Glass containers.
Spectrophotometers.
Lab instruments.
Product Name : Autoclavable Polypropylene Measuring Jugs 1000ml Product Description : Plastic Holloware : Autoclavable Polypropylene Measuring Jugs 1000ml. Item Code : OMLHP4 Price of product ( USD price or FOB price) : Contact Product origin : INDIA Key Specifications/Special Features : Different product grades with different performances can be available. Supply the most suitable grade according to customer requests. Minimum Order Size and Packgaing details : MOQ: 500pcs
Brazilian test apparatus It is also called rock tension testing machine. Brazilian test is a test for indirect measurement of tensile strength of rocks. The instrument is useful for testing specimen from 50 mm dia to 100 mm dia and of thickness of half the diameter. The specimen is held in circular jaws, this is primarily similar to a compression machine and consists of a small load frame having sturdy base with two vertical threaded rods and an adjustable cross head. The hydraulic jack is fitted at the centre of the base of the load frame. The jack of the load frame is self retracting and two plain plates are supplied. A pressure gauge capacity 0-200kn x 2 kn is fixed at the base of jack. A maximum pointer is also provided on the gauge, a pair of semi circular platen for 50 mm dia samples also provided. This instrument can be used in field also. Supplied complete with the steel balls. Order code Product Lisc-563 Brazilian test apparatus with 50 mm dia jaws
Conforms to is: 10050-1981, & astm d 4644 This apparatus is used to assess the resistance offered by a rock sample to weakening and disintegration when Subjected to drying and wetting in a slaking fluid, usually water. The equipment meets the essential Requirements of is:10050 -1981 & astm d 4644 and comprises the following: A motor drive with reduction gear mounted on a base board and capable of rotating four drum assemblies at a Constant speed of 20 rev/min approximately. The motor drive is totally enclosed in a hinged cover for quick Accessibility. An operating switch is provided in the cover. Two / four test drums made of brass wire mesh, with one end closed and having a removable cover on the other End. They have suitable couplings for mounting in the perplex water troughs. The drums are 140 mm in diameter And have an unobstructed length of 100 mm. Two / four perplex water troughs, accommodate one test drum each. These drums carry quick couplings on either End which are in turn coupled with couplings of the motor drive. The troughs allow 40 mm unobstructed clearance Below the test drum. A water level mark is provided in each water trough 20 mm below the axis of rotation of the Drum. Suitable for operation on 220 volts, 50 hz, single phase ac supply. Order code Lisc-557a Lisc-557b No. Of test drums 2 4
Consolidation apparatus (single gang model) Consolidation test is unidimentional test considered extremely important in soil mechanics. Sample taken from adjacent areas of a single site show differential settlement even when tested using same techniques. Soil of similar strength may show varying consolidation. Samples are very carefully prepared and vertical settlement of the specimen in saturated or drained conditions carefully recorded when known load is applied. Specifications: The standard outfit comprises of the following items. Loading unit, maximum capacity 20kg/cm sq. Having a loading yoke connected to a lever arm with a counter balancing adjustment and having a lever ratio of 1:1 the whole assembly being mounted on a sturdy steel frame stand. The loading unit is so designed that it can be used for consolidation cells of different diameters as well as different diameter floating ring type consolidation cells. Fixed ring type consolidometer (odometer) cell assembly for testing 60 mm dia x 20 mm thick specimen Consolidation apparatus (three gang model) Consists of 3 consolidation test assemblies mounted on a single frame. Complete with 3 sets of consolidometer cell assembly for 60mm dia samples and three sets of weights each giving 10kg/sq.Cm. On each sample. Consolidation apparatus (six gang model) Same as above but six units mounted on a single frame.
