With different external probes, the gauge can be applied to measuring thickness of non-magnetic coating on magnetic metal substrate, as well as non-conductive coating on non-magnetic metal substrate.
Five types of probes (F400, F1, F10, N1, CN02) are available for different application. F10 probe measures up to 10mm.
Two measuring modes: single or continuous, changeable.
Two calibration methods can be applied to the gauge; And the system error of the probe can be corrected with the basic probe calibration method.
Measured values and user information are shown on a large, easy-to-read LCD. A display back light ensures easy reading of screen data in poorly-lit conditions.
Measuring status indicator showing the measuring status.
n.
Measuring Principles
The gauge adopts two thickness-measuring methods: magnetic induction method and eddy current method.
insulating coatings on all non-ferrous metals and on austenitic stainless steels, e.g. paint, anodizing coatings, ceramics, etc. applied on aluminum, copper, zinc die-casting, brass, etc.
Working Conditions
Working temperature£º -10¡æ¡«£«50¡æ;
Storage temperature£º-30¡æ¡«£«60¡æ;
Relative humidity: ¡Ü90£¥;
The surrounding environment should avoid of vibration, strong magnetic field, corrosive medium and heavy dust.
Configuration
No.
Item
Quantity
Remarks
Standard
Config.
1
Main unit
1
2
Probe
1
F1 or N1
3
Calibration Foils
5 PCS
4
Zero plate
1
Iron or Aluminum
5
Instrument case
1
6
Manual
1
7
Alkaline Battery
2 PCS
AA size
8
Optional
Config.
9
Other type of probes
10
DataPro software
1
On CD
11
USB cable
1
bjxhhd-tech.com sinharef@126.com
With different external probes, the gauge can be applied to measuring thickness of non-magnetic coating on magnetic metal substrate, as well as non-conductive coating on non-magnetic metal substrate. Five types of probes (F400, F1, F10, N1, CN02) are available for different application. F10 probe measures up to 10mm. Two measuring modes: single or continuous, changeable. Two calibration methods can be applied to the gauge; And the system error of the probe can be corrected with the basic probe calibration method. Measured values and user information are shown on a large, easy-to-read LCD. A display back light ensures easy reading of screen data in poorly-lit conditions. Measuring status indicator showing the measuring status. The gauges¡¯ user-friendly measuring system permits automatic storage of up to 1000 readings in one memory matrix for later statistical evaluation. Measuring Principles The gauge adopts two thickness-measuring methods: magnetic induction method and eddy current method. insulating coatings on all non-ferrous metals and on austenitic stainless steels, e.g. paint, anodizing coatings, ceramics, etc. applied on aluminum, copper, zinc die-casting, brass, etc. Working Conditions Working temperature£º -10¡æ¡«£«50¡æ; Storage temperature£º-30¡æ¡«£«60¡æ; Relative humidity: ¡Ü90£¥; The surrounding environment should avoid of vibration, strong magnetic field, corrosive medium and heavy dust. Configuration No. Item Quantity Remarks Standard Config. 1 Main unit 1 2 Probe 1 F1 or N1 3 Calibration Foils 5 PCS 4 Zero plate 1 Iron or Aluminum 5 Instrument case 1 6 Manual 1 7 Alkaline Battery 2 PCS AA size 8 Optional Config. 9 Other type of probes 10 DataPro software 1 On CD 11 USB cable 1
JHG tinted glass is produced by metal oxides to the float glass. The colour may be transferred in the series of blue, green, grey, bronze flexibly. The performance of visible light, privacy and solar heat transmission will be changed arrording the colour change. Different tinted glass offers varied application possibility-from interior partitions, to home appliance, to furniture, to facades and auto field. Reflective glass is float glass with a metallic coating that cuts off solar heat.The coating film may provide mirror effect, preventing visibility from outside and preserving privacy. JHG mainly offer 2 kinds of reflective glass. Hard reflective glass (on line) includes blue, green, grey, bronze, pink, silver colour, Soft reflective glass (off line) includes golden, silver, purple colur. Specification Sizes:1220*1830/1830*2440/1650*2140/2140*3300/2140*3660/2440*3660/2250*3660/3300*4500/5100/6000mm Thickness: 3-12mm Quality standard GB11614-2009/SGCC/EN 572
