FS5001B series mass flow sensors are designed for general purpose flow monitoring and control applications. The sensors directly measure mass flow in the designed channel with trace flow detection capability. The lowest flow it can detect is 20 uL/min. These sensors can readily be applied for manifold flow assembly, leak detection, HVAC control, clean room air flow or nitrogen flush monitoring and control, environmental equipments such as air sampler, analytical instrumentation such as GC spectrometer. FS5001 can be configured to measure flow full scale from 100 sccm to 1000 sccm (1 SLPM). With a full spectrum of customizable adaptors, it can be plug-and-play in many applications. Features and Applications - Low mass flow detectable from 0 ~ 200 sccm up to 0 ~ 1000 sccm - Outstanding accuracy of 2.0% - Response time < 10 ms - Pressure rating up to 5 bar (73 psi) - Output: analog or both analog and digital
FS7002 series mass flow/clog sensors can be used for open air space flow measurement or applied for clog sensing in an open space configuration. The sensor can measure air flow up to 10 m/sec with a fast response. The compact design make the installation an easy task. Examples are clog sensing in LCD projector; HVAC air flow monitoring, air fresher and fan status monitoring. Features and Applications - Measure open space air flow up to 10 m/sec - Fast response < 20 msec - Compact miniature design - Excellent sensitivity - Bi-direction capability - Additional customization available
FS1015CL series mass flow sensors are specially designed for medical equipment flow monitor and control applications, and are made with world leading proprietary MEMS mass flow designed channel with a low pressure loss. The current models can be readily applied to ventilators and anesthesia equipments. These sensors can also be sterilized in medical liquids for reuse or hygienic purposes. FS1015 Series can measure a flow up to 150 SLPM. ISO-15mm connection model is readily applicable to ventilators and/or anesthesia equipments. Features and Applications - MEMS thermal mass flow sensor - Excellent rangeability with integrated multiple sensing elements - High stability at null and full scale - Fast response - Low power consumption - Low pressure loss
FS4003/08 series mass flow sensors are designed for general purpose flow monitor and control applications, and are made with world leading proprietary MEMS mass flow sensors and the smart electronic control system. The sensors directly measure mass flow in the designed channel with a low pressure loss. These sensors can readily be applied for electronics flow meters for anesthesia equipments, clean room air flow or nitrogen flush monitor and control, environmental equipments such as air sampler, analytical instrumentation such as GC spectrometer. FS4008 can be configured to measure flow up to 50 SLPM. It can be applied for gas flow measurement and/or control equipments. Applications include electronic flow meter for anesthesia equipments, clean room gas flow monitor, air sampler, and gas analyzer. Features and Applications - Designed for 3 and 8 mm package - Mass flow detectable from 0 ~ 2 SLPM to 0 ~ 50 SLPM - Exchangeable connectors for easy installation - Digital and analog output provide easy access for various communications - Compact design ready for multiple channel assembly - Excellent for electronic meters in anesthesia equipment - Fast response and low power consumption - Low pressure loss
FS4001 series mass flow sensors are manufactured using MEMS flow sensor and package technology. The sensors are specially designed for low flow rate range applications from 0 ~ 30 sccm up to 0 ~ 1000 sccm. The maximum flow rate for each model is manufactured via specially designed package as well as smart electronics so that the optimal sensitivity would be achieved. Features and Applications - Low mass flow range from 0 ~ 30 sccm up to 0 ~ 1000 sccm - Outstanding accuracy of ±1.5 % - Fast response (4 ms selectable) - Pressure rating up to 5 bar (73 psi) - Analog and/or digital user interface - Easy installation
INFRARED SENSOR WITH SILICON LENS SMTIR9902SIL Typical Applications * Contactless measurement of surface temperatures * Temperature measurement of moving objects * Remote measurement due to small angle of view * Climate control * Medical instruments Introduction The Smartec infrared sensor type SMTIR9902SIL is a standard Smartec SMTIR9902 sensor equipped with a silicon lens for measuring radiation temperatures within a small angle of view (7.27'). The SMTIR9902SIL contains a NI1000 temperature sensor for measuring the temperature of the sensor itself. The temperature range of this internal sensor is -20 to 100 'C. The sensor is mounted in a modified TO-05 encapsulation.
