1. Bit Breakers The Bit Breakers are suitable to make up or break out the drilling bit during the oil well drilling and repairing operations. The Users should be chosen the bit breaker according to the size and model of the drilling bit. Feature:Improve support and retention Advantage:Manage the magnitude cutter loading and bit torque Benefit:Improved bit durability and directional responsiveness Advantage:Higher nozzle counts and/or fixed ports to best serve cleaning,cooling and cuttings evacuation requirements with available hydraulic flows.Allow for higher flow rates with minimal increase in pump pressure. 2. Detailed introduction to Bit breaker 1) Bit breaker is mainly used to screw on or off a rock bit to the bottom of drill string. 2) It can also prevent the rock bit from dropping into well hole. 3) The price of it is cheap and the use of it is safety and reliable. 4) It is easy to operate. First, the bit breaker is placed on well hole and then put the rock bit onto it. Turn it to screw on or off the bit by turnplate.
Automatic circuit breaker tester UPA-3 is designed for testing and ampere-second characterization of automatic AC current circuit breakers. The device allows registering the value of the supplied current and timing the automatic circuit breaker switching interval. Circuit breaker tester UPA-3 is a mobile device, which could be easily transported to a required testing location. Circuit breaker tester UPA-3 operates on the principle of varying the power in the primary circuit of the matching power transformer and, respectively, varying the output current, flowing through the automatic circuit breaker under the test. Power regulation could be done either through an external regulator (RNO or VR) or through a built-in thyristor controller.
Cw magnetron glcwm-100l(t) Glcwm-100l is fixed-frequency cw magnetron, mainly used in microwave heating and plasma generators. Glcwm-100l has the following features: Metal ceramic structure, good strength, suitable for industrial application Special cathode, insurance of long life Special device for the internal cathode terminal, minimize the microwave leakage. Operating frequency : 915mhz minimum output : 100kw
SH200 Miniature Circuit Breaker Resin Type, ,Sh200 Mcb
Juki 2060 ejector 40001266 c-0023-mcx mps-v8 v8x-ag-0.3b-ju Juki ke700 ke2000 fx-1 fx-1r Juki ke2010/2020/2030 cpu board acp-122j pn: e9656729000 e96567290a0 Juki ke2050/2060 cpu board acp-128j acp-125j n:40044475 40003280 Juki ke2010/2020/2030 laser card ke2050/2060/fx-1r mcm 4shaft pn: e9609729000 e9610729000 Juki ke2060 right head laser card 9610729000 mcm 1 shaft Juki ke2050/2060 xmp board xmp-synqnet-cpci-dual p/n:40003259 Juki ke2050/2060 zt rmb-sti-synqnet-4 p/n:40003320 Juki 2060 ejector 40001266 c-0023-mcx mps-v8 v8x-ag-0.3b-ju Juki fx-1/r base-feeder pcb p/n:40007370 Juki ke2010 base-feeder e86027290a0 Juki ke2010 safty board e86017290a0
High efficiency high flux density carbon infrared heating lampscarbon medium wave infrared lamps features: wavelength range of carbon red heating ir heater: 2.5-2.7 um. cross sectionof carbon red heating ir heater: 33*15mm twin tube diameter.Applied industry: printing painting drying, powder coating drying, paint drying, plastic heating and drying, thin film strecthing, etc.Carbon red heating ir heater model cfir332620wlamp model: cfir332620wquartz tube: white coatinglamp length: 2620mmactive length:2500mmvolatge:400vpower: 6250wcable length: 500mm one side outcolor temperature: 1800-2400kwavelength of ir radiation: 2.5-2.7umcarbon red heating ir heatermax heated length 3200mmmax total length 3400mm;max power output: 9000-12000w;max voltage: 600v;average lifetime of carbon red heating ir heater: 10, 000 hourspart no. voltagewattagetwin tubetotal
