Tetracycline residue rapid test device. 40 pcs/kit.
Detection of e. Coli o157 article qualitative detection of colloidal gold feces, food, water and other samples of e. Coli o157. The degree of color is proportional to the sample bacteria. Enrichment effect well. Can be used to treat samples in rapid screening, positive samples can be isolated bacteria, reduce the workload. Steps: 1. Will be placed on the detection of clean, dry working platform. 2. Provided with the kit with clean straw or from the pipette to take samples or enrichment sample 2 drops, drops added to the test sample by adding end section (detection section white side), start timing; 3. 2-15 minutes of observation, 15 minutes after the results do not count. [Results judge] negative: a red line appears, which appears in the control line position of a red line; positive: two red lines appear, that in the test line and control line positions are there red line; invalid: no red line appears that the test line and control line in the position not appear red. [Treatment of samples to be tested] 1. Direct detection: direct detection of water will be. 2. By bacteria detection (1) stool samples: the samples of the inoculated immediately take 1 gram of 9ml of mec broth, 37 constant temperature shaking culture 6h. (2) food samples: the 25 g samples of ground, and immediately inoculated in 225ml of mec broth, 37 constant temperature shaking culture 9h. (3) water samples: water samples will be 400ml immediately inoculated in 5 times concentrated mec 100ml in broth, 37 constant temperature shaking culture 16-20h. 3. Proposed use of enrichment broth was added 20mg / l novobiocin the ec modified broth. [Interpretation of the results] 1. Enrichment after negative results may be judged as negative. 2. Or by direct detection of bacteria have positive results, the pathogen can be isolated. 3. Negative result does not have a precise meaning. [storage] 4-30 , cool dark dry place.
Intended use: Toxoplasma igg/igm rapid test is a rapid immunochromatographic test for the simultaneous detection of igm and igg antibodies to toxoplasma gondii in human serum/plasma. The test can be used as a screening test for toxoplasma infection and as an aid for differential diagnosis of the self limiting primary toxoplasma infections and the potentially fatal secondary toxoplasma infections in conjunction with other criteria. Test principle: The toxoplasma igg/igm rapid test is a lateral flow chromatographic immunoassay. The test cassette consists of: 1) a burgundy colored conjugate pad containing toxoplasma recombinant envelope antigens conjugated with colloid gold (toxoplasma conjugates) and rabbit igg-gold conjugates, 2) a nitrocellulose membrane strip containing two test bands (t1 and t2 bands) and a control band (c band). The t1 band is pre-coated with the antibody for the detection of igm anti-toxoplasma, t2 band is coated with antibody for the detection of igg anti-toxoplasma, and the c band is pre-coated with goat anti rabbit igg. Absence of any t bands (t1 and t2) suggests a negative result. The test contains an internal control (c band) which should exhibit a burgundy colored band of the immunocomplex of goat anti rabbit igg/rabbit igg-gold conjugate regardless of the color development on any of the t bands. Otherwise, the test result is invalid and the specimen must be retested with another device. Reagents and materials supplied: 1. Test cassette individually foil pouched with a desiccant. 2. Plastic dropper 3. Buffer 4. Package insert. Storage and stability: The kit must be stored at 2-30 c. Warning and precautions: 1. For in vitro diagnostic use only. Not for medicinal use. 2. Do not use beyond expiry date. 3. Read the instructions careful y before performing the test. 4. Handle all specimen as potential y infectious. 5. Follow standard biosafety guidelines for handling and disposal of potential y infective material.
1. Intended use: The salbutamol residue rapid test card is a rapid, one step test for the qualitative detection of salbutamol in meat samples. The whole time of assay is only approx. 15~25min. 2. Summary: Salbutamol belongs to the group of G-agonists. It can promote animalí»s fat metabollism, and accelerate the growth of animal. However, this is prohibitted. Except for its lipolytic and anabolic effect, salbutamol is used as antiasthmatic and tocolytic agent which has a slacken effect on non-striated musculature. It can remain in animalí»s body and may lead to strong effect to human. If for worse, it may threaten peopleí»s life. Salbutamol is prohibitted for using in most countries. The salbutamol residue rapid test card is a rapid test to qualitatively detect the presence of salbutamol in specimen at the sensitivity of 58g/kg. The major advantage of the one step test device is that the result can be observed easily . 3. Principle: The principle is the antigen-antibody reaction. The one step test device is a competitive immunoassay of which the detector reagent consists colloidal gold particles that is coated with affinity purified anti-salbutamol antibodies. The capture reagent in the assay is salbutamol-protein conjugate, which is immobilised on the membrane of the test device. The specimen migrates over the membrane. The more analyte in the sample, the more effectively it will compete with the salbutamol immobilised on the membrane for binding to the limited amount of antibodies of the detector reagent.. If salbutamol in the specimen is above 58g/kg, it will prevent the binding of the detector reagent with the salbutamol immobilised on the membrane, resulting in positive.
