Please click here to check who's online and chat with them.

Mct200 Coating Thickness Gauge

Supplier From China
Feb-23-13

With different external probes, the gauge can be applied to measuring thickness of non-magnetic coating on magnetic metal substrate, as well as non-conductive coating on non-magnetic metal substrate.
Five types of probes (F400, F1, F10, N1, CN02) are available for different application. F10 probe measures up to 10mm.
Two measuring modes: single or continuous, changeable.
Two calibration methods can be applied to the gauge; And the system error of the probe can be corrected with the basic probe calibration method.
Measured values and user information are shown on a large, easy-to-read LCD. A display back light ensures easy reading of screen data in poorly-lit conditions.
Measuring status indicator showing the measuring status.
n.


Measuring Principles
The gauge adopts two thickness-measuring methods: magnetic induction method and eddy current method.
insulating coatings on all non-ferrous metals and on austenitic stainless steels, e.g. paint, anodizing coatings, ceramics, etc. applied on aluminum, copper, zinc die-casting, brass, etc.


Working Conditions
Working temperature£º -10¡æ¡«£«50¡æ;
Storage temperature£º-30¡æ¡«£«60¡æ;
Relative humidity: ¡Ü90£¥;
The surrounding environment should avoid of vibration, strong magnetic field, corrosive medium and heavy dust.
Configuration

No.
Item
Quantity
Remarks


Standard
Config.
1
Main unit
1

2
Probe
1
F1 or N1
3
Calibration Foils
5 PCS

4
Zero plate
1
Iron or Aluminum
5
Instrument case
1

6
Manual
1

7
Alkaline Battery
2 PCS
AA size
8



Optional
Config.
9
Other type of probes


10
DataPro software
1
On CD
11
USB cable
1

bjxhhd-tech.com sinharef@126.com


Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Mct200 Coating Thickness Gauge

Feb-23-13
With different external probes, the gauge can be applied to measuring thickness of non-magnetic coating on magnetic metal substrate, as well as non-conductive coating on non-magnetic metal substrate.
Five types of probes (F400, F1, F10, N1, CN02) are available for different application. F10 probe measures up to 10mm.
Two measuring modes: single or continuous, changeable.
Two calibration methods can be applied to the gauge; And the system error of the probe can be corrected with the basic probe calibration method.
Measured values and user information are shown on a large, easy-to-read LCD. A display back light ensures easy reading of screen data in poorly-lit conditions.
Measuring status indicator showing the measuring status.
The gauges¡¯ user-friendly measuring system permits automatic storage of up to 1000 readings in one memory matrix for later statistical evaluation.


Measuring Principles
The gauge adopts two thickness-measuring methods: magnetic induction method and eddy current method.
insulating coatings on all non-ferrous metals and on austenitic stainless steels, e.g. paint, anodizing coatings, ceramics, etc. applied on aluminum, copper, zinc die-casting, brass, etc.


Working Conditions
Working temperature£º -10¡æ¡«£«50¡æ;
Storage temperature£º-30¡æ¡«£«60¡æ;
Relative humidity: ¡Ü90£¥;
The surrounding environment should avoid of vibration, strong magnetic field, corrosive medium and heavy dust.
Configuration

No.
Item
Quantity
Remarks


Standard
Config.
1
Main unit
1

2
Probe
1
F1 or N1
3
Calibration Foils
5 PCS

4
Zero plate
1
Iron or Aluminum
5
Instrument case
1

6
Manual
1

7
Alkaline Battery
2 PCS
AA size
8



Optional
Config.
9
Other type of probes


10
DataPro software
1
On CD
11
USB cable
1
GOLD Member
Apr-26-21

Greenhouse Glass

$3 - $6
MOQ: 1000  Square Meters
Sample Available
JHG offer differnt sizes of tempered glass, annealed glass to meet the inquiry for greenhouse ,hobby garden ,
Glass thickness is 3mm/3.2mm/4mm/5mm
Glass items : clear float glass ,acid etched glass ,diffused glass high haze glass ,AR coated glass
Max LT >99%
Max haze>50%
GOLD Member
May-24-21

Solar Glass

$4.50 - $9.90
MOQ: 1000  Square Meters
Sample Available
SOLAR GLASS
JHG solar glass including texture glass and flat glass ,it is the nice performance low iron glass with high solar transmittance, and low reflection .
After tempered, it will be the ideal choice for photovoltaics, solar thermal collector ,and greenhouse .

Size
Maximum Size:1665*2200mm
Minimum Size: 300*300mm

Specifiction

Main thickness 2-5mm
Dimension tolerance �?�±1.0mm
Thickness tolerance �?�±0.2mm
Diagonal tolerance 0.2%
Overall bow <0.2%
Iron content 110ppm
Solar transmittance from 91.5-99%
(wavelength rang 380-1100mm)
Hardness H

Main glass series
2-5mm Tempered low iron float glass
2-5mm Tempered low iron texure/mistlite glass
2-5mm AR coating glass
2-5mm High hazed tempered glass
2-5mm silk printed tempered glass
GOLD Member
Dec-15-23
Supplier From Zibo, Shandong, China
JHG tinted glass is produced by metal oxides to the float glass. The colour may be transferred in the series of blue, green, grey, bronze flexibly. The performance of visible light, privacy and solar heat transmission will be changed arrording the colour change. Different tinted glass offers varied application possibility-from interior partitions, to home appliance, to furniture, to facades and auto field. Reflective glass is float glass with a metallic coating that cuts off solar heat.The coating film may provide mirror effect, preventing visibility from outside and preserving privacy. JHG mainly offer 2 kinds of reflective glass. Hard reflective glass (on line) includes blue, green, grey, bronze, pink, silver colour, Soft reflective glass (off line) includes golden, silver, purple colur.
Specification

Sizes:1220*1830/1830*2440/1650*2140/2140*3300/2140*3660/2440*3660/2250*3660/3300*4500/5100/6000mm
Thickness: 3-12mm

Quality standard

GB11614-2009/SGCC/EN 572
Feb-23-13
Capable of performing measurements on a wide range of material.
Four transducer models.
Probe-Zero function, Sound-Velocity-Calibration function.
Two-Point Calibration function.
Two work modes: Single point mode and Scan mode.
Coupling status indicator showing the coupling status.
Auto sleep and auto power off function to conserve battery life.
Optional software to process the memory data on the PC.
Optional thermal mini-printer to print the measured data via RS232 port


CONFIGURATION

No
Item
Quantity
Note
Standard Configuration
1
Main body
1

2
Transducer
1
Model: N05/90¡ã
3
Couplant Bottle
1

4
Instrument Case
1

5
Screwdriver
1

6
Alkaline battery
2
AA size
7
Operating Manual
1
8
Warranty Card
1

Optional Configuration
9
Transducer: N02

10
Transducer: N07

11
Transducer: HT5

12
Mini thermal printer
1

13
Print cable
1

14
DataPro for Thickness Gauge
1
For use on the PC
15
Communication Cable
1


APPENDIX A: TRANSDUCER SELECTION
Model

Freq


MHZ

Diam


mm
Measuring Range Lower limit Description
N02 2.5 14

3.0mm¡«300.0mm£¨In Steel£©
40mm (in Gray Cast Iron HT200)
20 for thick, highly attenuating, or highly scattering materials
N05 5 10 1.2mm¡«230.0mm£¨In Steel£© ¦µ20mm¡Á3.0mm Normal Measurement
N05/90¡ã
5 10 1.2mm¡«230.0mm£¨In Steel£© ¦µ20mm¡Á3.0mm Normal Measurement
N07 7 6

0.75mm¡«80.0mm
£¨In Steel£©
¦µ15mm¡Á2.0mm For thin pipe wall or small curvature pipe wall measurement
HT5 5 12 3¡«200mm £¨In Steel£© 30 For high temperature (lower than 300¡ãC) measurement.

APPENDIX B: SOUND VELOCITY IN DIFFERENT MATERIALS
Material
Sound Velocity
In/us
m/s
Aluminum
0.250
6340-6400
Steel, common
0.233
5920
Steel, stainless
0.226
5740
Brass
0.173
4399
Copper
0.186
4720
Iron
0.233
5930
Cast Iron
0.173-0.229
4400-5820
Lead
0.094
2400
Nylon
0.105
2680
Silver
0.142
3607
Gold
0.128
3251
Zinc
0.164
4170
Titanium
0.236
5990
Tin
0.117
2960
Epoxy resin
0.100
2540
Ice
0.157
3988
Nickel
0.222
5639
Plexiglass
0.106
2692
Polystyrene
0.092
2337
Porcelain
0.230
5842
PVC
0.094
2388
Quartz glass
0.222
5639
Rubber, vulcanized
0.091
2311
Teflon
0.056
1422
Water
0.058
1473


