Please click here to check who's online and chat with them.

Find Verified Laboratory Equipments Instruments Suppliers, Manufacturers and Wholesalers

Top Supplier Cities : Shenzhen   -   Guangzhou  
Jul-16-26
 Inquire Now  
Introduction:

The dual-tank cloud chamber can simulate key processes in natural cloud formation and precipitation, including the formation of supercooled water in clouds and the Bergeron Process under various natural conditions. It helps study hot issues of social concern such as clouds, precipitation, and atmospheric conditions (including smog, visibility, frost, freezing rain, etc.), and conduct targeted weather modification experiments.

Parameters:

1) Tank dimensions: m 11m (customizable)
2) Temperature range: -40C to 25C, accuracy ±0.2C
3) Pressure control range: 1 Pa to 0.12 MPa (A)
4) Liquid water content (LWC): 0.2â??3 g/m�³, accuracy ±20% (FS)
5) Mean volumetric diameter (MVD) of cloud and fog particles: 10-50 m, accuracy ±20% (FS)
6) Fog generation methods: High-pressure fogging, ultrasonic fogging, air-water mixture fogging, adiabatic expansion fogging, and steam fogging.
7) 3D digital simulation: The system incorporates 3D digital simulation, combining simulation calculations with cloud and fog experiments.
(All parameters above can be customized to meet specific user requirements.)
Jul-16-26
 Inquire Now  
Introduction:

The vehicle environmental simulation test chamber can simulate conditions encountered by vehicles during actual operation, such as rain, snow, sunlight, and driving speed.

Parameters:

1) Temperature range: -45C to 65C, control accuracy ±1C
2) Cooling rate: 25C to -45C - 3 hours (no load)
3) Heating rate: 25C to 65C 1 hour (no load)
4) High-temperature environment: temperature 35C to 65C, humidity 60%RH to 80%RH
5) Driving wind velocity: Adjustable from 0 to 120Km/h (i.e., the wind velocity at 30cm from the fan outlet, and the driving wind test is conducted when the chamber temperature is above -15).
6) Rainfall: 0-50 mm/h
7) Snowfall: 0-10 mm/h
8) Light intensity: 0-1200 W/m
9) Pressure range: The test chamber maintains a slight positive pressure (0-50 Pa).
(All parameters above can be customized to meet specific user requirements.)
Jul-16-26
 Inquire Now  
Introduction:
Ã?When developing high-precision weapons such as "modern weaponry and equipment," it is essential to adapt to various special environments. Dry sand and dust conditions exert a significant impact on the structural integrity and performance characteristics of equipment materials. Sand and dust testing is primarily used to evaluate the adaptability of equipment that may be exposed to dry sand and dust blowing conditions.

Parameters:

1) Ambient temperature control: 30C to 60C
2) Environmental humidity control: 30% RH
3) Sand blowing velocity: 18-29 m/s
4) Dust blowing velocity: 8.9 m/s
5) Sand blowing concentration: 0.18-2.7 g/m³
6) Dust blowing concentration: 0.18 g/m³
(All parameters above can be customized to meet specific user requirements.)
Jul-14-26
 Inquire Now  
Introduction:

Various haze environments can be simulated to explore the formation of haze and its impact on the environment. The test chamber can simultaneously control environmental conditions such as concentration, temperature, humidity, and light intensity within the simulated haze environment, while regulating the composition of various PM2.5 particles. The lab can simulate the formation of conventional fog, including various types of artificial fog, as well as naturally formed radiation fog. The test chamber can further simulate the simultaneous formation of haze and aerosol, or simulate aerosol formation independently.

Parameters:

1) Temperature range: -15C to 40C;
2. Temperature control accuracy: ±1
3) Humidity: 40%95% RH (-15C to 40C);
4) Humidity control accuracy: ±5% RH;
5) Suspended fog test: By using water vapor atomized by ultrasonic waves and combining it with an aerosol generation device, tiny fogdrops can be formed in the test chamber to simulate fog and haze in the natural environment.
(All parameters above can be customized to meet specific user requirements.)
Jul-14-26
 Inquire Now  
Introduction:

When aircraft operate within the Earth's atmosphere, they are subject to the influence of various natural climatic conditions within the atmosphere. The climate environment significantly impacts the physical, chemical, mechanical, and electrical properties of raw materials, components, and electromechanical products. During aircraft research, reliability testing under high-altitude climatic conditions must be conducted to ensure the safe and dependable operation of weaponry.

