Itemno. Bz142-1
Supply voltage ac24v/240v, 50/60hz
Dimensions 48f-48f-40mm
Time range 0f+99, 999.99 hours
Installation mode inbuilt
Net weight 50g
Supplier: Hour meters
Use ultrasonic flow measurement technology, no mechanical moving parts drift diameter design, no pressure loss, cut down the electric consumption of the pump and help untilities reduce cost. Features: Low in initial flowrate, and the min. Flow velocity measured is0.002 m/s; Measurement cycle 1 time per second, battery powered (One battery can work continuously for 6 years); Multi-channel construction design, double cross section measurement, and be able to ensure the measurement accuracy to the largest extent; Be able to work at any flow point for long time; IP68 of the whole meter, for each unit of the meter is IP68 designed; Micro-consumption design, less than 0.0008W; Drift diameter design, no pressure loss. Operating on velocity-difference principle, the LG-UWM68 series is specially designed for urban water supply and building-use. The conventional water meters suffer from the drawbacks that they are only operable at a higher flowrate and are insensitive to a small flowrate. However, the LG-UWM68 series water meter can help tackle the bottleneck. And the meter is highly adaptable to diversified industrial conditions Due to the use of ultrasonic flow measurement technology, it has no mechanical moving parts drift diameter design, no pressure loss, cut down the electric consumption of the pump and help the enterprises reduce cost Be able to work at any flow point for a long time and high in reliability, immune to magnetic interference Battery-powered capable of operating continuously for a period of over 6 years with a single cell High sensitive to minimal flowrate and high in measuring accuracy Capable of performing various output function, and it is capable of making wireless transmission of meter reading to form a monitoring system via the GSM network to monitoring the meter's running status and the pipe network conditions. Three design versions are available, i. e. The ordinary version, 2-way version and fire water version are cater to different needs of users Ordinary version: Measurements of the flowrate and cumulative running time in positive direction 2-way version: Capable of measuring flowrate, cumulative flowrate cumulative running time in positive/reverse direction; Fire water version: Much bigger range ratio, and specially designed for fire water. CE: 2004/108/EC The meter is in conformity with Standard on Measurement of Water Flow in Fully Charged Closed Conduits_Meters for Cold Potable Water and Hot Water GB/T 778-2007-a standard is issued by the People's Republic of China L Ex-factory calibration of the meter is made in conformity with Standard on Water Meter for Potable Cold Meter JJG162-2009- a standard is issued by the People's Republic of China.
Available in sizes from dn 10 to 300 mm (1/2"÷12"); Flanged connection (wafer-type connection for Dn10, 15 mm); Bidirectional flow measurement (on request); Full-bore meter design eliminates pressure loss in measurement section; No filtering required; Short straight pipe runs required for installation; Protection against unauthorized access; Suitable for mounting on polymer pipes; Oiml and ISO 9001:2008 certified.
Introduction: Equipped with our companyí»s code controller, base meters are bought abroad to realize the prepaid and control functions, thus to achieve the automatic control of different functions of this new type of gas meter. Range of application: This product can be applied to the measurement of gas, natural gas, liquefied petroleum gas and other non-corrosive gases in the city. Main features: Automatic prepaid function: charging before using of it, water meter residual capacity= the original gas + newly purchased gas Auto-control function: switching the gas path automatically according to the payments and gas situation. Real time computation function: measuring on the real time and display the stock value, closing gas source automatically when the purchased gas is used up. Power-down memory function: solid state recorder is internally installed and the data will be permanently preserved. Status display function: displaying the amount of newly charged gas, the remaining stock and cumulative use, as well as low-voltage state etc. Prompting function: warning when the remaining gas is used to the set value or other functions are out of work. Overdrawing function: able to set a certain overdraft gas according to the user needs Automatic alarm function: when the voltage is lower than certain point, alarm system will be operated and the battery must be replaced within 72 hours, otherwise, it will automatically shut down the gas resources. Anti-gas-larceny function: shut down the gas supply automatically when there are theft of gas or illegal operations Technical parameter: 1ú¬base meter operation criteriaú¦gb/t6869 q/ofd.001-2007 jjg577-2005 2) current working voltageú¦3.00v 3ú¬cuiescent currentú¦=8 years 5ú¬life span of valveú¦switching frequency more than 5000 times 6ú¬accuracy degreeú¦level b 7ú¬four anti-functionú¦anti-attack, waterproof, anti-smoke, anti-knocking
Low maintenance cost and easy installation Long lasting performance: No maintenance and repair for 6 years â?¢ Intelligent information can be output by providing advanced statistical data and diagnostic programs â?¢ Maximum tolerance of Class 1 meter: 1% in convection area ( Q2 â?¤ Q â?¤ Q4) 3 % in small area (Q1 â?¤ Q â?¤ Q2) [ SPECIFICATIONS ] * Measuring caliber 25 mm ~ 1,200 mm * Domestic Approval : 50 mm, 65 mm, 80 mm, 100 mm, 125 mm, 150 mm, 200 mm, 250 mm, 300 mm, 350 mm * Composition : Detection unit: Electronic sensor / Conversion unit: input unit, operation unit, output unit, indicator * Accuracy Full Scale: 0.2% (65 mm ~ 250 mm: 1st grade / 50 mm, 300 mm, 350 mm: 2nd grade) * Max. Measureable Flow Rate : 10 m/s * Display unit and contents : Accumulated flow (m3): 9 digit x 1 (forward, reverse, modification available) Instantaneous flow rate (m3 / h): 4 digits, date, time, alarm (battery life and empty pipe) and data logger * Measurement function : Low flow cut off: 0 ~ 9 of maximum flow * Measurement frequency : Battery Type : 1/5 Hz / AC Type : 6.25 Hz * Max working pressure : 1.0 MPa ~ 1.6 MPa * Input : 4 ~ 20 mA pressure gauge signal (Loop Powered Terminal): AC Type * Output : 1 Instantaneous flow rate (4 to 20 mA) 1 - AC Type 2 accumulated flow (O.C Pulse) - Pulse Load 5 ~ 35 V DC / 50 mA (Common for AC & Battery Type) * Liner : Hard Rubber * Electrode Hastelloy C * Housing/Flange : Carbon Steel * Communication and internal memory : RS 485 MODBUS: AC Type / Internal memory: Date, time, instantaneous flow rate, accumulated flow rate, and pressure Memory interval: 5 seconds ~ 24 hours (1 year storage upon 1 minute interval storage) * Power Battery Type : 3.6 V DC (Life span 7 years) / AC Type : 110 ~ 220 V AC * Temperature : Ambient temperature: 20 ~ 60 / Storage temperature: 30 ~ 70 (humidity up to 95%) * Protection class : Detection unit (IP 68) / Converter (IP 65) [ APPLICATIONS ] Water industry / Wastewater treatment industry For more details on quality Korean flowmeters, please feel free to visit http://www.hnl-global.com/flowmeter and contact us.
[ CHARACTERISTICS ] Low maintenance cost and easy installation Long lasting performance: No maintenance and repair for 6 years Intelligent information can be output by providing advanced statistical data and diagnostic programs Maximum tolerance of Class 1 meter: 1% in convection area ( Q2 â?¤ Q â?¤ Q4) 3 % in small area (Q1 â?¤ Q â?¤ Q2) [ SPECIFICATIONS ] * Measuring caliber 25 mm ~ 1,200 mm * Domestic Approval : 50 mm, 65 mm, 80 mm, 100 mm, 125 mm, 150 mm, 200 mm, 250 mm, 300 mm, 350 mm * Composition : Detection unit: Electronic sensor / Conversion unit: input unit, operation unit, output unit, indicator * Accuracy Full Scale: 0.2% (65 mm ~ 250 mm: 1st grade / 50 mm, 300 mm, 350 mm: 2nd grade) * Max. Measureable Flow Rate : 10 m/s * Display unit and contents : Accumulated flow (m3): 9 digit x 1 (forward, reverse, modification available) Instantaneous flow rate (m3 / h): 4 digits, date, time, alarm (battery life and empty pipe) and data logger * Measurement function : Low flow cut off: 0 ~ 9 of maximum flow * Measurement frequency : Battery Type : 1/5 Hz / AC Type : 6.25 Hz * Max working pressure : 1.0 MPa ~ 1.6 MPa * Input : 4 ~ 20 mA pressure gauge signal (Loop Powered Terminal): AC Type * Output : 1 Instantaneous flow rate (4 to 20 mA) 1 - AC Type 2 accumulated flow (O.C Pulse) - Pulse Load 5 ~ 35 V DC / 50 mA (Common for AC & Battery Type) * Liner : Hard Rubber * Electrode Hastelloy C * Housing/Flange : Carbon Steel * Communication and internal memory : RS 485 MODBUS: AC Type / Internal memory: Date, time, instantaneous flow rate, accumulated flow rate, and pressure Memory interval: 5 seconds ~ 24 hours (1 year storage upon 1 minute interval storage) * Power Battery Type : 3.6 V DC (Life span 7 years) / AC Type : 110 ~ 220 V AC * Temperature : Ambient temperature: 20 ~ 60 / Storage temperature: 30 ~ 70 (humidity up to 95%) * Protection class : Detection unit (IP 68) / Converter (IP 65) [ APPLICATIONS ] Water industry / Wastewater treatment industry
