Model HQ15-A5 HQ15-A100
Rated primary current 5A AC 100A AC
Output Voltage 10 mV AC/A 1mV AC/A
Maximum input current 50A AC (Continuous) 130A AC (Continuous)
(45-66Hz,Ambient temp.50C)
Amplitude accuracy ±0.3%RD ±0.02%FS (10%-100%I1n),(45Hz- 66Hz)
Phase accuracy ±2 (10%-100%I1n)(45Hz-5kHZ)
The amplitude frequency characteristic ±0.1% (45Hz-5kHZ)(Deviation accuracy)
Conductor impact ±0.5 (Off-center)
The influence of external lectromagnetic fields 0.1A (In AC 400A / m electromagnetic fields)
Temperature coefficient ±0.02%/C of the reading data
Dielectric strength 3000 V AC rms/Continue 15 seconds(Circuits-iron core, iron core-shell)
The maximum rated voltage 300V AC rms
Applicable standards Safety: EN61010-2-032:2002,300V CAT III, Contamination II
EMC: EN61326:1997+A1:1998+A2:2001+A3:2003(Class A)
Mechanical parameters
Measurable conductor diameter Max.15mm
Cable length About 3m
Dimension (W x H x D) About 46135 21 (Excluding protruding parts)
Weight About 230g
Environmental conditions
Operating temperature 0 to 50 C (32-122 F)
Operating humidity 80%RH(No condensate)
Storage temperature -10 to 60 C (14-140F)
Storage humidity 80%RH(No condensate)
Operating environment Indoor, altitude up to 2000 meters
Ratio 1000: 1 or 2000:1 (customized)
Accuracy class 0.2%, 0.5%, 1%
Primary current 0 - 3000A AC
Secondary current 0 - 5A AC (customized)
Max. Cont. Input current 3600A
Over voltage category CAT III 600V
Output signal (AC current) 500mA,1A,2A,5A AC at nominal input current
Output signal (AC voltage) 333mV, 500mV, 1V, 5V AC at nominal input current
Frequency range 40Hz-2000Hz
Dielectric strength 3KV 50Hz/60Hz at 1 minute
Temperature range -20C to +55C
Output 2.5 meter cable with D01 connector
Max. voltage not insulated conductors 600 V
Standard EN 61010-1, EN 61010-2-032, IEC60044-1
Installation Clamp type
Output mode Lead output (2.5m)
Mechanical parameters
Dimensions (L x W x H)(mm) 180 x 319 x 35
Weight (g) 1100
Holding wire diameter (mm) 125
Max. jaw opening (mm) 125
Color Black
Material PC+ABS+Polycarbonate, UL94 V0
Ratio 1000: 1 or 2000:1 (customized)
Accuracy class 0.2%, 0.5%, 1%
Primary current 0 - 3000A AC
Secondary current 0 - 5A AC (customized)
Max. Cont. Input current 3600A
Over voltage category CAT III 600 V
Output signal (AC current) 500mA,1A,5A AC at nominal input current
Output signal (AC voltage) 333mV,500mV,1V,5V AC at nominal input current
Frequency range 40Hz-2000Hz
Dielectric strength 3KV 50Hz/60Hz at 1 minute
Temperature range -20C to +55C
Output 2.5 meter cable with D01 connector
Max. voltage not insulated conductors 600 V
Standard EN 61010-1, EN 61010-2-032, IEC60044-1
Installation Clamp type
Output mode Lead output(2.5m)
Mechanical parameters
Dimensions (L x W x H) (mm) 116 x 327 x 35
Weight (g) 1200
Holding wire diameter (mm) 120 x 50
Max. jaw opening (mm) 50
Jaw Color White
Material PC+ABS+Polycarbonate, UL94 V0
FEATURES
Suitable for 5A, 10A cable online measurement
Holding wire diameter: 8mm
Dimension: 42.6mm 122.5mm 23mm
Load capacity: 4
Installation: clamp type
Output mode: lead output
PARAMETERS
Electrical parameters
Ratio 1000: 1 or 2000:1 (customized)
Accuracy class 0.1%
Primary current 0 - 10A AC
Secondary current 0 - 10mA AC (customized)
Max. Cont. Input current 12 A
Load capacity 4
Over voltage category CAT III 600V
Output signal (AC current) From 0 to 10mA AC at nominal input current
Output signal (AC voltage) From 0 to 100mV AC at nominal input current
Frequency range 40Hz-2000Hz
Dielectric strength 3KV 50Hz/60Hz at 1minute
Temperature range -20C to +55C
Output 2.5 meter cable with D01 connector
Max. voltage not insulated conductors 600 V
Standard EN 61010-1, EN 61010-2-032, IEC60044-1
Installation Clamp type
Output mode Lead output(2.5m)
Mechanical parameters
Dimensions (L x W x H) (mm) 42.6x122.5x23
Weight (g) 250
Holding wire diameter (mm) 8
Max. jaw opening (mm) 8
Color Black
Material PC+ABS+Polycarbonate, UL94 V0
87348 Communication Suppliers
Short on time? Let Communication sellers contact you.
