction capability at 1A is better than 30 times. !0.004A/30min. Light Source: Lamp turrel: 6-lamp turret RIC-114/ RIC-113 4-lamp turret RIC-112 Auto-alignment, fully automated scan and peak-picking Lamp current adjustment: Automatic adjustment and display. Wide pulse current: 0~25mA Narrow pulse current: 0~10mA Lamp power supply mode: 400Hz square wave pulse 100Hz Narrow square wave pulse + 400HzWide Square wave pulse (RIC-114/ RIC-113) Optical System: Monochromator: Single beam, Czurney-turner design grating monochromator Grating: 1800l/mm Focal length: 277mm Blazed wavelength: 250nm Spectral bandwidth: 0.1nm, 0.2nm, 0.4nm, 1.2nm automatic change Flame Atomizer: Burner: 10cm single slot all-titanium burner Spray chamber: Corrosion resistant all-plastic spray chamber Nebulizer: High efficiency glass nebulizer with metal sleeve, sucking up rate:6-7mL/min Detection and Data Processing System: Detector: R928 photomultiplier with high sensitivity and wide spectral range Software:Windows Operating System Analytical method:Window curve auto-fitting; standard addition method; automatic sensitivity correction, automatic calculation of concentration and content. Repeat times: Maximum 20 times of repeat measurement, automatic calculation of mean value, standard deviation and relative standard deviation Multi-task function: Sequential measurement of multi-elements in one sample Condition reading:With model function Result printing: Measurement data and final analytical report printout, editing with excel. Standard RS-232 serial port communication Characteristic Concentration and Detection Limit: Normal Air-C H flame: Cu Characteristic concentration Rich oxygen Air-C H flame: Ba: Characteristic concentration Function Expansion: Hydride vapor generator can be connected for hydride analysis. Dimensions and weight: 1020 (L) X 490 (W) X 540 (H) mm (main unit), unpacked 80 Kg. Dimensions and weight: 1020 (L) X 490 (W) X 540 (H) mm (main unit), unpacked 80 Kg.
Origin:Zhejiang China Specification:11.6*32mm Volumn:1.5ml Material:USP 1 expansion 30 Parkage:100pcs Delivery time:within 7 days Prompt delivery OEM:accepted Certification:ISO 9001 Packing:sealed/outer:carton/special ordering requirement accepted. Packing: sealed/outer:carton/special order accepted Weight: 0.6kg/pack(100pcs).
Metering mode: Double-beam C-t optical structure, blazed holographic grating, photomultiplier tube detection Wavelength range:190nm-1100nm Resolution:better than 0.15nm Spectro bandwidth:1.8nm Wavelength accuracy:0.3nm(with automatic wavelength calibration device.) Wavelength accuracy: