Pheht combination ph, redox & temperature sensor description The ph/orp cartridge is designed to last for an extended time with plastogel technology meaning recalibration and replacement is infrequent. The sensor has been designed for the most difficult situations for a ph/orp sensor in terms of sensor resistance, quick response time, minimal flow dependence and low power consumption. Digitally optimised measurement technology * combination ph, redox & temperature sensor * smart sensor stores configuration settings and calibration history * digital sensor: modbus rs-485 * field replaceable ph/orp sensor cartridge * robust and watertight Pheht combination ph, redox & temperature sensor range * ph: 0 to 14 * redox: -1000mv to +1000mv * temperature: -10'c to +50'c Pheht combination ph, redox & temperature sensor applications The pheht sensor has been designed to perform under hard conditions, from pure mountains water with conductivity as low as 20 us/cm, lakes and rivers (100 - 2000 us/cm), seawater with conductivities of 50 ms/cm, to waste water with conductivity higher than 200 ms/cm. Pheht combination ph, redox & temperature sensor specifications * phâ?? range: 0 - 14 * phâ?? resolution: 0, 01 * phâ?? accuracy: +/- 0.1â?? * redox range: -1000 to +1000 mv * redox resolution: 0.1 mv * redox accuracy: â± 2 mv * temperature range 0, 00 'c to + 50, 00'c * temperature resolution 0, 01 'c * temperature accuracy â± 0, 5 'c
HG-P40C Ultrasonic Proximity Sensor & Module Description * Using only a single transceiver sensor unit for transmit and receive signals. * Convenient for distance measuring and object detection. * Two types of transmit mode for convenience. - Free Run : With a power supply, sensor transmits trigger and burst signal itself - for basic application - External Trigger : External system(controller or processor circuit) controls the trigger signals - for advance application(distance measure) * Two types of input power - Low(5V) for processor circuit usage and High(12V) for controllers. * Four different output signal (simultaneously). - Real time ultrasonic wave amplified from actually received ultrasonic. (for sound pressure measuring) - Real time TTL level square signal(Square Wave) of detection signal. (for robots) - Distance pulse width signal which is proportional to the nearest object from the sensor. (for robots and distance measuring) - Proximity output signal(10mA current) within the preset range(0.5~4.5m) (for industrial use) - Preset range is adjustable from 0.5 to 4.5 m. (factory distance preset available for volume orders) * High performance ASIC Chip for stable transmission and sensitive reception. (Max. approx. 4,000 times amplification) HG-P40C Ultrasonic Proximity Sensor & Module Features * Multi functional transceiver model * Two types of transmit modes (Free Run / External Trigger) * Power Supply (Low : 5V / High : 6~16V) * 4 different output signals (simultaneously) - Real time received and amplified ultrasonic wave - Real time TTL square signal - Distance pulse width signal - Detecting objects within the preset range(proximity) * High performance ASIC Chip HG-P40C Ultrasonic Proximity Sensor & Module Specification * Input DC: Low : 5V / High : 6~16V * Current consumption (when 12V is used) - 12mA (Standby Mode) - 18mA (When an object is detected within the range) - 28mA (Proximity signal 10mA deducted) * Distance Range (at flat plate) - 0.4~3m (when 5V is used) - 0.4~6m (when 12V±3V is used) * Size Module : 20x36x20(mm) Sensor : Φ16
Product Application Water supply engineering, sewage treatment engineering and other flow monitoring. Technical Parameter Tube Diameter: from 300 to 3000mm Velocity Range: from 0.1 to 10m/s Accuracy: 0.5 ~ 10m/s, + 1.5%FS, 0.1 to 0.5m/s, and + 2.0%FS 0.1 ~ 10m/s, + 2.54%FS Electrical conductivity: > 5 mu s/cm Straight Tube Upstream 5DN, Townstream 3DN Medium temperature: -20 C ~ +130 C Ambient temperature: -20 C ~ +60 C The pressure: â?¤1.6MPa Protection grade: IP65 (intagratation), IP68 (divided) Electrode Material: 316L stainless steel Output signal: 4-20mA; RS485; HART protocol; MODBUS protocol Sensor material: stainless steel Working Power: 220VAC; tolerances of 15% or 24VDC, the rippleâ?¤ 5% Power: 6.5W
