Capable of performing measurements on a wide range of material.
Four transducer models.
Probe-Zero function, Sound-Velocity-Calibration function.
Two-Point Calibration function.
Two work modes: Single point mode and Scan mode.
Coupling status indicator showing the coupling status.
Auto sleep and auto power off function to conserve battery life.
Optional software to process the memory data on the PC.
Optional thermal mini-printer to print the measured data via RS232 port
CONFIGURATION
No
Item
Quantity
Note
Standard Configuration
1
Main body
1
2
Transducer
1
Model: N05/90¡ã
3
Couplant Bottle
1
4
Instrument Case
1
5
Screwdriver
1
6
Alkaline battery
2
AA size
7
Operating Manual
1
8
Warranty Card
1
Optional Configuration
9
Transducer: N02
10
Transducer: N07
11
Transducer: HT5
12
Mini thermal printer
1
13
Print cable
1
14
DataPro for Thickness Gauge
1
For use on the PC
15
Communication Cable
1
APPENDIX A: TRANSDUCER SELECTION
Model
Freq
MHZ
Diam
mm
Measuring Range Lower limit Description
N02 2.5 14
3.0mm¡«300.0mm£¨In Steel£©
40mm (in Gray Cast Iron HT200)
20 for thick, highly attenuating, or highly scattering materials
N05 5 10 1.2mm¡«230.0mm£¨In Steel£© ¦µ20mm¡Á3.0mm Normal Measurement
N05/90¡ã
5 10 1.2mm¡«230.0mm£¨In Steel£© ¦µ20mm¡Á3.0mm Normal Measurement
N07 7 6
0.75mm¡«80.0mm
£¨In Steel£©
¦µ15mm¡Á2.0mm For thin pipe wall or small curvature pipe wall measurement
HT5 5 12 3¡«200mm £¨In Steel£© 30 For high temperature (lower than 300¡ãC) measurement.
APPENDIX B: SOUND VELOCITY IN DIFFERENT MATERIALS
Material
Sound Velocity
In/us
m/s
Aluminum
0.250
6340-6400
Steel, common
0.233
5920
Steel, stainless
0.226
5740
Brass
0.173
4399
Copper
0.186
4720
Iron
0.233
5930
Cast Iron
0.173-0.229
4400-5820
Lead
0.094
2400
Nylon
0.105
2680
Silver
0.142
3607
Gold
0.128
3251
Zinc
0.164
4170
Titanium
0.236
5990
Tin
0.117
2960
Epoxy resin
0.100
2540
Ice
0.157
3988
Nickel
0.222
5639
Plexiglass
0.106
2692
Polystyrene
0.092
2337
Porcelain
0.230
5842
PVC
0.094
2388
Quartz glass
0.222
5639
Rubber, vulcanized
0.091
2311
Teflon
0.056
1422
Water
0.058
1473
CONFIGURATION
No
Item
Quantity
Note
Standard Configuration
1
Main body
1
2
Transducer
1
Model: N05/90¡ã
3
Couplant Bottle
1
4
Instrument Case
1
5
Screwdriver
1
6
Alkaline battery
2
AA size
7
Operating Manual
1
8
Warranty Card
1
Optional Configuration
9
Transducer: N02
10
Transducer: N07
11
Transducer: HT5
12
Mini thermal printer
1
13
Print cable
1
14
DataPro for Thickness Gauge
1
For use on the PC
15
Communication Cable
1
bjxhhd-tech.com sinharef@126.com
The model MT160 is a digital ultrasonic thickenss gauge. Based on the same operatinfg principles as SONAR, the instrument is capable of measuring the thickness of various materials with accuracy as high as 0.01 /0.1mm. It is suitable for a variety of metallice and non-metallic materials. Capable of performing measurements on a wide range of material, including metals, plastic, ceramics, composites, epoxies, glass and other ultrasonic wave well-conductive materials. Transducer models are available for special application, including for coarse grain material and high temperature applications. CONFIGURATION No Item Quantity Note Standard Configuration 1 Main body 1 2 Transducer 1 Model: N05/90¡ã 3 Couplant Bottle 1 4 Instrument Case 1 5 Alkaline battery 2 AA size 6 Operating Manual 1 7 Warranty Card 1 8 Optional Configuration 9 Transducer: N02 10 Transducer: N07 11 Transducer: HT5 12 Mini thermal printer 1 13 Print cable 1 14 DataPro for Thickness Gauge 1 For use on the PC 15 Communication Cable 1 bjxhhd-tech.com sinharef@126.com
With different external probes, the gauge can be applied to measuring thickness of non-magnetic coating on magnetic metal substrate, as well as non-conductive coating on non-magnetic metal substrate. Five types of probes (F400, F1, F10, N1, CN02) are available for different application. F10 probe measures up to 10mm. Two measuring modes: single or continuous, changeable. Two calibration methods can be applied to the gauge; And the system error of the probe can be corrected with the basic probe calibration method. Measured values and user information are shown on a large, easy-to-read LCD. A display back light ensures easy reading of screen data in poorly-lit conditions. Measuring status indicator showing the measuring status. n. Measuring Principles The gauge adopts two thickness-measuring methods: magnetic induction method and eddy current method. insulating coatings on all non-ferrous metals and on austenitic stainless steels, e.g. paint, anodizing coatings, ceramics, etc. applied on aluminum, copper, zinc die-casting, brass, etc. Working Conditions Working temperature£º -10¡æ¡«£«50¡æ; Storage temperature£º-30¡æ¡«£«60¡æ; Relative humidity: ¡Ü90£¥; The surrounding environment should avoid of vibration, strong magnetic field, corrosive medium and heavy dust. Configuration No. Item Quantity Remarks Standard Config. 1 Main unit 1 2 Probe 1 F1 or N1 3 Calibration Foils 5 PCS 4 Zero plate 1 Iron or Aluminum 5 Instrument case 1 6 Manual 1 7 Alkaline Battery 2 PCS AA size 8 Optional Config. 9 Other type of probes 10 DataPro software 1 On CD 11 USB cable 1 bjxhhd-tech.com sinharef@126.com