The direct shear apparatus we offer is designed as per is: 2720 (part-viii), astm d 3080 standards. Direct shear apparatus is extensively used for determining the direct shear strength of soils on specimen size 60mm x 60mm x 25mm. The direct shear apparatus we manufacture is electrically operated to give a 6 rates of strain of 1.25, 0.25, 0.05, 0.01, 0.002 & 0.0004mm/min and is suitable for 230v a.C. Specifications: the apparatus comprises of the following: Loading unit: The loading unit is provided with v strips and roller strips for friction-less movement of shear box housing. Supplied with load yoke with direct and lever system for applying load. Normal stress capacity 8kg/sq.Cm. Load is applied either directly or through a counter balanced detachable lever. Provision is made for the load to be applied either through a steel ball recessed on the pre collaborated loading yoke. Shear box assembly: Comprises direct shear box in two halves for a square specimen size 60 x 60 x 25mm one pair of plain gripper plates, one pair of porous stones, one pair of perforated gripper plates, one top loading pad. Shear box housing: It accommodates the direct shear box assembly. Complete with two ball roller strips. Specimen cutter: Used for cutting 60 x 60 x 25mm specimen from larger samples Set of weights to give a normal stress of 3kg/sq.Cm. Through leverage as follows. To give kg/cm.Sq. Qty. 0.05 - 4 nos. 0.1 - 1 no. 0.2 - 1 no. 0.5 - 3 nos. 1.0 - 1 no. Supplied with essential accessories: 1. High sensitivity compression proving ring cap 200kg 2. One consolidation dial gauge 0.01 mm x 25mm 3. One strain dial gauge 0.01mm x 25mm.
This method is used for determining the ductility of bituminous / asphaltic materials by measuring the elongation before breaking when two ends of a briquette specimen are pulled apart at a speed of 50mm/min ±25mm per mount at a temperature of 25c ± 0.50c. Specifications: The apparatus consists of a water bath with a digital temp. Controller cum indicator, and a circulating pump to maintain uniform water temperature. One half of the briquette moulds is fixed on a fixed plate in the water bath, the other half of the briquette mould is fixed to a carrier which slides over a rotating threaded shaft with a clutch. The motor and gears to rotate the shaft are housed in a cabinet fixed above the other end of the bath. A Pointer fixed to the carrier moves over a scale graduated from 0-110 cm x 1mm fixed on the bath with “0” (zero) of the scale towards the fixed plate side. The rotating shaft has 2 speeds of travel for the bracket, 5cm/min and 1 cm/min. Selected by a clutch. Water bath inside is stainless steel with an insulation and a water drain. A heater with digital temp. Controller cum indicator is fixed inside the water bath. Control switches for motor, stirrer, heater and indicator lamps are fixed at a convenient place on the water bath. Supplied complete with three ductility moulds and one base plate. Operates on 230 volts a.C. Single phase.
Seed counters are extensively used for seed counting in numerous botanical and agricultural laboratories. Features: Accurate counting of seeds. Light weigh. Requires no maintenance. Batching, repeat and multiple batches creating facility. Accurately counts a predetermined number of seed in a single batch count and allows for the continual duplication of a single batch count. Specifications: Display: seven segment fnd display. Seed size: 0.5 mm to 15 mm. No. Of seed: up to 9999 seeds in one batch. Computerized seed counter Specifications: Display: 2x16 column alphanumeric lcd display Seed size: 0.5 mm to 15 mm. No. Of seeds: in one batch: up to 999999 seeds Features: Facility to interface with printer / computer. 15 memory for storing different seed counts. Menu driven with facility for selecting of various seeds. Simultaneous display of preset count and actual count. Multiple batches and totalizing facility available. Auto/manual mode selection available in case of multiple batches. Buzzer indication after every count.