transparent high purity quartz heater tube transparent high purity quartz heater tube is one of infrared heating element, which is the most efficient and mostenergy-saving type in the heating area. It can not only improve your heating speed by higher power, but also it will help you save more enrgy by using the shortwave infrared heater to replace the other heaters. transparent high purity quartz heater tubelamp model: swir-10500tube coating: golden reflectorlamp length: 500mmactive length: 440mmvolatge: 220vpower: 800wcable length: 600mmcolor temperature: 2000-2700kwavelength of infrared radiation: 0.75-1.4um ir benefits and features long lifemore than 5000h high speedwithin 1 second to switch onhigh efficiencymore than 85% heat efficiency of full powerhigh power densityup to 200w/cmhigh control abilityneither ballast nor special circuits are necessary for basic usageno air droughtsbecause of radiation(like solar energy)clean and odorlessno risk of contamination over environment or target object to be heatedextensive assortmentmany types of voltage, wattage, length, base, cables, horizontal
Ishcanto ixd47-63 series miniature circuit breaker is made of plastic shell, operating mechanism, contact arc system, tripping mechanisum and other components. The shell is made of high-strength special plastic, with strong impact capability and light wieght. Feature: short circuit protection Isolation function Overload protection Control
Product Description : Modular Circuit Breakers - xC60. Breaking Capacity as per IEC 60947-2, Icn = 15kA, upto 40A, Higher Installation Life : Energy limitation class: 3, Tropicalization: T2 - relative humidity 95% at 55C. Higher performance by Low cost : Cascading. Increase system continuty : Discrimination. Reference Temperature of 50C as per IEC60947-2. Product Specification: Brand - Schneider Model Name - A9N2P01C Current Rating - 1A Pole - Two Pole Rated operational voltage - 100V - 125V DC, 240V AC 50/60 Hz, 380V - 415V AC 50/60 Hz Rated service breaking capacity - 6kA conforming to EN/IEC 60947-2, 100V - 125V DC, 7.5kA conforming to EN/IEC 60947-2. 380V - 415V AC 50/60Hz Curve code - C Nominal Frequency - 50Hz / 60Hz Mounting Type - Clip-on Weight (in kg) - 0.250 Warranty - 2yr (on manufacturing defect)
Printed circuit assembly in china, 6layer board with immersion tin finished 1. Pcb p / n: 8698 2. Material: fr-4 3. Layer: 6l 4. Board thk: 2.Mm 5. Copper thk: 35um 6. Smallest hole size: 0.25mm 7. No. Of holes (pcs): 365 8. Line w / s: 5 / 4mil 9. Impedance control. Y / n (tol%): y 10. Surface: immersion tin 11. Solder mask silkscreen: white 12. Single board size: dim x (mm): 129; dim y (mm): 298 13. Special: hi-tech multilayer circuit boards with components assembly 14. Routing / punching: cn
Advantage products Allen bradley 1756-l62, 1756-l63, 1746, 1747, 1756, 1769, 1794, 2711p.. Schneider 140cpu43412u, 140cpu65150, 140cpu65160, 140cpu, noe, cra, cps, bmx, tcse.... Abb Dsqc(07kt98 wt98, 07kt97 wt97, dsqc679, imasi23, imdso14...) Bently nevada 3500/42m, 3500/22m, 3500/95.3500/15... Hima F3330, f3236, f6217, f7126, f8621aesd Triconex 3805e, 3008, 3504e, 3624, 3700a, 3721, 4351b, 4119a.. Siemens moore 6es7(1.2.3.4), 6es5, 6dd, 6dp. Ge Ic693cpu363, ic697pwr711, ic693cpu364, , ic693, ic6 , 97, ic695, is200, is215, ds200... Westinghouse/ , ovation 1c31194g01, 1c31197g01, 5x00106g01, 1c , 31125g02 ... Foxboro Fcp270, fbm203, fbm204, fbm217, , fmb231
Advantage products, Allen bradley 1756-l62, 1756-l63, 1746, 1747, 1756, 1769, 1794, 2711p.. Schneider 140cpu43412u, 140cpu65150, 140cpu65160, 140cpu, noe, cra, cps, bmx, tcse.... Abb Dsqc(07kt98 wt98, 07kt97 wt97, dsqc679, imasi23, imdso14...) Bently nevada 3500/42m, 3500/22m, 3500/95.3500/15... Hima F3330, f3236, f6217, f7126, f8621aesd. Triconex 3805e, 3008, 3504e, 3624, 3700a, 3721, 4351b, 4119a. Siemens moore 6es7(1.2.3.4), 6es5, 6dd, 6dp. Ge Ic693cpu363, ic697pwr711, ic693cpu364, , ic693, ic6 , 97, ic695, is200, is215, ds200... Westinghouse/ , ovation 1c31194g01, 1c31197g01, 5x00106g01, 1c , 31125g02 ... Foxboro Fcp270, fbm203, fbm204, fbm217, , fmb231
