Lc 250 is a water displacing anti corrosion compound Used to prevent rust on metal surfaces with unlimited Applications in the fields of marine, automobile, aviation Farming, etc. Lc 250 creeps along surfaces and into cracks to Lubricate, loosen frozen parts and displace water. The Loosened rust can easily be removed. The displacing Mechanism works by preferential wetting. The attraction, Of the preventative that of water, thus displacing water. Application Apply lc 250 to metal surfaces either by brushing or dipping. When dipping is used, allow excess chemical to drip prior to Storage. Handling & precaution Avoid unnecessary skin contact. Prolonged contact may cause Irritation. Packaging Available in pail of 20 lt.. Can also be custom packaged.
Kb 236 is a special blend of mineral acids, Corrosion inhibitors, emulsifiers & dispersing Agents. Effectively removes rust, scale and soil From metal and other hard surfaces. Application May be sprayed or brushed on surfaces. Clean surface free from Rust, soil and dirt. Apply kb 236. Allow to stand for 5 - 15 minutes, Then wipe off or flush with water. Dry surface can be repainted if Desired for longer protection. Dosage For cleaning surfaces, dilute one part of kb 236 with up to 10 Parts of water depending on the thickness of scales, soil & dirt. Allow to stand. Brushing may be required. Flush with water until all Scale are removed Handling & precaution Acidic product. Irritating to eyes and skin. After contact with skin Wash immediately with plenty of water. In case of eye contact Irrigate thoroughly with water for at least 15 minutes. Seek medical Advice Packaging Available in pail of 20 lt.. Can also be custom packaged.
Remove impurities in the form of carbon from the surface of the oven, cooking utensils, sewer, ventilation, and other places where carbon deposition thickness is usually attached.
Lc 106 is an ideal steam line anti corrosion treatment for Boilers. It is a highly concentrated, alkaline product. Eliminates corrosion in the outgoing steam lines and Stabilizes ph in the condensate. Application For use with boilers which requires anti-corrosion treatment in the steam lines. It Disperses with steam and forms a protection film on the inner surfaces of the Steam pipes. Injected directly into the boiler by means of a proportioning pump. It is environmentally safe. Do not use in boilers where steam Contacts food. Dosage Initial : 1 quarts per 100 gallons or 1 : 400 Maintenance: 1 quart for every 200 gallons of make-up water or 1 : 800 Maintain ph of 7.5 – 8.5 in the steam line of system. Maintain sulfite of 30 – 60 Ppm along with lc 106. Maintain the conductivity less than 5000 mho/cm. Handling & precaution Lc 106 is an alkaline product and should be handled with care to prevent Personal injury. Wear protective clothing and eye protection. In case of contact With skin, immediately flush with water. In case of contact with eye, flush with Water for 15 minutes and obtain immediate medical attention. Triple rinse used Cans before reuse or disposal. Packaging Available in pail of 20 lt.. Can also be custom packaged.
Lc 121 is specially formulated for large installations and High hardness water. It is developed for effective, Economical cooling tower treatment at hospitals, hotels, Large apartment houses, office buildings and other Industrial and institutional cooling installations. Also Recommended for a small installations with high Hardness make-up water. It contains no phosphates, Chromate, zinc or other chemicals that cause pollution Problem. Helps control mineral deposits, sludge and Surface pitting and does not stain automobiles or Buildings. Application Use a reliable automatic proportioner with timer for controlled dosage. Directly inject in to the circulating pipe upstream from the condenser. Cycles Of concentration will vary from 5 – 20 as a probable upper limit. For higher Limits consult our laboratory. Dosage Initial treatment : add 1 gallon of lc 121 per 2, 000 gallons of re-circulating Water. Maintenance treatment : 1 gallon per 6, 000 gallons of water lost to Bleed off. Handling & precaution Wear protective clothing and eye protection should be worn. In case of skin Contact, immediately flush thoroughly with plenty of clean water. In case of Eye contact, flush with copious of amounts of water for 15 minutes and Obtain immediate medical attention. Refer to msds for more specific Directions. Packaging Available in pail of 20 lt.. Can also be custom packaged
Lc 126 condenser water treatment does not use sodium Chromate, zinc or other toxic chemicals in its composition. It Eliminates the serious pollution problems usually associated With the use of such chemicals for corrosion and scale Control in cooling system. It protects medium size cooling Towers against scale, sludge and corrosion. Lc 126 Contains a special anti-foulant additive to reduce Accumulations of mud and silt in condenser tubes. Ideal for Average towers with 75 to 500 ton capacity. Application Formulated for use in open re-circulating cooling water systems found in air Conditioning and process operations. Apply manually, directly to the cooling Tower basin. Dosage Initial dosage : add 1 gallon of lc 126 for every 500 gallons of system Capacity. Maintenance dosage : add 1 gallon of lc 126 for every 1, 000 gallons of System water lost to bleed off from the cooling tower system Handling & precaution Slightly alkaline aqueous solution. Keep out of reach of children. Refer to Material safety data sheet for more specific procedures and directions. Packaging Available in pail of 20 lt.. Can also be custom packaged.
