Product description Single-phase electric meter field calibrator is suitable to test various types single phase meters on site and can also be used to test alternating current parameters. Feature 1. Current clamp and meter combined together, colorful and touch-screen display; 2. One AAA Li-battery can continuously working 4 hours; 3. Wide voltage, current measurement range, voltage range: 15-300V, current range: 0.05-120A; 4. Display all the measuring parameters in one screen; 5. Current clamp has automatic compensation function, 0.2% class accuracy; 6. Current clamp has automatic calibration function; 7. Integration design of the meter and clamp; 8. 16bit high accuracy AD switch 32 bit ARM processor core. 9. Automatically record and save 999 groups calibrate data; 10. Micro-multifunction optic sampler Technical index 1. Manual/automatic test inductive single phase meters; 2. Manual/automatic test electric single phase meters; 3. Measure virtual value of alternating voltage (15~300Vrms); 4. Measure virtual value of alternating current (50mA~120Arms); 5. Test parameters: active power, phase angle of voltage and current, frequency and etc; 6. Automatic store testing data, and 999 group test results can be saved.
Product description Three-phase electric energy meter calibrator is used for grid corporation of measurement and energy test center, management department of power supply bureau, national energy measurement of testing authorities, and also used to test each kind of single/three-phase kWh meter of industries and mining enterprises as well as electric meter manufacturers. Meanwhile, the calibrator also can be used as one high-precision standard power source. Technical index Electrical parameters Accuracy 0.05%, 0.1% Power Supply One Phase AC 180-265V, frequency 50/60Hz. AC Voltage Output Range(U1,U2,U3) 57.7V, 100V, 220V, 380V or 69.3V, 120V, 240V, 480V( optional) Adjustment range (0-120)%RG(1) Adjustment �neness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. Electrical parameters - continued AC Voltage Output - continued Stability 0.01%/120s Distortion 0.3% (Non-capacitive load) Output load each phase 25VA Measuring accuracy 0.05%RG AC Current Output Range(I1,I2,I3) 200mA, 1A, 5A, 20A, 100A Adjustment range (0-120)%RG Adjustment �neness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. Stability
Product description The Portable single-phase electric meter Test Equipment is used for grid corporation of measurement and energy test center, management department of power supply bureau, national energy measurement of testing authorities, and also used to test each kind of single phase kWh meter of industries and mining enterprises as well as electric meter manufacturers. Meanwhile, the calibrator also can be used as one high precision standard power source, ac voltage source and current source. Technical index Electrical parameters Accuracy class 0.05%, 0.1% Power Supply One Phase AC 100-265V, frequency 50/60Hz. AC Voltage Output Range 57.7V, 100V, 220V, 380V; max 500V Adjustment range (0-120)%RG(1) Adjustment 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. Stability 0.01%/120s Electrical parameters - continued Distortion 0.2% (Non-capacitive load) Output load max 25VA Measuring accuracy 0.05%RG
Overview Three phase phase volt-ampere meter a high precision instrument for measurement of three phase electric parameters, it can be used to measure the three phase voltage, current and phase angle, frequency, power, power factor and so on. three phase digital volt-ampere phase meter adopt high-speed Cortex M3 processor and 24 bits high-speed ADC a for measuring and calculation , A complete graphical interface, true color display with resolution of 320 240 and touch screen operation make a friendly man-machine interface. It is easy to carry Specifications TYPE MEASUREMENT RANGE UNIT ERROR RESOLUTION RATIO Voltage 1 600 V 0.5 measuring range 0.01V Current 0.001 10 A 0.5 measuring range 0.0001A active power 0.001 5000 W 0.5 reading PF 1 0.1W reactive power 0.001 5000 VAR 0.5 reading PF 0 0.1VAR apparent power 0.001 5000 VA 0.5 reading 0.1VA frequency 45 65 HZ 0.1 reading 0.01HZ phase position 0 360 2 0.1
Product Introduction This instrument is developed and designed according to the national power industry standard DL/ t506-2007 "insulation gas humidity measurement method for sulfur hexafluoride electrical equipment" and adopts the imported high-precision dew point sensor and new digital circuit control technology. It is a high-precision intelligent instrument to measure the trace moisture content in SF6 gas. This instrument adopts intelligent self-calibration technology wide measurement range fast response high accuracy good linearity dynamic display of measurement curve. At the same time the instrument also has an automatic dryer which can greatly reduce the measurement time. Product nickname intelligent micro water meter micro water meter micro quality meter.
This instrument is developed and designed according to the national power industry standard DL/ t506-2007 "insulation gas humidity measurement method for sulfur hexafluoride electrical equipment" and adopts the imported high-precision dew point sensor and new digital circuit control technology. It is a high-precision intelligent instrument to measure the trace moisture content in SF6 gas. This instrument adopts intelligent self-calibration technology wide measurement range fast response high accuracy good linearity dynamic display of measurement curve. At the same time the instrument also has an automatic dryer which can greatly reduce the measurement time. Product nickname intelligent micro water meter micro water meter micro quality meter.
1. 5 LED digitally display output by actual value or by percentage 2. AC/DC current output range: 0~100 uA ~500uA ~2mA~5mA~20mA ~50mA ~200mA ~500mA ~2A~5A~20A~30A(optional)~50A(optional) 3. AC/DC voltage output range: 0~200mV~1V~2V~5V~10V~20V~50V~100V~200V~500V~1000V 4. Three AC frequency for option: 50Hz 60 Hz 400 Hz 5. Auto protection or manual resetting function for over load 6. Over load rang is 10% for each level of voltage current 7. Clip-on transformer testing: matching with our product of standard coil measuring range AC 0~750A ( above 1000A for part of meters) DC 0~1000A error: ±0.3%
1. Design with touch panel and mask button massive information to see and simple to use 2. built-in standard energy meter for digital closed loop feedback U I F W VAR VA PF all for reference 3. Perfect over circuit over voltage. short circuit open circuit over heat over load protection 4. Three phase rated current rated voltage can be preset by users 5. Multiple choose of voltage current phase testing point 6. Capable of measuring single phase three phase active power energy meters and reactive power energy meters 7. Large memory for data storage and searching data is very convenient 8. With R232 communication interface for PC control and software upgrade
TKDL-II live cable identification instrument is used to identify A particular cable in the power cable setting migration maintenance and fault treatment to identify A cable in the cable. It has the characteristics of accurate fast simple operation and wide application. It is an indispensable testing instrument in cable construction and maintenance. The electric/uncharged cable recognition device USES single-chip microcomputer technology to encode and power the transmitting signal at the transmitting end which drives the large calibre calipers to coupling the signal to the live cable. The single chip in the receiver decodes and phase the received phase encoding signal. The target cable is identified from a large bundle of other cables based on the uniqueness of the signal phase characteristics on the target cable. It is a light compact compact lithium battery powered portable instrument. Suitable for all kinds of high and low voltage power cables. 1. Charged identification and un-charged identification function combined not only for identification and judgment of cable outage but also for the identification and judgment of live cables the operation is extremely simple very easy to use. 2. The instrument lithium battery-powered you can work continuously for 3 to 5 hours suitable for field use of passive field.