Uses: It is used when liquid heating is needed in industry, agriculture, health and medicine, scientific research and college labs etc. Characteristics: 1. Enclosed big size Ceramic Hot Plate with characteristics of flame protection and durability. 2. Heating and stirring can proceed simultaneously. 3. Heating power and stirring speed is stepless adjusted. The Digital type has the more function as follows: a.Can control the srirring clockwise and anticlockwise b.With two sensors can show different setting number c.Can show the setting temperature,hot plate surface temperature,setting speed and actual speed at the same time. d.Can show the setting temperature,tested liquid temperature,setting speed and actual speed at the same time 300, 190, 126 400, 240, 220.
The class II Biological Safety Cabinet is an opean front,ventilated cabinet.The Class II biological safety cabinet will provide personnel,environment and product protection. Front Window: Front window consists two-layer toughened glass>5mm,Motorized control. Work Zone: Work zone interior is made of 304 stainless steel. Front Panel: Superstructure is constructed from expoxy coated cold rolled steel for long life. VFD Display: Compared with LED,LCD,it demonstrates various colors with high bright,even in the evening.It shall work no less than 30,000 hours continually. UV Lamp: Interlocked and activated to work when blower and fluerescent lamp are offf and front window is closed. Foot Switch: Use foot switch to adjust the height of the front window. Front airflow intake grid: Aerodynamically designed front airflow intake gird; Eliminates potential turbulence and contamination. Waterproof Socket: 2 waterproof sockets are located in the side panel,for optimum convenience of using small devices inside the cabinet. Advantage: 1. Remote control. The operator need not to contact the biological safety cabinet directly,it¡¯s favorable for preventing cross contamination. It also makes the control operation much easier and convenient. 2. Foot Switch. Within the range of the activity, we could use foot switch to adjust the height of the front window. It is our unique design. 3. Work area surrounded by negative pressure. 4. Timer function 5. VFD display 6. Filter & UV life inquiry 7. Safety power lock Model: Parameter : 603588 Internal size(mm): 600,400,580 External size(mm) :700,500,1200 Tested Opening :200 mm Working Opening :400 mm Inflow Velocity :0.53 m/s DownFlow Velocity :0.33 m/s Filter : Two HEPA filter 99.999% efficient(0.3 microns) Blower : 1 Front Window : Two-layer toughened glass >5mm Noise: 65 dB UV lamp : 15W,1 Fluorescent Lamp : 40W,1 Lighting (Lux) : 680 Power(W) : 800 Water and Gas Tap : 0 Waterproof Socket : 2 Display : LED display Control System: Microprocessor Airflow System : 70% air recirculation,30% air exhaust Material: Work zone interior is made of 304 stainless steel, Body: Epoxy coated cold rolled steel Base (optional) Height: 635mm Caster Wheel: Universal Wheel Clean Level : 100 Electrical Parameter : 110~240V/50~60Hz (optional) Net weight(kg) : 80 Gross weight(kg) : 110 Package (mm): 950,850,1430 Standard Configuration: Body, Remote control, Foot switch, UV lamp and Fluorescent Lamp Optional Accessory : Armrest, Air curtain tester, Formalin fumigation sterilizer, Ammonium hydrogen carbonate neutralizer.
