Portable Three-phase Standard Meter is a portable reference standard meter used to test three phase meters and single phase meters, it designed to work both in the and in the laboratory.
Technical index
Portable Three-phase Standard Meter
Electrical parameters
Accuracy class
0.05%
Voltage supply
Range
5V-480V
Error
Display range
5.000000V-480.0000V
Harmonic
2nd-63st
Range
1mA-120A
Error
Display range
1.000000mA-120.0000A
Active power
0.05% (0.01A-0.2A)
Reactive power
Apparent power
Active energy
Product description Portable Three-phase Standard Meter is a portable reference standard meter used to test three phase meters and single phase meters, it designed to work both in the eld and in the laboratory. Technical index Portable Three-phase Standard Meter Electrical parameters Accuracy class 0.05% Voltage supply Range 5V-480V Error Display range 5.000000V-480.0000V Harmonic 2nd-63st Range 1mA-120A Error Display range 1.000000mA-120.0000A Active power
Supplier: Ethanol /alcohol process line/machine,ethanol/alcohol turnkey project , industry fruit process machine/production line ,industry vegetable process machine/production line, industry noodle machine/production line , industry bread/cake machine/process line and so on . industry waste water treatment system process line .packing machine
Services: Our company's products, technical support, training, installation and commissioning
Features: 1. Check the error of active and reactive of watt-hour meter at the same time, and meanwhile check the error of main and secondary meter in the same circuit. 2. Display the electrical constants such as: voltage, current, power, power factor, phase and frequency and etc. 3. Measure ct ratio, wave form display. 4. Measure 2-51 voltage and current harmonics. 5. Judge wrong wiring. 6. Measure the baud rate for multi-function energy meter and meter number reading. ¦ct secondary loading function. 8. Automatically correct the clamp error.
INTRODUCTION The instrument is a precision AC energy meter testing instrument, mainly used to test three phase energy meter error on site and measure various of AC parameters. TECHNICAL SPECIFICATIONS Electrical parameters Accuracy class 0.05%, 0.1% Resolution 6 TFT (640-480) Power supply 220V±10%, 50/60Hz Li-polymer battery (size (mm): 110x51x16, nominal output voltage: 7.2V, capacity: 5000mAh) Power line supply (U1, UN), 85V-265V 50/60Hz Communication port RS232 Test voltage Range 5-480V Error ±0.05% (30V-480V) ±0.1% (5V-30V) Harmonic 2nd-63st Test current Range (direct connection) 5mA-20A Error (direct connection) ±0.05% (100mA-20A) ±0.1% (10mA-100mA) Range (clamp CT) 10mA-3000A Error (camp CT) ±0.2% (100mA-100A) ±0.5% (100A-3000A) Harmonic 2nd-63st Power measure error Active power (direct connection) ±0.05% (0.1A-20A) ±0.1% (0.01A-0.1A) Reactive power (direct connection) ±0.1% (0.1A-20A) Energy measure error Active energy (direct connection) ±0.05% (0.1A-20A) ±0.1% (0.01A-0.1A) Reactive energy (direct connection) ±0.1% (0.1A-20A) Phase angle Range 0-360 Resolution 0.01 Error ±0.05 Frequency Range 45-65Hz Resolution 0.001Hz Error 0.002Hz Pulse input Input channel 2 Input level 5-24V Input frequency Max. 2MHz Pulse output Energy constant 180000imp/kWh, 1800imp/kWh, 180imp/kWh Pulse ratio 1:1 Output level 5V Function Vector diagram Yes Waveform Yes Energy accumulation Yes Communication with PC Yes Mechanical parameters Instrument dimensions (WHD) (mm) 220-13861 Instrument Weight (kg) 1.7 Carry case dimensions (WHD) (mm) 450-320185 Carry case (kg) 8.5 Environmental conditions Ambient temperature -10C to 55C Relative humidity 15%-85%
The GF302D3 portable three phase energy meter test bench consists of an integrated three phase 120A current source and 600V voltage source and a class 0.02 three phase electronic reference standard meter. The energy meter test bench is particularly designed for analysis of complete metering installations and local mains conditions. The meter test bench offers high functionality combined with an excellent menu guided operation via built-in thirty keys and colored 7" touch LCD-display. It can auto & manual test all kinds of energy meter error. Using on site or in the laboratory. It can preset a variety of test schemes for testing energy meter.
The GF302D1 three phase portable energy meter test equipment consists of an integrated three phase current source(up to 500V/120A or 500V/20A) and built-in three-phase electronic reference standard of accuracy class 0.05%. Characteristic features of the GF302D1 are its wide measuring range, high accuracy and high tolerance to unwanted external influences. The equipment offers high functionality combined with an excellent menu guided operation via built-in keyboards and colored 7" touch LCD-display. Voltage & current harmonics output from 2 to 63 times. This model portable meter test equipment can be programmable by PC, automatic generation of energy meter error test report.
The GF302D3 portable three phase energy meter test bench consists of an integrated three phase 120A current source and 600V voltage source and a class 0.02 three phase electronic reference standard meter. The energy meter test bench is particularly designed for analysis of complete metering installations and local mains conditions. The meter test bench offers high functionality combined with an excellent menu guided operation via built-in thirty keys and colored 7 touch LCD-display. It can auto & manual test all kinds of energy meter error. Using on site or in the laboratory. It can preset a variety of test schemes for testing energy meter.
The GF302D1 three phase portable energy meter test equipment consists of an integrated three phase current source(up to 500V/120A or 500V/20A) and built-in three-phase electronic reference standard of accuracy class 0.05%. Characteristic features of the GF302D1 are its wide measuring range, high accuracy and high tolerance to unwanted external influences. The equipment offers high functionality combined with an excellent menu guided operation via built-in keyboards and colored 7" touch LCD-display. Voltage & current harmonics output from 2 to 63 times. This model portable meter test equipment can be programmable by PC, automatic generation of energy meter error test report.
Electrical parameters Accuracy 0.05%, 0.1% Power Supply One Phase AC 180-265V, frequency 50/60Hz. AC Voltage Output Range(U1,U2,U3) 57.7V, 100V, 220V, 380V or 69.3V, 120V, 240V, 480V( optional) Adjustment range (0-120)%RG(1) Adjustment fineness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. Stability 0.01%/120s Distortion 0.3% (Non-capacitive load) Output load each phase 25VA Measuring accuracy 0.05%RG AC Current Output Range(I1,I2,I3) 200mA, 1A, 5A, 20A, 100A Adjustment range (0-120)%RG Adjustment fineness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. Stability