Static Strain Amplifier Model: CJ2533 Discription CJ2533 adopts intelligent management and high quality components, toggle switch replaced by electronic switch, greatly improved the stability and reliability of the test. It can be widely used in teaching test field and small engineering testing. Features 4,8,16,24channels (random combine )strain test point and 1 channel force test point; 4 ½ digits LED display test value; Synchronized dual-window display; Test point and Bridge circuit Indication; All parameters can be set and stored; To provide fully functional application software; Suitable For teaching and engineering testing; Small Size, easy to handle. Model: CJ2533 Input Range 0 - ±19999 µ(2VDC) Channal 4 8 16 32 64 Gage Resistance 60 ?? 1000 ?¦ Resolution 1 µ Zero Stability ?¤1 µ/ ?? ; ?¤3 µ/4h Sensitivity Stability ±0.02 FS/ ??; ±0.1 FS+1 µ)/2h Bridge Voltage 2VDC Bridge Voltage 1,1/2,1/4, Common compensation Accuracy ±0.2FS±2 µ Output Analogy BNC 4 ½ LED Display Sensitivity coefficient 1.00 - 9,99 Nonlinearity ±0.05% Balance Range 0 - ±19999µ Scan Speed 6 channels / s Operating Temperature 0 ??- +40 ?? Humidity 95%R.H. Power Supply AC220V50Hz; DC+9 - +15V AC220V50Hz Dimensions (mm) 360D 84H 3200W Weight 3.5Kg Input/Ouput Input: Terminal strip; Output:RS-232C interface
Introduction CJW01 Turbine Flow Meter is a new generation of turbine flow meter, which absorbs the advanced technology of flow meters at home and at abroad, and has the characteristics of simple structure, light weight, high accuracy, good reproducibility, sensitive response, easy installation and maintenance. It is matched with the display instrument with special functions.It can also carry out quantitative control, excessive alarm and so on. It is an ideal instrument for flow measurement and energy saving. Features Simple Structure Light weight High accuracy Good reproducibility Sensitive response Easy installation and maintenance Technical Parameter Standard turbine flowmeter (JB/T9246-1999) Instrument caliber& connection methods: 4, 6, 10, 15, 20, 25, 32, 40 with threaded connections; 15, 20, 25, 32, 40) 50, 65, 80, 100, 125, 150, 200, flanged connections Precision grade: + 1%R, + 0.5%R, + 0.2%R (customize) Meassure Range: 1:10, 1:15, The instrument body material: 304 stainless steel or aluminum Impeller: anticorrosion ABS or high quality aluminum alloy Converter: cast aluminum Usage Condition: medium temperature: -20 C ~ +80 C environment temperature: -30 C ~ +60 C Relative humidity: 5% ~ 90% Atmospheric Pressure: 86KPa ~ 106Kpa Working Power Supply: A: power supply: +24VDC + 15%, rippleâ?¤5%, suitable for 4 ~ 20mA, pulse output, RS485 etc. B: 1 group 3.0V010AH lithium battery, the battery voltage can work normally from 2 to 3.0V Overall power consumption A: external power: < 1W B: Internal power supply: average power consumptionâ?¤1W, more than three years of continuous use Analog output: pulse signal, 4 ~ 20mA current signal, control signal Communication output: RS485 Real time record, Start and stop record, diary, fixed time interval record Internal thread: M20*1.5 of or user self determination Explosion-proof grade: ExdIIBT6 or ExiaIICT4 Protection grade: IP65 Product Application Widely used for measuring the closed pipes and stainless steel 1Crl8Ni9Ti, 2Cr13 and AI203, corundum hard alloy do not corrode, and no fiber, particles and other impurities. When working temperature, kinematic viscosity should be less than 5 * 10-6m2/s liquid. When kinematic viscosity greater than 5 x 10-6m2/s liquid, can label flow meter actually before use
Economic and reasonable OEM humidity sensor module Humidity voltage output: 1-3.6V Low power consumption Long stability and proven reliability not affected by repetitive condensations Direct interface with micro-controller RoHS Directive-compliant
Economic and reasonable sensor of high accuracy and quality Compact size and slim design Compatible plug-in module design Various combinations of temperature and humidity outputs including passive
MEMS technology-based ultra-precise digital sensors Excellent long-term stability and self digital correction RS485 communication Free monitoring S/W for PC Slim size with large display Excellent long-term stability and self-digital correction
3-way measurement particles, temperature and humidity Reliable and precisely measured data Multiple point data measurement and monitoring Wired/wireless communication of measured data
1?numeral and lcd display 2 ?lcd display shows the distance to 0.01m 3?step-up buzzer alarm 4?numeral display from 1.80m to 0.30m. 5?2, 4, 6, 8 sensors for option 6?yellow, blue color background light in display for option
1?numeral and color led display 2?slim dash mounted display 3? step-up buzzer alarm 4?left and right obstacle indication 5?numeral display from 1.8m to 0.3m 6?display unit with built-in buzzer 7?2, 3, 4 sensors for option Contact me to get product pictures.