SOLAR GLASS JHG solar glass including texture glass and flat glass ,it is the nice performance low iron glass with high solar transmittance, and low reflection . After tempered, it will be the ideal choice for photovoltaics, solar thermal collector ,and greenhouse . Size Maximum Size:1665*2200mm Minimum Size: 300*300mm Specifiction Main thickness 2-5mm Dimension tolerance �?�±1.0mm Thickness tolerance �?�±0.2mm Diagonal tolerance 0.2% Overall bow
Capable of performing measurements on a wide range of material. Four transducer models. Probe-Zero function, Sound-Velocity-Calibration function. Two-Point Calibration function. Two work modes: Single point mode and Scan mode. Coupling status indicator showing the coupling status. Auto sleep and auto power off function to conserve battery life. Optional software to process the memory data on the PC. Optional thermal mini-printer to print the measured data via RS232 port CONFIGURATION No Item Quantity Note Standard Configuration 1 Main body 1 2 Transducer 1 Model: N05/90¡ã 3 Couplant Bottle 1 4 Instrument Case 1 5 Screwdriver 1 6 Alkaline battery 2 AA size 7 Operating Manual 1 8 Warranty Card 1 Optional Configuration 9 Transducer: N02 10 Transducer: N07 11 Transducer: HT5 12 Mini thermal printer 1 13 Print cable 1 14 DataPro for Thickness Gauge 1 For use on the PC 15 Communication Cable 1 APPENDIX A: TRANSDUCER SELECTION Model Freq MHZ Diam mm Measuring Range Lower limit Description N02 2.5 14 3.0mm¡«300.0mm£¨In Steel£© 40mm (in Gray Cast Iron HT200) 20 for thick, highly attenuating, or highly scattering materials N05 5 10 1.2mm¡«230.0mm£¨In Steel£© ¦µ20mm¡Á3.0mm Normal Measurement N05/90¡ã 5 10 1.2mm¡«230.0mm£¨In Steel£© ¦µ20mm¡Á3.0mm Normal Measurement N07 7 6 0.75mm¡«80.0mm £¨In Steel£© ¦µ15mm¡Á2.0mm For thin pipe wall or small curvature pipe wall measurement HT5 5 12 3¡«200mm £¨In Steel£© 30 For high temperature (lower than 300¡ãC) measurement. APPENDIX B: SOUND VELOCITY IN DIFFERENT MATERIALS Material Sound Velocity In/us m/s Aluminum 0.250 6340-6400 Steel, common 0.233 5920 Steel, stainless 0.226 5740 Brass 0.173 4399 Copper 0.186 4720 Iron 0.233 5930 Cast Iron 0.173-0.229 4400-5820 Lead 0.094 2400 Nylon 0.105 2680 Silver 0.142 3607 Gold 0.128 3251 Zinc 0.164 4170 Titanium 0.236 5990 Tin 0.117 2960 Epoxy resin 0.100 2540 Ice 0.157 3988 Nickel 0.222 5639 Plexiglass 0.106 2692 Polystyrene 0.092 2337 Porcelain 0.230 5842 PVC 0.094 2388 Quartz glass 0.222 5639 Rubber, vulcanized 0.091 2311 Teflon 0.056 1422 Water 0.058 1473 CONFIGURATION No Item Quantity Note Standard Configuration 1 Main body 1 2 Transducer 1 Model: N05/90¡ã 3 Couplant Bottle 1 4 Instrument Case 1 5 Screwdriver 1 6 Alkaline battery 2 AA size 7 Operating Manual 1 8 Warranty Card 1 Optional Configuration 9 Transducer: N02 10 Transducer: N07 11 Transducer: HT5 12 Mini thermal printer 1 13 Print cable 1 14 DataPro for Thickness Gauge 1 For use on the PC 15 Communication Cable 1 bjxhhd-tech.com sinharef@126.com
The model MT160 is a digital ultrasonic thickenss gauge. Based on the same operatinfg principles as SONAR, the instrument is capable of measuring the thickness of various materials with accuracy as high as 0.01 /0.1mm. It is suitable for a variety of metallice and non-metallic materials. Capable of performing measurements on a wide range of material, including metals, plastic, ceramics, composites, epoxies, glass and other ultrasonic wave well-conductive materials. Transducer models are available for special application, including for coarse grain material and high temperature applications. CONFIGURATION No Item Quantity Note Standard Configuration 1 Main body 1 2 Transducer 1 Model: N05/90¡ã 3 Couplant Bottle 1 4 Instrument Case 1 5 Alkaline battery 2 AA size 6 Operating Manual 1 7 Warranty Card 1 8 Optional Configuration 9 Transducer: N02 10 Transducer: N07 11 Transducer: HT5 12 Mini thermal printer 1 13 Print cable 1 14 DataPro for Thickness Gauge 1 For use on the PC 15 Communication Cable 1 bjxhhd-tech.com sinharef@126.com
