We have available following Ships spare parts for Sale: Product-Fire and Gas alarm Maker-Salwiko Ref no-SG 5820 Sr no-98033 Country of origin-Sweden
We have available following ships spareparts for Sale: Product-Electrostatic Alarm horn Maker-Yodalarm Type-Yo5/IS/C/T4 S/N -C6762
Model item: r2 Material:zinc alloy+abs Color:white/blue/green/black/yellow/red Version: bluetooth 4.0 System supported: upon android 4.3/upon ios7.0 Efficient distance: up to 10m Battery cell: cr2032 Dimensions: 73.3*29.8*11mm Weight: 26g Highlights: 1.Anti-lost(smart reminding, two-way paging, tracking location)/ remote shutter 2.Come with a key-chain design, easy to carry. 3.More light, more thin, more small. 4.Long distances for use, up to 10 meters. 5.Laser carving logo. 6.The alarm can be used by installing the battery, one piece button battery life is 3-6 months. Trade term: fob shenzhen Below packing details for your reference, 100pcs/ctn (50pcs/inner ctn) Carton size: 35.5 x 23.5 x 25.8cm N.W: 4.3kg G.W: 5.3kg Volume weight: 6.3kg
SNC-300 non-addressable photoelectric smoke detectors are state-of-the-art detectors suitable for connection to 2-wire or 4-wire non-addressable fire detection control and indicating equipment, or to addressable fire detection Control and indicating equipment that can accept non-addressable type detectors. Advanced electronics in conjunction with a photoelectric smoke sensing chamber provide early detection of fire And high immunity against unwanted alarms. Photoelectric smoke sensor Analogue detection discrimination Dual leds for 360° visibility 2-wire and 4-wire models for dc 12 v and dc 24 v operation 4-wire model for dc 48 v operation 4-wire models available with a n/o alarm relay output 4-wire models available with auto-reset 2-wire models available with remote led output Connects to zone monitor for use with addressable control and indicating equipment
1.Size:160l x 117w x 53h mm 2.Rated voltage:12v/24vdc 3.Rated current:80ma~100ma 4.Flash intensity =1.2ws, flash period1.5s 5.Audio alarm = 95 db 6.Temperature range:-10~+55 7.Humidity range:=95% 8.The life-span of flash lamp?s frequent flashing:=40000 times 9.The product?s index of flash is very great because it adopted the high volume flash lamp from german, it will shape up the effect from vision when input the low volume 10.Three kinds of alarm sound:the ambulance sound, the pumper sound, the police car sound
Product Introduction:This product named Manual Call Point,Website:,also called emergency door release button or manual pull button.1.Fire--When there is a fire,pull button to issue a signal to a fire alarm control panel,the control panel will showing the serial number of the call point or the location and send out alarm sound, once it received the signal.Access control--When there are chaos or emergency surround you,pull the call point to open the corresponding safety, door.2.Applicable type: safety, door, escape door, safety systemTechnical Parameters:Product nameManual Call PointBrandYIXINModelYX-BP562TypeGlass breakOperating voltage12-220VDCOperating current5AWithstood-voltage250VACContact modeNO/NCPoleSingle/Double pole optionalColorRed/Green/Yellow/Blue/White optionalCoverWith water-proof cover optionalDimension91*87*55mmWarranty1 YearProduct, Feature, :1.Key reset manual call point use plastic sheet which can reused and reset.2.It takes just a few seconds to reset the call point by Special key after pull.3.The manual call point can use its own, bottom case surface mounted or recessed mounted,easy to install.