Lc 141 is single product treatment designed to prevent Scale deposits and corrosion to ferrous and non-ferrous Surfaces in hot water heating systems and chilled closed Loops. It passivates the surfaces and forms a barrier layer to Inhibit corrosion. It is a synergistic combination of Phosphonates, polymers and phosphate. Application Easily feed/injected directly into the system by means of a chemical by Pass feeder. Dosage Initial treatment is 1 gallon per 1, 000 gallons of water in the system. There After add lc 141 to maintain a level of 25-35 ppm (mg/l) of Orthophosphate. Handling & precaution It is highly alkaline and should be handled with care to prevent personal Injury. Protective clothing and eye protection should be provided and worn. In case of skin contact , immediately flush thoroughly with plenty of clean Water. In case of eye contact, flush with copious amounts of water for 15 Minutes and obtain immediate medical attention. Packaging Available in pail of 20 lt.. Can also be custom packaged.
Lc 143 is specially formulated for use in systems that are Constantly exposed to air, such as vented air to pressurized Systems providing corrosion protection even in systems that Are not tight. It reduces maintenance costs by keeping Exchangers, air handling units and zone valves free of Corrosion clogs. It also reduces corrosion insulation and System damage. Lc 143 contains boron nitrate that protects Against oxygen and acid attack, works well in any closed System. Recommended for any hot water boiler or recirculating Or closed loop system. Application Can be added to a system either manually or with a pot feeder. If the Treatment dosage is less that the capacity of feeder, fill up the feeder with Tap water to prevent air on treatment. Not to be used in electric Steam boilers. Dosage For chilled water circulating system : for initial or maintenance treatment, Add 1 gallon of lc 143 for each 200 gallons of chilled water. The treatment Level is easily tested with the drop titration nitrite test kit. Handling & precaution Irritant. Avoid contact with eyes. Avoid repeated or prolonged contact with Skin. If contact occurs, flush with water. If eye contact occurs, flush with Water for 15 minutes. Seek medical attention. Keep out of reach of Children. Refer to material safety data sheet for more specific procedures. Packaging Available in pail of 20 lt.. Can also be custom packaged.
Lc 144 is formulated to prevent and reduce scale, Rust, corrosion and sludge in generator system. It is The most effective coolant for generator and other High temperature systems. Lc 144 is a special blend Of selective glycols, anti-corrosion additives and Sludge conditioners that provide smooth running of The systems. Application Lc 144 is widely used in power plants, generator system, etc... Found in Marines, aviations, industries, automotives, industries, hospitals, etc. Benefits ? excellent protection ? no more severe Damages ? non-flammable ? non-polluting ? non-corrosive ? non-toxic ? completely safe to Use ? reduces costly Maintenance Dosages 1. Check incoming water source for total hardness and chloride. 2. Recommended total hardness below 30 ppm and chloride below 50 Ppm. 3. Lc 144 can be diluted at a ratio of 1:1, 1:5, 1;10, 1:32 with deionised Water (recommended). 4. Repeat application monthly or quarterly depending on application. Flush if colour changes or becomes cloudy. Handling & precaution For professional use only. To be used in well ventilated environment. In Case of contact with eyes, rinse thoroughly with water and seek medical Advice immediately. If swallowed, take plenty of water and seek medical Advice immediately. Avoid prolonged contact with skin. Put on gloves for Sensitive skin. Keep out of reach of children. Additional information may Be obtained from material safety data sheet (msds). Packaging Available in pail of 20 lt.. Can also be custom packaged.
Lc 235 is designed specially for use in systems where The use of acidic descalers are not recommended. Lc 235 may be re-circulated by means of a high volume Pump for the removal of scale. Lc 235 can be used Safely on to copper & brass surfaces besides being very Effective in steel system. Application Lc 235 may be soaked overnight and re-circulated. When scale is present, The tubes should first scraped out to remove as much as possible and then Flushed out with a hose. Dosage Circulate a 10% solution (10 gallons of lc 235 for every 100 gallons of Water.) for a period of four to six hours depending on the scale thickness. Solution may be heated for effectiveness by steaming. The system should Then be drained and inspected. If more scale remains, repeat the process. When the cleaning process is complete, flush with clean water and place it Back in service. For storing / stand by system use lc 253 or lc 252. Handling & precaution This product is alkaline and should be handled with care to prevent personal Injury. Protective clothing, gloves and eye protection should be worn. In case Of skin contact, immediately flush thoroughly with plenty of clean water. In Case of eye contact, flush with copious amounts of water for 15 minutes and Consult a physician. Refer to material safety data sheet for more specific Procedures and directions. Packaging Available in pail of 20 lt.. Can also be custom packaged.