Miniature circuit breakers protect installations against overload and short-circuit, warranting reliability and safety for operations. They have two different tripping mechanisms, the delayed thermal tripping mechanism for overload protection and the magnetic tripping mechanism for short circuit protection. ï?? Extra-wide and complete range of MCBs to cover most applications and markets ï?? Meeting worldwide standards ï?? Certificates, documentation, training or background information to support customers due to their daily work ï?? Space and time saving thanks to frame degree updates Main features MCB range offer the possibility to select among different characteristics (B, C, D), configurations (1P, 1P+N, 2P, 3P, 3P+N, 4P), breaking capacities (up to 15 kA) and rated currents (up to 125A). Compliance to the worldwide standards, IEC/EN 60898-1 IEC/EN 60947-2 IEC/EN 60947-3 IEC/EN 61009-1 GB10963.1 GB1096.1 GB14048.2 GB14048.3 GB16917.1 Allowing the use for residential, commercial and industrial applications 25 mm2 and 10 mm2 cylinder lift twin terminals for challenging industrial use. Cross Real contact position indication, directly connected to the moving contact, for more comfort and safety ï?? Environmental Ambient Air Temperature: Operation -5 ... +55°C Storage -40 ... +70 °C Resistance to Shock acc. to IEC 60068-2-27: 30g / 2 shocks / 13 ms Resistance to Vibrations acc. to IEC 60068-2-6: 5g, 20 cycles at 5 ... 150 ... 5 Hz Environmental Conditions: 28 cycles with 55 °C / 90-96 % and 25 °C / 95-100 % Technical Standards: IEC/EN 60898-1 Rated Current (In): 6A, 10A,16A, 20A, 25A, 32A, 40A, 50A, 63A, 80A, 125A Rated Operational Voltage: acc. to IEC 60898-1 230 V AC & 400V AC Rated Insulation Voltage (Ui): acc. to IEC/EN 60664-1 440 V Rated Frequency (f): 50 Hz 60 Hz Rated Ultimate Short-Circuit Breaking Capacity (Icu): (230V AC & 400V AC) 15 kA Rated Service Short-Circuit Breaking Capacity (Ics): (230V AC & 400V AC) 6 kA Instantaneous release: Type C: Lighting protection ; Type D: Motor protection
Mcb range offer the possibility to select among different characteristics (b, c, d), configurations (1p, 1p+n, 2p, 3p, 3p+n, 4p), breaking capacities (up to 15 ka) and rated currents (up to 125a).
1. General VS1 12KV vacuum circuit breaker VCB HVD1-12(VS1-12) type indoor AC HV vacuum circuit breaker VCB (hereinafter referred to as circuit breaker) are suitable for 12kV air-insulated indoor switchgears, used as protection and control unit of power equipment of industrial& mining enterprise. Due to the super excellence, it is especially for location where requires the frequent operation of rated working current or multi breaking short circuit current. The circuit breaker adopts the integrated design of operating mechanism and circuit breaker body, servers as not only fixed installation, but also the handcart unit through equipping with a special propelling mechanism. 2. Service conditions 3.1 Environment temperature:-15degree~+40degree; 3.2 Environment humidity: Daily average relative humidity:
1. Introduction HVD7 33KV 36kv outdoor HV AC vacuum circuit breaker VCB has many visual advantages like reasonable design, fashionable appearance, high safety and reliability, simple maintenance, long electric life. It is the ideal upgraded products of 35KV outdoor oil circuit breakers. HVD7-40.5 vacuum circuit breaker is applicable for three-phase power system of AC 50HZ.It is used to make and break the load current ,overload current and short-circuit current. 