SD12 Standalone Photoelectric Smoke Alarm Key Features: * Worry-free! 10-year battery life * Advanced photoelectric sensing technology offers high sensitivity * Auto-check malfunction * Low battery warning * Manual Test & Auto-Reset SD12 Standalone Photoelectric Smoke Alarm Specifications: * Sensor Type: Photoelectric * Alarm Sound: >85dB (3) * Power Supply: DC 3V lithium battery (included) * Power Supply Life: 10 years * Alarm Current:
SD13 Smoke Alarm Key Features: * Worry-free! 10-year sealed-in lithium battery * Advanced photoelectric sensing technology offers high sensitivity * Auto-check malfunction * Low battery warning * Manual Test & Auto-Reset * Dustproof, mothproof & Anti-visible light * Anti-RFI (20V/M-1GHz) SD13 Smoke Alarm Specifications: * Sensor Type: Photoelectric * Alarm Sound: >85dB (3meter) * Power Supply: DC 3V lithium battery (included) * Power Supply Life: 10 years * Alarm Current:
Features  � High stability optical chamber � Circular LED indicator for 360° visibility � Network by current, NONC optional � Adapts CMOS with low power consumption � High adaptability to the ambient with dustproof, mothproof,  moistureproof, anti-white light and high EMI immunity � Input voltage: 10-35V DC � Orientation differences:
Description & main functions: 1.Can connect external industrial camera, this system with own sms, mms, email functions 2.8 wired zones, open/closed alarm mode is optional by self-programming 3.Fixed code: 40 wireless zones, 315/433mhz(optional) 4.Digital inputs are adopted optical-coupled isolators, which can prevent external high voltage from destroying internal components. 5.Send sms automatically to report the state of digital input when it returns normal status. 6.Wireless keyboard for setting phone no. 7.Arm/disarm remotely through gsm sms 8.Modify zone content (chinese 70 words, english 140 letters ) 9.Send sms to 5 preset mobile phone numbers while alarming 10.Auto-dial 5 preset phone numbers while alarming and monitor the sound at site. 11.Record function: maximum recording time:1 min 12.Voice function: support play the user record voice 13.With wired mic interface and siren interface 14.Inquiry hosts status and alarm events through sms 15.Inquiry zones name and arm/disarm status through sms 16.Digital inputs are adopted cal-coupled isolators, which can prevent external high voltage from destroying internal. 17.Gsm network wireless communication for alarm, no pstn cable, not fear cable cut 18.Temper device: arming while the control panel removing or shaking. 19.Connect with alarm center through gsm network 20.With rohs/ce/fcc certifications, conform to 3c safety standard and gb12663-2001 government standard Main technical parameters , gsm frequency band:850/900/1800/1900mhz(quad band) , fixed code wireless signal frequency:315mhz/433mhz , wireless distance: 100-200m , response time�?�8s(gsm network normal) , fixed code zones:40 , working conditions: Operating temperature:-45~+60 humidity 95% no condensation , standby current :5ma , alarm current:
Name: Overhead Line Fault Indicator Certification: We have abtained VDE,UL,CE,ROHS,ISO9000 Approal and SGS Audit Supplier in China,We guarantee quality is the first. Product description: Built-in battery and power supply from the line Detect short circuit, earth fault and line current running status Three alarming methods: local daytime turnover alarm, LED alarm in night and optional remote GPRS/GSM Main function: Automatic reset The indicator's reset time 1-48 hours(can be set online), Or the local / remote flop reset( Flop with the Led display) Power The indicator is made with the new material and special circuit designed, through limiting groove to reduce permeability and vortex energy consumption on the media, When the lines' load current exceeds 7A ,the indicator began to take power Short-circuit criterion The indicator judges the short-circuit by the standard quick-break, over setting current ,parameters be set in real-time it can suppress the inrush current and power feedback , ensure a consistent with the transformer substation. It can be set as adaptive load current over current mutation criterion , also be set as adaptive load current short circuit over current mutation criterion. Alarm function: Local daytime turnover alarm, LED alarm in night Specification battery 5.4~6.5Ah/3.6V one long-life lithium batteries Take electric power 50uA-20mA/3.6V(Corresponds to a load current 7A~600A) Static average power consumption 40uA/3.6V(RF in the state of waiting to receive parameters and command) Dynamic average power consumption 50uA/3.6V( RF send data once per 5 minutes), 60uA/3.6V ( RF send data once per minutes), Available wire diameter 0~40mm(Insulated wire, bare wire) Available load current 0~600A(Default),0~100A,0~2000A,0~40 00A Quick-break Over current Delay 0~9.99S, Stepping0.01s(Wireless and remote GPRS online can adjust the parameters) Quick-break, over current settings 0~700A(Phase sequence 0~4000A/ Zero sequence 0~70A),Stepping 1A (Wireless and remote GPRS online can adjust the parameters) Maximum earth impedance 500 © Maximum short circuit current 40KA Communication distance 30~100m(11dbm, Open area), 100~300m(20dbm , Open area) Communication mode 420~440MHZ,can be divided into 10~20 Wireless band, Each band 64-speed automatic frequency hopping, bidirectional communication Voltage Linearity Better than ±5% Current Accuracy ±1%( Rated Current 100A) or ±1A(Load current 5000 times Relative humidity 95% Operating Altitude 2000m Weight 500 g Life 10 years Maximum wind velocity 35 m/s Seismicity 0.1g Visual angle 360 °
Product Introduction:This product named Manual Call Point,,is usually referred to as an MCP within the fire protection industry, as a "Fire Alarm Call Point" in US, or as a "break glass" in the UK. They are used to allow building occupantsto signal that a fire or other emergency exists within the building. They are usually connected to a central fire alarm panel which is in turn connected to an alarm system in the building, and often to a local fire brigadedispatcher as well.Manual call point is used to initiate an alarm signal.Break glass at the time ofthe fire to issue a signal to a fire alarm control panel,the control panel will showing the serial number of the call point or the location and send out alarm sound once it received the signal. It can be manual alarm systemor part of automatic alarm system. In the case of fire when the glass cover is broken, the push button will be released by the spring action and will actuate an alarm at the control panel through its switching contacts. Inaddition to this, there will be an LED indicator on the control panel for visual indication to locate the call point easily.Product Parameter:Product nameManual Call PointBrand nameYIXINModelYX-BP560TypeGlass breakOperating voltage12-220VDCOperating current5AWithstood-voltage250VACContact modeNO/NCPoleSingle/Double pole optionalCoverWith water-proof cover optionalColorRed/Green/Yellow/Blue/White optionalBreaked materialGlass sheet(Plastic film on glass)Dimension87*87*52mmWarranty1 YearProduct Feature:1.Available for flush or surface mounting2.Test key inserted from side to test after installation.3.Use plastic film on glass sheet avoid splash of broken pieces and hurt.4.Surface technology: fireproof material, dull polish5.Standard structure: fireproof material shell, easy to install. 6.Suitable for the majority of conventional fire alarm systems.
Introduction:The emergency door release manual call point is 3 poles with sounder and light. The manual call point are used to allow building occupants to signal that a emergency exists within the building.SpecificationsProduct NameEmergency Door Release Manual Call PointPower supplyDC 12-24VOperation currentDC 12V/18mA(Standby)/75mA(Operation DC 24V/11mA(Standby)/41mAOperation)BuzzerSet as silent, interval wailing or continuous wailingIndicatorDual-color (red and green).Red indicator to set blinking,off or on.OutputN.O.N.C.&COM.Output(Maximum load of 125V/3A)MaterialABS,PC(trasparent part)Starting parts typeReusableStarting modeManual pull down plateReset modeKey resetWeight208gDimensions90*93*45mmInstallationSurface mounted with screwFeatures1.Resetable design,obvious indicators around the edges of the unit.2.Press the pressing plate to enable the output function.3.Pressing plate with status (green and red) shown.4.Reversionary key with non-slip design.5.Input power range from DC12-24V to connect with all types of alarm system.6.Built-in buzzer status to set as silent,interval wailing or continuous wailing Volumeis adjustable.7.Easy to assemble,outer case without screws,3 set of output points to connect other equipment,embedded or surface installations to select.Note: only has output point function.