CONFIGURATION

No
Item
Quantity
Note
Standard Configuration
1
Main body
1

2
Transducer
1
Model: N05/90¡ã
3
Couplant Bottle
1

4
Instrument Case
1

5
Screwdriver
1

6
Alkaline battery
2
AA size
7
Operating Manual
1
8
Warranty Card
1

Optional Configuration
9
Transducer: N02

10
Transducer: N07

11
Transducer: HT5

12
Mini thermal printer
1

13
Print cable
1

14
DataPro for Thickness Gauge
1
For use on the PC
15
Communication Cable
1

bjxhhd-tech.com sinharef@126.com
Feb-23-13
The model MT160 is a digital ultrasonic thickenss gauge. Based on the same operatinfg principles as SONAR, the instrument is capable of measuring the thickness of various materials with accuracy as high as 0.01 /0.1mm. It is suitable for a variety of metallice and non-metallic materials.
Capable of performing measurements on a wide range of material, including metals, plastic, ceramics, composites, epoxies, glass and other ultrasonic wave well-conductive materials.
Transducer models are available for special application, including for coarse grain material and high temperature applications.


CONFIGURATION

No
Item
Quantity
Note
Standard Configuration
1
Main body
1

2
Transducer
1
Model: N05/90¡ã
3
Couplant Bottle
1

4
Instrument Case
1

5
Alkaline battery
2
AA size
6
Operating Manual
1

7
Warranty Card
1
8



Optional Configuration
9
Transducer: N02

10
Transducer: N07

11
Transducer: HT5

12
Mini thermal printer
1

13
Print cable
1

14
DataPro for Thickness Gauge
1
For use on the PC
15
Communication Cable
1

bjxhhd-tech.com sinharef@126.com
Aug-02-10
Supplier From Vadodara, Gujarat, India
VERIFIED
Apr-12-16
Supported by an industrious team of professionals, we are engaged in manufacturing Vertical Autoclave. The Vertical Autoclave, are manufactured, as per the industrial norms. Known for the high performance, the Vertical Autoclave, provided by us, have great demand across the global market. We provide the Vertical Autoclave in varied technical specifications to meet the diverse needs of the industries.

Features

,Vertical - Model
,Useful for sterilization
,Double walled in construction
,Inner made of thick gauges stainless steel with argon welding
,Outer made of thick gauge stainless steel with 3 Nos. metal casting legs
,Foot lifting facility for opening of lid
,Silicon Gasket to minimize the heat loss
,Stainless Steel made wing nuts for tightening of lid
,Selection of Regular, Semi - Automatic & Fully Automatic
,Solid State Digital Temperature Controller with timer
VERIFIED
Jun-16-21
Box dimension - 1000mm x 750mm x 750mm
Box Material - Stainless steel 304 L box with mirror finish inside brushed finished outside
Acid resistant
Box panel/window Openable Front window with polycarbonate an extra coating for chemical and scratch resistance One

Feed through electrical single phase 220 V - 16 A
Attainable purity < 100ppm H2O and < 500ppm O2 at complete pressure range.
O2 = 20 l , H2O = 960 g
Filtration HEPA : particles
Glove Ports - Glove ports, 220mm diameter and should be O ring sealed
Gloves Materials
Gloves Piercan USA make Neoprene, or Butyl
Dust filter - 0.3 micron Dust filter. HEPA Filter
0.3 micron HEPA, H13 or H14
Gas Purifier - Molecular sieves, Activated Carbon, Charcoal chamber with high efficient O2 ,H2O adsorbent One each

Shelves - Height Adjustable, Acrylic Stainless Steel shelves
Three/ Yes
Box Pressure Control -+15 mbar to -15mbar. Automatic pressure control. Yes
Box Lamp -One front mounted fluorescent lamp one inside
Yes
Antechamber Type Cylindrical, 300 mm diameter, Length 600mm (inside dimensions) Material stainless steel, thickness 2.5mm Inside surface brushed finish Sliding tray stainless steel Doors SS thickness 10mm Door lock easy to operate, spindle lock Pressure gauge, monometer: analog display Vacuum/ Refill process.

Regeneration Below 5% loss Complete automated or manual operation with foot switch Yes
Sensors Solid state oxygen sensor with 0- 1000 ppm & Solid state moisture sensor with 0-500 ppm Auto purge PLC controlled via system control panel.
PLC Program Logi Control with integrated control with external display unit 10 One Yes
Vacuum Pump 740 mm HG with fittings (Optional) High Vacuum Pump: Oil sealed vacuum pump â?? 150 lpm,Vacuum level : 5x10ï?­2mbar
Type rotary vane pump, dual stage, Oil mist filter, Oil recirculation, Automatic gas ballast control, 10 m3/h Optional facility for automatically turning off the vacuum pump when the antechamber is not in use
One
Recirculation Pump Optional Re circulating purified gases pro rata basis 20m3/
per hour
Service Support - Efficient service facilities with trained engineers at your place
warranty
One years comprehensive onsite warranty.

Verification Status