FEATURES
Suitable for 10A-200A cable online measurement.
Holding wire diameter: 20mm
Dimension: 52.5mm137.5mm28mm
Load capacity:
Installation: clamp type
Output mode: lead output
PARAMETERS
Electrical parameters
Ratio 1000: 1 or 2000:1 (customized)
Accuracy class 0.1%, 0.2%
Primary current 0 - 200A AC
Secondary current 0 - 200mA AC (customized)
Max. Cont. Input current 240A
Load capacity 4
Over voltage category CAT III 600V
Output signal (AC current) From 0 to 200mA AC at nominal input current
Output signal (AC voltage) From 0 to 2V AC at nominal input current
Frequency range 40Hz-2000Hz
Dielectric strength 3KV 50Hz/60Hz at 1minute
Temperature range -20C to +55C
Output 2.5 meter cable with D01 connector
Max. voltage not insulated conductors 600 V
Standard EN 61010-1, EN 61010-2-032, IEC60044-1
Installation Clamp type
Output mode Lead output(2.5m)
Mechanical parameters
Dimensions (L x W x H) (mm) 52.5 x 137.5 x 28
Weight (g) 400
Holding wire diameter (mm) 20
Max. jaw opening (mm) 20
Jaw color Red, yellow, blue, green, black
Material PC+ABS+Polycarbonate, UL94 V0
FEATURES
Suitable for 5A, 10A cable online measurement.
Holding wire diameter: 8mm
Dimension: 42.6mm 122.5mm 23mm
Load capacity: 4
Installation: clamp type
Output mode: lead output
PARAMETERS
Electrical parameters
Ratio 1000: 1 or 2000:1 (customized)
Accuracy class 0.2%, 0.5%
Primary current 0 - 10A AC
Secondary current 0 - 10mA AC (customized)
Max. Cont. Input current 12 A
Load capacity 4
Over voltage category CAT III 600V
Output signal (AC current) From 0 to 10mA AC at nominal input current
Output signal (AC voltage) From 0 to 1V AC at nominal input current
Frequency range 40Hz-2000Hz
Dielectric strength 3KV 50Hz/60Hz at 1minute
Temperature range -20C to +55C
Output 2.5 meter cable with D01 connector
Max. voltage not insulated conductors 600 V
Standard EN 61010-1, EN 61010-2-032, IEC60044-1
Installation Clamp type
Output mode Lead output(2.5m)
Mechanical parameters
Dimensions (L x W x H) (mm) 42.6 122.5 23
Weight (g) 225
Holding wire diameter (mm) 8
Max. jaw opening (mm) 8
Color Gray
Material PC+ABS+Polycarbonate, UL94 V0
FEATURES
Suitable for 10A-200A cable online measurement.
Holding wire diameter: 20mm
Dimension: 52.5mm 137.5mm 28mm
Load capacity: 4
Installation: clamp type
Output mode: lead output
PARAMETERS
Electrical parameters
Ratio 1000: 1 or 2000:1 (customized)
Accuracy class 0.1%, 0.2%
Primary current 0 - 200A AC
Secondary current 0 - 200mA AC (customized)
Max. Cont. Input current 240A
Load capacity 4
Over voltage category CAT III 600V
Output signal (AC current) From 0 to 200mA AC at nominal input current
Output signal (AC voltage) From 0 to 2V AC at nominal input current
Frequency range 40Hz-2000Hz
Dielectric strength 3KV 50Hz/60Hz at 1minute
Temperature range -20C to +55C
Output 2.5 meter cable with D01 connector
Max. voltage not insulated conductors 600 V
Standard EN 61010-1, EN 61010-2-032, IEC60044-1
Installation Clamp type
Output mode Lead output(2.5m)
Mechanical parameters
Dimensions (L x W x H) (mm) 52.5 x 137.5 x 28
Weight (g) 400
Holding wire diameter (mm) 20
Max. jaw opening (mm) 20
Jaw color Red, yellow, blue, green, black
Material PC+ABS+Polycarbonate, UL94 V0
FEATURES
Most cost-effective
Faster installation
Safe and easy installations
High accuracy 0.5
Holding wire diameter: �?16mm
Measurement range of 1mA to 200A AC
Low phase shift for power measurement
Output model: Lead output(2.5m)
Isolated plastic case recognized according to UL94-V0
Small-size, compact size, light-weight
Over-Voltage protection circuit is installed.