Zirconia O2 Sensors Probe Series - Short Housing The Probe Range of zirconium dioxide oxygen sensors are available in three lengths. Suitable for aggressive and polluted applications such as boiler exhausts. Longer probes are an ideal solution for thicker walled, insulated flue pipes. FEATURES * Zirconium dioxide (ZrO2) sensing elements * Long life, non-depleting technology * Integral heating element * High accuracy * Requires an external interface board to operate BENEFITS * No reference gas required * No need for temperature stabilisation * Compact enclosure TECHNICAL SPECIFICATIONS Heater voltage Operating (standard response) 4V DC ± 0.1V DC (1.7A) Standby 1.65V DC (0.7A) Operating (fast response) 4.35V DC ± 0.1V DC (1.85A) Standby 2V DC (0.85A) Pump impedance at 700'C < 6kΩ Permissible gas temperature -100'C to +250'C Gas flow rate 0 ~ 10 m/s Repetitive permissible acceleration 5g Incidental permissible acceleration 30g OUTPUT VALUES Oxygen pressure range 2mbar ~ 3bar max Accuracy 5mbar max Internal operational temperature 700'C Response time (10 - 90% step) Standard response sensor < 15s Fast response sensor < 4s Warm up time (prior to sensor operation) 60s Warm up time (from standby) 20s Output stabilisation time ~ 180s
SO-E2-960 Limiting Current Type Sensor Oxygen Sensors When voltage is applied to a zirconia electrolyte cell, oxygen is pumped through the zirconia disc from the cathode side to the anode side because the carriers of the current flowing through the zirconia electrolyte are oxygen ions. By attaching a cap with a pinhole on the cathode side of the cell and by increasing the voltage over the cell the current shows saturation due to the rate limiting step in the transfer of oxygen to the cathode. This saturation current is called limiting current and is nearly proportional to the ambient oxygen concentration. Below the advantages of the oxygen sensor: measuring range 1.00 to 96.0 vol.% oxygen High accuracy For many types a more or less linear characteristic Small temperature dependence of the sensor signal Low interference with other gases Long service life In many cases "Single point calibration" necessary only once Applications: Medical Laboratory Food industry Household/Gastronomy Measuring technique Security technology/Monitoring (Electrical-) industry Characteristic Data: Measuring gas: Oxygen concentration Measuring medium: Gaseous atmosphere Measuring principle: Limiting current type sensor Measuring ranges: 1.00 - 96.0 vol.% O2 Response time (t90): 2 to 25 sec. (Depends on: sensor type, gas flow, measuring chamber) Sensor voltage / heating voltage / power consumption / heater cold resistance Sensor voltage: 0.7 to 1.6 Volt Heating voltage: 3.6 - 4.4 Volts Power consumption: 1.3 to 1.8 Watts (depends on application and packaging) Cold resistance: R( 25'C ) = 3.25 ohm ± 0.20 ohm Warm up time: Min. 30 s
Zirconia O2 Sensors Probe Series - Long Housing FEATURES * Zirconium dioxide (ZrO2) sensing elements * Long life, non-depleting technology * Integral heating element * High accuracy * Requires an external interface board to operate BENEFITS * No reference gas required * No need for temperature stabilisation * Two lengths available; 220mm and 400mm TECHNICAL SPECIFICATIONS Heater voltage Operating 4V DC ± 0.1V DC (1.7A) Standby 1.65V DC (0.7A) Pump impedance at 700'C < 6kohm Permissible gas temperature Standard temperature -100'C to +250'C High temperature -100'C to +400'C Gas flow rate 0 - 10 m/s Repetitive permissible acceleration 5g Incidental permissible acceleration 30g OUTPUT VALUES Oxygen pressure range 2mbar - 3bar max Accuracy 5 mbar max Internal operational temperature 700'C Response time (10 - 90% step) < 15s Warm up time (prior to sensor operation) 100s Warm up time (from stand by) 20s Output stabilisation time ~ 180s
MB1240 XL-MaxSonar-EZ4 High Performance Ultrasonic Rangefinder Product Description The XL-MaxSonar-EZ4 has the highest noise tolerance and narrowest beam of any of our indoor sensors. The sensor is designed and calibrated to provide reliable range information to large targets even in environments with strong acoustic or electrical noise sources. MB1240 Features and Benefits * Narrowest beam in the XL-MaxSonar-EZ/AE sensor line * Low power consumption * Easy to use interface * Large target detection * Acoustic noise rejection * 3.3v to 5.5v operational voltage MB1240 Applications and Uses * Great for people detection * Security * Motion detection * Recommended for multi-copters and UAV's * Used with battery power * Autonomous navigation * Educational and hobby robotics * Collision avoidance -
