1. Design with touch panel and mask button massive information to see and simple to use
2. built-in standard energy meter for digital closed loop feedback U I F W VAR VA PF all for reference
3. Perfect over circuit over voltage. short circuit open circuit over heat over load protection
4. Three phase rated current rated voltage can be preset by users
5. Multiple choose of voltage current phase testing point
6. Capable of measuring single phase three phase active power energy meters and reactive power energy meters
7. Large memory for data storage and searching data is very convenient
8. With R232 communication interface for PC control and software upgrade
Product description The portable Three-phase standard power source is suitable for metering departments, power distribution terminals, power management, reactive power compensation devices and enterprise production. Technical index Electrical parameters Accuracy class 0.05%, 0.1% Power supply Single phase AC 85-265 V, frequency 50/60 Hz AC Voltage output Range (U1, U2, U3 phase) 57.7V/100V/220V/380V; range switch automatically (Max 500V) Electrical parameters - continued 0.01% RG Accuracy 0.05% RG Stability
To set up and take the load regulation of voltage, current, phase angle, frequency and power factor, also can be used as AC current source, AC voltage source or power source. To set 2-128 times of the amplitude and phase harmonics, and it can be added to the base wave in every harmonic output. Frequency value is adjustable (AB and phase C). Voltage, current output a wide range, big power, high stability, waveform distortion degree is small. Strong with load ability, but it can take capacitive, sensibility, resistance of composite type load or load and load regulation is higher than 0.01%. To apply the 32 bit MPU + DSP + FPGA, powerful flexible. To use hardware PID, fast response, the change of load will not cause output volatility. Industrial frequency waves as high as 50000 points a week of the wave kneading, signal output without filter, precise output waveform, the harmonic output precision, harmonic distortion degree is small. Range switching automatically To use software calibration, simple operation, stable and reliable. To have big screen, 320 x 240 LCD display, Chinese or English interface, operating simply. To have perfect over-current, over-voltage, heat, a shorts-and-opens, overload protection, failure detection automatically. With RS232 interface, and PC connection To take place machine software, it can be output through the PC software program.
High accuracy class up to 0.02% High stability, high reliability Measuring 2nd~51st harmonics Metal structure, strong and reliable Waveform display function Vector diagram function Energy accumulating function Suit for testing in the lab As a three phase reference standard
Rs 1.2 Lakh / Unit Minimum Order Quantity: 1 Unit Voltage V Fuel Type Gasoline, Diesel Phase Three Phase Automation Grad Manual Frequency 60 Hz Number of Cylinder 1 Weight 920 Kg Rated Current Capacity 5000 V A (1 phase / 3 phase) We are offering Portable Power Generator to our clients
Product description Portable Three-phase Standard Meter is a portable reference standard meter used to test three phase meters and single phase meters, it designed to work both in the and in the laboratory. Technical index Portable Three-phase Standard Meter Electrical parameters Accuracy class 0.05% Voltage supply Range 5V-480V Error Display range 5.000000V-480.0000V Harmonic 2nd-63st Range 1mA-120A Error Display range 1.000000mA-120.0000A Active power 0.05% (0.01A-0.2A) Reactive power Apparent power Active energy
Product description Portable Three-phase Standard Meter is a portable reference standard meter used to test three phase meters and single phase meters, it designed to work both in the eld and in the laboratory. Technical index Portable Three-phase Standard Meter Electrical parameters Accuracy class 0.05% Voltage supply Range 5V-480V Error Display range 5.000000V-480.0000V Harmonic 2nd-63st Range 1mA-120A Error Display range 1.000000mA-120.0000A Active power
Product description Single phase standard power supply is suitable for power department, quality control department, research units, institution of higher learning, electric energy meter, power supply management, load control, power quality, reactive power compensation device and production of the enterprise and so on. It can be as single phase voltage source, current source and power source. Electrical parameters Electrical parameters Accuracy class 0.05, 0.1 Power supply Single phase AC 85-265V, 50 60 Hz AC Voltage output Range 57.7V 100 V 220V 380V, Switch automatically max 500V Adjustment resolution 0.01, 0.1, 1 10,
194Q is a high-end multifunction power analyzer manufactured by Blue Jay. higher measurement accuracy and powerful functions. With its four direct access keys and TFT displays friendly full text interface helps user operate device more easy in 3P3W or 3P4W LV installation. All monitored data is available via a digital RS485 communication port running Modbus Protocol. It can be used as a data gathering device for an intelligent Power Distribution System or Plant Automation System. Provide Harmonic measurement with multi-tariff record user can easy establish accounting standards for different time. Max 52th harmonic individual monitor let user clear grasp of the present electrical grid quality.
Product description Single-phase standard power supply is suitable for power department, quality control department, research units, institution of higher learning, electric energy meter, power supply management, load control, power quality, reactive power compensation device and production of the enterprise and so on. It can be as single phase voltage source, current source and power source. Electrical parameters Electrical parameters Accuracy class 0.05%, 0.1% Power supply Single phase AC 85-265V, 50/60 Hz AC Voltage output Range 57.7V / 100 V / 220V / 380V, Switch automatically (max 500V) Adjustment resolution 0.01%, 0.1%, 1%, 10%, AC Voltage output Range 57.7V / 100 V / 220V / 380V, Switch automatically (max Adjustment resolution 0.01%, 0.1%, 1%, 10%, Accuracy 0.05% RG Stability Better than 0.01% RG/1min Distortion degree Better than 0.1% (not capacitive load) Load capacity 40VA Full load regulation rate Less than 0.01% RG Full load regulation time Less than 1ms Temperature drift 8 PPM C Long-term stability 60 PPM/year AC Current output Range Adjustment resolution Accuracy Stability Distortion degree Load capacity Full load regulation rate Full load regulation time Temperature drift Long-term stability 0.1A / 0.25A / 0.5A / 1A / 5A / 10A / 20A / 50A / 100A, Switch automatically 0.01%, 0.1%, 1%, 10%, 0.05% RG Better than 0.01% RG/1min Better than 0.1% (not capacitive load) 40VA Less than 0.01% RG Less than 1mS 8 PPM C 60 PPM/year