WF30-12 Cone-shaped Flow meter Pipe type Specification: Cone-shaped flow meter is a new-style high precision flow sensor who can measure all kinds of media. The cone piece throttle hanging over the pipeline center can baffle the fluid, which forms into differential pressure at the up and downriver of the cone. The p corresponds with the media flux, and there are two pressure ports located at the forth and after of the flow sensor respectively positive pressure port and negative pressure port. 1. Apply to: air, liquid & steam in pipe. 2. Pipe diameter: 15mm~2000mm or more. 3. Pressure grade: pn0.25-42.0 4. Accuracy: +0.5% of measure value 5. Turndown: more than 10:1 6. Repeatability: +0.1% 7. Standard betas: 0.450-0.850 8. Pressure loss: % of differential pressure, varies with beta ratio. 9. Installation: 0-3d upstream, 0-1d downstream.
Power: dc 3.6v +0.6v or - 0.6v Pressure resistance: 1.6 mpa, 15min Pressure loss:
Mini ph meter Model rp01 Measuring range 0.0 - 14.0 ph Resolution 0.1 ph Accuracy 0.1 ph Calibration 2 points Plug fixed electrode Size 150 x 29 x 15 mm 46x43x23cm/100pcs 12kg
Trimmer potentiometer Wh06-2a trimming potentiometer With many terminal styles Electrical characteristics Resistance range: 100 ohm~2m ohm Resistance tolerance: +-20% Contact resistance variatio: crv
Cermet trimmer potentiometer 3386 Range of nominal resisrance: 50 Ohm - 2M Ohm Resistance tolerance: +-10% Terminal resistance: < =1%R or 10 Ohm Contact resistance variation: (CRV) =1G ohm (100vac) Effective Electrical travel: >70% of total michanical travel We also manufacture 3006/3296/3386/3266/3329/ 3362/3269 MOQ 10000 PCS
Detailed Selling Lead Description Series: PT6, PT10, PT15, Rotors: G, L, N, M, K, X, W, Y, Z (details as reference) Value: 100-2M ohm Resistance law: Lin/Log/Alog Tolerance: +-10-20% Life: Standard, normal (200-500 turns); Long usage life (10, 000 turns) Contact resistance variation: f_3% RN Angle of rotation: 235 degrees, 240 degrees, 265+-5 degrees Packing: PT15: 1, 000pcs/packet PT10: 1, 000pcs/packet PT06: 1, 000pcs/packet
1.Outer tank diameter: 420mm(47-1.5m)/ 460mm(58-1.8m)/ 480mm (58-2.0m) 2.Outer tank material: PVDF/colorful plate steel 3.Inner tank diameter: 310mm(47-1.5m)/ 360mm(58-1.8/2.0m) 4.Inner tank material & thickness: stainless steel SUS 304-2B & 0.4mm 5.Support stand: Galvanized steel/Alluminum alloy 6.Insulation: 55mm(47-1.5m)/ 55mm(58-1.8m)/ 60mm (58-2.0m) polyurethane foam 7.Capacity:100L-250L Carton
Thermo-siphon solar water heater The feed water tank can automatically supply the water when you using the system. The cold water can be warm up when it flowing into the copper pipe. This patent broke the tradition of hot water using in the water tank. The volume of hot water is not limit for tank volume, and it founded the new times of hot water. Carton
Pedometer 1. 5 lcd manifestation 2. Count can from 0-99999 3. Account the step automatically 4. Press the button to reset once 54x34x35cm
Name: type lxhg-15 volumetric water meter fof cold water Category: plastic shell water meter-> Model number: lxhg-15 Specification: 15mm Carton box
Fan-wheel liquid-sealed anti-reverse water meter Name: fan-wheel liquid-sealed anti-reverse water meter for cold water Category: plastic shell water meter-> Model number: lxsy-15/z-20/z Specification: 15-20 Content: meter design 1. High quality materials(frpa), corrosion resistance. 2. The measuring mechanism can be exchanged. Special features 1. Overload flowrate:qs=2qp(qn=nominal flowrate) 2. Digital-wheel and register are sealed with special with special liquid 3. Clearly reading for a long time 4. Steady and reliable performance 5. Measuring accuracy is up to iso 4064b 6. Anti-reverse water meter, it can be calculated normally when installation is reverse direction of flow. Working condition Water temperaturef_300c Working pressuref_1mpa Feature curve diagram: Reading error:between qs. Flowrate and qt flowrate Max.Reading errorf+2% Between qt flowrate(not including qt):max.Reading errorf+5% Anti-reverse, it can be read nomally and the reading error qp is positive value when meter installed reversedly. Carton box