2. Applicable environment 3.1The ambient temperature should be -30degree~ +40degree(-40degree in the frosty area); 3.2Altitude should not exceed 2000m(over 2000m is plateau type); 3.3The wind pressure should not exceed 700Pa(equal to wind speed 34m/s); 3.4Air pollution degree: 3,that of antifouling type:4; 3.5The installation site should be free from the fire, explosion, chemical corrosion and serious vibration. 1. Main technical parameters Rated voltage: 33kv 36KV 1 minute power frequency withstand voltage, dry test: 95 kv 1 minute power frequency withstand voltage, wet test: 80 kv Lightning impulse withstand voltage(peak value): 185 kv Rated current: 1600A / 2000A Rated short-circuit breaking current: 20KA, 25KA, 31.5KA Rated short-circuit making current(peak): 50KA, 63KA, 80KA Rated operating sequence: O-0.3s-CO-180s-CO Rated short-time withstand current: 20KA, 25KA, 31.5KA Rated peak withstand current: 50KA, 63KA, 80KA Rated short-circuit duration: 4 s Rated control voltage: AC220,110;DC220,110 Rated short-circuit breaking current break times: 20 times Full-break time:
1. General HVD32 ZW32 This vacuum circuit breaker VCB is three-phase AC 50Hz, rated voltage 12 kV outdoor high voltage switch equipment. It is mainly used to opening(closing) load current, overload current and short-circuit current. It is suitable to protect or control the city or village electrical power distribution system. 2 . Main technical parameter Rated voltage: 12 kv 1 minute rated power frequency withstand voltage: Phase to Phase, to Ground 42 kv / Fracture 48 kv Rated current: 630A / 1250A Rated short circuit breaking current: 12.5KA, 16KA, 20KA / 25KA Rated short-circuit current (peak): 31.5KA, 40KA, 50KA / 63KA Rated peak withstand current: 31.5KA, 40KA, 50KA / 63KA 4s rated short time withstand current: 12.5KA, 16KA, 20KA / 25KA Rated operating sequence: O-0.3s-CO-180s-CO(Electric operation) Closing time: 30-60 ms Opening time: 20-40 ms Rated short circuit breaking current breaking times: 30 times Mechanical life: 10,000 times Secondary circuit 1 minute power frequency withstand voltage: 2000 v Energy storage motor rated power: 40 w Energy storage motor rated voltage V: DC220/110 Rated closing operation voltage v: DC220/110, AC220/110 Rated switching operation voltage v: DC220/110, AC220/110 Electric energy storage time: =8 s
1.General HVD85 ZN85 33kv 36KV indoor vacuum circuit breaker VCB is suitable for three-phase AC power system of 50Hz and 36kV, used to make and break the load current, overload current and fault current in industrial and mining enterprises, power plants and transformer substations, meanwhile, it is suitable for the occasion where the frequent operation is required. 2. Service conditions 2.1The ambient air temperature should be -15?~40?, the daily average temperature should not exceed 35?. 2.2 Daily mean relative humidity should not exceed 95%, and the daily mean vapor pressure should not exceed 2.2kPa; the monthly mean relative humidity should not be higher than 90%, and the monthly mean vapor pressure should not exceed 1.8kPa. 2.3 Altitude: Not exceed 1,000m. 2.4 The ambient air should be free from the dust, smoke, corrosive and flammable gas, steam, salt fog, et… Main specifications and technical parameters Rated voltage: 33KV 36kv Power frequency withstand voltage: 95 kv Lighting impulse withstand voltage: 185 kv Rated current: 1250A, 1600A, 2000A Rated short-time withstand current: 25KA, 31.5KA Rated peak value withstand current: 63KA, 80KA Rated short-circuit duration: 4 s Rated short-circuit breaking current: 25KA, 31.5KA Rated short-circuit making current: 63KA, 80KA Rated operation sequence: O-0.3s-CO-180s-CO Breaking time:
"!!! Specific price, Size, Weight Are subject to Inquiry!!!" Competitive brands:&�©|160;rexroth, HAGGLUNDS, AVENTICS, Danfoss, Parker, MOOG, sunhydraforce, EOWARDS, Leybold, INFICON ,NSK and other European and American brands.
NW12N13PEF2.0E Air Circuit Breaker Masterpact NW12N1: 1250 A, 3 poles, fixed trip unit and Motorized