LC 100 ideal to remove not only calcium carbonate &
calcium phosphate deposits but also calcium sulfate
and barium sulfate as well.
LC 105 is an ideal one product boiler internal treatment. It can control not only calcium carbonate & calcium phosphate deposits but also calcium sulfate and barium sulfate. Highly concentrated alkaline product. Eliminates excessive precipitation of solids and reduces sludge accumulation. Application For use with make-up water with hardness below 150 ppm and effectively disperses iron oxides as well as calcium phosphate and clay. Injected directly into the boiler by means of a proportioning pump. It is environmentally safe, non-hazardous and non-corrosive. Dosage Initial : 2 quarts per 100 gallons or 1 : 200 Maintenance: 1 quart for every 100 gallons of make-up water or 1 : 400 Maintain 15-25 ppm (mg/l) of orthophosphate in the boiler waters with pH between 11.0 – 12.0. Maintain Conductivity below 5000 µmho/cm. Consult LifeChem Technical Services when Hardness is low or high. Handling & Precaution LC 105 is an alkaline product and should be handled with care to prevent personal injury. Wear protective clothing and eye protection. In case of contact with skin, immediately flush with water. In case of contact with eye, flush with water for 15 minutes and obtain immediate medical attention. Triple rinse used cans before reuse or disposal. Packaging Available in pail of 20 lt. Can also be custom packaged.
Lc 106 is an ideal steam line anti corrosion treatment for Boilers. It is a highly concentrated, alkaline product. Eliminates corrosion in the outgoing steam lines and Stabilizes ph in the condensate. Application For use with boilers which requires anti-corrosion treatment in the steam lines. It Disperses with steam and forms a protection film on the inner surfaces of the Steam pipes. Injected directly into the boiler by means of a proportioning pump. It is environmentally safe. Do not use in boilers where steam Contacts food. Dosage Initial : 1 quarts per 100 gallons or 1 : 400 Maintenance: 1 quart for every 200 gallons of make-up water or 1 : 800 Maintain ph of 7.5 – 8.5 in the steam line of system. Maintain sulfite of 30 – 60 Ppm along with lc 106. Maintain the conductivity less than 5000 mho/cm. Handling & precaution Lc 106 is an alkaline product and should be handled with care to prevent Personal injury. Wear protective clothing and eye protection. In case of contact With skin, immediately flush with water. In case of contact with eye, flush with Water for 15 minutes and obtain immediate medical attention. Triple rinse used Cans before reuse or disposal. Packaging Available in pail of 20 lt.. Can also be custom packaged.
Supplier: Solvent distillation plant , ethanol distillation plant , etp, water treatment plant , effluent treatment plant, evaporator , dryer, zld plant, lab equipment supplier, lab chemical supplier, industrial equipment , storage tank , bulk tank, petrochemical plant, ethyl acetate distillation plant, supplier of chemicals, reactor , pressure vessel , instruments, plc panel ,dcs panel, mcc panel , steam boiler, agitator tank, mixing tank, blending tank, bottling plant , vodka plant , ena distillation plant , fermentation plant , cooking plant, cpu plant, dg set, dpr report. etc, industrial dryer, industrial storage tanks, lab equipment, bio cng plant, biogas plant, bioreactor, sludge settling tank, wash settling tanks, pre fermenters, culture vessel, blender, blending tank, agitator, mixing tank, shell and tube heat exchanger, reboiler, reactor, mcc electrical panel, pressure vessel, evaporator, industrial dryer, beer plant, brewery plant, ethanol distillery , grain alcohol distiller plant
Supplier: Diesel oil en 590 10 ppm & other grades, food stuff, textiles, gloves, masks, waste management machineries & plants, metal scrap, chemicals, water treatment plants, sewage treatment plants, waste water treatment plants, filtration systems, waste to energy plants, msw, e waste, metal recycling, lithium ion recycling, plastic waste to energy, tyre recycling, bio gas, biodiesel, diesel blending plants, waste sludge recycling,, waste heat recovery boilers
Lc 143 is specially formulated for use in systems that are Constantly exposed to air, such as vented air to pressurized Systems providing corrosion protection even in systems that Are not tight. It reduces maintenance costs by keeping Exchangers, air handling units and zone valves free of Corrosion clogs. It also reduces corrosion insulation and System damage. Lc 143 contains boron nitrate that protects Against oxygen and acid attack, works well in any closed System. Recommended for any hot water boiler or recirculating Or closed loop system. Application Can be added to a system either manually or with a pot feeder. If the Treatment dosage is less that the capacity of feeder, fill up the feeder with Tap water to prevent air on treatment. Not to be used in electric Steam boilers. Dosage For chilled water circulating system : for initial or maintenance treatment, Add 1 gallon of lc 143 for each 200 gallons of chilled water. The treatment Level is easily tested with the drop titration nitrite test kit. Handling & precaution Irritant. Avoid contact with eyes. Avoid repeated or prolonged contact with Skin. If contact occurs, flush with water. If eye contact occurs, flush with Water for 15 minutes. Seek medical attention. Keep out of reach of Children. Refer to material safety data sheet for more specific procedures. Packaging Available in pail of 20 lt.. Can also be custom packaged.
