Maximum Input Current The instantaneous maximum output of SERVOPACK is approximately 3 times of the rated output for maximum for 3 seconds. Accordingly, select a molded-case circuit breaker whose breaking time is 5 seconds or more at 300% of SERVOPACK rated current. The general-purpose low-speed acting molded-case circuit breakers are applicable. The power supply capacity per SERVOPACK when using a servomotor is described in 2.5.2 Molded-case Circuit Breaker and Fuse Capacity. Select a molded-case circuit breaker with the capacity larger than the effective load current (when using more than multiple SERVOPACK) calculated from the total power supply capacity. The consumption of other controllers must be considered when selecting a molded-case circuit breaker (2) Inrush Current Refer to 2.5.2 Molded-case Circuit Breaker and Fuse Capacity for SERVOPACK inrush current. The allowable inrush current for a low-speed acting molded-case circuit breaker is approximately 10 times of the rated current for 0.02 seconds. When turning ON multiple SERVOPACK simultaneously, select a molded-case circuit breaker with the allowable current for 20 ms larger than the total inrush current shown in 2.5.2 Molded-case Circuit Breaker and Fuse Capacity.
Circuit breaker refers to the switching device that can close, carry and disconnect the current under normal circuit conditions, and can close, carry and disconnect the current under abnormal circuit conditions within a specified time. Circuit breakers are divided into high-voltage circuit breakers and low-voltage circuit breakers according to their scope of use. The division of high-voltage and low-voltage boundaries is relatively vague. Generally, those above 3KV are called high-voltage appliances. The circuit breaker can be used to distribute electric energy, start the asynchronous motor infrequently, and protect the power line and motor. When they have serious overload, short circuit, undervoltage and other faults, it can automatically cut off the circuit. Its function is equivalent to the combination of fuse switch and over and under heating relay. Moreover, it is generally not necessary to change the parts after breaking the fault current. At present, it has been widely used. Power distribution is an extremely important link in the generation, transmission and use of electricity. The distribution system includes transformers and various high and low voltage electrical equipment, and the low voltage circuit breaker is an electrical appliance with large amount and wide range of use. working principle The circuit breaker is generally composed of contact system, arc extinguishing system, operating mechanism, release, shell, etc. In case of short circuit, the magnetic field generated by large current (generally 10 to 12 times) overcomes the reaction spring, the release pulls the operating mechanism to act, and the switch trips instantaneously. In case of overload, the current increases, the calorific value intensifies, and the bimetallic sheet deforms to a certain extent to promote the action of the mechanism (the greater the current, the shorter the action time).
ZW32-24 type outdoor pole-mounted HV vacuum CB (hereinafter referred to as CB) is rated voltage24kV, 50Hz three-phase AC outdoor power distribution equipment used for power distribution network to break and close load current, over-load current and short-circuit current in electric systems. It is used in substation and industrial & mining enterprise power distribution system for protection and control, better fits countryside power grid and frequent operation places, especially for the retrofit of urban power network and countryside power network. Characteristic: The CB applies three-phase pole-type structure. It has characteristics of stable closing/breaking property, no fire or explosion danger, maintenance-free, small dimension, small weight, long service life, etc. The CB is hermetical sealed, and is moisture-resistant, anti-condensation. It is especially suitable for application at severe cold and damp areas. Three-phase pillar and current transformer apply imported outdoor epoxy resin solid insulation materials. It is high/low temperature resistant, UV-resistant and anti-ageing. The operating mechanism is miniature spring operating mechanism with low breaking/closing energy consumption. The driving of it applies straight transmission with little components and high reliability. The operating mechanism is enclosed in a cabinet, and that makes it rust-resistant and more reliable.