SYSTEM INFORMATION The electromagnetic flow meter HMF 2110 series is the most common and highly accurate flow measurement device that can be universally used in various measurement fields. Since there is no driving part like a propeller, no trouble is caused due to pressure loss, and the durability is excellent In addition, since the installation is simple with the flange type, even a beginner can easily install it through simple training. The sensor measures the flow rate by direct contact with the fluid,, thus a more reliable flow rate value can be obtained, and the reproducibility is also excellent If you are looking for a flowmeter that can be used with confidence, choose the HMF 2110 series without hesitation. â?? KEY FEATURES Quick Start Self diagnostic Easy Maintenance â?? CHARACTERISTICS â?¢ Due to high stability, popular for water flow measurement â?¢ Excellent durability due to no driving part â?¢ Electrode and lining materials are selected for measuring chemical flow â?¢ There is no pressure drop, which reduces electricity costs. â?? SPECIFICATIONS * Sensor installation method : Flange mounting type (Standard: JIS, DIN, ANSI, etc.) * Accuracy : �±0.2% (flow rate 0.1 m/s or more)0.2% (flow rate 0.1 m/s or more) * Max Minimum Flow : 0.05 m/s ~ 10 m/s (Flow rate by diameter) * Measuring pipe caliber : 6 mm ~ 2,000 mm * Measurable fluid : Water, sewage, wastewater, chemicals, etc. (Conductivity of 5�¼S /cm or more) * Power : 110 ~ 220 V AC / 60 Hz * Operating temperature : Sensor (40 ~ 70 â??), Operation: (18 ~ 60 â??) * Screen display contents : LCD Size: LCD Display 100 x 55, 3 Line, 16 Characters, Instantaneous flow rate (4 digit), accumulated flow rate (9 digit), pressure (4 digit) * Flow display unit : Unit: m3, L, etc. / Directions: Forward & Reverse (-) * Electrode : Hastelloy C * Liner: NBR, Hard Rubber, EPDM * Flange : Carbon Steel * Flow measurement frequency : 1.875 ~ 12.5 Hz * Sensor cable length : 100m * Output signal : 4 ~ 20 mA, Integrated pulse active , Passive (Max 10 kHz), Relay pulse (Max Load 24 V DC / 1A) * Communication and memory : RS 232, RS 485 Modbus 128 Mbyte internal memory: date, time, instantaneous flow rate, accumulated flow rate, Pressure memory interval: 5 seconds ~ 24 hours * Protection class : Sensor unit: IP 68 / Operation unit: IP 65 * Self diagnosis function : Alarm display when empty pipe information and self diagnosis error occur For more details on quality Korean flowmeters, please feel free to visit http://www.hnl-global.com/flowmeter and contact us.
System Information The electromagnetic flow meter HMF 2110 series is the most common and highly accurate flow measurement device that can be universally used in various measurement fields. Since there is no driving part like a propeller, no trouble is caused due to pressure loss, and the durability is excellent In addition, since the installation is simple with the flange type, even a beginner can easily install it through simple training. The sensor measures the flow rate by direct contact with the fluid,, thus a more reliable flow rate value can be obtained, and the reproducibility is also excellent If you are looking for a flowmeter that can be used with confidence, choose the HMF 2110 series without hesitation. â?? KEY FEATURES Quick Start Self diagnostic Easy Maintenance â?? CHARACTERISTICS â?¢ Due to high stability, popular for water flow measurement â?¢ Excellent durability due to no driving part â?¢ Electrode and lining materials are selected for measuring chemical flow â?¢ There is no pressure drop, which reduces electricity costs. â?? SPECIFICATIONS * Sensor installation method : Flange mounting type (Standard: JIS, DIN, ANSI, etc.) * Accuracy : �±0.2% (flow rate 0.1 m/s or more)0.2% (flow rate 0.1 m/s or more) * Max Minimum Flow : 0.05 m/s ~ 10 m/s (Flow rate by diameter) * Measuring pipe caliber : 6 mm ~ 2,000 mm * Measurable fluid : Water, sewage, wastewater, chemicals, etc. (Conductivity of 5�¼S /cm or more) * Power : 110 ~ 220 V AC / 60 Hz * Operating temperature : Sensor (40 ~ 70 â??), Operation: (18 ~ 60 â??) * Screen display contents : LCD Size: LCD Display 100 x 55, 3 Line, 16 Characters, Instantaneous flow rate (4 digit), accumulated flow rate (9 digit), pressure (4 digit) * Flow display unit : Unit: m3, L, etc. / Directions: Forward & Reverse (-) * Electrode : Hastelloy C * Liner: NBR, Hard Rubber, EPDM * Flange : Carbon Steel * Flow measurement frequency : 1.875 ~ 12.5 Hz * Sensor cable length : 100m * Output signal : 4 ~ 20 mA, Integrated pulse active , Passive (Max 10 kHz), Relay pulse (Max Load 24 V DC / 1A) * Communication and memory : RS 232, RS 485 Modbus 128 Mbyte internal memory: date, time, instantaneous flow rate, accumulated flow rate, Pressure memory interval: 5 seconds ~ 24 hours * Protection class : Sensor unit: IP 68 / Operation unit: IP 65 * Self diagnosis function : Alarm display when empty pipe information and self diagnosis error occur For more details on quality Korean flowmeters, please feel free to visit http://www.hnl-global.com/flowmeter and contact us.
Supplier: Digital/ analog volt amp hour timer meter (electrical panel meter )