With different external probes, the gauge can be applied to measuring thickness of non-magnetic coating on magnetic metal substrate, as well as non-conductive coating on non-magnetic metal substrate. Five types of probes (F400, F1, F10, N1, CN02) are available for different application. F10 probe measures up to 10mm. Two measuring modes: single or continuous, changeable. Two calibration methods can be applied to the gauge; And the system error of the probe can be corrected with the basic probe calibration method. Measured values and user information are shown on a large, easy-to-read LCD. A display back light ensures easy reading of screen data in poorly-lit conditions. Measuring status indicator showing the measuring status. The gauges¡¯ user-friendly measuring system permits automatic storage of up to 1000 readings in one memory matrix for later statistical evaluation. Measuring Principles The gauge adopts two thickness-measuring methods: magnetic induction method and eddy current method. insulating coatings on all non-ferrous metals and on austenitic stainless steels, e.g. paint, anodizing coatings, ceramics, etc. applied on aluminum, copper, zinc die-casting, brass, etc. Working Conditions Working temperature£º -10¡æ¡«£«50¡æ; Storage temperature£º-30¡æ¡«£«60¡æ; Relative humidity: ¡Ü90£¥; The surrounding environment should avoid of vibration, strong magnetic field, corrosive medium and heavy dust. Configuration No. Item Quantity Remarks Standard Config. 1 Main unit 1 2 Probe 1 F1 or N1 3 Calibration Foils 5 PCS 4 Zero plate 1 Iron or Aluminum 5 Instrument case 1 6 Manual 1 7 Alkaline Battery 2 PCS AA size 8 Optional Config. 9 Other type of probes 10 DataPro software 1 On CD 11 USB cable 1
Supported by an industrious team of professionals, we are engaged in manufacturing Vertical Autoclave. The Vertical Autoclave, are manufactured, as per the industrial norms. Known for the high performance, the Vertical Autoclave, provided by us, have great demand across the global market. We provide the Vertical Autoclave in varied technical specifications to meet the diverse needs of the industries. Features ,Vertical - Model ,Useful for sterilization ,Double walled in construction ,Inner made of thick gauges stainless steel with argon welding ,Outer made of thick gauge stainless steel with 3 Nos. metal casting legs ,Foot lifting facility for opening of lid ,Silicon Gasket to minimize the heat loss ,Stainless Steel made wing nuts for tightening of lid ,Selection of Regular, Semi - Automatic & Fully Automatic ,Solid State Digital Temperature Controller with timer
Box dimension - 1000mm x 750mm x 750mm Box Material - Stainless steel 304 L box with mirror finish inside brushed finished outside Acid resistant Box panel/window Openable Front window with polycarbonate an extra coating for chemical and scratch resistance One Feed through electrical single phase 220 V - 16 A Attainable purity < 100ppm H2O and < 500ppm O2 at complete pressure range. O2 = 20 l , H2O = 960 g Filtration HEPA : particles Glove Ports - Glove ports, 220mm diameter and should be O ring sealed Gloves Materials Gloves Piercan USA make Neoprene, or Butyl Dust filter - 0.3 micron Dust filter. HEPA Filter 0.3 micron HEPA, H13 or H14 Gas Purifier - Molecular sieves, Activated Carbon, Charcoal chamber with high efficient O2 ,H2O adsorbent One each Shelves - Height Adjustable, Acrylic Stainless Steel shelves Three/ Yes Box Pressure Control -+15 mbar to -15mbar. Automatic pressure control. Yes Box Lamp -One front mounted fluorescent lamp one inside Yes Antechamber Type Cylindrical, 300 mm diameter, Length 600mm (inside dimensions) Material stainless steel, thickness 2.5mm Inside surface brushed finish Sliding tray stainless steel Doors SS thickness 10mm Door lock easy to operate, spindle lock Pressure gauge, monometer: analog display Vacuum/ Refill process. Regeneration Below 5% loss Complete automated or manual operation with foot switch Yes Sensors Solid state oxygen sensor with 0- 1000 ppm & Solid state moisture sensor with 0-500 ppm Auto purge PLC controlled via system control panel. PLC Program Logi Control with integrated control with external display unit 10 One Yes Vacuum Pump 740 mm HG with fittings (Optional) High Vacuum Pump: Oil sealed vacuum pump â?? 150 lpm,Vacuum level : 5x10ï?Â2mbar Type rotary vane pump, dual stage, Oil mist filter, Oil recirculation, Automatic gas ballast control, 10 m3/h Optional facility for automatically turning off the vacuum pump when the antechamber is not in use One Recirculation Pump Optional Re circulating purified gases pro rata basis 20m3/ per hour Service Support - Efficient service facilities with trained engineers at your place warranty One years comprehensive onsite warranty.