1)numeral and lcd display 2 )lcd display shows the distance to 0.01m 3)step-up buzzer alarm 4)numeral display from 1.80m to 0.30m. 5)2, 4, 6, 8 sensors for option 6)yellow, blue color background light in display for option Contact abby to get product pitures.
1.Image sensor:1/4 inch color cmos 2.Total pixels:656*492 3.Resolution:420tv lines 4.Lens angle:170degree 5.Mini lumination:0.0 lux 6.Power supply:dc 12v Contact abby to get more product information.
1?no display 2?step-up buzzer alarm 3?buzzer alarm switch:off, lo, hi 4?detective distance from 1.8m to 0.3m 5 ?2, 3, 4, 6, 8, sensors for option Contact abby to get product pictures .
1?numeral and color led display 2?ultra slim dash mounted led display 3? step-up buzzer alarm 4?left and right obstacle indication. 5?numeral display from 1.8m to 0.3m 6?display unit with built-in buzzer 7?2, 3, 4 sensors for option Contact me to get product pictures .
Manufacturer:panasonic Product category:board mount motion & position sensors Rohs:rohs compliant compliant Product:motion sensor Sensing distance:5 m Output type:digital Operating supply current:170 ua Package / case:to-5 Maximum operating temperature:+ 60 c Packaging:bulk Supply voltage - max:6 v Supply voltage - min:3 v Brand:panasonic industrial devices Features:white lens Minimum operating temperature:- 20 c Series:ekmc Tradename:papirss
Manufacturer:panasonic Product category:board mount motion & position sensors Rohs:rohs compliant Product:motion sensor Sensing distance:12 m Output type:digital Operating supply current:170 ua Package / case:to-5 Maximum operating temperature:+ 60 c Packaging:bulk Supply voltage - max:6 v Supply voltage - min:3 v Brand:panasonic industrial devices Features:enclosed sensing circuits, high s/n ratio Minimum operating temperature:- 20 c Series:ekmc Factory pack quantity:50 Tradename:papirss
Linear systems is a major burner controller manufacturers, providers and exporters. We are offering our products in a comprehensive range of requirements to get to know the various requirements of the industry.
Manufacturer:Panasonic Product category:Board mount motion & position sensors Rohs:Rohs compliant details Product:Motion sensor Sensing distance:5 m Output type:Digital Operating supply current:170 ua Package / case:To-5 Maximum operating temperature:+ 60 c Minimum operating temperature:- 20 c Supply voltage - max:6 v Supply voltage - min:3 v Brand:Panasonic industrial devices Features:Black lens Packaging:Bulk Series:Ekmc Factory pack quantity:50 Tradename:Papirss
Performance Sensitivity na/ppm at 2ppm co 420 to 650 Response time t90 (s) from zero to 10ppm co < 25 Zero current na in zero air at 20°c +30 to -130 Noise* ±2 standard deviations (ppb equivalent) 4 Range ppm limit of performance warranty 1000 Linearity ppb co error at full scale, linear at zero, 500ppm co 20 to 35 Overgas limit maximum ppm for stable response to gas pulse 2000 * tested with alphasense isb low noise circuit Environmental Sensitivity @ -20°c (% output @ -20°c/output @ 20°c) @ 5ppm co 40 to 70 Sensitivity @ 50°c (% output @ 50°c/output @ 20°c) @ 5ppm co 110 to 125 Zero @ -20°c na -30 to +30 Zero @ 50°c na -50 to -200 Cross sensitivity Filter capacity ppm·hrs h2s 250, 000 H2s sensitivity % measured gas @ 5ppm h2s < 1 No2 sensitivity % measured gas @ 5ppm no2 < 1 Cl2 sensitivity % measured gas @ 5ppm cl2 < 1 No sensitivity % measured gas @ 5ppm no < -3 So2 sensitivity % measured gas @ 5ppm so2 < 0.1 H2 sensitivity % measured gas @ 100ppm h2 at 20oc < 10 C2h4 sensitivity % measured gas @ 100ppm c2h4 < 1 Nh3 sensitivity % measured gas @ 20ppm nh3 < 0.1 Key temperature range °c -30 to 50 Specifications Pressure range kpa 80 to 120 Humidity range % rh continuous 15 to 90 Storage period months @ 3 to 20°c (stored in sealed pot) 6 Load resistor o (isb circuit is recommended) 33 to 100 Weight g < 13 Isweek provide smoke, gas, humidity&temperature, uv, fluid or other kinds of sensors More details welcome to inquiry: skype:isweek_laura