Measuring instruments and equipments, electrical.
Antigen and antibody, rapid test and elisa test.
Hand tools, safety products.
Energy Meter Tester Energy Meter Calibrator Energy Meter Test Bench Energy Meter Test System.
Testing devices.Services of testing valves and repairing
1. Follow the specifications: ASTM D5882 Standard Test Method for Low Strain Integrity Testing of Piles JGJ106-2003 (China) Technical code for testing of building foundation piles 2. Parameters:: 1). Size: 62 * 172 * 225 mm. 2). Weight: 2.0 kg. 3). High-contrast touch screen display. 4). Temperature range: Operating Range: 0° to 40° C; Storage Range: -20° to 65° C. 5). Powered by internal battery (6 hours duration). 3. Functional: 1). The LPT-E is used for Integrity pile testing and judging defect position 2). Automatic data storage 3). Signal amplification capability 4). Data can be averaged over a variable number of blows. 5). Variable signal amplification over time 6). 24-bit A/D converter 7). Sample size: 4k 8). Sample Frequency: 48kHz, 96 kHz,144 kHz
1. Follow the specifications: ASTM D4945 Standard Test Method for High-Strain Dynamic Testing of Piles JGJ106-2003 (China) Technical code for testing of building foundation piles 2. Physical (1) Size: 62 *172 * 225 mm (2) Weight: 1.7 kg (3) 8 inch and high brightness color LCD touch screen (4) Temperature range: Operating: 0° to 40° C; Storage: -20° to 65° C (5) The cables and connectors are suitable for PDA 3. Technical (1) HPT used for determining the pile bearing capacity and pile integrity. (2) It can be used for pile driving monitoring and the cast-in-place pile test. (3) Sampling frequency is Optional of 10 kHz, 20 kHz, 30 kHz and 40 kHz. (4) Sampling points are optional of 1024, 2048 and 4096. Maximum sampling time is up to 400 ms (5) Before test the two accelerometers and two strain transducers are self-checked automatically, determine whether the system is in normal state. (6) Automatically check the static strain deviation of the strain transducer during installation and adjusted to zero before blow. (7) Test data exported through the external u-disk (8) During test every blow can be saved automatically (9) Storage capacity of more than ten thousands blows. (10) HPT can be used for pile driving monitoring and the cast-in-place pile (11) HPT data can save as *.X01(used for PDA-W) (12) The main cable and connecting cable are compatible with the PDA. (13) Built-in lithium battery can be used more than 5 hours continuously. (14) PDAR program carry on CASE method analysis. (15) RCAPWAP program carry on match analysis automatically or manually.
1. Follow the specifications: ASTM D5882 Standard Test Method for Low Strain Integrity Testing of Piles JGJ106-2003 (China) Technical code for testing of building foundation piles 2. Parameters:: 1). Size: 62 * 172 * 225 mm. 2). Weight: 2.0 kg. 3). High-contrast touch screen display. 4). Temperature range: Operating Range: 0° to 40° C; Storage Range: -20° to 65° C. 5). Powered by internal battery (6 hours duration). 3. Functional: 1). The LPT-E is used for Integrity pile testing and judging defect position 2). Automatic data storage 3). Signal amplification capability 4). Data can be averaged over a variable number of blows. 5). Variable signal amplification over time 6). 24-bit A/D converter 7). Sample size: 4k 8). Sample Frequency: 48kHz, 96 kHz,144 kHz
1. Follow the specifications: ASTM D4945 Standard Test Method for High-Strain Dynamic Testing of Piles JGJ106-2003 (China) Technical code for testing of building foundation piles 2. Physical (1) Size: 62 *172 * 225 mm (2) Weight: 1.7 kg (3) 8 inch and high brightness color LCD touch screen (4) Temperature range: Operating: 0° to 40° C; Storage: -20° to 65° C (5) The cables and connectors are suitable for PDA 3. Technical (1) HPT used for determining the pile bearing capacity and pile integrity. (2) It can be used for pile driving monitoring and the cast-in-place pile test. (3) Sampling frequency is Optional of 10 kHz, 20 kHz, 30 kHz and 40 kHz. (4) Sampling points are optional of 1024, 2048 and 4096. Maximum sampling time is up to 400 ms (5) Before test the two accelerometers and two strain transducers are self-checked automatically, determine whether the system is in normal state. (6) Automatically check the static strain deviation of the strain transducer during installation and adjusted to zero before blow. (7) Test data exported through the external u-disk (8) During test every blow can be saved automatically (9) Storage capacity of more than ten thousands blows. (10) HPT can be used for pile driving monitoring and the cast-in-place pile (11) HPT data can save as *.X01(used for PDA-W) (12) The main cable and connecting cable are compatible with the PDA. (13) Built-in lithium battery can be used more than 5 hours continuously. (14) PDAR program carry on CASE method analysis. (15) RCAPWAP program carry on match analysis automatically or manually.
Purpose SYR51+ rebar Location system is used to test rebar diameter, distribution, coating thickness in concrete. Specification JGJ/T152-2008 Performance Longer service life of the Connector Clip: The instrument has long service life because of using Lemo Connector Clip which comes from Swiss and uses for aircraft industry. Good quality of signal cable: The signal cable has long service life because of its flexible and substance. High precision and stability: The instrument can locate the steel-bar accurately and quickly. Longer service life of the sensor: Improve the service life by paste abrasion resistance allowance bottom of the sensor Single sensor: No-change sensor in test, switching between high and low test range can assure the precision of test data and the test depth. Display test information real-time: Display the test data directly to avoid man-made errors. Grid and section scan mode: Instrument can display steel bar distribution and scan steel bar without concrete boundary limited. Three-wheel steel-bar scan system: The system can assure scan path along line and the precision of test data. Powerful Windows data process and analysis software: Software can display analysis result by diagram. Test data can be export to word or Excel easily.
