FYSeries current and voltage Transformer Load Box is specially provided for various payloads when testing current and voltage transformers and it is an ideal matching product for various transformer verification devices.The Transformer Load Box is in strict accordance with the national standard jjg313-94 JJG314-94 design for.Its Transformer Load Box output capacity is large Full range of loads in light weight good-looking appearance Stability and other advantages. Product nickname Transformer Load Box Voltage Transformer Load Box Current Transformer Load Box Voltage load box Current load box Voltage load box Current load box
HJ series standard voltage transformers are designed and manufactured for the actual needs of basic power supply and production departments.This product has the advantages of compact structure small size light weight easy to carry and easy to operate without maintenance etc. This product is especially suitable for field use and can also be used as standard voltage transformer and test transformer in laboratory. Product nickname, Precision voltage transformer, Calibration voltage transformer Calibrating voltage transformer Standard voltage transformer for calibration PTstandard standardPT High precision voltage transformer high precisionPT
product features Product Characteristics 1 This Series Standard Current Transformer consists of primary winding Secondary winding composition 2 Check according to the standard current ratio indicated on the nameplate 3 This Series Standard Current Transformer can be used5/5or1/1The current is self-correcting 4 With casters for easy handling Product Parameter Product Parameters technical parameters service conditions temperature 5+40 humidity 80% The workplace should not have strong external electromagnetic fields unrelated to work Allow long service at rated current boundary dimension HL-22/23 370*170*440mm3 HL-32/33 330*190*430mm3 HL-53/62/63/(HL-62C/63C 470*230*570mm3 weight HL-22/23 13kg
Product brief introduction Product Introduction FYSeries current and voltage Transformer Load Box is specially provided for various payloads when testing current and voltage transformers and it is an ideal matching product for various transformer verification devices.The Transformer Load Box is in strict accordance with the national standard jjg313-94 JJG314-94 design for.Its Transformer Load Box output capacity is large Full range of loads in light weight-looking appearance Stability and other advantages.
product brief introduction Product Introduction HJ series standard voltage transformers are designed and manufactured for the actual needs of basic power supply and production departments.This product has the advantages of compact structure small size light weight easy to carry and easy to operate without maintenance etc. This product is especially suitable for field use and can also be used as standard voltage transformer and test transformer in laboratory. Product nickname voltage transformer Calibration voltage transformer voltage transformer Standard voltage transformer for calibration PTstandard standardPT High precision voltage transformer high precisionPT
product features Product Characteristics 1 This Series Standard Current Transformer consists of primary winding Secondary winding composition 2 Check according to standard current ratio indicated on nameplate 3 This Series Standard Current Transformer can be used5/5or1/1The current is self-correcting 4 With casters for easy handling Product Parameter Product Parameters technical parameters service conditions temperature 5+40 humidity 80% The workplace should not have strong external electromagnetic fields unrelated to work Allow long service at rated current boundary dimension HL-22/23 370*170*440mm3 HL-32/33 330*190*430mm3 HL-53/62/63 (HL-62C/63C 470*230*570mm3 weight HL-22/23 13kg
Transformer winding deformation test instrument based on the measurement of the characteristic parameters of transformer internal winding the internal fault frequency response analysis (FRA) method which is being developed in developed countries is adopted to make an accurate judgment of transformer internal fault. After the design and manufacture of transformer is completed the line coil and internal structure are determined. Therefore for a multi-winding transformer line coil if the voltage grade is the same and the winding method is the same the corresponding parameters (Ci Li) of each line coil should be determined. Therefore the frequency domain characteristic response of each line coil is determined accordingly and the frequency spectrum of the corresponding three-phase line coil is comparable to some extent. The distribution parameters of transformer windings will change when short-circuit between turns and phases occurs in the test process or collision occurs in the transportation process resulting in the relative displacement of the line coil and the deformation of the line coil caused by electromagnetic tension in the short-circuit and fault state during the operation process. Then it influences and changes the original frequency domain characteristics of the transformer that is amplitude change of frequency response and resonance frequency offset. The transformer winding test instrument developed according to the response analysis method is such a novel non-destructive testing equipment for transformer internal faults. It is suitable for the internal structure fault detection of 63kV ~ 500kV power transformer. product names Electric power transformer winding deformation test instrument Transformer winding deformation detector Transformer winding deformation meterTransformer winding deformation analyzer