LC 123 is specially formulated for large installations high hardness water. It is developed for effective, economical cooling water treatment at hospitals, hotels, large apartment houses, office buildings and other industrial and institutional cooling installations with high hardness make-up water. It contains no phosphates, chromate, zinc, or other chemicals that cause pollution problem. Helps control mineral deposits, sludge and surface pitting and does not stain automobiles or buildings. Application Use a reliable automatic proportioner with timer for controlled dosage. Follow instructions for calculated bleed of rate and recommended daily maintenance treatment as suggested by the Field Chemist Personnel. The dosage and treatment program depend on size of installation and water hardness (ppm). Dosage Initial treatment : Add 1 gallon of LC 123 per 2,000 gallons of recirculating water. Maintenance treatment as per size of installation & hardness (consult our Technician) Handling & Precaution Wear protective clothing and eye protection should be provided and worn. In case of skin contact, immediately flush thoroughly with plenty of clean water. In case of eye contact, flush with copious of amounts of water for 15 minutes and obtain immediate medical attention. Refer to MSDS for more specific directions. Packaging Available in pail of 20 lt.. Can also be custom packaged.
High Pressure Boiler Oxygen Scavengers Boiler Scale & Corrosion Inhibitor Sludge Conditioners Alkalinity Builders Boiler Phosphate Treatment Chemicals Steam Condensate Line Treatment Chemicals Fuel Additives & Anti-Foams Cooling Water Scale & Corrosion Inhibitors Cooling Water Biocides & Biodispersants Reverse Osmosis & Nano-Filteration Membrane Scale and Fouling Cleaners Reverse Osmosis Antiscalants & Antifoulants Reverse Osmosis Bicides Reverse Osmosis Corrosion Inhibitors Closed System Corrosion Inhibitors Closed System Biocides Descaling Chemicals
HEDP is an organophosphoric acid corrosion inhibitor It can chelate with Fe Cu and Zn ions to form stable chelating compounds It can dissolve the oxidized materials on these metals surfaces HEDP shows excellent scale and corrosion inhibition effects under temperatures of 250C HEDP has good chemical stability under high pH values is hard to hydrolyze and is hard to decompose under ordinary light and heat conditions Its acidalkali and chlo rine oxidation tolerance are better than that of other organophosphoric acids salt HEDP can react with metal ions in the water system to form a hexaelement chelating complex with calcium ions in particular Therefore HEDP has good antiscale and visible threshold effects When built together with other water treatment chemicals it shows good synergistic effects Application HEDP is used as scale and corrosion inhibition in circulating cool water system oil field and lowpressure boilers in fields such as electric power chemical industry metallurgy fertilizer etc In light woven industry HEDP is used as detergent for metal and nonmetal In dyeing industry HEDP is used as peroxide stabilizer and dyefixing agent In noncyanide electroplating HEDP is used as chelating agent The dosage of 110mgL is preferred as scale inhibitor 1050mgL as corrosion inhibitor and 10002000mgL as detergent Usually HEDP is used together with polycarboxylic acid
LC 104 is an ideal single product boiler internal treatment, specially formulated by blending sludge conditioner & oxygen scavenger for dual function in packaged boiler systems. It can control not only calcium carbonate & calcium phosphate deposits but also calcium sulfate and barium sulfate. Highly concentrated alkaline product. Eliminates excessive precipitation of solids and reduces sludge accumulation. The oxygen scavenger prevents pitting corrosion in the boiler system. It is environmentally safe, non-hazardous and non-corrosive. Application Used in packaged boilers below 5 Tons/Hr. For use with make-up water hardness below 150 ppm and effectively disperses iron oxides as well as calcium phosphate and clay. Injected directly into the boiler by means of a proportioning pump. Dosage Initial : 2 quarts per 100 gallons or 1 : 200 ratio Maintenance: 1 quart for every 100 gallons of make-up water or 1 : 400 ratio Maintain 15-25 ppm (mg/l) of orthophosphate in the boiler waters with pH between 11.0 – 12.0. Maintain Conductivity below 3000 µmho/cm. Consult LifeChem Technical Services when Hardness is low or high. Handling & Precaution LC 104 is an alkaline product and should be handled with care to prevent personal injury. Wear protective clothing and eye protection. In case of contact with skin, immediately flush with water. In case of contact with eye, flush with water for 15 minutes and obtain immediate medical attention. Triple rinse used cans before reuse or disposal. Refer to MSDS for detailed information. Packaging Available in pail of 20 lt.. Can also be custom packaged.