Functions:

1) Temperature and humidity control: Designed to withstand the extreme temperature conditions encountered by aircraft operating within the atmosphere.
2) Pressure control: The altitude variations experienced by aircraft during flight.
3) Solar radiation: The effects of solar radiation experienced by aircraft during flight on materials and personnel.
4) Cloudy and foggy weather: The effects of varying visibility conditions experienced by aircraft during flight.

Parameters:

1) Temperature range: -70C to 70C, uniformity: ±2C
2) Flight altitude: 0-30,000 m; altitude change: 10 m/s
3) Air pressure variation: 101 kPa to 2 kPa, control accuracy 5%
4) Solar radiation: Full spectrum 1353 W/m², irradiance tolerance: ±5 W/m²
 Infrared: wavelength range 0.4-0.78 ¼m, irradiance: 638 W/m², irradiance tolerance: ±10 W/m²
Ultraviolet: wavelength range 0.28-0.4 m, irradiance: 63 W/m², irradiance tolerance: ±25 W/m²
5) Cloudy and foggy environments: visibility 10m to 50,000m, error: 1,500m ±10%, >1,500m ±20%
6) Coupled conditions: temperature + atmospheric pressure; temperature + atmospheric pressure + solar radiation
(All parameters above can be customized to meet specific user requirements.)
49 Laboratory Equipments Instruments Suppliers
Short on time? Let Laboratory Equipments Instruments sellers contact you.
Jul-14-26
 Inquire Now  
Functions:

1) The equipment environmental simulation lab can offer targeted environmental reproductions based on actual testing requirements, enabling experiments to proceed regardless of season, time of day, availability, or location. It can simulate harsh and extreme environments at any time, making it widely used.
2) The equipment environmental simulation lab can conduct environmental tests at the material level, product level, complete machine level, system level, and even "human + machine" combination level, to study and assess the environmental adaptability and reliability of humans and equipment.
3) The equipment environmental simulation lab mainly reproduces various natural environments, including temperature and humidity, wind, rainfall, snowfall, icing, solar radiation, fog, salt spray, ultraviolet radiation, infrared radiation, high and low oxygen levels, high and low pressure, and other natural conditions.
4) The equipment environmental simulation lab can conduct comprehensive simulations ranging from single-parameter to multi-parameter coupling and from static to dynamic.
5) The equipment environmental simulation lab can conduct various equipment performance tests according to standard requirements, providing a basis for the type approval of some equipment or facilities, and also offering experimental data for equipment and product research and development.

Parameters:
1) Size: 300-1000m;
2) Temperature: -40C to 40C;
3) Humidity: 30-90% RH;
4) Wind velocity: 0-12 m/s;
5) Rainfall intensity: 0-30 mm/h, adjustable;
6) Snowfall intensity: 0-5 mm/h, adjustable;
7) Icing intensity: 0-2 mm/h, adjustable;
8) Solar radiation: 0-1200 W/m², adjustable;
9) Fog generation: Visibility 10m 30km, the space filled within half an hour;
10) Salt spray: Deposition rate 0-3 ml/80 cm;
11) Ultraviolet radiation: 0-64 W/m;
12) High and low oxygen levels: 5-30%;
13) High and low pressure: 50 kPa to atmospheric pressure
(All parameters above can be customized to meet specific user requirements.)
Jul-14-26
 Inquire Now  
Introduction:

This experimental apparatus has been developed to meet the needs of aerospace and military equipment. The high-altitude adaptability test and performance evaluation experiment for electromechanical equipment can be conducted. In medicine, it can be applied to high-altitude physiology, high-altitude athletic training, and clinical disease treatment.
 