CW1 series intelligent universal circuit breaker (hereinafter referred to as circuit breaker), Apply to 50Hz AC, Rated voltage to 660V (690V) and below, in the distribution network with rated current of 200A ~6300A, circuit break used to distribute electric energy and protect circuit and power equipment from overload, undervoltage, shortcircuit, single-phase grounding and other faults has intelligent protection function. Selective protection is accurate, it can improve the reliability of power supply, avoid unnecessary power failure, and has an open communication interface. It can carryout "four remote" to meet the requirements of the control center and the automation system. The circuit breaker has a pulse withstand voltage of 8000V at an altitude of 2000 meters (the maximum withstand voltage is not more than 12000V according to the standard for different altitudes). The circuit breaker can be used as an isolator without intelligent controller and sensor, and is marked as -*The circuit breaker conforms to GB14048.2 "Low Voltage Switchgear and Control Equipment Low Voltage Circuit Breaker" and EC60947-2 "Low Voltage Switchgear and Control Equipment Circuit Breaker" and other standards. Normal Working and Installation Conditions Ambient air temperature The upper limit value shall not exceed +40 �ºC, the lower limit value shall not be lower than-5 �ºC, and the 24-hour average value shall not exceed +30 C; Note: For working conditions with the lower limit value of-10 C or-25 C, the user should declare it with the company. For working conditions where the upper limit value exceeds + 40T: or the lower limit value is lower than-10 C or-25 C, the user shall negotiate with the company; The altitude of the installation site shall not exceed 2000m. Atmospheric conditions The atmospheric relative humidity shall not exceed 50% when the ambient air is + 40 C, and may have higher relative humidity at lower temperatures. The monthly average maximum relative humidity in the wettest month is 90%, and the average minimum temperature in that month is + 25 C. Considering that the condensation on the product surface due to temperature change exceeds the specified requirements, the company shall be consulted. Protection level: IP30 Pollution level: III Use category: category B or category A Installation category Circuit breakers with rated working voltage of 660V (690V) and below, undervoltage releases and primary coils of power transformers are used for installation of Class IV; The installation category of auxiliary circuits and control circuits is III; The circuit breaker shall be installed according to the requirements of this specification. The vertical inclination of the circuit breaker shall not exceed 5 degrees (the inclination of the mine circuit breaker shall not exceed 15 degrees).
1.With the voltage of 40.5kV is three-phase AC, 50/60 Hz indoor power distribution equipment. 2.It is used for switchgear KYN61-40.5(Z) 3.It is accordance with GB1984 AC HV vacuum circuit breaker standard. 4.It effectively reduces the dimensions of VCB, the overall arrangement is reasonable and simple,with aesthetic appearance. 5.It has high reliable with characteristics of long life and easy maintenance and free-maintenance for operating mechanism. 6.Meet the Five Preventions function.
1.Use spring energy storage. 2.Operating by two ways: manual or electric operation 3.The characteristics is accordance with GB1984-2003 AC High Voltage Circuit Breakers, JB3855-96 3.6~40.5kV indoor AC HV vacuum circuit breaker, relevant regulations of IEC62271-100 standard and the technical requirements of this product. 4.Use modular type operating mechanism and embedded pole The mechanical life is M2 and electrical life is E2
CW1 series intelligent universal circuit breaker (hereinafter referred to as circuit breaker), Apply to 50Hz AC, Rated voltage to 660V (690V) and below, in the distribution network with rated current of 200A ~6300A, circuit break used to distribute electric energy and protect circuit and power equipment from overload, undervoltage, shortcircuit, single-phase grounding and other faults has intelligent protection function. Selective protection is accurate, it can improve the reliability of power supply, avoid unnecessary power failure, and has an open communication interface. It can carryout "four remote" to meet the requirements of the control center and the automation system. The circuit breaker has a pulse withstand voltage of 8000V at an altitude of 2000 meters (the maximum withstand voltage is not more than 12000V according to the standard for different altitudes). The circuit breaker can be used as an isolator without intelligent controller and sensor, and is marked as -*The circuit breaker conforms to GB14048.2 "Low Voltage Switchgear and Control Equipment Low Voltage Circuit Breaker" and EC60947-2 "Low Voltage Switchgear and Control Equipment Circuit Breaker" and other standards. Normal Working and Installation Conditions Ambient air temperature The upper limit value shall not exceed +40 �ºC, the lower limit value shall not be lower than-5 �ºC, and the 24-hour average value shall not exceed +30 C; Note: For working conditions with the lower limit value of-10 C or-25 C, the user should declare it with the company. For working conditions where the upper limit value exceeds + 40T: or the lower limit value is lower than-10 C or-25 C, the user shall negotiate with the company; The altitude of the installation site shall not exceed 2000m. Atmospheric conditions The atmospheric relative humidity shall not exceed 50% when the ambient air is + 40 C, and may have higher relative humidity at lower temperatures. The monthly average maximum relative humidity in the wettest month is 90%, and the average minimum temperature in that month is + 25 �ºC. Considering that the condensation on the product surface due to temperature change exceeds the specified requirements, the company shall be consulted. Protection level: IP30 Pollution level: III Use category: category B or category A Installation category Circuit breakers with rated working voltage of 660V (690V) and below, undervoltage releases and primary coils of power transformers are used for installation of Class IV; The installation category of auxiliary circuits and control circuits is III; The circuit breaker shall be installed according to the requirements of this specification. The vertical inclination of the circuit breaker shall not exceed 5 degrees (the inclination of the mine circuit breaker shall not exceed 15 degrees).