CE, UL / EN 61010 - 1 certified
PARAMETERS
Technical parameters
Standards IEC/EN60044-1 & IEC61010-1 & IEC61869-2&ANSI C57.13
Ratio 1000: 1 or 2000:1 , customized
Nominal input current Primary current 20A/30A/40A/50A/60A/80A/100A/150A/200A
Overload withstand 1.2 times rated current continuously
Accuracy 0.2%, 0.5 %, 1%
System Voltage 720V(0.72kV)
Output signal 10mA-200mA AC optional
333mV AC or 100mV-2V optional
Frequency range 40 Hz-500 Hz
Dielectric strength 3KV 50Hz/60Hz at 1 minute
Output Standard 2.5 meter cable
Protection Level 3.0V0-P
Installation Category CAT or CAT 600VAC
Max. jaw opening 16 mm
Mechanical parameters
Dimensions (WDH) (mm) 38mm 55mm 18mm
Weight(g) 60
Operating conditions
Operating temperature -25C to +55C
Relative Humidity 0-85% non-condensing
Altitude
FEATURES
Most cost-effective
Faster installation
Safe and easy installations
High accuracy 0.5
Holding wire diameter: 32mm
Ratio ranging from 60/1A to 600/5A
CE, UL
PARAMETERS
Technical parameters
Standards IEC/EN60044-1 & IEC61010-1 & IEC61869-2&ANSI C57.13
Ratio 400: 5 or 200:5 , customized
Nominal input current Primary current 100A/150A/200A/300A/400A/500A/600A
Overload withstand 1.2 times rated current continuously
Accuracy 0.2%, 0.5 %, 1%/60Hz
System Voltage 720V(0.72kV)
Output signal 1A or 5A
333mV AC or 100mV-2V optional
Burden 2.5VA
Frequency range 40 Hz-500 Hz
Dielectric strength 3KV 50Hz/60Hz at 1 minute
Output Standard 2.5 meter cable
Max. jaw opening 32 mm
Mechanical parameters
Dimensions (DH) (mm) 110mm130mm 41mm
Weight(g) 700
Operating conditions
Operating temperature -25 C to +55 C
Relative Humidity 0-85% non-condensing
Altitude
Standards IEC60044-1; IEC 61869-2; ANSI C57.13; NTC 2205; GB1208-2006
Accuracy Class 0.5%, 1%
Range of primary rated current 300-3000A
Range of Rated load 25VA
Rated frequency 50/60Hz
Rated secondary current 5A or 1A
Secondary winding power frequency withstand voltage 3kV, 1min
Safety Factor Rating (FS)
Technical parameters
Standards IEC60044-1; IEC 61869-2; NTC 2205; GB1208-2006; ANSI C57.13
Accuracy Class 0.5S, 0.5%, 1%, 3%
Range of primary rated current 100-1000A
Range of Rated load 10VA
Rated frequency 50/60Hz
Rated secondary current 5A or 1A
Rated short-time thermal current 40kA, 1S
Rated continuous thermal current 150%I1n
Secondary winding power frequency withstand voltage 3kV, 1min
Safety Factor Rating (FS)
The Primary current sensor uses the same sensor technology as the original Rogowski coil. The True RMS inductive sensor does not use magnetic materials. The opening of the sensor is electronically closed and external currents are electronically rejected.
The accuracy, external current reject, and range of currents measured by the patented amp sensor substantially exceed the performance of the best clamp-on sensors. The key feature of the unit is the ability to leave it deployed on the line to record readings every 15 minutes for 90+ days. It easily attaches to the line with a standard insulating bar. Once on the line, it immediately begins to collect and record the primary current on the line.
The Primary current sensor is equipped with a 433M wireless port for communicating the recorded data into the userâ??s PC. The data is downloaded through GF2018S PC-Link Software, which allows the user to download, view and query the data stored on the Primary current recorder.
The housing of the Primary current sensor is made of ABS+PC and is built to operate safely, even in severe utility environments. It is resistant to shock, waterproof and resistant to flame. It also operates within a wide temperature range. The Primary current recorder has a screw insulation bar of installation, which allows it to hang on the line securely in all weather conditions.
PC-Link Software is a user-friendly software interface that allows the user to download, view, graph and export data from the Primary current recorder into Microsoft Excel. The data directly transfers from the Primary current recorder into Excel through an 433M Port.
PARAMETERS
Basic parametersã??
Recording ammeter kit 3 wireless current sensors (GF2018A, GF2018B, GF2018C)
433 HHT(handheld terminal) or 433M wireless data reader(GF2018R)
PC-LinkSoftware software(GF2018S)
Carrying case
Data recording interval 1min, 5min, 10min,15min, 30min;
Time can be set from 1 second to 60 minutes
Communication distance(wireless) Max 100m
Communication 433M, 868M or 915M (option)
Installation Installation with electricity; Disassemble with electricity
Battery 3.6 volt lithium battery,9000mAh; Battery can be replaced
Software requirements PC-Linksoftware & microsoft Excel
Processor 100 MHz or higher (200 MHz or higher recommended)
RAM 32 MB, 64M recommended
Drive space 15 MB to load software, 10 MB of operating Space
Use of position Outdoor or indoor
Electrical parameters
Range of operation
Voltage 69kV,35kV,20KV, 10kV, 6kV, 0.38kV
Current 0 to 400A; 0 to 800A; 0 to 1500A; 0 to 3500A;
Sensor opening Up to 3.3 cm
Resolution
Amps 1 to 99.9A 0.1A
100 to 300A 1A
Amps accuracy ±1% of reading plus 2 counts
Frequency 60Hz (57-63 Hz) or 50Hz (47-53 Hz) models available
Mechanical parameters
Weight (kg) 0.48
Carrying case(kg) 6.5
Environmental conditions
Operating temperature -40C to 60C
87348 Communication Suppliers