Lifting rust on surface of iron, metal, etc.
Provide a layer / coating that reject / hold water so it does not seep into the stone.
Lifechem lc 306 is a solvent based wet look coating for all types Of hard and porous surfaces including granite, marble & sand Stone. Lc 306 penetrates into the tiny pores of the surface Structure and the minute crevices helped by the selected Penetrants. The volatile solvents evaporates to leave an inert, Transparent residue that makes the wet look. The surface is Shining and polish-able, washable and ready after at least 48 Hours. Lc 306 is comprised of volatile hc solvents, penetrants And levelling agents designed to provide excellent penetration And wet look. Lc 306 is ideal for providing and inert coat on Porous materials like granite, marbles, tiles and such surfaces Including walls, floors, desks, fixtures, woodwork and even Paper & paper based products. Application Applied by spray, mop, brush wipe, dip after mixing the catalyst in proper Proportional. Leave a thick coating and let it dry for at least 48 hours. Re-apply For thicker coat. Available for coating floors, walls, desks, fixtures, wood work. Special use for granite, marble and porous tiled surfaces of various colours and Types. If there is excess localised deposition, then re-apply to remove and even The surface. Apply uniformly to avoid accumulation. Handling & precaution Avoid spills on eyes. Should avoid unnecessary contact with skin. Can irritate When exposed for a longer period. Harmful is swallowed. Do not inhale the Vapours for long period. Highly flammable, do not bring near naked Flame. Keep in cool place. Use in a well ventilated place/room. Packaging Available in pail of 20 lt.. Can also be custom packaged.
LC 100 ideal to remove not only calcium carbonate & calcium phosphate deposits but also calcium sulfate and barium sulfate as well.
LC 122 is an effective wide band micro-biocide designed for use in algae and bacteria control. It does not cause foaming and is not lost by evaporation from the system. It is a concentrated blend of organo-sulfur compounds, which should be added only after proper dilution by slug feeding. Application: Use to control algae and bacteria in re-circulating commercial and industrial water cooling towers. Prior to its use, systems be cleaned to remove algae growth, microbiological slime and other deposits. Dosage: Initial slug additions of LC 122 per 1,000 gallons of water should be employed every 1 - 5 days or as needed. The frequency of addition depends upon the relative amount of bleed-off and the severity of the microbiological problem. Slug additions should be made in the sump of the cooling tower. During very hot weather, greater frequency or higher dosage may be required to increase its effectiveness. Handling & Precaution: It is a very strong alkaline treatment and may cause eye damage and skin irritation. Do not get in eyes, skin or on clothing. Wear goggles or face shield and rubber gloves when handling. Avoid contamination of food. Harmful or fatal if swallowed. In case of skin contact wash with plenty of soap and water. Remove contaminated clothing and wash before reuse. If product gets in the eyes, flush immediately with copious amount of clean cool water for at least 15 minutes. If swallowed, call physician. Do not induce vomiting or give anything by mouth to an unconscious person. Packaging: Available in pail of 20 lt.. Can also be custom packaged.
LC 123 is specially formulated for large installations high hardness water. It is developed for effective, economical cooling water treatment at hospitals, hotels, large apartment houses, office buildings and other industrial and institutional cooling installations with high hardness make-up water. It contains no phosphates, chromate, zinc, or other chemicals that cause pollution problem. Helps control mineral deposits, sludge and surface pitting and does not stain automobiles or buildings. Application Use a reliable automatic proportioner with timer for controlled dosage. Follow instructions for calculated bleed of rate and recommended daily maintenance treatment as suggested by the Field Chemist Personnel. The dosage and treatment program depend on size of installation and water hardness (ppm). Dosage Initial treatment : Add 1 gallon of LC 123 per 2,000 gallons of recirculating water. Maintenance treatment as per size of installation & hardness (consult our Technician) Handling & Precaution Wear protective clothing and eye protection should be provided and worn. In case of skin contact, immediately flush thoroughly with plenty of clean water. In case of eye contact, flush with copious of amounts of water for 15 minutes and obtain immediate medical attention. Refer to MSDS for more specific directions. Packaging Available in pail of 20 lt.. Can also be custom packaged.