VS1-12 type indoor high voltage vacuum circuit breaker is the indoor switch device for three-phase AC 50Hz, rated voltage 12kA power system, can be used for electrical equipment control and protection in power plant, substation and industrial and mining enterprises, and is suitable for frequent operation place, can be installed in the KYN28-12 type and other armored cabinet, can also be installed on the fixed cabinet or gas insulated cabinet. Design feature VS1-12kV indoor medium voltage sealed vacuum circuit breaker (12kV, .4000A, .50kA) VS1 indoor medium voltage sealed vacuum circuit breaker with maintenance free sealed vacuum pole, can equipped with modular spring assembling actuator and permanent magnetic actuator; has the features of reliable performance, long mechanical life, maintenance free, small mechanical movement, has the advantages of simple structure, good process performance, but also can be applied to all kinds of bad working environment. VS1 circuit breaker pole adapts the solid insulation sealing technology, seal the vacuum interrupter and primary main galvanic circle and other parts into strong insulation, high mechanical strength pole with epoxy resin, avoid the influence of adverse operating environment on the primary circuit external insulation, realizes completely maintenance free. VS1 circuit breaker adapt ultra low resistance type vacuum interrupter, meet the VCP circuit breaker requirements on the temperature rise at big current operation situation and reduces the power losses. VS1 circuit breaker adapt optimization and modular spring operating mechanism, simple structure, stable performance, convenient maintenance; modular production process is good, easy standardization production, short delivery cycle.
ZW32-24 type outdoor pole-mounted HV vacuum CB (hereinafter referred to as CB) is rated voltage24kV, 50Hz three-phase AC outdoor power distribution equipment used for power distribution network to break and close load current, over-load current and short-circuit current in electric systems. It is used in substation and industrial & mining enterprise power distribution system for protection and control, better fits countryside power grid and frequent operation places, especially for the retrofit of urban power network and countryside power network. Characteristic: The CB applies three-phase pole-type structure. It has characteristics of stable closing/breaking property, no fire or explosion danger, maintenance-free, small dimension, small weight, long service life, etc. The CB is hermetical sealed, and is moisture-resistant, anti-condensation. It is especially suitable for application at severe cold and damp areas. Three-phase pillar and current transformer apply imported outdoor epoxy resin solid insulation materials. It is high/low temperature resistant, UV-resistant and anti-ageing. The operating mechanism is miniature spring operating mechanism with low breaking/closing energy consumption. The driving of it applies straight transmission with little components and high reliability. The operating mechanism is enclosed in a cabinet, and that makes it rust-resistant and more reliable.
moulded case circuit breaker with rated insulation voltage 800V, applied in the power system of AC50(60)Hz, rated voltage 690V and below, rated current 1250A and below as the transfer not frequently. The circuit breaker has the protection devices of over load, short circuit and under voltage ,it can protect the circuit and power equipment from broken. The mccb can be sorted to C type (basic),L type (standard),M type (high breaking), H type(higher breaking) according to its rated limit short circuit breaking capacity. The mccb has the features small volume, breaking capacity high, electric arcing short ,anti-vibration. It is the ideal product for application in land and ship. The installation can be vertical or level and the standard conforms to IEC60947-2 and GB14048.2
Circuit breaker
Specifications Condition New Power Source Electric Features Durable, Easy To Fir, High Performance, Stable Performance, Water Proof Warranty 3years Applications Industrial Puncture Voltage 100-200V, 300-400V, 500-600V, 700-800V MOCB, ACB, SF6 CB, Vacuum CB, High Voltage Circuit Breakers
1. Bit Breakers The Bit Breakers are suitable to make up or break out the drilling bit during the oil well drilling and repairing operations. The Users should be chosen the bit breaker according to the size and model of the drilling bit. Feature:Improve support and retention Advantage:Manage the magnitude cutter loading and bit torque Benefit:Improved bit durability and directional responsiveness Advantage:Higher nozzle counts and/or fixed ports to best serve cleaning,cooling and cuttings evacuation requirements with available hydraulic flows.Allow for higher flow rates with minimal increase in pump pressure. 2. Detailed introduction to Bit breaker 1) Bit breaker is mainly used to screw on or off a rock bit to the bottom of drill string. 2) It can also prevent the rock bit from dropping into well hole. 3) The price of it is cheap and the use of it is safety and reliable. 4) It is easy to operate. First, the bit breaker is placed on well hole and then put the rock bit onto it. Turn it to screw on or off the bit by turnplate.