This instrument is used to test the oxidation stability of gasoline and can be used for determination of oxidation stability of petroleum under accelerated oxidation, to evaluate the possibility of colloid generation during oxidation of petroleum products. Our liop-177 gasoline oxidation stability tester comprises with following components: 1. Liquid bath:- square in shape. Inner chamber made of stainless steel and outer made of mild steel duly powder coated. The gap between is thermally insulated. Bath liquid stirring by motorized stirrer. Bath temperature control by microprocessor based controller. There will be provision of placing two number bomb in bath. Fitted with a over heating cutout system and supplied with two number s.S cover to cover the hole of the bath when not in use. 2. Oxidation bomb:- made of stainless steel and highly polished.& glass container. (1 no) 3. Pressure gauge (1no) 4. Quick coupling with oxygen filling device. Features:- 1, the oxidation stability of gasoline tester is compact, easy to operate and comfortable. 2, it can simultaneously accommodate two standard oxygen bomb and easy to assembly and disassemble. 3. Oxygen bombs are made of stainless steel 4, liquid bath is made of stainless steel, rust-proof and durable. 5. The oxidation bath is airtight, no vibration, no noise and no need for fluid replacement during the test. Technical parameters: •Electrical power: 220v± 10% 50hz ac, •Heating power: 2000 w. •Stirring motror1/83 h.P. •Temperature testing range: 105 c. •Temperature accuracy: ± 0.1°c. •Oxygen bomb pressure: range 0 ~ 1500kpa. •Pressure accuracy: 1 f.S. •Sampling time: 1 f.S. Applications: education / research, petroleum industry, power generation etc.
Originated in the Nordic Countries Nord Test is a trademark of conformity assessment. The emphasis of Nord Test is to develop, promote and innovate Nordic test methods and pre-normative activity. SCOPE: This procedure is for determination of the chloride migration coefficient in concrete, mortar or cement-based repair materials from non-steady-state migration experiments. FIELD OF APPLICATION: The method is applicable to hardened specimens cast in the laboratory or drilled from field structures. The chloride migration coefficient determined by the method is a measure of the resistance of the tested material to chloride penetration. This non-steady-state migration coefficient cannot be directly compared with chloride diffusion coefficients obtained from the other test methods, such as the non-steady-state immersion test or the steady-state migration test. DEFINATONS Migration: The movement of ions under the action of an external electrical field. Diffusion: The movement of molecules or ions under a concentration gradient or, more strictly, chemical potential, from a high concentration zone to a low concentration zone. SAMPLING: The method requires cylindrical specimens with a diameter of 100 mm and a thickness of 50 mm, sliced from cast cylinders or drilled cores with a minimum length of 100 mm. Three specimens should be used in the test. TEST METHOD: Principles: An external electrical potential is applied axially across the specimen and forces the chloride ions outside to migrate into the specimen. After a certain test duration, the specimen is axially split and a silver nitrate solution is sprayed on to one of the freshly split sections. The chloride penetration depth can then be measured from the visible white silver chloride precipitation, after which the chloride migration coefficient can be calculated from this penetration depth. Apparatus: • Vacuum container: capable of containing at least three specimens. • Vacuum pump: capable of maintaining a pressure of less than 50 mbar (5 kPa) in the container. • Migration set-up: includes the following parts: – Silicone rubber sleeve: inner/outer diameter 100/ 115 mm, about 150 mm long. – Clamp: diameter range 105 - 115, 20 mm wide, stainless steel. – Catholyte reservoir: plastic box, 370 × 270 × 280 mm (length × width × height). – Plastic support. – Cathode: stainless steel plate about 0.5 mm thick. – Anode: stainless steel mesh or plate with holes about 0.5 mm thick. • Power supply: capable of supplying 0 - 60 V DC regulated voltage with an accuracy of ±0.1 V. • Ammeter: capable of displaying current to ±1 mA. • Thermometer or thermocouple with readout device capable of reading to ±1 °C. • Any suitable device for splitting the specimen. • Spray bottle. • Slide caliper with a precision of ±0.1 mm. • Ruler with a minimum scale of 1 mm. • Equipment for chloride analysis as required by the test method employed.
The Aniline Point of an oil is defined as the minimum temperature at which equal volumes of aniline (C6H5NH2) and the oil are miscible, i.e. form a single phase upon mixing. The value gives an approximation for the content of aromatic compounds in the oil, since the miscibility of aniline, which is also an aromatic compound suggests the presence of similar (i.e. aromatic) compounds in the oil. The lower the aniline point, the greater is the content of aromatic compounds in the oil. The aniline point serves as a reasonable proxy for aromaticity of oils consisting mostly of saturated hydrocarbons (i.e. alkanes, paraffins) or unsaturated compounds (mostly aromatics). Significant chemical functionalization of the oil (chlorination, sulfonation, etc.) can interfere with the measurement, due to changes to the solvency of the functionalized oil. METHOD A: ANILINE POINT APPARATUS as per IP 2 & IS 1448 (P-3), ASTM D 611 METHOD A, complete with jacket (without thermometer) Optional Accessories: • Spare outer jacket with cork Spare tube with cork • Heater for above with energy regulator METHOD B: ANILINE POINT APPARATUS as per IP-2 method B, IS 1448 (P-3), ASTM D 611 by thin film METHOD B, Electrically heated with motorized stirrer (without thermometer). The apparatus consists of an Archimedean type pump ie. glass tube pump body, S.S. pump, variable speed small motor, within an Aniline sample container with an integral light well, illuminated by a 6 V lamp. The whole assembly is heated in small glass beaker bath controlled by energy regulator. Electrically operated stirrer is also provided. Optional Accessories: • Spare tap • Spare Contraction chamber • Spare metal stirrer METHOD C: ANILINE POINT APPARATUS for volatile liquids as per IP-2 method ‘C’ (without thermometer). METHOD D: ANILINE POINT APPARATUS as per IP-2 1977, METHOD D by U-tube method electrically heated with FHP stirrer without thermometer. The apparatus consists of U-tube assembly which is mounted in a glass bath which is heated electrically and controlled by energy regulator. A small electric motor stirrer is provided for the bath. Optional Accessories: • Spare ‘U’ tube Thermometer for Aniline Point: • I.P.20C (-38/42ºC x 0.2C). • I.P.21C (-25/105ºC x 0.2C). • I.P.59C (90/170C x 0.2C).
The apparatus consists of brass test cup with handle removable cup cover with spring operated rotating shutter having oil test jet flame device, stirrer with flexible shaft. The assembly rests in air bath which is covered with dome shape metal top. The cup is fitted with insulated handle and locking arrangement near cup flange. The assemble is kept on round shape electric heater with temp. Regulator. Suitable for operation on 220 volts 50 hz. Pensky marten flash point apparatus (semi automatic) Our semi-automatic pensky martens flash point apparatus are available with following features: This apparatus is made as per ip34, astm d–93 and is 1448 (part i) 1270 (p.21) and is 1209-1953 method b. Used for finding out flash point above 70°c and below 300°c. The instrument having oil test jet (or) gas test jet flame device, stirrer with flexible shaft. The assembly rests in air bath which is covered with dome shape metal top. The cup is fitted with insulated handle and locking arrangement near cup flange. Electronic temperature controller with automatic dipping cycle with remote control oil (or) gas jet. Suitable to operate on 220 volts, 50 hz. Pensky marten flash point apparatus (fully automatic) Fully automatic pensky marten flash point apparatus is fitted with microprocessor controller with lcd display. Temperature range form 80 c to 350 c with 0.01c direct resolution. Automatic stirrer gas test jet system.
For general laboratory use for various experiments. Made of polished brass, each mass has a standard keyhole slot to retain on hanger. Each mass and hanger is stamped with its own value
Weight - 25 grams Width - 2.5 – 3.0 mm Thickness - 0.3 – 0.5 mm Length - 55 – 60 feet Appearance - In the form of a reel.
Blue and red litmus paper pkg. Of 100 leaves.
Nickel-plated brass tube with a free moving air regulator and serrated gas inlet nickel-plated brass tube, 9mm O.D. Base made of stamped steel sheet. Base dia 80mm and overall height 140mm approx. Powder coated or stove enamel finish. NATURAL GAS, 11mm dia tube L.P.GAS, 11mm dia tube NATURAL GAS, 13mm dia tube L.P.GAS, 13mm dia tube COAL GAS, 13mm dia tube.
Made from seasoned wood with both edges divided in mm and numbered every 10mm, nicely polished. Horizontal and vertical reading.
Feature It can automatically record the temperature while the deformation of the specimen reaches the preseting value and the test of HDT/VICAT ;it can be easily performed respectively by replacing the header of the loading rod. Weight 426 kg Dimension 140X65X180 cm