number,Name ,Quantity,instructions 1,Double layer reactor 20L,one,GG17Borosilicate glass 2,Stirring motor,one,Speed 0-780rpm 3,Frequency control,one,No classless ajustable speed £¬digital speed display(digital display temp) 4,Five mouth kettle,one,Euipped with the reactor body£¬condensor(backflow and condensor)¡¢feeding funnel, Thermometer tube,valve for lower the temp,stirring mouth;and can equip the solid charging port according to the customer needs 5,PTFE sealing,One set,Supply high vacuum environment 6,Frame of the reactor,one,Support the reactor,304 7,condensor,one,Condensation and distillation(backflow) 8,PTFE discharging valve,one,Can be discharged 9,Thermometer tube,one,For contain the thermometer 10,Feeding funnel,one,For dropping of the liquid 11,PTFE stirring rod,one,PTFE,with the liner stainless steel 12,Distillation and condensation pipe,one,Use to connect the kettle cover and condensor,separation,concentration 13,Release valve,one,Use to release air and fill the nitrogen 14,Vacuum table,one,Measuring the vacuum degree of the reactor 15,Bracket of the reaction body and cover,one,Aluminum alloy 16,Tray of the kettle body,one,Aluminum alloy 17,Hex wrench ,one,Adjust the frame 18,Universal joint,one,one. wooden cases or carton
Origin:Zhejiang China Specification:11.6*32mm Volumn:1.5ml Material:USP 1 expansion 30 Parkage:100pcs Delivery time:within 7 days Prompt delivery OEM:accepted Certification:ISO 9001 Packing:sealed/outer:carton/special ordering requirement accepted. Packing: sealed/outer:carton/special order accepted Weight: 0.6kg/pack(100pcs).
Metering mode: Double-beam C-t optical structure, blazed holographic grating, photomultiplier tube detection Wavelength range:190nm-1100nm Resolution:better than 0.15nm Spectro bandwidth:1.8nm Wavelength accuracy:0.3nm(with automatic wavelength calibration device.) Wavelength accuracy:
Temperature control range: 7¡æ-400¡æ of room temperature (increment by 1¡æ) Temperature control objects: column, ion chamber, thermal conductivity, sampler A, sample B, auxiliary (standby) Temperature programming phase: five Temperature programming rate: 0.1¡æ-40¡æ£¯min(increment by 0.1¡æ) Flame Ionization Detector (FID) Sensitivity : M¡Ü1¡Á10-11g/s(sample:l C16) Optimal test result: M¡Ü5¡Á10-12g/sl.
Features: 1. Temperature measurement range: 0-40(32¨h - 104¨h) 2. Precision ¨h measurement temperature:¡à1(2¨h) 3. Measurement temperature resolution: 1(1¨h) 4. Operation temperature:0 ¨c35(32¨h-90¨h) 5. Storage temperature: 0 ¨c50(32¨h-122¨h) 6. Dimension:135¡á65¡á40mm 7. Weigh:200g 8. Power supply: 2¡áaaa(1.5v) 9. Operating time: more than 2000 times per battery 10. Automatic temperature compensation 11. Automatic shut ¨h 12. Conversion between centigrade and fahrenheit degree 13. Alarm ¨h low voltage Propylene glycol Range: 0~50 Accuracy: 0.1 Divisions: 0.1 Ethylene glycol Range: 0~-50 Accuracy: 0.1 Divisions: 0.1 Battery Range: 1.00~1.50sg Accuracy: 0.01sg Divisions: 0.01sg Cleaner Range: 0~-40 Accuracy: 0.1 Divisions: 0.1.
Main features: It has been assessed and registered as meeting the requirements of ISO9001 and 14000. With Italian fuel injection system Automatically control system, digital display Time set, automatically incinerate and ignite Vacuum burning, fuel is diesel fuel Can meet the requirements of the national environmental protection standard. Low failure rate, low maintenance and running cost Technical parameter: Model Capacity Fuel Sampling Methods Power Power Supply JK-MI-10 10Kg/H Diesel fuel Automatically 700W 220V/50HZ JK-MI-20 20Kg/H Diesel fuel Automatically 900W 220V/50HZ JK-MI-30 30Kg/H Diesel fuel Automatically 1100W 220V/50HZ JK-MI-50 50Kg/H Diesel fuel Automatically 1800W 220V/50HZ.
