Zirconia O2 Sensors Probe Series - Long Housing FEATURES * Zirconium dioxide (ZrO2) sensing elements * Long life, non-depleting technology * Integral heating element * High accuracy * Requires an external interface board to operate BENEFITS * No reference gas required * No need for temperature stabilisation * Two lengths available; 220mm and 400mm TECHNICAL SPECIFICATIONS Heater voltage Operating 4V DC ± 0.1V DC (1.7A) Standby 1.65V DC (0.7A) Pump impedance at 700'C < 6kohm Permissible gas temperature Standard temperature -100'C to +250'C High temperature -100'C to +400'C Gas flow rate 0 - 10 m/s Repetitive permissible acceleration 5g Incidental permissible acceleration 30g OUTPUT VALUES Oxygen pressure range 2mbar - 3bar max Accuracy 5 mbar max Internal operational temperature 700'C Response time (10 - 90% step) < 15s Warm up time (prior to sensor operation) 100s Warm up time (from stand by) 20s Output stabilisation time ~ 180s