Product introduction:This products name manual pull station,also name fire alarm pull station,it is used to manually transmitfire alarm signal, it provides contact closure to activate emergency equipment, audible and visual signals, and alarm panels.Fire alarm pull station is an active fire protection device, usually wall-mounted, that, when activated, initiates an alarmon a fire alarm system. In its simplest form, the user activates the alarm by pulling the handle down, which completes a circuit and locks the handle in the activated position, sending an alarm to the fire alarm controlpanel. After operation, some fire alarm pull stations must be restored to the ready position using a special tool or key in order to deactivate the alarm sequence and return the system to normal.Details introduction:1.The manual pull station provide a textured finger-hold area that includes Braille text. In addition toPUSH IN and PULL DOWN text, there are arrows indicating how to operate the station, provided for non-English-speaking people.2.Pushing in and then pulling down on the handle activates the normally-open alarm switch. Once latched in the down position , the word" ACTIVATED" appears at the top in bright yellow,with a portion of the handle protruding at the bottom as a visible flag.3.Resetting the station is simple: insert the key, twist one quarter-turn, then open the station's front cover, causing the spring-loaded operation handle to return to its originalposition. The alarm switch can then be reset to its normal(non-alarm) position manually(by hand) or by closing the station's front cover, which automatically resets the switch.Package:1 x Fire alarm call point2 x Keys1 x English manualSpecification:Product NameManual Call PointRated voltage24VDCRated current45mAQuiescent current .5mAAlarm current 2.3mAContact resistance100mWStarting parts typeReusableStarting modeManual pull down plateReset modeKey resetWeight225gDimensions105*140*45mmInstallation
Product introduce:1. When the accident happens, press the plastic elements to alarm or open the door. Plastic elements had printing a indication.2. There are four colors, red, yellow, white, green.* The red used for FIRE fighting.* The white and green can be used for the access control system, emergency safety door.* The yellow is generally a warning function and an emergency rescue for natural disasters.Specifications:Product nameManual Call Point,Emergency door releaseBrand nameYIXINModelYX-BP560STypeGlass breakOperating voltage12-220VDCOperating current5AWithstood-voltage250VACContact modeNO/NCPoleSingle/Double pole optionalColorRed/Green/Yellow/Blue/White optionalBreaked materialPlastic filmCoverWith water-proof cover optionalDimension87*87*52mmWarranty1 YearProduct Feature:1.The manual call point use plastic sheet which can reused.2.Adopt plastic film instead of glass to avoid cutting the hand when alarm.3.The shape is rugged and durable,the shell is made of fire retardant materials, and the product components are resistant to high temperature and shock resistance.It is special design for fire alarm control panel and security alarm system.
Model: RTU5023 Name: GSM SMS Temperature Humidity Alarm Keyword: GSM Temperature Alarm, SMS Temperature Alarm, Temperature SMS Alarm, Temperature Alarm, Remote Temperature Monitoring, Remote Temperature Alert.Temperature Monitor, Temperature Sensor with SMS Alarm, SMS Temperature Monitoring.Humidity Alarm, Humidity SMS Notification, GSM Environment Alarm. The GSM SMS Environment Alarm is special for remotely monitoring onsite temperature, humidity, power status through wireless GSM Network. When the temperature, humidity, power voltage exceed high threshold or low threshold value, will send SMS alert to upto 10 preset mobile phone immediately. Just dial from Authorized User number, the GSM Environment Alarm will reject at the first ??Ring?�, no communication cost, and then return the current temperature, humidity, power status or voltage. Moreover, it can report onsite environment interval or daily. The GSM Environment Alarm can be used for solar power monitoring, DC power voltage monitoring, temperature monitoring, humidity monitoring, Class Room, Public Room, Waiting Room, Hospital, Stations, Fresh Food Warehouse, Office, Meeting Room, Laboratory, Library and anywhere that need monitoring temperature or control temperature in expected range. Mainly Features : 1. Can be operated from anywhere, no distance limitation; 2. No call charges for inquiry. the GSM Environment Alarm rejects the call from authorized number then return onsite temperature, humidity, and power voltage on the first 'ring'; 3. Multiple applications. (temperature, humidity, power status, solar panel, dc voltage); 4. Up to 10 authorized phone numbers, 5 can be used to receive call or SMS,and 5 can be used to call and SMS while alarm occurrence; 5.One Temperature & Humidity sensor input, measures temperatures from -40-80°C,0.5°C accuracy, Relative Humidity from 0-99RH%, accuracy is 3%; 6.External AC Power status monitoring, AC On/OFF will send SMS to authorized phone numbers; 7.Inbuilt MCU monitoring the DC input Voltage value, measure range is 9-24VDC, no need additional sensor to save cost; 8.Timer Report??Can setup every x hours automatically send its status/Value to the authorized numbers; 9.Support remotely read historic data via SMS; 10.Rechargeable Backup Battery inside can last 8hours; 11.Secure - Using caller ID and password for identification, unknown callers are ignored; 12.Programmable by SMS Commands or APPs with password protection; 13.Based on GSM Network, applied to many applications.