Purpose The instrument is used to test the degree of steel-bar corrosion in electrochemical method. Specification GB50204-2002 Performance 1. Two test mode. The potentiometry and gradient method is used to test steel-bar corrosion which fit for different working field. 2. Permanent reference electrode. Saturated CuSO4 solution is sealed up completely in reference electrode. Field test keeps clean, simple and pollution-free operations. 3. Automatic measure environmental temperature. Instrument design to contain a measure environmental temperature module, it can measure, record and display environmental temperature quickly no thermometers required. 4. Can save test date. Convenient for laborer data management. 5. Display test result intuitively. Display test result used icon mode, The icon color is more dark, the steel-bar corrosion is more serious. User can observe the corrosion degree intuitively. 6. Real USB transmission. Data can be transmitted to computer for future process and analysis. 7. Powerful data process and analysis software in windows. Software can display analysis result by spectrum and isoline. Test data can be export to word or excel easily. Performance 1. Test range: +/-2000 mV 2. Testing accuracy: +/-1 mV 3. Test point distance: 1~ 99cm setting 4. Applicable environmental: Temperature: -10? ~ +40? Dampness:
The series of products, producing highly pure hydrogen by utilizing SPE technology to electrolyze pure water (without adding alkali), are light, high efficient, energy-saving, and environmental protection. They are advanced technology patented products. Structural Features Zero polar distance and highly active SPE catalytic electrodes are used Plural-electrode and multiunit electrolysis cell structure with excellent chemical technological process properties of the mass and heat transfer Best choice of materials for multi-electrode and pluralist electrolysis cell with excellent properties of electrochemistry, corrosion resistance and bearing deactivation Complete, mature and credible automatic control system Functions and Characteristics Electrolysis of pure water(without adding alkali)to produce hydrogen with no corrosion and pollution, and the purity of hydrogen is extremely high Cell voltage is low, purification of hydrogen is high, cycle of changing desiccants is long Small electrolytic current, large output of hydrogen and voltage increasing quickly(3 to 5 minutes) Hydrogenation is produced with stable pressure and output, output of hydrogenation can be controlled according to the requirements, and automatic control technology is perfect and reliable Stable hydrogen pressure, stable current output, track with the using hydrogen automatically, and credibly automatic protection technology when there are deaquation, overpressure and water-jet Little noise ·+the fan needn't to work when use the generator·¼ The electrolysis efficiency is high , and power consumption is less Excellent seal performance Technical Parameters Type/Specifications Output Flow·+ml/min·¼0f+510 Output Pressure·+MPa·¼ 0.02-0.4 (Output under Stable Pressure·¼ Fluctuation Ratio of Output Pressure·+%·¼ 99.997/99.9996 Second Protective Pressure(MPa) 0.42 Power Voltage·+V·¼ 220 V f+15% 110f+15% 50f+60Hz Power Input·+W·¼
VAG 704 USB connector plugs into most modern laptops! (USB 1.1 or 2.0) 1. Compatible with the latest cars which requires a direct CAN connection for diagnostics including all Golf-5 platform cars and latest Audi A3, A6 and A8. 2. Protocol timing indistinguishable from a real VAG/VAS tool. Works reliably even with "difficult" control modules such as the 1991-1994 1Z Audi TDIS and the 1993-1994 Audi 2.6L with Hella ECU. 3. Built-In VAG-Saver functionality -- instantly alerts the user if either the K/K1 line or the L/K2 line is shorted to Ground or Battery. 4. Full support for dual-K lines found in "new" (B6/8E chassis Audi A4 and 2002+ Audi A6 -- no vas-6017 required -- no manual switches! 5. Fully backwards compatible with older cars using a single K-line or K plus L 6. VAG-COM work with cars that require direct CAN access for diagnostics. 7. CAN-BUS Interfaces also work with older vehicles that use the k-line.
VCM is special diagnose tool for Ford, but also testing Mazda vehicle. The Ford Integrated Diagnostic System (IDS) will be the only equipment that provides complete diagnostic coverage of current and future Ford, Lincoln and Mercury vehicles in North America. The IDS package replaces the Worldwide Diagnostic System (WDS). The IDS application will perform the identical functions of the WDS and allows dealership technicians to diagnose and service Ford, Lincoln, Mercury vehicles. As the new diagnostic tool,IDS will be required to perform diagnostics on future model year vehicles . One IDS Package is recommended for each WDS in the dealership. IDS VCM Accessories: Vehicle Communication Module (VCM) 16-Pin DLC Short Cable 16-Pin DLC Long Cable IDS 4m PC Ethernet-USB Host Cable DVD(Ford/Mazda) DVD(Land Rover/Jugar)
Plier Standard Packing
Rated Voltage 220V~ Rated Power 350W Rated Frequency 50Hz Drilling Capacity Steel 10mm Wood 20mm No-load Speed 0-3000r/min Standard Packing
SM 500 - Portable metallurgical microscope with on-off megnetic stand which can easily inspect metallography of large workspace on spot
SA 40 - Ultrasonic thickness gauge Measuring range: 1 to 225mm Resolution: 0.01mm 40 data memory
Hartip 3000 - A portable metal hardness tester with L, HRC, HRB, HB, shore and vickers scale Accurary: 0.5%(HL=800) Range : L200 - 960
Paint brush, artist brush, calligraphic brush, art tools.