Box dimension 1000mm x 750mm x 750mm Box Material Stainless steel 304 L box with mirror finish inside brushed finished outside Acid resistant Box panel/window Openable Front window with polycarbonate an extra coating for chemical and scratch resistance One Feed through electrical single phase 220 V - 16 A Attainable purity < 100ppm H2O and < 500ppm O2 at complete pressure range. O2 = 20 l , H2O = 960 g Yes Filtration HEPA : particles Yes Glove Ports Glove ports, 220mm diameter and should be O ring sealed Gloves Materials Gloves Piercan USA make Neoprene, or Butyl Dust filter 0.3 micron Dust filter.HEPA Filter 0.3 micron HEPA, H13 or H14 Gas Purifier Molecular sieves, Activated Carbon, Charcoal chamber with high efficient O2 ,H2O adsorbent Shelves Height Adjustable, Acrylic Stainless Steel shelves Box Pressure Control +15 mbar to -15mbar. Automatic pressure control. Box Lamp One front mounted fluorescent lamp one inside Antechamber Type Cylindrical, 300 mm diameter, Length 600mm (inside dimensions) Material stainless steel, thickness 2.5mm Inside surface brushed finish Sliding tray stainless steel Doors SS thickness 10mm Door lock easy to operate, spindle lock Pressure gauge, monometer: analog display Vacuum/ Refill process. Regeneration Below 5% loss Complete automated or manual operation with foot switch Yes Sensors Solid state oxygen sensor with 0- 1000 ppm & Solid state moisture sensor with 0-500 ppm Auto purge PLC controlled via system control panel. Yes One Each PLC Program Logi Control with integrated control with external display unit 10â?? One Yes Vacuum Pump 740 mm HG with fittings (Optional) High Vacuum Pump: Oil sealed vacuum pump â?? 150 lpm,Vacuum level : 5x10 2mbar Type rotary vane pump, dual stage, Oil mist filter, Oil recirculation, Automatic gas ballast control, 10 m3/h Optional facility for automatically turning off the vacuum pump when the antechamber is not in use One 2Recirculation Pump Optional Re circulating purified gases pro rata basis 20m3/ per hour Service Support Efficient service facilities with trained engineers at your place warranty One years comprehensive onsite warranty.
Supplier: NDT equipment, ultrasonic thickness gauge, hardness tester, x-ray detection machine, full-automatic film washing machine, personal dosimeter, magnetic flaw detector
LK ¡§C210A Black -white Densimeter Features: This product uses circuits of high-tech products, working with the advantages of accurate measurement, good stability, convenient operation, etc. Parameter: Density range : 0 = 0.00-5.00 Light hole size : Dia 2mm Reading stability : about 0.02 Uncertainty : 0.00-3.00 0.02D, 3.00-4.00 0.04D, 4.00-5.00 0.08D Display form : 3 digits display Sampling time : 0.8s Working environment : 0 ¡§C 40, relative humidity
Hardness tester LK120 Features: Easy one handed operation Digital Display Compact body for areas of restricted space Slim detector allows measurements to be taken on complex curved surfaces such as welds, moulds etc, as well as conventional flat surfaces Conversion function for different hardness scales Self calibrating Supplied with NAMAS certified test piece Used in any direction Lightweight, portable and easy to carry Using large-screen 128 * 64 dot matrix LCD module, information abundant and intuitive. Can be pre-set limit, hardness, when beyond the scope it automatic alarm, convenience customers batch test. English display: menu type operation, uses simple and convenient. Technical parameter: Measuring scope: HLD (170-960) HLD Measuring direction: support plummet, inclined, level, oblique, pure vertical measured material: Steel ,alloy steel, stainless steel, grey cast iron, ductile iron, zinc alloy, copper alloy ,casting of copper, , Copper alloy (brass, bronze), pure copper, forged steel . Hardness formats: HL,HB, HRB, HRC,HRA,HV,HS Display: high contrast segment code type LCD display Data storage: maximum 500 groups (impact times: 32-1) Paper width: 57.5¡À0.5£©mm Paper coil diameter: 30mm Work voltage: 6V Nimh batteries Work Time: about 150h, With power saving function like auto dormancy, automatic shutdown etc. Measuring direction: 360¡ã operating temperature: -10 ~ +50¡æ Shape dimension:213*80*215mm relative humidity: