HJ series standard voltage transformers are designed and manufactured for the actual needs of basic power supply and production departments.This product has the advantages of compact structure small size light weight easy to carry and easy to operate without maintenance etc. This product is especially suitable for field use and can also be used as standard voltage transformer and test transformer in laboratory.
Product nickname, Precision voltage transformer, Calibration voltage transformer Calibrating voltage transformer Standard voltage transformer for calibration PTstandard standardPT High precision voltage transformer high precisionPT
product brief introduction Product Introduction HJ series standard voltage transformers are designed and manufactured for the actual needs of basic power supply and production departments.This product has the advantages of compact structure small size light weight easy to carry and easy to operate without maintenance etc. This product is especially suitable for field use and can also be used as standard voltage transformer and test transformer in laboratory.
product brief introduction Product Introduction HJ series standard voltage transformers are designed and manufactured for the actual needs of basic power supply and production departments.This product has the advantages of compact structure small size light weight easy to carry and easy to operate without maintenance etc. This product is especially suitable for field use and can also be used as standard voltage transformer and test transformer in laboratory. Product nickname voltage transformer Calibration voltage transformer voltage transformer Standard voltage transformer for calibration PTstandard standardPT High precision voltage transformer high precisionPT
Product description Transformer Standard current transformer are also called precision current transformers, current transformer standards, standard CT and current transformer standards. Transformer standards are divided into current transformer standards and voltage transformer standards. Standard current transformers are used in the error test of transformers. Used as a current transformer calibration standard technical parameter 1. Temperature: 2. Relative humidity 3. Rated Primary Current:5-5000A 5A,1A 4.Rated secondary current:5 1A 5 Accuracy Class 0.05S 6. Allow long-term work under the rated current; More than120A across the core. Precautions: 1. The current of standard CT and tested CT must be the same in CT calibration. 2. Follow the given wiring diagram strictly. 3. Test whether the load box is accurate or not before calibrating the transformer. 4. Forbid secondary winding opening during the calibration. 5. Select demagnetization before calibration.The wiring diagram is shown in figure 5. Short out the secondary winding before cutting off the power when the demagnetization is finished. 6.Principle wiring diagram of CT with large current generator is similar to above diagram. They are the same except the output winding of large current generator and primary winding of transformer are the same one.
Spec: Voltage Transformer (Brand: M/S Tianshui Changkai) IL: 12/45/75kV 1Kw, 50Hz, 1.9Un:8h
Tianjin New Ventech Electronic co.,LTD was established in 1993, which is a professional China manufacturer on variety electronic transformer including coil inductors, PCB mount transformer, toroidal transformer ,high voltage transformer etc. Now we have more than 800 staff, in which there are nearly 60 technical engineers, and 80% have more than 20 years experiences. With continuous hard work, our r&d department researched 8-10 kinds new products averagely every year, and now we have strength to custom-made as per your demand.Our products include: 1.Toroidal transformer 2.PCB mount transformer 3.Common mode choke. 4. Switching transformers 5.low frequency transformer 6.high frequency transformer 7.high voltage transformer We are certified of RoHS, UL, CE environmental protection standard, ISO9001: 2000, ISO14001: 2004 and ect. We offers high quality products with the most competitive price. It is our company's basic of success. The operation idea of our company is do everything we can, satisfy customers'need. Under working hard in this principle, we become a popular manufacturer by customers, investors, and partner company.This site is constantly being updated. If the information you require is not shown please contact us directly. The size of the pallet is 80*120mmm carons on the pallet.
JDZX10-12 voltage transformer, epoxy resin casting and single pole insulated VT, is widely used indoor for measuring current, electric energy and protective relaying in the isolated neutral system with the frequency 50-60Hz and highest voltage for equipment 12 kV. Usage Terms J: Voltage transformer D: Single-phase Z: Casting insulation X: Residual voltage winding 10: Design No. 12: Rated voltage Main technical parameter 1. Rated primary voltage:11/kV or 10/kV etc. 2. Rated secondary voltage:100/V?110/V ? 115/V? 120/V 3. Rated voltage of residual voltage windings:100/ 3V ?110/ 3V? 115/ 3V? 120/ 3V 4. Burden power factor: cosF=0.8(lagging) 5. Standards: IEC60044-2.2003 Instrument transformers-Part2: Inductive Voltage transformers Other technical parameters pls see as follow: x1204.png Remarks: Upon request we are glad to offer transformers according to other standards or with non-standard technical specs.
Product Details The Transformer used in the power supply unit manufactured as per the UL norms. Transformer will be potted/sealed in an enclosure using Epoxy (mixture of Resin & Hardener) which ensures high reliability and efficiency. The enclosure is made up of Prime Stainless Steel material SS 304 grade (also carbon steel with powder coated enclosure can be provided on request ) Circuit breaker(25A x 4) provided for circuit protection. Block Terminals will provide the easiest way for the customer to connect the secondary tappings. Photocell and timer connected as per the customer needs Technical Details Wattage - 1200w Frequency - 50/60 Hz Pry. voltage - 120V Sec... voltages As per customer requirements Insulation class F, H Max. regulation 7.5% Dielectric 2000v, primary to secondary for 1 second. Dielectric2000v, all windings to lamination for 1 second.
Product Details The Transformer used in the power supply unit manufactured as per the UL norms. Transformer will be potted/sealed in an enclosure using Epoxy (mixture of Resin & Hardener) which ensures high reliability and efficiency. The enclosure is made up of Prime Stainless Steel material SS 304 grade (also carbon steel with powder coated enclosure can be provided on request ) Circuit breaker(25A x 3) provided for circuit protection. Block Terminals will provide the easiest way for the customer to connect the secondary tappings. Photocell and timer connected as per the customer needs Technical Details Wattage - 900w Frequency - 50/60 Hz Pry. voltage - 120V /277V Sec... voltages As per customer requirements Insulation class F, H Max. regulation 7.5% Dielectric 2000v, primary to secondary for 1 second. Dielectric 2000v, all windings to lamination for 1 second.
Product Details The Transformer used in the power supply unit manufactured as per the UL norms. Transformer will be potted/sealed in an enclosure using Epoxy (mixture of Resin & Hardener) which ensures high reliability and efficiency. The enclosure is made up of Prime Stainless Steel material SS 304 grade (also carbon steel with powder coated enclosure can be provided on request ) Circuit breaker(25A x2) provided for circuit protection. Block Terminals will provide the easiest way for the customer to connect the secondary tappings. Photocell and timer connected as per the customer needs Technical Details Wattage - 600w Frequency - 50/60 Hz Pry. voltage - 120V /277V Sec... voltages 12, 13, 14, 15V Insulation class F, H Max. regulation 10% Dielectric 2000v, primary to secondary for 1 second. Dielectric 2000v, all windings to lamination for 1 second.