LC 124 is an effective chlorine based designed for use in algae and bacteria control. It does not cause foaming. It is a concentrated blend of organo-chloro compounds which should be added only by slug feeding. Application: Use to control algae and bacteria in re-circulating commercial and industrial water cooling towers. Prior to its use, it is advisable that systems be cleaned to remove slime and other deposits. Dosage: An initial slug addition of 1 gallon of LC 124 per 2,000 gallons of water should be employed every 1-4 days or as needed. The frequency of addition depends upon the relative amount of bleed-off and the severity of the microbiological problem. Slug additions should be made in the sump of the cooling tower. During very hot weather, greater frequency or higher dosage may be required to increase its effectiveness. Handling & Precaution: It is a very strong treatment and may cause eye damage, mucous attack and skin irritation. Do not inhale, get in eyes, skin or on clothing. Wear goggles or face shield and rubber gloves when handling. Avoid contamination of food. Harmful or fatal if swallowed. In case of skin contact, wash with plenty of soap and water. Remove contaminated clothing and wash before reuse. If product gets in the eyes, flush immediately with copious amount of clean cool water for at least 15 minutes. If swallowed, call physician. Do not induce vomiting or give anything by mouth to an unconscious person. Packaging: Available in pail of 20 lt.. Can also becustom packaged.
LC 255 is a versatile and highly effective rust preventative for use on unpainted metals during outdoor storage or overseas shipping. LC 255 protects metal with heavy waxy film. It does not require any surface cleaning or preparation and covers the metal like a paint, but easily removable. LC 255 provides protection for storage of metal, equipment, tools, tanks, structures, machinery, castings, fittings, valves, doors, frames, fixtures, jigs, etc. Application: LC 255 can be applied by spraying, brushing or dipping. It is recommended to apply by dipping in a tank with water draining facilities which ensures maximum coverage, penetration and cost effectiveness. LC 255 absorbs water and moisture while lubricating plated surfaces and bare metals such as steel, iron, alumunium, copper, brass and lead. Handling & Precaution: Avoid contact with eyes and skin. In the case of contact with eyes, wash immediately with plenty of water. Seek medical advice. If ingested, do not induce vomiting, seek medical attention. Packaging: Available in pail of 20 lt.. Can also be custom packaged.
KB 201 is a powerful porcelain cleaner for brightening & cleaning porcelain surfaces. It contains complexing agent, sequestering agent, scale remover, wetting agent and specialized blooming remover. It is a specialized product and requires careful application methods. WRONG & UNWANTED APPLICATIONS NOT PRESCRIBED, MAY CAUSE UNEXPECTED RESULTS & DAMAGE. Must be diluted before use. Never use on glazed surfaces. Application: Pour diluted KB 201 on the surface to be cleaned, allow it to react for 2 – 20 minutes, depending on the type of stain & dilution factor. After that, brush with soft brush then rinse thoroughly with clean water. Make small test spot to verify result before actual use. Dosage: Dilute with water depending on the cleaning work. Can be diluted up to 50 times or more. Handling & Precaution: Contains only organic acidic compounds. Do not ingest. Do not get in eyes, on skin or clothing. Keep the container closed when not in use. Avoid breathing the mists. Wear a mask when handling. Use sufficient ventilation to prevent build-up or mists. KEEP AWAY FROM CHILDREN. Packaging: Available in pail of 20 lt.. Can also be custom packaged.
KB 224 is a special water based polymer with silicone specially designed to protect and keep a shine & wet look on vinyl, rubber, plastic and leather or other such surface materials. KB 224 protect surfaces from fading and cracking by reducing ultraviolet light, while bringing out color, restoring luster and shine, protects against abrasion. Eliminates static electricity to reduce dirt attraction. If less shine is desired, lightly buff with damp cloth. Application: Apply KB 224 with a clean cloth or sponge ( or spray ) with a cleaning action. Spread evenly, allow to penetrate and chemically bond for a few minutes then remove excess for a beautiful protective shine. On some surfaces a two coat application provides best results. Apply as needed to maintain shine and protective coating. Dosage: Use undiluted product. Handling & Precaution: This product may caused slipperiness on certain surfaces until it is completely dry. May caused smearing on glass or other transparent services. Avoid spills on eyes. Should avoid prolonged unnecessary contact with skin. May irritate when exposed for a longer period on certain sensitive skin. Harmful if swallowed. Keep away from children. Keep container capped in a cool dry place Packaging: Available in pail of 20 lt.. Can also be custom packaged.