Cw magnetron glcwm-100l(t) Glcwm-100l is fixed-frequency cw magnetron, mainly used in microwave heating and plasma generators. Glcwm-100l has the following features: Metal ceramic structure, good strength, suitable for industrial application Special cathode, insurance of long life Special device for the internal cathode terminal, minimize the microwave leakage. Operating frequency : 915mhz minimum output : 100kw
SH200 Miniature Circuit Breaker Resin Type, ,Sh200 Mcb
Juki 2060 ejector 40001266 c-0023-mcx mps-v8 v8x-ag-0.3b-ju Juki ke700 ke2000 fx-1 fx-1r Juki ke2010/2020/2030 cpu board acp-122j pn: e9656729000 e96567290a0 Juki ke2050/2060 cpu board acp-128j acp-125j n:40044475 40003280 Juki ke2010/2020/2030 laser card ke2050/2060/fx-1r mcm 4shaft pn: e9609729000 e9610729000 Juki ke2060 right head laser card 9610729000 mcm 1 shaft Juki ke2050/2060 xmp board xmp-synqnet-cpci-dual p/n:40003259 Juki ke2050/2060 zt rmb-sti-synqnet-4 p/n:40003320 Juki 2060 ejector 40001266 c-0023-mcx mps-v8 v8x-ag-0.3b-ju Juki fx-1/r base-feeder pcb p/n:40007370 Juki ke2010 base-feeder e86027290a0 Juki ke2010 safty board e86017290a0
High efficiency high flux density carbon infrared heating lampscarbon medium wave infrared lamps features: wavelength range of carbon red heating ir heater: 2.5-2.7 um. cross sectionof carbon red heating ir heater: 33*15mm twin tube diameter.Applied industry: printing painting drying, powder coating drying, paint drying, plastic heating and drying, thin film strecthing, etc.Carbon red heating ir heater model cfir332620wlamp model: cfir332620wquartz tube: white coatinglamp length: 2620mmactive length:2500mmvolatge:400vpower: 6250wcable length: 500mm one side outcolor temperature: 1800-2400kwavelength of ir radiation: 2.5-2.7umcarbon red heating ir heatermax heated length 3200mmmax total length 3400mm;max power output: 9000-12000w;max voltage: 600v;average lifetime of carbon red heating ir heater: 10, 000 hourspart no. voltagewattagetwin tubetotal
transparent high purity quartz heater tube transparent high purity quartz heater tube is one of infrared heating element, which is the most efficient and mostenergy-saving type in the heating area. It can not only improve your heating speed by higher power, but also it will help you save more enrgy by using the shortwave infrared heater to replace the other heaters. transparent high purity quartz heater tubelamp model: swir-10500tube coating: golden reflectorlamp length: 500mmactive length: 440mmvolatge: 220vpower: 800wcable length: 600mmcolor temperature: 2000-2700kwavelength of infrared radiation: 0.75-1.4um ir benefits and features long lifemore than 5000h high speedwithin 1 second to switch onhigh efficiencymore than 85% heat efficiency of full powerhigh power densityup to 200w/cmhigh control abilityneither ballast nor special circuits are necessary for basic usageno air droughtsbecause of radiation(like solar energy)clean and odorlessno risk of contamination over environment or target object to be heatedextensive assortmentmany types of voltage, wattage, length, base, cables, horizontal
Ishcanto ixd47-63 series miniature circuit breaker is made of plastic shell, operating mechanism, contact arc system, tripping mechanisum and other components. The shell is made of high-strength special plastic, with strong impact capability and light wieght. Feature: short circuit protection Isolation function Overload protection Control
Product Description : Modular Circuit Breakers - xC60. Breaking Capacity as per IEC 60947-2, Icn = 15kA, upto 40A, Higher Installation Life : Energy limitation class: 3, Tropicalization: T2 - relative humidity 95% at 55C. Higher performance by Low cost : Cascading. Increase system continuty : Discrimination. Reference Temperature of 50C as per IEC60947-2. Product Specification: Brand - Schneider Model Name - A9N2P01C Current Rating - 1A Pole - Two Pole Rated operational voltage - 100V - 125V DC, 240V AC 50/60 Hz, 380V - 415V AC 50/60 Hz Rated service breaking capacity - 6kA conforming to EN/IEC 60947-2, 100V - 125V DC, 7.5kA conforming to EN/IEC 60947-2. 380V - 415V AC 50/60Hz Curve code - C Nominal Frequency - 50Hz / 60Hz Mounting Type - Clip-on Weight (in kg) - 0.250 Warranty - 2yr (on manufacturing defect)