Product Introduction This product is specially used for measuring the capacity of distribution power transformer measuring the no-load and short-circuit loss of transformer and has the function of harmonic analysis which is convenient for analyzing the quality of on-site power network. The device can automatically check whether the wiring is correct and display the vector diagram of the three-phase current and voltage when testing the three-phase transformer. At the same time necessary correction (such as waveform correction temperature correction unrated voltage correction calibration unrated current correction) is introduced to make the test results more accurate. Product name Transformer capacity test instrument transformer capacity load tester
Dc resistancetest around group is an indispensable test project of transformer after the submission of pick up overhaul and change of subpick up switch. In general using traditional methods (bridge method and pressure drop method) measurement transformer winding group and dc resistance of large power inductance equipment is a time-consuming and time-consuming work. In order to change this situation shorten measurement time and reduce work burden of test personnel, our company developed Dc resistance rapid test instrument (hereinafter referred to as direct resistance instrument). It adopts new power supply technology featuring stable performance rapid measurement small size easy to use high measurement precision and good data repeatability. Measurement transformer is around the group and large power inductor dc resistance ideal equipment product names Dc resistance tachometer Transformer dc resistance test instrument. Transformer winding dc resistance test instrument. Transformer direct resistance speed meter Transformer direct resistance quick test instrument Inductive load Dc resistance tachometer Inductive load dc resistance rapid test instrument Inductive load dc resistance test instrument Dc resistance tester
TKBB-S Transformer Ratio Tester is specially designed for three- phase transformer in power system especially for transformer of type Z winding and other transformers whose zero-load current is relatively high.Transformer turns ratio test is very important in order to find out the transformer has the right ratio corresponding on its rated voltage in primary and secondary. TKBB-S is single phase, automatically test set specially designed for turns ratio, phase shift and excitation current measurements of power, distribution and instrument transformer.
The on-load tap changer is the only moving part connected with the transformer circuit so more and more attention has been paid to the detection of the on-load tap changer.In the electrical equipment handover and preventive test regulations it is required to check the action sequence of on-load tap changer measure switching time etc.This device is mainly used for measuring the transition waveform transition time transient resistance of transformer on-load tap changer three-phase synchronism etc.
product brief introduction AC hipot tester series Testing Transformer is power plants power supply bureau and research institutions and other users to do the AC voltage test basic test equipment by the standards of the State Bureau of Quality Supervision for a variety of electrical products electrical components insulation material dielectric strength test etc. the insulation level assessment of products under the provisions of the voltage insulation defects were found in the sample and measure the ability of over-voltage. AC HV Testing Transformer Classification: There are four kinds of high voltage testing transformer according to the medium points: 1. Oil-immersed high voltage transformer test: large capacity cheap convenient maintenance mainstream products. 2. Inflatable high voltage test transformer : interrupter resistance and light weight. 3. Dry type high voltage testing transformer: light weight light volume can run backward price expensive. 4. Series type high voltage testing transformer: small volume low voltage light weight easy to transport and install.
product brief introduction Product Introduction The test transformer calls the booster it is the basic test equipment used by the power station supplying and distributing the electrical power system and the scientific research unit. Which used in the insulated intension test on all kinds of electrical products electrical equipments and insulated materials testing the insulated level of products discovering the insulated objection of quizzee scaling the capacity burdened voltage AC HV Testing Transformer Classification: There are four kinds of high voltage testing transformer according to the medium points: 1. Oil-immersed high voltage transformer test: large capacity, cheap, convenient maintenance, mainstream products. 2. Inflatable high voltage test transformer : interrupter resistance, and light weight. 3. Dry type high voltage testing transformer: light weight, light volume, can run backward, price expensive. 4. Series type high voltage testing transformer: small volume, low voltage, light weight, easy to transport and install.