Application Measuring the volume of cold potable water passing through the pipeline. Features A cubage meter, to calculate the amount of the passing water by the rotating of the piston. The metric device can turn round by 360. Easy to read. This meter has two types:stainless steel and plastic Application Measuring the volume of cold potable water passing through the pipeline. Features A cubage meter, to calculate the amount of the passing water by the rotating of the piston. The metric device can turn round by 360. Easy to read. This meter has two types:stainless steel and plastic
Application Measuring the volume of cold potable water passing through the pipeline. Features Removable element for facilitating installation and maintenance, copper sealed register, long term clear reading, inter-exchangeable parts, magnetic transmission, low driving resistance. Reliable sensitive action, small pressure loss, long working life. Application Measuring the volume of cold potable water passing through the pipeline. Features Removable element for facilitating installation and maintenance, copper sealed register, long term clear reading, inter-exchangeable parts, magnetic transmission, low driving resistance. Reliable sensitive action, small pressure loss, long working life.
Application Measuring the volume of cold potable water passing through the pipeline. Features A)integer vane wheel and magnetic drive, scientifically designed and carefully well manufactured B)numerical wheel register and pointer indication C)magnetic drive, dry dial D)easy long term clear reading E)long work life F)low pressure loss G)the most popular water meter type in the world H)technical data conforms to class b of the iso4064 standard Maximum permissive error A)in the lower zone from qmin inclusive up to but excluding qt is f+5%. B)in the upper zone from qt inclusive up to and including qs is f+2%. Iso4064 b class
Application Measuring the volume of cold potable water passing through the pipeline. Features 1)Integer vane wheel which is scientifically designed and carefully-well manufactured 2)8 digital pointer-roller indicator, low pressure loss 3)low starting flow rate, high sensitive 4)selected high quality materials steady & reliable characteristic easy and clear reading 5)technical data conforms to iso4064 standards b Class Maximum permissive error A)in the lower zone from qmin inclusive up to but excluding qt is f+5%. B)in the upper zone from qt inclusive up to and including qs is f+2% Iso 4064
Application Measuring the volume of cold potable water passing through the pipeline. Features 1.Gathering advantage of the dry type water meter and wet type water meter 2.Liquid sealed register 3.Low starting flow rate, high sensitive 4.Long-term clear reading 5.Steady mechanic drive 6.Technical data conforms to iso4064 standards Iso4064 b class
Water meter Cold and hot water meter. It varies.
Digital panel meters Features: Crisp, bright, flicker-free led display Pre-calibrated meters Latest lsi ic technology Auto polarity and auto zero Compact design Robust terminals Solid-state circuitry Prompt service support International styling Parameters: Ac volt Dc volt Ac current Dc current Specifications: Aux supply : nominal 240 v ac (170-270 v ac) Accuracy : class 1 [+/- (1% of full scale + 1count)] For hz. Meter: 0.1/0.01 hz. Resolution : 1 count in 100 counts or better Display : 3 + / 3 digits Burden : 0.2 va max. 3 va max. On auxiliary supply Ambient : 0-50 ª c humidity < 95% Weight : 320-700gms depending on model Dimension(mm) : 48x96, 96x96, 72x72 Mounting : panel mount Dimension(mm) : 48x96, 96x96, 72x72 Mounting : panel mount
Itemno. Bz142-1 Supply voltage ac24v/240v, 50/60hz Dimensions 48f-48f-40mm Time range 0f+99, 999.99 hours Installation mode inbuilt Net weight 50g
Dry type vane wheel water meter Working condition: Water temperature: 30 for cold potable water meter 90 for hot water meter Water pressure: 1mpa