Scaleâ??s Operation : -Vibration -Drafts / Air currents -External Rubbing / friction -Moving the scale Functions: -CAL(calibration ) -MODE -TARE
The R5.0V1 Weighing Scale PCB are designed using advanced 16Bit Renesas microcontroller Our PCBS are manufactured using automatic pick & Place robotic machines, bring you world class standards in performance & reliability .Our controllers incorporates high-performance selectable digital filter algorithm for accuartes&stable measurement of weight reading . Features: -Piece count --Price Computing -Person / Coin Weighing -Peak Load Indicator -Set-Put Out-put / Control of relays -Yarn Weighing
Weighing Machine: Types : Four Load Cell System With C Channel Frame, Heavy Duty Range With Jumbo Load Cell, Light Duty Pl.Series, Display Size Point 8, Table Top Mini (metal Body) Display Size 0.5, Counter Scale (plastic Body), Jwellery Scale.
Dig. Wooden Weight Scale
Shape round ,square Color Black Temperature 40 deg c Packaging Type corrugated box Size 75mm to 500 mm
Xtreme Shop Floor CNC CMM for precision measurements in even the most extreme manufacturing environments coordinate measuring machine accuracy wherever you need it.
8 piece set - 4 measuring cups and 4 measuring spoons in graduated sizes. Excellent quality long lasting product. Designed for right- or left-hand use. Hand wash recommended, dishwasher safe.
Pt100 Elements -
.Thermocouple -
Differential Pressure Sensor -
.Differential Pressure Transmitter -
.pH Transmitter -
GP Systems has developed flow sensing and indicating system suitable for flow measurement of gases (corrosive or non corrosive), air, and liquids . We use reputed american sensors to ensure most accurate sensing of flow. The system is made in such a way to ensure long life and ease of use. It can measure the flow even a t low pressures and even if there is moisture in the gas/ air. Features: ï?· Most accurate system of flow measurement ï?· Selectable units like lpm, m 3 /min etc ï?· Optional relay output ï?· Optional retransmission function ï?· No effect of moisture or dust in pipeline System Specifications: Measurement Principle: Differential pressure Indicates: Flow Rate and Total Volume Working gas temperature: -25 to 125C Display: LCD/LED 4 digit flow rate, 10 digit total volume Line Pressure: 50mmWC to 300bar Orifice specifications: As per drawing Recording of parameters: Optional Accuracy of system: Better the 1% Communication interface: RS232/ RS485 (Optional) Line Size: From 4mm to 40 inches Power Supply: 220 V AC -
.Bio Gas And Producer Gas Flow Meter -
Key Features: 1.Very low pressure measurable without long-term drift 2.Rugged design 3.Maintenance free 4.Over-pressure protected Key Specifications: 1.Measuring range: 0 ~ 25 Pa to 0 ~ 1000 Pa 2.Maximum static operating pressure: 1.0 bar 3.Maximum safe pressure: 1.7 bar 4.Straight line error (max.): 1.0 % Full scale 5.Pressure connection: screw clamp connectors (aluminum) for 6/4 mm or 8/6 tube 6.Repeatability: 0.1 % full scale 7.Operating ambient & media temperature: -10° C to +70° C 8.Protection class: IP65 per DIN EN 60529 9.Linearity: < 2% Full scale 10.Electrical output: 4-20mA linear, 2 â?? wire 11.Power supply: 24 V DC 12.Material, housing: Polyamide PA 6,6 13.Materials, media contact: Silicon, PVC, aluminum, brass Application areas: 1.Filter status / condition monitoring 2.Precision air duct measurement 3.Clean room pressure balance monitoring 4.Burner air feed low pressure detection 5.Oven air feed control Industrial areas: 1.Air conditioning and ventilation systems 2.Auditorium, office, conference rooms 3.HVAC and ventilation application 4.Environment monitoring 5.Clean room and laboratory rooms
Key Features: 1.Measurement range 0 ?? 1 bar 2.Static operating pressure 25 bar 3.Diaphragm and sealing of Viton 4.Operating voltage 24 V DC/AC 5.Output signal 4-20 mA square rooted 6. 3 ½-digit LED display 7.ECCN: N AL: N 8.Robust design with high repeatability 9.Over pressure protection 10.Wear free non-contact LVDT sensing element, thus no maintenance 11.Signal output with possibility of various characteristic curve 12.Characteristic conversion of output via3?¦.30 entries table 13.Complete set-up of all parameters and print out by using optional PC programming interface EU03 Applications areas: 1.Volume flow monitoring of lubricants oil, mill oil 2.Gearbox lubricant flow monitoring 3.Flow measurement ?? lubricants, oil, hydrocarbons, water, gases Industrial areas: 1.Cement plants 2.Nuclear plants, coal or gas fired power plants 3.hydro power plants 4.Manufacturing and chemical plants
Key Features: 1.Configurable pressure display units 2. 2 independent limit switches with many configuration options 3.Analog signal output with possibility of characteristic curve spread, curve reversal and offset setting 4.Characteristic curve implementation via table with max. 30 measuring points 5.Complete configurable parameters and measuring point protocol possible through optional transmitter PC interface Key Specifications: 1.Relative pressure Measuring range: 0 ~ + 1.6 bar to 0 ~ +60 bar Overpressure: 4 bar ~ 200 bar Burst pressure: 7 bar ~ 250 bar Characteristics curve deviation: 0.5% FS or 1.0% FS 2.Vacuum and ± measuring ranges: Measuring range: 0 ~ (-) 1.0 bar to (-) 1 ~ +24 bar Overpressure: 4 bar ~ 100 bar Burst pressure: 7 bar ~ 150 bar Characteristics curve deviation: 1.0% Full scale 3.Permissible ambient temperature: -10° C ~ +70° C 4.Permissible media temperature: -10° C ~ + 70° C 5.Protection class: IP65 per DIN EN 60529 6.Non-linearity: < 1.0% full scale 7.Hysteresis: < 0.5% full scale 8.Power supply: 24 V AC/DC 9.Analog output signal: (0) 4-20mA / 0-10V 10.Output contacts: 2 potential free relay contact (32V AC/DC , 2A) or semiconductor switches (3~32 V AC/DC, 0.25A), configurable 11.EMC: EN 61326-1:2013, EN 61326-2:2013 12.Material (housing): stainless steel 1.4301 13.Process connection (media contact): stainless steel 1.4404 14.Measuring diaphragm: ceramic 15.Display: 4..6 digit LCD, full graphic, color changing 16.Configurable: attenuation, switching output, measuring range unit, output signal, zero point stability, implementation of characteristic curve, password Application areas: 1.Pump Control system 2.pump and compressors monitoring 3.Filling level measuring Industrial areas: 1.Process engineering 2.Environment engineering 3.Renewable energy eg. biogas etc 4.Waste Water Engineering 5.Effluent treatment 6.Breweries, alcohol industry
Key features: 1.Catalytic bead based pellistor sensor cell with low flash energy 2. 10-bit microprocessor control unit 3.Non-intrusive one man calibration via hall effect switches 4.Atex certified explosion proof / flameproof, suitable for zone 1, 2 gas explosion installation 5.Linear, proportional analog industry standard current output 6.Continuous system self-diagnosis with watch dog 7.Flashback arrestor with sintered filter 8.Auto zero point tracking to zero point compensation 9.Sil 2 hw tuv certified 10.Rs485 serial interface with modbus rtu communication (optional) 11. 1 or 3 relay output module (optional) 12.System and alarm led indicators (optional) 13.Modbus rtu communication over rs485 serial interface Technical specifications: Measuring parameters: hydrogen gas flammability or leakage Sensor technology: catalytic bead based pellistor sensor cell Measuring range: 0 ~ 100 % lel ( 0 ~ 4% v/v @ stp) Response time (t90): < 30 sec Control unit: 10 bit microprocessor based Warm up time: < 5 mins Auto zero point tracking for drift compensation Power supply: 24 vdc Ingress protection: ip65 Enclosure: stainless steel (for sensor cell), anti-static epoxy coated metal alloy (for transmitter) Output: linear, proportional 4-20ma Mounting: wall, duct, pipeline Safety integrity level: sil 2 Atex marking: ce 722 ex ii 2g eex d iic t6, ce 722 ex ii 3g eex na iic t6 Optional: lcd display, alarm leds, potential free relay contacts Hazardous area: zone 1, 2 Application: 1.Oil & gas, petrochemical, refinery 2.Battery rooms, ups facility 3.Mobile switching center (msc) of cellular / telecom site 4.Cracking plants 5.Hydrogenation plants 6.Chemicals 7.Cold stores 8.Pharmaceuticals, medicinal formulation
Key Features: 1.Robust design with high repeatability of switching contacts 2.Over pressure protection 3.Short circuit protection 4.Maintenance free due to inductive circuit movement Key Specifications: 1.Measurement range: 0-400 mbar to 0-6 bar 2.Operating temperature: Ambient: 0°C to +70°C 3.Protection class: IP54 per DIN EN 60529 4.Static operating pressure: 16 bar 5.Diaphragm: NBR or Viton 6.Measuring linearity: < 2.0% Full scale 7.Measuring hysteresis: < 1% Full scale 8.Operating voltage: 24 V DC/AC 9.Output signal: (0) 4-20 mA or 0-10 V, linear, proportional 10.Zero adjustment with the dial 11. 1 or 2 adjustable microswitches 12.Pressure chamber: Brass 13.Pressure connection: G 1/8, female thread Applications areas: 1.Water pumps, lube pump monitoring 2.Pump control 3.Pipe water / liquid flow monitoring 4.Air ducts monitoring Industrial areas: 1.HVAC & MEP applications 2.Cement plants 3.Hydro power plants 4.Manufacturing and chemical plants
Key Features: 1.High sensitivity 2.Robust Design, over pressure protected 3.Wear resistant sensor 4.High resistance to corrosion 5.Low hysteresis 6.Large LED Display Key Specifications: 1.Measuring range: 0 ~ 6 mbar to 0 ~ 60 mbar, max static pressure: 32 bar 0 ~ 32 mbar to 0 ~ 320 mbar, max static pressure: 140 bar 0 ~ 130 mbar to 0 ~ 1300 mbar, max static pressure: 140 bar 0 ~ 500 mbar to 0 ~ 5000 mbar, max static pressure: 140 bar 0 ~ 2 bar to 0 ~ 20 bar, max static pressure: 140 bar 2.Linearity: < 0.1 % 3.Hysteresis: < 0.1 % 4.Temperature coefficient: < 0.5 % / 10° C 5.Operating ambient temperature: -10° C to +70° C 6.Operating media temperature: 0° C to +80° C 7.Protection class: IP67 8.Electrical output: 4-20mA 9.Power supply: 24 V DC 10.Pressure connection: 2 x 1/4� NPT 11.Display: analog display with 0 ~ 100% scale. digital display (only with communication module option -K installed) 12.Electrical connections: internal terminal block 13.Material (media contact): Stainless steel 316 L (1.4404) 14.Electronic housing: Aluminum, surface coated 15.Marking / approval: CE mark, complies with EMV specifications EN 50082-1 and EN 50082-2 Application areas: 1.Filter technique 2.Precision measurements in air conditioning conduits 3.Clean room pressure compensation 4.Burner vacuum measurement 5.Circulating air controlling in furnaces Industrial areas: 1.Air conditioning and ventilation systems 2.HVAC and ventilation application 3.Environment monitoring 4.Clean room and laboratory rooms