Product Introduction Digital double clamp Phase voltammeter is a high-precision low-price hand-held double-channel input measurement instrument designed for voltage current and Phase measurement on site.Using this meter the phase between u-u i-i and u-i can be easily measured in the field the phase sequence of sensitive and capacitive circuits and three-phase voltage can be distinguished the wiring group of transformers can be detected the secondary circuit and bus differential protection system can be tested the phase relationship between CT of each differential protection group can be read out and the wiring of the electricity meter can be checked.The tongs current transformer is used to input the measured current so there is no need to disconnect the measured line.When measuring the phase between u1-u2 the two input circuits are completely insulated and isolated so it completely avoids the possible short-circuit of the measured circuit caused by wrong wiring and thus burns out the measuring instrument.The display screen USES high-contrast Liquid crystal display with words up to 25mm and The screen Angle can be freely converted to about 70�° to obtain better visual effects. Digital double clamp Phase voltammeter enclosure USES engineering insulation materials another rubber vibration protection sleeve safe and reliable. Product namesï¼?Phase meter double clamp Phase meter double clamp Phase voltammeter clamp forms a table clip-on Phase voltammeter Digital Phase double clamp Phase meter Digital double clamp table low-pressure volt-ampere Phase inspection table hand-held Digital double clamp Phase voltammeter double clamp type Digital Phase meter double clamp Digital Phase meter double clamp type volt-ampere Phase meter double clamp volt-ampere Phase table double clamp Phase meter Digital display double clamp Phase voltammeter
Product Introduction 3-phase energy meter calibrator introduction: HZ-3521 handheld meter field calibrator is a measurement of electrical parameters power meter calibration wiring judged as one of the high-precision test instrument. Product Characteristics 3-phase energy meter calibrator introduction: TKSX-3 handheld meter field calibrator is a measurement of electrical parameters power meter calibration wiring judged as one of the high-precision test instrument. 3-phase energy meter calibrator technical parameters: Input feature Voltage measuring range: 0 ~ 400V 57.7V 100V 220V 400V fourth gear automatic switching range. Current measuring range: 0 ~ 5A built-in transformer into 5A (CT) files. Clamp transformer for the 5A (small pliers) 25A (small pliers) 100A (the clamp) 500A (the clamp) 400A (tongs) 2000A (tongs) six stalls. (Including medium and large Clamp Meter is optional) Phase angle measuring range: 0 ~ 359.999 Frequency Measurement Range: 45 ~ 55Hz.
Overview Three-phase phase volt-ampere meter a high precision instrument for measurement of three-phase electric parameters, it can be used to measure the three phase voltage, current and phase angle, frequency, power, power factor and so on. three-phase digital volt-ampere phase meter adopt high-speed Cortex M3 processor and 24 bits high-speed ADC a for measuring and calculation , A complete graphical interface, true color display with resolution of 320 x 240 and touch screen operation make a friendly man-machine interface. It is easy to carry
Product description: Three Phase Energy Meter Field Calibrator is a precision AC energy meter testing instrument, mainly used to test three phase energy meter error on site and measure various of AC parameters. Technical index: Electrical parameters Accuracy class 0.05%, 0.1% Resolution 6 TFT (640-480) Electrical parameters - continued Power supply 220V±10%, 50/60Hz Li-polymer battery (size (mm): 110x51x16, nominal output voltage: 7.2V, capacity: 5000mAh) Power line supply (U1, UN), 85V-265V 50/60Hz Communication port RS232 Test voltage Range 5-480V Error ±0.05% (30V-480V) ±0.1% (5V-30V) Harmonic 2nd-63st Test current Range (direct connection) 5mA-20A Error (direct connection) ±0.05% (100mA-20A) ±0.1% (10mA-100mA) Range (clamp CT) 10mA-3000A Error (camp CT) �±0.2% (100mA-100A) ±0.5% (100A-3000A) Harmonic 2nd-63st
Product description Portable Three-phase Standard Meter is a portable reference standard meter used to test three phase meters and single phase meters, it designed to work both in the and in the laboratory. Technical index Portable Three-phase Standard Meter Electrical parameters Accuracy class 0.05% Voltage supply Range 5V-480V Error Display range 5.000000V-480.0000V Harmonic 2nd-63st Range 1mA-120A Error Display range 1.000000mA-120.0000A Active power 0.05% (0.01A-0.2A) Reactive power Apparent power Active energy
Product description Portable Three-phase Standard Meter is a portable reference standard meter used to test three phase meters and single phase meters, it designed to work both in the eld and in the laboratory. Technical index Portable Three-phase Standard Meter Electrical parameters Accuracy class 0.05% Voltage supply Range 5V-480V Error Display range 5.000000V-480.0000V Harmonic 2nd-63st Range 1mA-120A Error Display range 1.000000mA-120.0000A Active power
Product description The test transformer calls the booster, it is the basic test equipment used by the power station, supplying and distributing the electrical power system and the scientific research unit. Which used in the insulated intension test on all kinds of electrical products, electrical equipments and insulated materials, testing the insulated level of products, discovering the insulated objection of quizzee, scaling the capacity burdened voltage Oil Immersed Testing Transformer 1 Technical index Model Capacity KVA High Frequency Voltage Output Voltage KV High Frequency Voltage Output Current mA) Low Frequency Voltage input Change Tempera- ture() raised/ 30 minute V A YD G -1.5 1.5 50 30 200 7.5 500 10 YD G 3 3 50 60 200 15 500 10 YD G-5 5 50 100 200 25 500 10 YD G10 10 50 200 220/380 50/26 500 10 YD G20 20 50 400 380 53 500 10 30 50 600 380 79 500 10 40 50 800 380 105 500 10 50 50 1000 380 132 500 10 100 100 100 500 263 1000 10 150 100 1500 500 300 1000 10 200 100 2000 500 400 1000 10
Overview High voltage insulation megohmmeter is composed of medium and large scale integrated circuits. This meter has large output power high short-circuit current value and large output voltage grades (there are four voltage grades). The working principle is as follows: the DC high voltage generated by the battery inside the machine as power supply and converted by DC/DC reaches the L pole from the E pole by the tested product so as to generate a current from E to L pole. After I/V conversion and operation by the divider the measured insulation resistance value is directly displayed by LCD. Technical Parameters Working Conditions environment temperature relative humidity 85%RH output voltage level 500V 1000V 2000V2500V measurement range 019990M Resolution 0.01M0.1M1.0M10.0M relative error Voltage/load 2500V/20M Voltage drop about10% short-circuit current 1.6mA direct current 81.5V(AAR6)battery alternating current 220V/50Hz Power quiescent dissipation
Product description The portable Three-phase standard power source is suitable for metering departments, power distribution terminals, power management, reactive power compensation devices and enterprise production. Technical index Electrical parameters Accuracy class 0.05%, 0.1% Power supply Single phase AC 85-265 V, frequency 50/60 Hz AC Voltage output Range (U1, U2, U3 phase) 57.7V/100V/220V/380V; range switch automatically (Max 500V) Electrical parameters - continued 0.01% RG Accuracy 0.05% RG Stability
Product description Electrical equipments in modern industrial, commercial and residential users are more sensitive to power quality, and have a higher requirement of quality of power supply. Currently, harmonics,electromagnetic interference, power factor reduction have been tied to the three hazard of the power system. When it is interfered or contaminated, grid power quality can t reach the national standards, so it has to be targeted on the grid power quality improvement. To understand the actual situation of power quality, you must have the appropriate equipment to test and analysis the actual situation. Counter the domestic condition, our company developed the professional power quality analysis instrument, which is suitable for the country. 3 phase handheld power quality analyzer Technical index 1. Input characteristics
Product description Single phase standard power supply is suitable for power department, quality control department, research units, institution of higher learning, electric energy meter, power supply management, load control, power quality, reactive power compensation device and production of the enterprise and so on. It can be as single phase voltage source, current source and power source. Electrical parameters Electrical parameters Accuracy class 0.05, 0.1 Power supply Single phase AC 85-265V, 50 60 Hz AC Voltage output Range 57.7V 100 V 220V 380V, Switch automatically max 500V Adjustment resolution 0.01, 0.1, 1 10,