Model: s150 Name: gsm gprs 3g 4g sms controller alarm Keyword: Gsm gprs 3g 4g sms controller, gsm gprs 3g 4g sms alarm, gsm gprs 3g 4g rtu, gsm gprs 3g 4g sms rtu, gsm gprs 3g 4g remote controller, gsm gprs 3g 4g sms remote, gsm gprs 3g 4g relay, gsm gprs 3g 4g switch. Gsm gprs 3g 4g pump monitoring. The gsm 3g 4g sms controller alarm is special for remote switch on/off machine, equipments, and also it supports digital inputs for different detectors like water level detectors, pir motion detectors and so on. One of the advantages of them is when the inputs recovery can alert by sms, and with one interlock relay output, one sms command switch on/off relay output. When alarm occurrence, will send definition sms text and dial the user mobile phones. Mainly features: 1.Gsm frequency: 850/900/1800/1900mhz; 2.1 independent output relay (240vac3a) can be switched on/off by sending a sms text; 3.1 alarm-link output relay (240vac3a) can be switch on 0-120minutes if controller unit triggered; 4. 2/4/8 alarm logic digital inputs, nc or no and eol is optional; 5.3 sms alert numbers and 5 alarm dial telephone numbers can accept to the alarm message; 6.Two-way voice communication by external microphone and speaker; 7.Supports armed, disarmed, inquiry status, switch on/off output relay by sms commands; 8.Password protected, prevents unauthorized user; 9.Can be set up and programmed from pc configurator by usb cable; 10.Time stamped alarm messages. 11.Backup rechargeable battery inside, can work for 24hours when ac power goes off. 12.Can be operated from anywhere, no distance limit; 13.Based on gsm network, applied to many applications.
Sc05e smoke and co alarm key features: * smoke & carbon monoxide dual detection * advanced photoelectric sensor, mcu auto-processing technology * strong anti-interference ability * distinctive smoke & co alarm sounds * low battery warning * auto-check malfunction in smoke chamber * test/silent button * dustproof, mothproof, shockproof & anti-visible light Sc05e smoke and co alarm specifications: * sensor type: photoelectric * alarm sound: >85db (3m) * power supply: dc 3v lithium battery (included) * power supply life: 5 years * alarm current:
Main features: power supply: 12V ± 3V DC quiescent current: 115db harness: 50cm long parts: main controller 1pc, key fob 2pcs, LED indicator 1pc Functions: 1. auto arm/lock 2. auto disarm/unlock 3. remote engine start 4. remote engine stop 5. bike searching 6. anti-hijack 7. silence mode 8. 0.5km signal transmit -
Main feature: 1.GSM 850/900/1800/1900MHZ for Global use. 2.With 2 wired and 88 wireless zones for connecting wired/wireless sensors 3.wireless transmission control 8 road electric switch 4.Full touch keys, TFT display, beautiful shape, external connect entrance guard 5.With APP and Andriod system to remote control the alarm . 6.SMS and Call 5 phones automatically while alarming and drive wiretap, Can clearly hear the voice. 7.Auto-dial 1 preset phone numbers of Alarm Center 8.record function: Maximum recording time:20S 9.voice function:support play the user record voice 10.Talkback Function: can speak with field person 11.SMS alert & auto-dial alert when AC Power outage, AC power recovered 12.Support 7 kinds arm/disarm mode: remote/Mainframe keyboard/sms/remote call/ timing arm and disarm / alarm center software/APP mobile phone 13.Alarm panel with LCD display & keypad, easy to operate. 14.with standby rechargeable battery. The host automatically stores system status, while its power is off. 15.With wired MIC interface, switching the sound off and siren 16.Delay alarm function(0-90 optional) 17.Arming timing function(0-90 optional) 18.Timing arm/disarm function. 19.Built-in high standard Internal Antenna with strong signal 20. Chinese/English switch supported 21.with ROHS/CE/FCC certifications,conform to 3C Safety Standard and GB12663-2001 government stand Technical parameters 1.GSM frequency: 850/900/1800/1900MHZ 2.Working frequency between detector and alarm host(315M/433M optional) Wireless distance :100-200m(without obstacles) 3. Alarm response time8S(GSM in normality) 4.99 Wireless guarding zones; 5.Working conditions Operating temperature: -45~+60°C Humidity: 95% 6.Standby current:5mA 7.Alarm current: