Standards IEC60044-1; IEC 61869-2; ANSI C57.13; NTC 2205; GB1208-2006
Rated primary current 30-1000A
Rated load 20VA
Rated frequency 50Hz or 60Hz
Rated secondary current 5A or 1A
Rated short-time thermal current 40kA, 1S
Rated continuous thermal current 120%I1n
Secondary winding power-frequency voltage 3kV, 1min
Instrument security factor FS 10
Mechanical parameters
Dimensions (WDH) (mm) 45x120x65
Weight (kg) 2.1
Operating conditions
Operating temperature -35C to +55C
Daily average temp
We are one of the leading trader and supplier of world class range of Resin Cast Current Transformers that are procured from our certified vendors of the market. These transformers are fabricated using the finest grade raw material and sophisticated technology at vendors’ end. Our offered products are widely demanded among clients due to their quality attributes like high performance, user friendly interface, longer service life and compact design. Our offered transformers are carefully examined on various parameters by our vendors to ensure their flawlessness. Specifications: Resin cast current transformers up to 33KV class As per mutual discussion
Resin cast current transformers are available for metering and protection application. These current transformers are mainly fabricated according to client’s specification. Ct coils are encapsulated in cast resin (polyester / epoxy). Secondary terminals are provided with either screws or studs. The main insulation between primary and secondary and earth is obtained by this epoxy resin. These transformers are of compact design with high mechanical and electrical properties. These are non-hygroscopic and hence give very good insulation properties even in given humid conditions. General particulars Rated voltage: 11 kv Rated primary current: 100 a Rated secondary current: 1a or 5a Rate burden: 5va Rated frequency: 50hz Accuracy class: 0.5 or 0.5s Temperature: as per is-2705/1992 Highest system voltage: 12kv Insulation level: 28kvrms/75kv(p) Stc: 13.1ka for 1 sec Continues thermal current: 1.2 times of rated current Core material: crgo Copper wire material: enameled wire as per is-4800 part-4 or iec-317 Insulation class/material: epoxy resin Secondary terminal: m5 brass bolt with nut &washer or m5 threaded bush with screw &washer Primary terminal p1 & p2 size and material Mounting base: ms 5mm thick zinc plated Rountine test :as per is-2705/1992
LZZBJ9-12A1(A2) current transformer, epoxy resin casting insulation and fully enclosed support construction, encloses primary & secondary windings and annular core in the epoxy resin casting body. The product has the feature of light weight, omni-directional installation, withstanding nastiness and dampness. It is widely used for measuring current, electric energy and protective relaying in the electrical system with the rated frequency 50- 60Hz and highest voltage for equipment 7.2 kV /12 kV . Main technical parameter 1. Rated voltage: 6.6 kV or 11 kV etc. 2.Rated secondary current: 5A?1A 3.Rated insulation level: 7.2/20/60 kV or 12/28/75 kV 4.Standards: IEC60044-1.2003 Part 1: Instrument transformers-Part1: Current transformers 5.Other technical parameter pls see as follows Rated transformation ratio(A) Accuracy classes combination Rated output(VA) (ALF) (FS) Short-time thermal current Ith(kA/S) Rated dynamic current Idyn(kA) Measuring Protective 0.2(S) 0.5 10P 10-200/5 0.2(S)/0.2(S) 0.2(S)/0.5 0.2(S)/10P 0.5/10P 0.2S/0.5/10P 0.2/0.5/10P 10 15 15 15 10 15 20 5 (10) 150I1n 375I1n 300/5 31.5 80 400/5 31.5 80 500/5 40 100 600/5 50 125 800/5 20 63 125 1000/5 80 160 1200~1500/5 80 160 1500~2000/5 100 160 2000~3150/5 130 160 Rated transformation ratio(A) Accuracy classes combination Rated output(VA) (ALF) (FS) Short-time thermal current Ith(kA/S) Rated dynamic current Idyn(kA) Measuring Protective 0.2(S) 0.5 10P 10-200/5 0.2S//0.5/ 10P 0.5/0.5/10P 10 15 15 15 20 10 15 5 (10) 150I1n 375I1n 300/5 31.5 80 400/5 31.5 80 500/5 40 100 600/5 50 125 800/5 63 125 1000/5 80 160 1200~1500/5 80 160 1500~2000/5 100 160 2000~3150/5 130 160 Remarks: Upon request we are glad to offer transformers according to other standards or with non-standard technical specs.
TRANSFORMER : ALL TYPE : Dry Type/Air Cooled, Oil Cooled, Water. We can supply small transformer from 33kV and up to 54000kVA or more. For more details please contact us.
Product Description Type: Dry Type Transformer Model Number: SC(B)10-30~2500/35 Phase: Three Rated High Voltage: 10(11, 10.5, 6.6, 6.3, 6 )KV Rated Low Voltage: 10KV, 0.4KV or as required Rated Capacity: 30~2500KVA Our dry type transformers are in conformity with the following standards: 1. National Standard of China GB1904.11-2007Power Transformers 2. International Electro Technical Commission Standards IEC 60076-112004 Dry Type Transformers 3. German Industry Standard DIN EN 60076-11:2005 Dry Type Transformers
We can supply solar transformers ideally suited for large MW scale solar PV plants. Bullet Points - . Inverter duty Solar transformers, suitable for solar load profile . Multi-winding (2 to 6 windings), oil-filled or dry type. . 2MVA to 12.5MVA, LV Side: 0.35kV to 0.69kV, HV Side 3.3kV to 33kV . Low-loss, with Aluminum or Copper winding. . Electrostatic shield between LV and MV Winding. For more details please contact us.
For price, specification and other details please contact us