Product Introduction TKBB-S Transformer Ratio Tester is specially designed for three- phase transformer in power system especially for transformer of type Z winding and other transformers whose zero-load current is relatively high.Transformer turns ratio test is very important in order to find out the transformer has the right ratio corresponding on its rated voltage in primary and secondary. TKBB-S is single phase, automatically test set specially designed for turns ratio, phase shift and excitation current measurements of power, distribution and instrument transformer. The tester has wide testing range fast testing speed favorable repeatability flexible data processing convenient connection complete protection easy learning and convenient operation
The on-load tap changer is the only moving part connected with the transformer circuit so more and more attention has been paid to the detection of the on-load tap changer.In the electrical equipment handover and preventive test regulations it is required to check the action sequence of on-load tap changer measure switching time etc.This device is mainly used for measuring the transition waveform transition time transient resistance of transformer on-load tap changer three-phase synchronism etc. product names On - load tap - changer tester transformer on - load tap - changer tester transformer on - load switch tester
Place of Origin Xianning, Hubei, China Brand Name Fengyuan Model Type LZZBJ9-36/250W1G1 Usage Metering, Measurement and Relay Protection Applicable Temperature -5~40ºC Packaging Details Standard Export Packing Box Altitude No More Than 1000 Meters
Product description Transformer Standard current transformer are also called precision current transformers, current transformer standards, standard CT and current transformer standards. Transformer standards are divided into current transformer standards and voltage transformer standards. Standard current transformers are used in the error test of transformers. Used as a current transformer calibration standard technical parameter 1. Temperature: 2. Relative humidity 3. Rated Primary Current:5-5000A 5A,1A 4.Rated secondary current:5 1A 5 Accuracy Class 0.05S 6. Allow long-term work under the rated current; More than120A across the core. Precautions: 1. The current of standard CT and tested CT must be the same in CT calibration. 2. Follow the given wiring diagram strictly. 3. Test whether the load box is accurate or not before calibrating the transformer. 4. Forbid secondary winding opening during the calibration. 5. Select demagnetization before calibration.The wiring diagram is shown in figure 5. Short out the secondary winding before cutting off the power when the demagnetization is finished. 6.Principle wiring diagram of CT with large current generator is similar to above diagram. They are the same except the output winding of large current generator and primary winding of transformer are the same one.
Product Introduction Capacitive voltage transformer (CVT) in calibration the test must be conducted under the condition of 50Hz frequency complex geographical condition on site at the same time the traditional experiment device is difficult to meet the requirements of on-site handling testing series resonance booster device is first used in domestic field tunable resonance device has been widely used in domestic 500 kv and below the field calibration of capacitor voltage transformer. Product Parameters Technical parameters Rated Capacity 80kVA rated voltage 160kV Adjustable inductance range 65~130H Rated frequency 50Hz Rated current 0.5A Adjustable gap range 0~300mm
Product description Transformer Standard current transformer are also called precision current transformers, current transformer standards, standard CT and current transformer standards. Transformer standards are divided into current transformer standards and voltage transformer standards. Standard current transformers are used in the error test of transformers. Used as a current transformer calibration standard technical parameter Temperature -5 40 Relative humidity 80% Rated Primary Current 5-5000A 5A,1A Rated secondary current 5A 1A Accuracy Class 0.05S Allow long-term work under the rated current; More than120A across the core. Precautions The current of standard CT and tested CT must be the same in CT calibration. Follow the given wiring diagram strictly. Test whether the load box is accurate or not before calibrating the transformer. Forbid secondary winding opening during the calibration. Select demagnetization before calibration.The wiring diagram is shown in figure 5. Short out the secondary winding before cutting off the power when the demagnetization is finished. Principle wiring diagram of CT with large current generator is similar to above diagram. They are the same except the output winding of large current generator and primary winding of transformer are the same one.
Product description Current transformer field tester was developed with high-end testing technology, large-scale electronic circuit design and accord with national related protocol . It has solved the problem of big working intensity,trival operation while on-site test of current transformer, voltage transformer. Meanwhile the product has a reliable performance,and the function is strong. Technical index Test range: 5A5A~25000A5A or 5A1A~5000A1A Tested current transformer work scope: 1% 120% Second load 2.5 VA 300VA, COS 0.8 1.0 Be tested current transformer accuracy range 1.0, 0.5, 0.5 S, 0.2 and 0.2 S Resistance, admittance measurement errors 5.0% Measurement range R 0.00 ~20.0 Y 0.000mS~100.0 mS Power consumption 20 VA Accuracy level 0.05 S level Shape dimension mm 460 L 375 W 183H Weight kg 10 Feature HCCT-H Current Transformer Field Tester with recursive method to measure current transformer error, as well as potential difference method to measure voltage transformer error function, convenient for carrying out calibration work of field metering device. HCCT-H Current Transformer Field Tester without using Standard Current Transformer, Current Source, Load Box, Double Adjustable Control Box and Primary cable, using extremely simple test connection and operation to realize the current transformer test, greatly reduce work intensity and improve the work efficiency, convenient to carry out current transformer field test work.