Mb7389 Hrxl-maxsonar-wrmt High performance ultrasonic precision rangefinder Product description The hrxl-maxsonar-wrmt ignores smaller targets and only reports the range to target with the largest acoustic return. This is our most advanced weather resistant sensor designed for target detection and ranging outdoors or in tank or bin applications. Mb7389 features and benefits * factory calibrated beam width * low operating voltages from 2.7v to 5.5v * all range outputs are active simultaneously * superior clutter rejection Mb7389 applications and uses * bin level measurement * tank level measurement z
Humidity Module HTG3513CH Voltage Output Humidity Sensor DESCRIPTION Based on the rugged HUMIREL humidity sensor, HTG3513CH is a dedicated humidity and temperature plug and play transducer designed for OEM applications where a reliable and accurate measurement is needed. Direct interface with a micro-controller is made possible with the module's humidity linear voltage and direct NTC outputs. HTG3513CH is designed for high volume and demanding applications. FEATURES * Voltage Supply: 3.3 Vdc * Nominal Output @55%RH: 1.462 - 1.568 V * Humidity Average Sensitivity: +18 mV/%RH * Current consumption: 1.0 mA dc * Humidity Measuring Range: 0 - 100 %RH * Humidity Operating Range: 0 - 100%RH * Temperature Operating Range: -40 - 110'C * Suitable for small bulk assembly * Product free from Lead, Cr (6+), Cd and Hg. Compliant with RoHS * Full interchangeability. Better than +/-3%RH and +/-0.25'C * Humidity calibrated within +/- 3% RH @ 55% RH * Temperature measurement through NTC direct output * Demonstrated reliability and long term stability * Reliability not affected by repeated condensations APPLICATIONS * Automotive * Home Appliance * Printers -
HTG3535CH Humidity and Temperature Sensor Module with voltage output DESCRIPTION Based on the rugged HUMIREL humidity sensor, HTG3535CH is a dedicated humidity and temperature plug and play transducer designed for OEM applications where a reliable and accurate measurement is needed. Direct interface with a micro-controller is made possible with the moduleâ??s humidity linear voltage and direct NTC outputs. HTG3515CH is designed for high volume and demanding applications. FEATURES * Voltage Supply: 5 Vdc * Nominal Output @55%RH: 2.401 - 2.559 V * Humidity Average Sensitivity: +26 mV/%RH * Current consumption: 1.2 mA dc * Humidity Measuring Range: 0 - 100 %RH * Humidity Operating Range: 0 - 100%RH * Temperature Operating Range: -40 - 110'C * Suitable for small bulk assembly * Product free from Lead, Cr (6+), Cd and Hg. Compliant with RoHS * Full interchangeability. Better than +/-3%RH and +/-0.25'C * Humidity calibrated within +/- 3% RH @ 55% RH * Temperature measurement through NTC direct output * Demonstrated reliability and long term stability * Reliability not affected by repeated condensations APPLICATIONS * Automotive * Home Appliance * Printers -
Frequency Output Temperature and Humidity Sensor HTF3226LF DESCRIPTION Based on the rugged HS1101LF humidity sensor, HTF3226LF is a dedicated humidity and temperature transducer designed for OEM applications where a reliable and accurate measurement is needed. It features a miniature connector for easy, cost-effective mechanical mounting. Direct interface with a micro-controller is made possible with the moduleâ??s linear frequency output. FEATURES * Full Lead free product * Calibrated within +/-5% @55%RH * Small size and very cost effective * Miniature connector (JST) * 10kOhms +/-3% NTC temperature sensor (1% optional) * The best combination of cost effectiveness and performance * Stable, linear proportional frequency output from 10% to 95%RH * Stable and reproducible characteristics with temperature * High reliability and long term stability Humidity Sensor Specific Features * Instantaneous de-saturation after long periods in saturation phase * Fast response time * High resistance to chemicals * Not affected by water immersion * Patented solid polymer structure Temperature Sensor Specific Features * High quality thermistor * Stable * High sensitivity APPLICATIONS * Printers * Home Appliance -
Voltage Output Temperature and Humidity Sensor HTG3515CH DESCRIPTION Based on the rugged HUMIREL humidity sensor, HTG3515CH is a dedicated humidity and temperature plug and play transducer designed for OEM applications where a reliable and accurate measurement is needed. Direct interface with a micro-controller is made possible with the module's humidity linear voltage and direct NTC outputs. HTG3515CH is designed for high volume and demanding applications. FEATURES * Voltage Supply: 5 Vdc * Nominal Output @55%RH: 2.401 - 2.559 V * Humidity Average Sensitivity: +26 mV/%RH * Current consumption: 1.2 mA dc * Humidity Measuring Range: 0 - 100 %RH * Humidity Operating Range: 0 - 100%RH * Temperature Operating Range: -40 - 110'C * Suitable for small bulk assembly * Product free from Lead, Cr (6+), Cd and Hg. Compliant with RoHS * Full interchangeability. Better than +/-3%RH and +/-0.25'C * Humidity calibrated within +/- 3% RH @ 55% RH * Temperature measurement through NTC direct output * Demonstrated reliability and long term stability * Reliability not affected by repeated condensations APPLICATIONS * Automotive * Home Appliance * Printers -
Temperature and Relative Humidity Sensor Module Description: Based on the rugged HS1101LF humidity sensor, HTF3000LF is a dedicated humidity and temperature transducer designed for OEM applications where a reliable and accurate measurement is needed. It features a very small size for easy, cost-effective mechanical mounting. Direct interface with a micro-controller is made possible with the module's linear frequency output. Features: * Small size product * Compliant with RoHS recommendations and most of Lead Free Soldering Process * Humidity calibrated within ±3% @55%RH at 5Vdc * Stable, proportional frequency output from 0 to 100% RH * High quality thermistor * One of the smallest humidity/temperature modules on the market * High reliability and long term stability * Not affected by water immersion * Stable characteristics with temperature * Part could be washed with distilled water Humidity Sensor Specific Features: * Instantaneous de-saturation after long periods in saturation phase * Fast response time * High resistance to chemicals * Patented solid polymer structure Temperature Sensor Specific Features: * 10kΩ ±1% NTC temperature sensor * Stable * High sensitivity APPLICATIONS: * Printers * HVAC controller -
MB7589 SCXL-MaxSonar-WRMT Self Cleaning Precision Ultrasonic Rangefinder Product Description The weather resistant SCXL-MaxSonar-WR selfâ??cleaning sensor is a rugged ultrasonic sensor component module. This outdoor sensor provides very short to long distance detection and ranging in a compact, robust PVC housing. The ultrasonic sensor meets the IP67 water intrusion standard and matches standard electrical 3/4-inch PVC pipe fittings. MB7589 Features and Benefits * Factory calibrated beam width * Low operating voltages from 2.7V to 5.5V * All range outputs are active simultaneously * Superior clutter rejection MB7589 Applications and Uses * Bin Level Measurement * Tank Level Measurement z
MB1444 USB-ProxSonar-EZ4 High performance USB ultrasonic proximity detection sensor Product Description The USB-ProxSonar-EZ4 has a detection zone of ~1 feet and will allow for 15+ simultaneous sensors. These ultrasonic proximity sensors detect objects in a calibrated detection zone. The USB-ProxSonar-EZ sensors report when an object (such as a person) enters the detection zone. The target is released after leaving the USB-ProxSonar-EZ detection zone. Product Specifications * USB interface * ~2.5 second target acquire time * ~1.5 second target release time * Automatic multi-sensor operation * People sensor * Resolution of 1 inch * Maximum Range of 125 inches (318 cm) * Detection zone range of 12 inches (30 cm) * 42kHz Ultrasonic sensor measures distance to objects * RoHS compliant * Virtually no sensor dead zone, objects closer than 6 inches range as 6 inches * Small, light weight module * Designed for easy integration into your project or product * Short range detection * Quote Request Form: For orders greater than 100 sensors -
MB1040 LV-MaxSonar-EZ4 High Performance Ultrasonic Rangefinder Product Description The LV-MaxSonar-EZ4 is the narrowest beam width sensor that is also the least sensitive to side objects offered in the LV-MaxSonar-EZ sensor line. The LV-MaxSonar-EZ4 is an excellent choice when only larger objects need to be detected. MB1040 Features and Benefits * Best side object rejection in the LV-MaxSonar-EZ sensor line * Low power consumption * Easy to use interface * Best for large object detection * Can be powered by many different types of power sources * Can detect people up to approximately 4 feet MB1040 Applications and Uses * Landing flying objects * Used with battery power * Autonomous navigation * Educational and hobby robotics * Collision avoidance -
Model TS318-1B0814 Thermopile Sensor * Thermopile IR-Sensor * For Contact less Temperature Measurement * Single Element * Small Package for Ear Thermometer * High Signal * Flat Filter * Accurate Reference Sensor DESCRIPTION Thermopiles are mainly used for contact less temperature measurement in many applications. Their function is to transfer the heat radiation emitted from the objects into a voltage output. FEATURES * High Signal * Ni-RTD Reference Sensor * Small TO-18 Package * 8-14µm Band Pass Filter for measurement distances >0.5m APPLICATIONS * Pyrometers (general) * Industrial Pyrometers -