Water supply engineering, sewage treatment engineering and other flow monitoring.
Technical Parameter
Tube Diameter: from 300 to 3000mm
Velocity Range: from 0.1 to 10m/s
Accuracy: 0.5 ~ 10m/s, + 1.5%FS, 0.1 to 0.5m/s, and + 2.0%FS 0.1 ~ 10m/s, +
2.54%FS
Electrical conductivity: > 5 mu s/cm
Straight Tube Upstream 5DN, Townstream 3DN
Medium temperature: -20 C ~ +130 C
Ambient temperature: -20 C ~ +60 C
The pressure: â?¤1.6MPa
Protection grade: IP65 (intagratation), IP68 (divided)
Electrode Material: 316L stainless steel
Output signal: 4-20mA; RS485; HART protocol; MODBUS protocol
Sensor material: stainless steel
Working Power: 220VAC; tolerances of 15% or 24VDC, the rippleâ?¤ 5%
Power: 6.5W
Supplier: Water Flow Indicators, Flow Indicators, Electromagnetic Flow Meters, Turbine Flow Meters, Vortex Flow Meters, Flow Mirrors, Valves, Electric Valves And Pneumatic Valves.
Supplier: Electromagnetic flowmeter, vortex flow meter, pneumatic globe control valve, pressure transmitter, level transmitter
Supplier: Electromagnetic flow meter, turbine flow meter, float and board level indicator, tubular level gauge or tubular level indicator, side mounted magnetic level switch, full view sight glass, and double window type sight glass.
Supplier: Flow measuring instruments (electromagnetic flow meter, turbine flow meter, vortex, water meter, diesel flow meter, rotameter) level measuring instruments (tubular level indicator, reflex level indicator, transparent level indicator, float & board level indicator, magnetic level indicator, oil level indicator) level switches, sight flow indicators, strainers, temperature gauges, pressure gauges, tanks & column
Buyer: Ss304, ss202, ss316 (flanges, pipe, hex, circle, rod, fastener, mesh), mild steel pipe, circle, rod, etc. toughened glass, borosilicate glass, EPDM gasket, PTFE gasket, etc.
MODEL CG 06 Nominal Diameter : 6mm,flow rate 18 kg/min,Temp:-200 to +200 degree C,accuracy .1%,Warranty 1 year,weight 8.6 KG,316L SS,Flanged End connection, CE, ATEX Certified, ISO Certified,Out Put 4-20Ma, with HART , Pulse, Type: Coriolis Mass flowmeter MODEL CG 15 Nominal Diameter : 15mm,flow rate 50 kg/min,Temp:-200 to +200 degree C,accuracy .1%,Warranty 1 year,weight 12 KG,316L SS,Flanged End connection, CE, ATEX Certified, ISO Certified,Out Put 4-20Ma, with HART , Pulse, RS 485. Type: Coriolis Mass flowmeter MODEL CG 25 Nominal Diameter : 25mm,flow rate 200kg/min,Temp:-200 to +200 degree C,accuracy .1%,Warranty 1 year,weight 23 KG,316L SS,Flanged End connection, CE, ATEX Certified, ISO Certified,Out Put 4-20Ma, with HART , Pulse Type Coriolis Mass flowmeter MODEL CG 50 Nominal Diameter : 50mm,flow rate 1000kg/min,Temp:-200 to +200 degree C,accuracy .1%,Warranty 1 year,weight 75 KG,316L SS,Flanged End connection, CE, ATEX Certified, ISO Certified,Out Put 4-20Ma, with HART , Pulse Type: Coriolis Mass flowmeter MODEL CG 80 Nominal Diameter : 80mm,flow rate 3000kg/min,Temp:-200 to +200 degree C,accuracy .1%,Warranty 1 year,weight 134 KG,316L SS,Flanged End connection, CE, ATEX Certified, ISO Certified,Out Put 4-20Ma, with HART , Pulse. Type: Coriolis Mass flowmeter
food grade flow meter,1000bar food grade flow meter. Now, the market of food grade flow meter is very hot. there exists about 80 factories located in the suburb of Dongtai city in Zhejiang province, the cluster of this industry. But the market there is also filled with chaos. Many companies live on purchasing components to reassemble; some company may think it too troublesome and the work as briefcase company to declare that they are manufactures of food grade flow meter. This situation is worring. The so-called manufactures do not have their own calibrator at all, leave alone the accuracy of food grade flow meter. Facing this complicated situation, the chief engineer, Mr. Tu Jianwen, who worked as a senior engineer in Siemens in Germany, came to Shanghai from his hometown Cixi in 2008. He was determined to create the world-class food grade flow meter and established Shanghai Cixi Instrument Co. Ltd by the name of his hometown. The food grade flow meter were produced and developed by the technology of Siemens numerical control system. Once upon a time, China, the world’s factory, is always the synonym with the “low quality”. Especially, the food grade flow meter, which are used to control in automatic process are produced cumbersome and noisy and can not measure the sticky medium. Thus, whether the quality is stable has become users’ greatest concern. So, sometimes buying food grade flow meter is like buying a lottery ticket. What’s more, the quality is left to chance and can not be guaranteed. That Shanghai Cixi Instrument Co. Ltd has introduced the technology from Siemens in Germany has greatly improved the quality of food grade flow meter to the world leading level. To be frank, the accuracy if our products is double higher than the similar products in Japan. In food grade flow meter, even the little screw holes or the gears and the watch cases are all accomplished by the Siemens’s technology of numerically controlled production center. Due to this, the production of food grade flow meter gets rid of the traditional manufacturing technique and will get landmark achievement. In the future the flow meter in our company will be produced to resist the high temp and pressure. Besides, we will try our best to keep pace with the world not only in the quality of our products but also in the level of resisting high temp and pressure. In our company, we have the stock of food grade flow meter of all caliber. From this, it is not hard to find that our company has sufficient funds and our products sale good. Nowadays, there hardly exist companies who own the ability to keep stock. But we dare and have the strength to do that.
