FEATURES
Suitable for 5A, 10A cable online measurement.
Holding wire diameter: 8mm
Dimension: 42.6mm 122.5mm 23mm
Load capacity: 4
Installation: clamp type
Output mode: lead output
PARAMETERS
Electrical parameters
Ratio 1000: 1 or 2000:1 (customized)
Accuracy class 0.2%, 0.5%
Primary current 0 - 10A AC
Secondary current 0 - 10mA AC (customized)
Max. Cont. Input current 12 A
Load capacity 4
Over voltage category CAT III 600V
Output signal (AC current) From 0 to 10mA AC at nominal input current
Output signal (AC voltage) From 0 to 1V AC at nominal input current
Frequency range 40Hz-2000Hz
Dielectric strength 3KV 50Hz/60Hz at 1minute
Temperature range -20C to +55C
Output 2.5 meter cable with D01 connector
Max. voltage not insulated conductors 600 V
Standard EN 61010-1, EN 61010-2-032, IEC60044-1
Installation Clamp type
Output mode Lead output(2.5m)
Mechanical parameters
Dimensions (L x W x H) (mm) 42.6 122.5 23
Weight (g) 225
Holding wire diameter (mm) 8
Max. jaw opening (mm) 8
Color Gray
Material PC+ABS+Polycarbonate, UL94 V0
Model HQ15-A5 HQ15-A100 Rated primary current 5A AC 100A AC Output Voltage 10 mV AC/A 1mV AC/A Maximum input current 50A AC (Continuous) 130A AC (Continuous) (45-66Hz,Ambient temp.50C) Amplitude accuracy ±0.3%RD ±0.02%FS (10%-100%I1n),(45Hz- 66Hz) Phase accuracy ±2 (10%-100%I1n)(45Hz-5kHZ) The amplitude frequency characteristic ±0.1% (45Hz-5kHZ)(Deviation accuracy) Conductor impact ±0.5 (Off-center) The influence of external lectromagnetic fields 0.1A (In AC 400A / m electromagnetic fields) Temperature coefficient ±0.02%/C of the reading data Dielectric strength 3000 V AC rms/Continue 15 seconds(Circuits-iron core, iron core-shell) The maximum rated voltage 300V AC rms Applicable standards Safety: EN61010-2-032:2002,300V CAT III, Contamination II EMC: EN61326:1997+A1:1998+A2:2001+A3:2003(Class A) Mechanical parameters Measurable conductor diameter Max.15mm Cable length About 3m Dimension (W x H x D) About 46135 21 (Excluding protruding parts) Weight About 230g Environmental conditions Operating temperature 0 to 50 C (32-122 F) Operating humidity 80%RH(No condensate) Storage temperature -10 to 60 C (14-140F) Storage humidity 80%RH(No condensate) Operating environment Indoor, altitude up to 2000 meters
FEATURES Suitable for 10A-200A cable online measurement. Holding wire diameter: 20mm Dimension: 52.5mm137.5mm28mm Load capacity: Installation: clamp type Output mode: lead output PARAMETERS Electrical parameters Ratio 1000: 1 or 2000:1 (customized) Accuracy class 0.1%, 0.2% Primary current 0 - 200A AC Secondary current 0 - 200mA AC (customized) Max. Cont. Input current 240A Load capacity 4 Over voltage category CAT III 600V Output signal (AC current) From 0 to 200mA AC at nominal input current Output signal (AC voltage) From 0 to 2V AC at nominal input current Frequency range 40Hz-2000Hz Dielectric strength 3KV 50Hz/60Hz at 1minute Temperature range -20C to +55C Output 2.5 meter cable with D01 connector Max. voltage not insulated conductors 600 V Standard EN 61010-1, EN 61010-2-032, IEC60044-1 Installation Clamp type Output mode Lead output(2.5m) Mechanical parameters Dimensions (L x W x H) (mm) 52.5 x 137.5 x 28 Weight (g) 400 Holding wire diameter (mm) 20 Max. jaw opening (mm) 20 Jaw color Red, yellow, blue, green, black Material PC+ABS+Polycarbonate, UL94 V0
FEATURES Suitable for 10A-200A cable online measurement. Holding wire diameter: 20mm Dimension: 52.5mm 137.5mm 28mm Load capacity: 4 Installation: clamp type Output mode: lead output PARAMETERS Electrical parameters Ratio 1000: 1 or 2000:1 (customized) Accuracy class 0.1%, 0.2% Primary current 0 - 200A AC Secondary current 0 - 200mA AC (customized) Max. Cont. Input current 240A Load capacity 4 Over voltage category CAT III 600V Output signal (AC current) From 0 to 200mA AC at nominal input current Output signal (AC voltage) From 0 to 2V AC at nominal input current Frequency range 40Hz-2000Hz Dielectric strength 3KV 50Hz/60Hz at 1minute Temperature range -20C to +55C Output 2.5 meter cable with D01 connector Max. voltage not insulated conductors 600 V Standard EN 61010-1, EN 61010-2-032, IEC60044-1 Installation Clamp type Output mode Lead output(2.5m) Mechanical parameters Dimensions (L x W x H) (mm) 52.5 x 137.5 x 28 Weight (g) 400 Holding wire diameter (mm) 20 Max. jaw opening (mm) 20 Jaw color Red, yellow, blue, green, black Material PC+ABS+Polycarbonate, UL94 V0
Main FeaturesAC/DC Current Sensor Model No.: MEWOI-DRK1D Name: MEWOI-DRK1D-50-500A AC/DC Ï?20mm Open-loop Hall current Sensor Jaw Size21mm Rated input Current IPN50 100 200 300 400 500 A Primary Current Measure range(IP)0~±100 0~±200 0~±400 0~±600 0~±800 0~±800 A Rated output voltage of secondary side2.5±1.25 ±1% V Power Supply Voltage VCCDC +5V ±5% V Current consumptionVCC=+5V 10 mA Galvanic isolation (Vd) 2.5KV /50Hz/1min
Three phase current transformer Model: SCT2851A, SCT2851B, SCT2851C Input current: 60-630A Output current: 5A/ 1A Accuracy: 1.0/0.5
Type : RTCS100B,RTCS200B,RTCS300B,RTCS400B,RTCS500B,RTCS600B, IPN Primary nominal input current : 100, 200, 300, 400, 500, 600 A IP Measuring range of primary current : 0~300, 0~600, 0~900, 0~900, 0~900, 0~900 A VOUT Nominal output voltage : 41%V VC Supply voltage : 15(5%) V IC Current consumption : VC=15V
Type : RTCS050EK1, RTCS100EK1, RTCS200EK1, RTCS300EK1, RTCS400EK1, RTCS500EK1 IPN : Primary nominal input current : 50, 100, 200, 300, 400, 500A IP Measuring range of primary current : 0~¡À100, 0~¡À200, 0~¡À400, 0 ~¡À600, 0~¡À800, 0~¡À1000 A VOUT Nominal output voltage : 4¡À1%V VC Supply voltage : ¡À12~¡À15(¡À5%)V 20 pcs/inner,200 pcs/CTN,14.5 KGS,40x25x30CM.
Min Fetures: DC lekge current mesurement Model No.::MEWOI-DRST-200m(DC) Nme: MEWOI-DRST-200m(DC) Split Core Lekge current sensor Dimeter:Ï?19mm Rted input Current (IPN)102050100200m(DC) Primry Current Mesure rnge(IP)0-±200-±500-±1000-±2000-±300m Rted output voltge of secondry sideDC ±5V, 4-20m, 0-20m (±1%)V Power Supply Voltge (VCC)DC ±12V-±15V (±5%)V Current consumption
Hall components have many advantages, they are strong construction, small volume, light weight, long service life , easy installation, wide bandwidth ( can reach 1 MHZ);vibration resistance, Not afraid of pollution or corrosion of dust ,oil, greasy dirt, moisture , salt mist and so on. • Hall linear elements are excellent accuracy, good linearity. Hall switch elements are no contactless, no in-gage, clear output waveforms, no instant jitter, high-precision positional repeatability. In recent years, with the development of China aerospace industry .Our hall-effect product is widely used in new rocket ,new generation communication satellite, new navigation satellite, new recoverable satellites, chang-e satellites, Shenzhou spacecraft and so on . Its related products is also can widely used in automotive matching, environmental protection, medical equipments, instrument, power protection, office automation and many other civil fields. It is wildly used in frequency driver, contravariant devices, UPS, contravariant welding machine, converting station, electrolyze & electroplating, CNC machine, PC monitoring, grid monitoring, insulated current & voltage testing, Etc. Working Principle 1.Direct measurement principle 2.Magnetic compensation principle Packed in box ,can be customized