Three-phase phase volt-ampere meter a high precision instrument for measurement of three-phase electric parameters, it can be used to measure the three phase voltage, current and phase angle, frequency, power, power factor and so on.
three-phase digital volt-ampere phase meter adopt high-speed Cortex M3 processor and 24 bits high-speed ADC a for measuring and calculation , A complete graphical interface, true color display with resolution of 320 x 240 and touch screen operation make a friendly man-machine interface. It is easy to carry
Overview Three phase phase volt-ampere meter a high precision instrument for measurement of three phase electric parameters, it can be used to measure the three phase voltage, current and phase angle, frequency, power, power factor and so on. three phase digital volt-ampere phase meter adopt high-speed Cortex M3 processor and 24 bits high-speed ADC a for measuring and calculation , A complete graphical interface, true color display with resolution of 320 240 and touch screen operation make a friendly man-machine interface. It is easy to carry Specifications TYPE MEASUREMENT RANGE UNIT ERROR RESOLUTION RATIO Voltage 1 600 V 0.5 measuring range 0.01V Current 0.001 10 A 0.5 measuring range 0.0001A active power 0.001 5000 W 0.5 reading PF 1 0.1W reactive power 0.001 5000 VAR 0.5 reading PF 0 0.1VAR apparent power 0.001 5000 VA 0.5 reading 0.1VA frequency 45 65 HZ 0.1 reading 0.01HZ phase position 0 360 2 0.1
Frequency 50hz ¡¨¤2hz Outside magnetic field intensity: ¡¨¹0.025mt Warm-up: the time of warm-up: ¡y30 minutes Using condition: Environment temperature: 5¡æ¡-40¡æ Relative humidity 25%¡«85% Test current: 0.05a¡«120a Current range 1a, 10a, 100a Imax=120a Test voltage 50v¡-480v Voltage range: 50v, 100v, 200v, 400v Umax=480v Accuracy: Current: ¡¨¤0.05%rg 0.125¡«120a Voltage: ¡¨¤0.05%rg 40v¡«480v Power: Active power ¡¨¤0.05% (50v¡«480v, 0.2a¡«120a, cosØ¡y0.5) Reactive power ¡¨¤0.1% (50v¡«480v, 0.2a¡«120a) Apparent power ¡¨¤0.1% (50v¡«480v, 0.2a¡«120a) Power factor Measurement range: 0¡«¡¨¤1 Accuracy: ¡¨¤0.05%rg (cosØ¡y0.5) Phase: Measurement range: 0¡ã¡«360¡ã Accuracy: 0.05¡ã(50hz) Frequency: 0.03%rd (45hz¡«65hz) Pulse output: Ttl level Load ¡ê¾2kw High frequency output port: fh Low frequency output port: fl Affection of temperature: (5¡æ¡«40¡æ) Voltage, current and frequency: ¡¨¹¡¨¤15ppm/¡æ Power: ¡¨¹¡¨¤30ppm/¡æ Communication port: Rs232 Rs485 Power supply: Voltage: ac220v¡¨¤22v Frequency: 50hz¡¨¤2hz Power: 40va Dimension: 432mm¡¨¢131mm¡¨¢308mm Weight: 15kg
Three Phase Energy Meter with following features - Dual Source - Prepaid Function with inbuilt relays - Whole Current - Load Curtailment - Modbus/RS485 Protocol Communication - 10-60 Amps Customization as per requirement also possible
Product description Three-phase electric energy meter calibrator is used for grid corporation of measurement and energy test center, management department of power supply bureau, national energy measurement of testing authorities, and also used to test each kind of single/three-phase kWh meter of industries and mining enterprises as well as electric meter manufacturers. Meanwhile, the calibrator also can be used as one high-precision standard power source. Technical index Electrical parameters Accuracy 0.05%, 0.1% Power Supply One Phase AC 180-265V, frequency 50/60Hz. AC Voltage Output Range(U1,U2,U3) 57.7V, 100V, 220V, 380V or 69.3V, 120V, 240V, 480V( optional) Adjustment range (0-120)%RG(1) Adjustment �neness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. Electrical parameters - continued AC Voltage Output - continued Stability 0.01%/120s Distortion 0.3% (Non-capacitive load) Output load each phase 25VA Measuring accuracy 0.05%RG AC Current Output Range(I1,I2,I3) 200mA, 1A, 5A, 20A, 100A Adjustment range (0-120)%RG Adjustment �neness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. Stability
Product description Portable Three-phase Standard Meter is a portable reference standard meter used to test three phase meters and single phase meters, it designed to work both in the and in the laboratory. Technical index Portable Three-phase Standard Meter Electrical parameters Accuracy class 0.05% Voltage supply Range 5V-480V Error Display range 5.000000V-480.0000V Harmonic 2nd-63st Range 1mA-120A Error Display range 1.000000mA-120.0000A Active power 0.05% (0.01A-0.2A) Reactive power Apparent power Active energy
Product description Portable Three-phase Standard Meter is a portable reference standard meter used to test three phase meters and single phase meters, it designed to work both in the eld and in the laboratory. Technical index Portable Three-phase Standard Meter Electrical parameters Accuracy class 0.05% Voltage supply Range 5V-480V Error Display range 5.000000V-480.0000V Harmonic 2nd-63st Range 1mA-120A Error Display range 1.000000mA-120.0000A Active power
Especially developed for indication and supervision of the three-phase circuit, replaces an analogical ammeter, reducing installation manpower and optimizing the used one of spaces in the panel. Ideal for protection of three-phase networks is monitored and generally to own alarm superior and inferior. Protection of the parameters of programming by password.
Especially developed for indication and supervision of the three-phase circuit. Provide three-phase active power, reactive power, power factor measurement and display, can expand the measurement range, replaces old analogical meter, reducing installation manpower and optimizing the used one of spaces in the panel. Ideal for protection of three-phase networks is monitored and generally to own alarm superior and inferior. Protection of the parameters of programming by password.