Parameters:

1) Simulated altitude range: 100m to 30,000m
2) Temperature range: -60C to +85C
3) Humidity range: 10% to 95% RH
4) Atmospheric pressure range: 1 kPa to 100 kPa
5) Oxygen supply range: flow rate 350 L/min, pressure: 0-0.6 MPa
(All parameters above can be customized to meet specific user requirements.)
Jul-14-26
 Inquire Now  
Introduction:

This experimental apparatus has been developed to meet the needs of aerospace and equipment. The high-altitude adaptability test and performance evaluation experiment for electromechanical equipment can be conducted. In medicine, it can be applied to high-altitude physiology, high-altitude athletic training, and clinical disease treatment. Its primary characteristics are low temperature, low atmospheric pressure, oxygen deficiency, and high ultraviolet radiation.

Parameters:

1) Simulated altitude range: 100m to 20,000m
2) Temperature range: -60C to +85C
3) Temperature accuracy: ±0.5C
4) Humidity range: 10%-95% RH
5) Humidity accuracy: ±5% RH
6) Atmospheric pressure range: 100 kPa to 1 kPa
(All parameters above can be customized to meet specific user requirements.)
Jul-14-26
 Inquire Now  
Introduction:

Evaluate the adaptability of electrical, electronic, mechanical products, or materials to temperature cycling changes, as well as their suitability for storage and use under high-temperature or low temperature environmental conditions. Widely used in aerospace products, information electronics, instrumentation, materials, electrical engineering, and electronics industries.
 
Parameters:

1) Dimensions: 6m- 5m 4.6m (L W H) (customizable)
2) Temperature control: -40C to 30C, control stability ±0.8C, uniformity ±2.2C, measurement accuracy: ±0.5C
3) Humidity control: 30% to >95% RH, uniformity �±10% RH
4) Snowfall Control: 0-10 mm/h, covering the entire test chamber
5) Rainfall control: 0-40 mm/h, vertically downward direction
6) Airflow control: 0-5 m/s, airflow uniformity ±0.5 m/s
(All parameters above can be customized to meet specific user requirements.)
Sep-01-26
 Inquire Now  
Slow Strain Stress Rate Testing
What is Slow Strain Rate Testing (SSRT)?
Slow strain rate testing (SSRT) is a specialized method used to evaluate the corrosion behavior of materials, primarily metals. In this test, a specimen is subjected to elongation at a controlled, constant rate while exposed to specific environmental factors such as corrosive fluids or elevated temperatures. SSRT is also commonly referred to as� constant extension rate tensile (CERT) testing.
Understanding SSRT with UnitedTest
Slow strain rate testing� provides valuable insights into how materials respond to stress corrosion cracking (SCC) or fracture under particular environmental conditions. The test's accuracy depends on selecting an appropriate strain rate, as rates that are too high or too low may fail to reveal a materialâ??s true susceptibility to cracking.
While a standard strain rate is often applied for testing in different environments, the absence of cracking at that rate does not guarantee immunity. In some cases, SCC susceptibility becomes evident only at higher strain rates. The critical strain rate is defined as the rate at which stress corrosion cracking occurs most rapidly in a given environment. Established standard values exist for critical strain rates for metals such as:
�·� � Stainless steel in chloride or high-temperature water
�·� � Copper and magnesium alloys in nitrite solutions
�·� � Other alloys in specific corrosive environments
Overall, SSRT is an essential tool for mechanistic studies and for assessing the SCC susceptibility of various alloys, making it highly valuable in research and industrial applications.
More: https://www.unitedtest.com/products/
Jul-14-26
 Inquire Now  
Introduction:

The Power Line Icing test chamber can artificially simulate various complex natural climatic conditions, including temperature and humidity, wind velocity, rainfall, icing, and contamination. Tests of insulation contamination, condensation, rainfall, and icing flashover characteristics for 1000-kilovolt electrical equipment (insulator strings, disconnect switches, circuit breakers) can be conducted.

Parameters:

1) Dimensions: 22mx 22m x27m (L x W x H) (customizable)
2) Temperature: -40C to 60C, uniformity 2C
3) Humidity: 40%RH to 95%RH, control accuracy ±5%RH
4) Rainfall: 0 to 120mm/h, horizontal and vertical directions
5) Wind velocity: 0-10 m/s, measurement accuracy: ±0.2 m/s
6) Icing: 0-5 mm/h, capable of simulating three icing states: glaze, rime, and mixed rime
8) Contamination: The entire space filled within 30 minutes (cold fog/hot fog)
(All parameters above can be customized to meet specific user requirements)
Jun-20-12
Supplier From Beijing, China
 Inquire Now
Nov-12-07
Supplier From Beijing, Beijing, China
 Inquire Now
Jan-04-11
Nov-30-11
Supplier From Beijing, China
 Inquire Now
Feb-23-13
Supplier From Beijing, China
 Inquire Now
Aug-07-13
Supplier From Beijing, Fengtai, China
 Inquire Now
Aug-27-13
Supplier From Beijing, Hubei, China
 Inquire Now
Jun-28-13
Supplier From Beijing, Haidian District, China
 Inquire Now
Feb-13-14
Supplier From Beijing, China
 Inquire Now
Oct-23-15
Supplier From Beijing, Haidian, China
 Inquire Now
Jun-23-16
Supplier From Beijing, China, China
 Inquire Now
Sep-28-12
Supplier From Beijing, China
 Inquire Now
Jun-17-09
Supplier From Beijing, China
 Inquire Now
Dec-02-21
Supplier From Beijing, China
 Inquire Now
Apr-18-19
Supplier From Beijing, China
 Inquire Now
Mar-07-18
Supplier From Beijing, China
 Inquire Now
Jul-08-26
Supplier From Beijing, China
 Inquire Now
Jan-10-20
Supplier From Beijing, China
 Inquire Now
Jan-13-11
Supplier From Beijing, China
 Inquire Now
Mar-23-17
Supplier From Beijing, China
 Inquire Now
Aug-24-18
Supplier From Beijing, China
 Inquire Now
Mar-09-18
Supplier From Beijing, China
 Inquire Now
May-03-17
Supplier From Beijing, China
 Inquire Now
May-17-16
 Inquire Now  
Our adjustable pipettes have been widely used for sampling and dispensing liquids when accuracy, precision and convenience are required. They are available in 8 volumes ranging from 0.1 to 5000 µl, and use standard pipette tips. All Donglin pipettes have tip ejection, and are factory calibrated. The major features include:

·Ergonomic and lightweight design

·High accuracy and precision

·Easy-to-read digital volume display

·High chemical resistance of piston and ejector for durability

·One-handed volume setting for right-or left-handed users

·Easy Calibration technology provides calibration adjustments without tools
May-11-10
 Inquire Now  
A:high accuracy, low power consumption
B:compressor cooling
C:enviromental friendly,
D:adjustable temperature is 4~38

Size:439*480*510mm
Gw:25kg
Nov-22-07
 Inquire Now  
Quartz labware

Quartz glass has the characteristics of high purity, corrosion-resistant, temperature-resistant. So the instruments made of it are widely used in many fields.
Jan-04-24
Supplier From Beijing, China
 Inquire Now
Jan-13-11
 Inquire Now  
We are the biggest manufacture of colored borosilicate glass rod&tubing in China ,we are also the exclusive manufacture of colored borosilicate glass rod&tubing since 2002.
Main composition:
a) SiO2: 80 ¦0.5%
b) B2O3: 13 ¦0.2%
c) Al2O3: 2.4 ¦0.2%
d) Na2O (+K2O): 4.3 ¦0.2%
Chemical properties:
a) Coefficient of mean linear thermal expansion :
(20/300 ¦C):3.3¦0.1 (10-6K-1)
b) Transformation temperature: 525¦15¦C
c) Working point: 1,260 ¦20¦C
d) Softening point: 820 ¦10¦C
e) Density at 20¦C: 2.23g/cm¦
f) Hydrolytic resistance at 98¦C: ISO719-HGB1
g) Hydrolytic resistance at 121¦C: ISO720-HGA1
h) Acid resistance class: ISO1776-1
i) Alkali resistance class: ISO695-A2

We now can produce 11 colors: red, opaque black, opaque white, pink, purple, green, yellow, amber, dark blue, light blue and transparent black. Test shows they contain no heavy metal elements.

The size we can do : OD: 3.5ù300mm W.T:0.8ù12mm, length 3000mm.
OEM is welcomed.
Feb-23-13
 Inquire Now  
The model MT160 is a digital ultrasonic thickenss gauge. Based on the same operatinfg principles as SONAR, the instrument is capable of measuring the thickness of various materials with accuracy as high as 0.01 /0.1mm. It is suitable for a variety of metallice and non-metallic materials.
Capable of performing measurements on a wide range of material, including metals, plastic, ceramics, composites, epoxies, glass and other ultrasonic wave well-conductive materials.
Transducer models are available for special application, including for coarse grain material and high temperature applications.


CONFIGURATION

No
Item
Quantity
Note
Standard Configuration
1
Main body
1

2
Transducer
1
Model: N05/90¡ã
3
Couplant Bottle
1

4
Instrument Case
1

5
Alkaline battery
2
AA size
6
Operating Manual
1

7
Warranty Card
1
8



Optional Configuration
9
Transducer: N02

10
Transducer: N07

11
Transducer: HT5

12
Mini thermal printer
1

13
Print cable
1

14
DataPro for Thickness Gauge
1
For use on the PC
15
Communication Cable
1

bjxhhd-tech.com sinharef@126.com
Sep-17-18
 Inquire Now  
Mini portable hydrogen generator for Laboratory use:
Quick Details
Condition: New
Place of Origin: Beijing, China (Mainland)
Brand Name: CEI
Model Number: HGPM-300
Usage: Hydrogen
Production Rate: 100%
Voltage: Actual Voltage
Power(W): Actual Power
Weight: Actual Weight
Dimension(L*W*H): Actual Size
Certification: ISO9001,ISO14001,OHSAA18001,More than 20 Technology patents etc.
Warranty: 1 Year
After-sales Service Provided: Engineers available to service machinery overseas
Keyword: portable hydrogen generator
Application: Laboratory, Industry or energy
Purity: 99.999%
Capacity: 300ml/min
Material: Stainless Steel
Features: no alkaline addition
Pressure: 0.8Mpa
Type: PEM
Dew point: -50
Service life: more than 8 years
Mini portable hydrogen generator for Laboratory use
PEM micro pure water electrolysis hydrogen production equipment

We provide a series of Technology leading and mature PEM micro pure water electrolysis hydrogen production equipments. The hydrogen capacity is from 300mL/min-15L/min, the purity of hydrogen is 99.999%, the dew point is 50, and the pressure is up to 0.8MPa. This series of products integrate the world's leading and mature PEM electrolyzer and optimized process treatment and electronic control system (pressure differential system and balance system), to ensure that customers have excellent performance indicators and cost-effective products and services.
Advantages
1. Super pure hydrogen
the purity of the hydrogen is up to 99.999%
2. Product structure
Zero polar distance, highly active SPE (PEM) catalytic electrode pairs
Material selection of repolarization multicomponent electrolyzer with electrochemical properties, corrosion resistance, passivation resistance, etc. superior performances
3. product features
Pure water electrolysis (no alkaline addition) to produce hydrogen, no corrosion, no pollution, high hydrogen purity
The unit electrolyzer voltage is low, the internal resistance of the electrolyzer is small, no heat, the desiccant replacement cycle is long, and the hydrogen purity is high. Hydrogen steady pressure, steady flow output, and automatic tracking with the change of gas consumption with load, automatic protection technology is complete and reliable.
Steady pressure with high precision, water shortage, over-pressure, waterproof etc. automatic protection technologies are complete and reliable.
4. product application
GC (gas phase) gas and carrier gas
ELCD (conductivity detector) reaction gas
AED (Atomic emission spectroscopic detector) reaction gas
5. Custom design
We can provide customized design of hydrogen production equipment to optimize and integrate the existing factory facilities.
6. Safe operation
The system can monitor the security, performance and automation of the system, and allow remote monitoring and fault diagnosis.
Aug-10-16
Supplier From Beijing, Beijing, China
 Inquire Now
Apr-13-18
Supplier From Beijing, China
 Inquire Now
Aug-31-18
Supplier From Beijing, China
 Inquire Now
Feb-23-13
 Inquire Now  
Capable of performing measurements on a wide range of material.
Four transducer models.
Probe-Zero function, Sound-Velocity-Calibration function.
Two-Point Calibration function.
Two work modes: Single point mode and Scan mode.
Coupling status indicator showing the coupling status.
Auto sleep and auto power off function to conserve battery life.
Optional software to process the memory data on the PC.
Optional thermal mini-printer to print the measured data via RS232 port