39- liters laboratory flotation machine is applied in ore dressing by the method of laboratory floating. It is concatenation floatation machine with several sets of machines. And the number of chutes is even from 1 to 10. It is left-type or right-type according to user's demand. Structure and features: Laboratory flotation machine with 39 liters is impeller mechanical flotation machine. It is composed by the following main parts: (1). Tank The tank 1 is welded with steel plate, using the impeller to stir, simultaneously inflating the air into pulp. In order to adjust the thickness of slurry surface in tank and foam layer scraped, the intermediate tank 15 is made up of two slot panels, in which is the pulp surface regulator 5 installed, orifice 17 is installed on the tank cover 14, which is used to prevent the chaotic movement of pulp affects on the bubble zone, the gangue is entrained mechanically to the concentrate. Basin liner 6 is equipped in the tank to prevent the tank bottom worn, basin liner can be replaced. Discharging port 8 is placed outside the tank bottom, which is used to storage water when cleaning. The pulp flows into the intermediate tank 15 and the end tank 3 from the overflow port on the panel, the catheters of the intermediate tank bottom and the cover 14 on the groove wall bottom are put into the next tank, which will flow continuously through all the tanks of flotation machine. The pulp is fed from the feed chute 3, is discharged from the discharging port 8 of the tailing 1, the feed port 16 is equipped in front and at the back of tank bottom, which is easy to change the technological process. (2)Impeller system Impeller system is installed in the center of the flotation tank, the vertical arrangement coiled impeller 9 which leaves are up is fixed at the bottom of the impeller shaft 10 and around the vertical shaft tube 12. The tube top is located over the pulp stone and foam layer, the tube bottom is bearing the cover 14. When the impeller rotates, the quantities of air can be absorbed along the vertical tube 12. The protective plate 4 is fixed under the cover 14, the gap between the protective plate and impeller is related to the aeration rate, its maximum gap is less than 3mm, if the gap is too large, it is necessary to replace the protective plate or be adjusted appropriately. The hole of vertical tube 12 is used to cycle pulp, and make the pulp and air mix well. The upper of the impeller shaft rotates in the rolling shaft 11 installed in the bearing shell, the bearing shell is installed on the beam 7. The pulley fixed at the top of the shaft makes the motor 18 rotating through the triangle belt, of which the tension can be adjusted by the nut 19. (3). Shaving foam device Foam is scraped using the rotary scraper along the flotation machine, scraper 20 is installed out of the discharging port. The pulley is installed at the end of the scraper shaft, which rotates through the driving of the worm reducer 21 and V-belt. Technical parameters (1)Tank size: L¡ÁW¡ÁH 315¡Á315mm¡Á527mm (2)The effective volume: 39 liters (3)The flow of the pulp is calculated according to the production capacity (4)Aeration rate: 35-45 liters / min (5)Impeller diameter:200mm (6)Impeller speed: 809m/s (7)Impeller circumferential speed:8.14m/s (8)Scraper rpm: big wheel/small wheel 21r/min /13r/min (9)Motor: Model y900l-4 voltage :220/380V. Power:1.5KW rpm: 1400 r / min (10)Assembly method: Left-style (11)The outline size of machine: H: 930mm, W: 762mm, L (including 2 slots)1081mm (12)Total weight:(including 2 slot motors).
ZY6014A (Vertical-specimen) Flame Tester 1.Introduction: This apparatus is certificated by Guangzhou Hua Mei UL company ,it applies to research and manufacture for illumination, household, machine tool, motor, and such electric and electronic equipments and parts. It is also used to insulation materials, project plastics and other materials. 2. Standards: UL1581(section 1080.1£1080.14) , UL13. UL14 UL1655(VW-1 burning test). CSA (FT-1¡¢FT-2) 3. Main components: burning chamber ¡¢observation Windows¡¢ operation windows¡¢control system ¡¢gas control and so on . 4. Main parameters : 4.1 Burning chamber outside size: 2.4m(L)*1m(W)*2.5m(H) 4.2 Observation Windows: 3 observation Windows, made by reinforced glass, size: 730mm(H)*420mm(W) 4.3 Operation windows: 4 operation windows, interior diameter 150mm, outside diameter 220mm.sealed by 600mm long-arm leather glove. 4.4 Air inlet : 4 air inlets ,which diameter is 160mm, 4.5 Bottom anchor : bottom anchor size 2.4(L)*1m(W)*0.7m(H), 6 pulleys of which 4 are with lock. 4.6 Light equipment : 1 anti-fog,anti-smoke,ring lamp. 4.7 Control system: 1 sheet of burning instrument, 0 to 99.99s setting arbitrarily. 1 sheet of stop burning instrument, 0 to 99.99s setting arbitrarily . 0 to 999999 times setting arbitrarily. negotiable
ZY6056 Needle Flame Tester 1. Introduction : This device applies to electrical and electronic equipment and components ,also suitable for electrical insulating materials or other solid materials ,using simulation technology assess dangerous of catching fire or flame driven from internal equipment under fault condition. 2. Standards: IEC60695-2-2. GB/T5169.5-1997. 3. Main components: needle combustor, temperature measurement system , test chamber and so on. 4. Main parameters 4.1 Burner :inner diameter 0.5mm, length 35mm. 4.2 Flame standard : length more than 12mm. 4.3 Heat speed :100 - 700C costs 2.5S 4.4 Chamber capacity 0.5M 60cm(L) * 95cm(W) * 90cm(H) 4.5 Conductive copper ¥Õ4.0 * 6.0mm, 4.6 Outsize :61cm(D) * 120cm(W) * 105cm(H).