Thermal gas mass flow meter is designed on the basis of thermal dispersion, and adopts method of constant differential temperature to measuring gas flow. It has advantages of small size, easy installation, high reliability and high accuracy, etc. The meter contains two platinum resistance temperature sensors. The thermal principle operates by monitoring the cooling effect of a gas stream as it passes over a heated sensor. Gas flowing through the sensing section passes over two sensors one of which is used conventionally as a temperature sensor, whilst the other is used as a heater. The temperature sensor monitors the actual process values whilst the heater is maintained at a constant differential temperature above this by varying the power consumed by the sensor. The greater the gas velocity, the greater the cooling effect and power required to maintain the differential temperature. The measured heater power is therefore a measure of the gas mass flow rate. The format of gas velocity and power is shown as below: â?¦â?¦(1) Where: is specific gravity of medium V is velocity K is balance coefficient Q is heater power Î? T is differential temperature The medium temperature range of meter is -40ï½?220. In the format (1), the specific gravity of medium is related to the density: â?¦â?¦(2) Where: is the medium density in working conditionkg/m3 Ï�n is the medium density in standard condition, 101.325kPa and 20 kg/m3 P is the pressure in working conditionkPa T is the temperature in working condition In the formats (1) and (2), there is a certain functional relationship between the velocity and pressure in working condition, medium density, the temperature in working condition. Due to the sensor temperature is always 30 higher than the medium temperature (environment temperature), and the meter adopts method of constant differential temperature, therefore the meter do not need to do temperature and pressure compensation in principle
Supplier: Electromagnetic flow meter, gas flow meter, level transmitter, controller, converters, temperature controller, timer, auto scanner, paperless recorder level & flow solution, online ph, conductivity, do system,, panel meter, all type of temperature sensors, proximity switches, pressure transmitter, pressure switch, control valves, butterfly valve, pressure regulating valve, pneumatic & pneumatic rupture disc, centrifugal blowers
Introduction CJW01 Turbine Flow Meter is a new generation of turbine flow meter, which absorbs the advanced technology of flow meters at home and at abroad, and has the characteristics of simple structure, light weight, high accuracy, good reproducibility, sensitive response, easy installation and maintenance. It is matched with the display instrument with special functions.It can also carry out quantitative control, excessive alarm and so on. It is an ideal instrument for flow measurement and energy saving. Features Simple Structure Light weight High accuracy Good reproducibility Sensitive response Easy installation and maintenance Technical Parameter Standard turbine flowmeter (JB/T9246-1999) Instrument caliber& connection methods: 4, 6, 10, 15, 20, 25, 32, 40 with threaded connections; 15, 20, 25, 32, 40) 50, 65, 80, 100, 125, 150, 200, flanged connections Precision grade: + 1%R, + 0.5%R, + 0.2%R (customize) Meassure Range: 1:10, 1:15, The instrument body material: 304 stainless steel or aluminum Impeller: anticorrosion ABS or high quality aluminum alloy Converter: cast aluminum Usage Condition: medium temperature: -20 C ~ +80 C environment temperature: -30 C ~ +60 C Relative humidity: 5% ~ 90% Atmospheric Pressure: 86KPa ~ 106Kpa Working Power Supply: A: power supply: +24VDC + 15%, rippleâ?¤5%, suitable for 4 ~ 20mA, pulse output, RS485 etc. B: 1 group 3.0V010AH lithium battery, the battery voltage can work normally from 2 to 3.0V Overall power consumption A: external power: < 1W B: Internal power supply: average power consumptionâ?¤1W, more than three years of continuous use Analog output: pulse signal, 4 ~ 20mA current signal, control signal Communication output: RS485 Real time record, Start and stop record, diary, fixed time interval record Internal thread: M20*1.5 of or user self determination Explosion-proof grade: ExdIIBT6 or ExiaIICT4 Protection grade: IP65 Product Application Widely used for measuring the closed pipes and stainless steel 1Crl8Ni9Ti, 2Cr13 and AI203, corundum hard alloy do not corrode, and no fiber, particles and other impurities. When working temperature, kinematic viscosity should be less than 5 * 10-6m2/s liquid. When kinematic viscosity greater than 5 x 10-6m2/s liquid, can label flow meter actually before use