CONFIGURATION

No
Item
Quantity
Note
Standard Configuration
1
Main body
1

2
Transducer
1
Model: N05/90¡ã
3
Couplant Bottle
1

4
Instrument Case
1

5
Screwdriver
1

6
Alkaline battery
2
AA size
7
Operating Manual
1
8
Warranty Card
1

Optional Configuration
9
Transducer: N02

10
Transducer: N07

11
Transducer: HT5

12
Mini thermal printer
1

13
Print cable
1

14
DataPro for Thickness Gauge
1
For use on the PC
15
Communication Cable
1


APPENDIX A: TRANSDUCER SELECTION
Model

Freq


MHZ

Diam


mm
Measuring Range Lower limit Description
N02 2.5 14

3.0mm¡«300.0mm£¨In Steel£©
40mm (in Gray Cast Iron HT200)
20 for thick, highly attenuating, or highly scattering materials
N05 5 10 1.2mm¡«230.0mm£¨In Steel£© ¦µ20mm¡Á3.0mm Normal Measurement
N05/90¡ã
5 10 1.2mm¡«230.0mm£¨In Steel£© ¦µ20mm¡Á3.0mm Normal Measurement
N07 7 6

0.75mm¡«80.0mm
£¨In Steel£©
¦µ15mm¡Á2.0mm For thin pipe wall or small curvature pipe wall measurement
HT5 5 12 3¡«200mm £¨In Steel£© 30 For high temperature (lower than 300¡ãC) measurement.

APPENDIX B: SOUND VELOCITY IN DIFFERENT MATERIALS
Material
Sound Velocity
In/us
m/s
Aluminum
0.250
6340-6400
Steel, common
0.233
5920
Steel, stainless
0.226
5740
Brass
0.173
4399
Copper
0.186
4720
Iron
0.233
5930
Cast Iron
0.173-0.229
4400-5820
Lead
0.094
2400
Nylon
0.105
2680
Silver
0.142
3607
Gold
0.128
3251
Zinc
0.164
4170
Titanium
0.236
5990
Tin
0.117
2960
Epoxy resin
0.100
2540
Ice
0.157
3988
Nickel
0.222
5639
Plexiglass
0.106
2692
Polystyrene
0.092
2337
Porcelain
0.230
5842
PVC
0.094
2388
Quartz glass
0.222
5639
Rubber, vulcanized
0.091
2311
Teflon
0.056
1422
Water
0.058
1473


CONFIGURATION

No
Item
Quantity
Note
Standard Configuration
1
Main body
1

2
Transducer
1
Model: N05/90¡ã
3
Couplant Bottle
1

4
Instrument Case
1

5
Screwdriver
1

6
Alkaline battery
2
AA size
7
Operating Manual
1
8
Warranty Card
1

Optional Configuration
9
Transducer: N02

10
Transducer: N07

11
Transducer: HT5

12
Mini thermal printer
1

13
Print cable
1

14
DataPro for Thickness Gauge
1
For use on the PC
15
Communication Cable
1

bjxhhd-tech.com sinharef@126.com
Aug-17-16

Tantalum Tube

$500 - $8.00K
MOQ: Not Specified
 Inquire Now  
Tantalum tube Introduction:

ShinTek can supply varieties of Refractory metal fabricated products, including Molybdenum (Mo), Tungsten (W), Tantalum (Ta), Niobium (Nb) fabricated products, e.g. ingot, forgings, rods, plates, sheets, foils and assembled products. They are very popular used in a wide of industries, including FPD/Touch sensor, high temperature furnace, medical / nuclear radiation shielding, aviation, specific tools, optical glass, semiconductor, chemical anti-corrosion, superconductor, etc...


Tantalum tube specifications:

1. Pure Tantalum Products
2. Purity: =99.95%, 99.99%
3. Dimension: Per customer's requirement;
4. Annealed

ShinTek can supply different types of Tantalum, including Tantalum Foils, Tantalum Sheets, Tantalum Plates, Tantalum Rods / Bars, Tantalum tube, Tantalum Forgings, Tantalum Ingots.
Feb-23-13
 Inquire Now  
With different external probes, the gauge can be applied to measuring thickness of non-magnetic coating on magnetic metal substrate, as well as non-conductive coating on non-magnetic metal substrate.
Five types of probes (F400, F1, F10, N1, CN02) are available for different application. F10 probe measures up to 10mm.
Two measuring modes: single or continuous, changeable.
Two calibration methods can be applied to the gauge; And the system error of the probe can be corrected with the basic probe calibration method.
Measured values and user information are shown on a large, easy-to-read LCD. A display back light ensures easy reading of screen data in poorly-lit conditions.
Measuring status indicator showing the measuring status.
n.


Measuring Principles
The gauge adopts two thickness-measuring methods: magnetic induction method and eddy current method.
insulating coatings on all non-ferrous metals and on austenitic stainless steels, e.g. paint, anodizing coatings, ceramics, etc. applied on aluminum, copper, zinc die-casting, brass, etc.


Working Conditions
Working temperature£º -10¡æ¡«£«50¡æ;
Storage temperature£º-30¡æ¡«£«60¡æ;
Relative humidity: ¡Ü90£¥;
The surrounding environment should avoid of vibration, strong magnetic field, corrosive medium and heavy dust.
Configuration

No.
Item
Quantity
Remarks


Standard
Config.
1
Main unit
1

2
Probe
1
F1 or N1
3
Calibration Foils
5 PCS

4
Zero plate
1
Iron or Aluminum
5
Instrument case
1

6
Manual
1

7
Alkaline Battery
2 PCS
AA size
8



Optional
Config.
9
Other type of probes


10
DataPro software
1
On CD
11
USB cable
1

bjxhhd-tech.com sinharef@126.com
Feb-23-13
 Inquire Now  
With different external probes, the gauge can be applied to measuring thickness of non-magnetic coating on magnetic metal substrate, as well as non-conductive coating on non-magnetic metal substrate.
Five types of probes (F400, F1, F10, N1, CN02) are available for different application. F10 probe measures up to 10mm.
Two measuring modes: single or continuous, changeable.
Two calibration methods can be applied to the gauge; And the system error of the probe can be corrected with the basic probe calibration method.
Measured values and user information are shown on a large, easy-to-read LCD. A display back light ensures easy reading of screen data in poorly-lit conditions.
Measuring status indicator showing the measuring status.
The gauges¡¯ user-friendly measuring system permits automatic storage of up to 1000 readings in one memory matrix for later statistical evaluation.


Measuring Principles
The gauge adopts two thickness-measuring methods: magnetic induction method and eddy current method.
insulating coatings on all non-ferrous metals and on austenitic stainless steels, e.g. paint, anodizing coatings, ceramics, etc. applied on aluminum, copper, zinc die-casting, brass, etc.


Working Conditions
Working temperature£º -10¡æ¡«£«50¡æ;
Storage temperature£º-30¡æ¡«£«60¡æ;
Relative humidity: ¡Ü90£¥;
The surrounding environment should avoid of vibration, strong magnetic field, corrosive medium and heavy dust.
Configuration

No.
Item
Quantity
Remarks


Standard
Config.
1
Main unit
1

2
Probe
1
F1 or N1
3
Calibration Foils
5 PCS

4
Zero plate
1
Iron or Aluminum
5
Instrument case
1

6
Manual
1

7
Alkaline Battery
2 PCS
AA size
8



Optional
Config.
9
Other type of probes


10
DataPro software
1
On CD
11
USB cable
1
Feb-28-25
Supplier From beijing, China
 Inquire Now
49 Laboratory Equipments Instruments Suppliers
Short on time? Let Laboratory Equipments Instruments sellers contact you.
  • First page
  • Next
See what buyers and suppliers are discussing in Laboratory Equipments Instruments import export community