ZY6078 Vulcanization Tester 1. Introduction : This device applies to show vulcanization curve , so that a new hand can easily get the best reasonable ingredients and balanceable formula of scorching and vulcanization by computer and software . 2. Main components : 2.1 Machine parts: cabinet , upper and bottom mould cavity ,and so on. 2.2 Electrical control system 2.3 Printer 2.4 Pneumatic system.
ZY 6192 Halogen Release Measurement Device 1. Introduction: this device applies to measure halogen content PH conductivity when wires and cables are burning according to IEC60754. 2. Standards:GB/T17650.1-1998, GB/T17650.2-1998, IEC60754-1:1994, IEC60754-2:1991 . GB/T19666-2005, GA306.1-2007, GA306.2-2007, UL2556-2007. 3. Main components : quarts material tubular furnace combustion tube, air collection system, air supply system , PH meter , conductivity analyzer 4. Main parameters: 4.1 Tubular furnace chamber size : 42mm * 600mm, power input :220V/10kw. 4.2 Combustion tube 40mm, 4.3 PH meter : precision 0.02PH. 4.4 Conductivity : measurement scope :(0~1¡Á105)¦ÌS/ cm. 4.5 Air flex meter :20-200L adjustable.
LK ¡§C210A Black -white Densimeter Features: This product uses circuits of high-tech products, working with the advantages of accurate measurement, good stability, convenient operation, etc. Parameter: Density range : 0 = 0.00-5.00 Light hole size : Dia 2mm Reading stability : about 0.02 Uncertainty : 0.00-3.00 0.02D, 3.00-4.00 0.04D, 4.00-5.00 0.08D Display form : 3 digits display Sampling time : 0.8s Working environment : 0 ¡§C 40, relative humidity
Hardness tester LK120 Features: Easy one handed operation Digital Display Compact body for areas of restricted space Slim detector allows measurements to be taken on complex curved surfaces such as welds, moulds etc, as well as conventional flat surfaces Conversion function for different hardness scales Self calibrating Supplied with NAMAS certified test piece Used in any direction Lightweight, portable and easy to carry Using large-screen 128 * 64 dot matrix LCD module, information abundant and intuitive. Can be pre-set limit, hardness, when beyond the scope it automatic alarm, convenience customers batch test. English display: menu type operation, uses simple and convenient. Technical parameter: Measuring scope: HLD (170-960) HLD Measuring direction: support plummet, inclined, level, oblique, pure vertical measured material: Steel ,alloy steel, stainless steel, grey cast iron, ductile iron, zinc alloy, copper alloy ,casting of copper, , Copper alloy (brass, bronze), pure copper, forged steel . Hardness formats: HL,HB, HRB, HRC,HRA,HV,HS Display: high contrast segment code type LCD display Data storage: maximum 500 groups (impact times: 32-1) Paper width: 57.5¡À0.5£©mm Paper coil diameter: 30mm Work voltage: 6V Nimh batteries Work Time: about 150h, With power saving function like auto dormancy, automatic shutdown etc. Measuring direction: 360¡ã operating temperature: -10 ~ +50¡æ Shape dimension:213*80*215mm relative humidity:
Table-top high speed refrigerated centrifuge.