Supported by an industrious team of professionals, we are engaged in manufacturing Vertical Autoclave. The Vertical Autoclave, are manufactured, as per the industrial norms. Known for the high performance, the Vertical Autoclave, provided by us, have great demand across the global market. We provide the Vertical Autoclave in varied technical specifications to meet the diverse needs of the industries. Features ,Vertical - Model ,Useful for sterilization ,Double walled in construction ,Inner made of thick gauges stainless steel with argon welding ,Outer made of thick gauge stainless steel with 3 Nos. metal casting legs ,Foot lifting facility for opening of lid ,Silicon Gasket to minimize the heat loss ,Stainless Steel made wing nuts for tightening of lid ,Selection of Regular, Semi - Automatic & Fully Automatic ,Solid State Digital Temperature Controller with timer
Supplier: Machineries and dust collector spares for cement industries i.e. Filter bags, valves (solenoid valves, butterfly valves, sequential/timer cards), cages for bag filter, packaging materials i.e. Glass bottles, aluminum aerosol cans, aluminum tin plate cans, coated paper, specific raw materials for ceramic industries., other raw materials for food industries and perfume industries and some time for pharma industries., fuel energy products i.E. Palm kernel shell, coconut shell
Box dimension - 1000mm x 750mm x 750mm Box Material - Stainless steel 304 L box with mirror finish inside brushed finished outside Acid resistant Box panel/window Openable Front window with polycarbonate an extra coating for chemical and scratch resistance One Feed through electrical single phase 220 V - 16 A Attainable purity < 100ppm H2O and < 500ppm O2 at complete pressure range. O2 = 20 l , H2O = 960 g Filtration HEPA : particles Glove Ports - Glove ports, 220mm diameter and should be O ring sealed Gloves Materials Gloves Piercan USA make Neoprene, or Butyl Dust filter - 0.3 micron Dust filter. HEPA Filter 0.3 micron HEPA, H13 or H14 Gas Purifier - Molecular sieves, Activated Carbon, Charcoal chamber with high efficient O2 ,H2O adsorbent One each Shelves - Height Adjustable, Acrylic Stainless Steel shelves Three/ Yes Box Pressure Control -+15 mbar to -15mbar. Automatic pressure control. Yes Box Lamp -One front mounted fluorescent lamp one inside Yes Antechamber Type Cylindrical, 300 mm diameter, Length 600mm (inside dimensions) Material stainless steel, thickness 2.5mm Inside surface brushed finish Sliding tray stainless steel Doors SS thickness 10mm Door lock easy to operate, spindle lock Pressure gauge, monometer: analog display Vacuum/ Refill process. Regeneration Below 5% loss Complete automated or manual operation with foot switch Yes Sensors Solid state oxygen sensor with 0- 1000 ppm & Solid state moisture sensor with 0-500 ppm Auto purge PLC controlled via system control panel. PLC Program Logi Control with integrated control with external display unit 10 One Yes Vacuum Pump 740 mm HG with fittings (Optional) High Vacuum Pump: Oil sealed vacuum pump â?? 150 lpm,Vacuum level : 5x10ï?Â2mbar Type rotary vane pump, dual stage, Oil mist filter, Oil recirculation, Automatic gas ballast control, 10 m3/h Optional facility for automatically turning off the vacuum pump when the antechamber is not in use One Recirculation Pump Optional Re circulating purified gases pro rata basis 20m3/ per hour Service Support - Efficient service facilities with trained engineers at your place warranty One years comprehensive onsite warranty.